OPERATING INSTRUCTIONS MAXIMAT LW CX COMPACT LEAKAGE SENSOR

Similar documents
Leakage detection sensor

Alarm system For oil-water separator

OPTISENS TUR 2000 Technical Datasheet

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

THERMASREG TR 040 THERMASREG TR 060

Vibracon LVL-A* Level limit switch for liquids, compact design

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Alarm Switchgear AS1-M

1.7. Insulation fault evaluators EDS460/490 EDS461/491

QFM21... Duct sensors. Symaro. for relative humidity and temperature

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

OilMatic Pro / 230 V AC

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

SITESTAR CABINET DESCRIPTION

AND INSTALLATION MANUAL

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET-1000 (12 VDC)

Operating instructions DVC-P / Bedienungsanleitung Druckregler DVC-P

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

SET-2000 Hi Level/Oil

Liquiphant T FTL20H. Technical Information

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

Snifter ATEX22 VERSION. User Manual. Distributor

Inductive slot sensor

Insulation fault evaluator EDS460-DG

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

GAN Electronic 750W/1000W DE EU

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Instructions for the fan motor control system, SILVER C

Ultrasonic Level Measurement nivopuls FDU 10 S

PROTECT SRB 200EXi-1A

Technical Data. Dimensions

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Installationsmanual GWSL1100/2100, GWML3100

User manual DEAN-10-C

Operating Manual MS220DA

IT system floor-standing distribution

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

RE-PR3-E-27 3-Phase Panel Mount 27kW

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

SET-2000 Oil/Sludge 12 VDC

Leakage Sensor LS-50 SGB

Operating Instructions. For. Alarm Control Module. Model SSR 500

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER

Technical Data. Dimensions

SINGLE MONITORED INPUT UNIT BN-303

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Process Automation. Sensors and Systems: Level Sensors Level Detectors Overfill Prevention. Process Automation. Accuracy.

Conductive Leakage detectors of the Leckstar range

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Instructions for the fan motor control system with integrated wiring terminals SILVER C

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

SET Installation and Operating Instructions. Level switch for one sensor

HYTEK ATEX APPROVED TANK ALARM

1.7. Insulation fault evaluators EDS460/490 EDS461/491

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Earth-Rite II PLUS Static Earthing System

WIO200 Water In Oil measuring instrument

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

PolyGard 2-channel Gas Controller MGC-03

Condensate drains WA/PWEA

Leakage Detection. WaterAlarmSystems Fuel-oil/WaterAlarms. Safe protection for plants and buildings...leakage Detection Systems provided by BARTEC

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

EUROFLAT SERIES TYPES C... S... M...

EUROBOX SERIES TYPES CM... SM... MM...

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Instructions for the BASIC BCRW Fan, Sizes General

ED3002 ED3004 ED3007 ED3030 ED3100

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Hygro/hygrothermal transducers (hygrometric)

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

Technical Data. Dimensions

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

SECTION Fluorescent Dissolved Oxygen Measuring System

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

Hygro/hygrothermal transducers (hygrometric)

Instruction Manual April sitrans AS 100

Technical Data. Dimensions

Installation, operation & service manual. AlarmScout 961/962 line powered

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Transcription:

Safety Precautions Installation, initial start-up and maintenance may only be performed by trained personnel! The device may only be connected to power which complies with the specifications included in the technical data and on the serial plate! The device must be disconnected from all sources of power during installation and maintenance work! The device may only be operated under the conditions specified in these operating instructions! Functions Description The MAXIMAT LW CX compact leakage sensor is used as a leakage monitoring device for permanently installed containers used for the storage of non-flammable, water endangering liquids. Applications The leakage sensor is only suitable for conductive liquids with a specific reactive impedance of less than 5kΩ, or a mutual capacitance to earth of greater than 50pF. Stored liquids may not tend to precipitate insulating or conductive sediments. Technical Data Functional principal: Ambient temperature: Operating pressure: Capacitive high-frequency, fail-safe -20 to +60 C Atmospheric, 0.8 to 1.1bar Terminal housing: PBT, fibre-glass reinforced, IP65 protection per EN 60 529 Process interface: Supply power: Connected load: <1W Cable: See order information 15 to 27V DC PVC, 5 x 0.34mm² SU3560c.doc 07/13 1

Technical Data (continued) Materials: Angle bracket / tube cap: PVC Sensor unit: PVC / PE Outputs: Floating reed relay contact (contact opens in case of alarm) for extra-low voltage, max. 50V AC / DC, max. 0.5A, max. 10VA e.g. for connection to coupling relays or PLC, TC4 signalling device or CST supply power isolator Observe protective measures for reed relay contacts (see instruction leaflet SU3101) 2-wire alarm evaluation with MAXIMAT SHR C measuring transducer Note: Simultaneous use of both outputs is not possible. Input: For external test button (connection to terminals T and C) Test button contact closed = test alarm is triggered Note: The function test executed with the test button does not replace the operating test specified in ZG-ÜS, section 6.2, which must be conducted for all s on a regular basis at least once a year. Connector cable: (for variant without terminal housing only): shielded PVC cable, 5 x 0.34mm² Indication: LED (green) on the connector PCB (for variant with terminal housing only): Run: LED illuminated Alarm/error: LED off Measuring circuit cable length: Max. 300m, min. wire cross-section: 0.5mm² CE Mark In accordance with low-voltage directive RL 2006/95/EC and EMC directive 2004/108/EC DIBT Approval Approval no. Z-65.40-496 for overfill inhibitors and leakage sensors in accordance with WHG 19 The accompanying General Building Supervisory Approval no. Z-65.40-496 is an integral part of the operating instructions and all stipulations contained therein must be adhered to! Dimensions SU3560c.doc 07/13 2

Installation: The leakage sensor s is suspended such that it hangs into the catch basin of the storage tank to be monitored. The may make contact with the outside wall of the catch basin, or may stand on its floor. The cable must be secured such that the is always positioned vertically. When installed in a free-hanging fashion, it must be assured that the connector cable is only pulled far enough through the adjuster fitting to allow for a maximum clearance of 40mm between the and the catch basin floor, so that the leakage alarm is triggered at a maximum fill-level of 50mm. If the MAXIMAT LW CX... 0 variant without terminal housing is used, other suitable mounting components must be utilised in an appropriate fashion. The leakage sensor must be secured against shifting, swaying and floating up. The mounting components must be resistant to the media. Attention! In the event of a leak, the sensor must be removed from the medium immediately. It must be effectively cleaned (rinsed), and may not be reinstalled to the dry catch basin until after it has been subjected to a complete function test. Continuous immersion is impermissible, because the cable may otherwise be destroyed and moisture may penetrate the sensor. Note: Check the lid seal for damage and correct seating! Materials In the event of a tank leak, the leakage sensor comes into contact with the stored liquid, or vapours and condensate resulting therefrom. For this reason, leakage sensor materials must be selected which are adequately resistant to the liquid to be monitored. Component Material Sensor and sensor tube PVC, PE Terminal housing / housing PBT Mounting components PVC (polyvinyl chloride) or PE (polyethylene) Cable gland PA (polyamide) Cable gland seal Perbunan / EPDM Connector cable PVC Settings fixing bracket cap with adjustable cable gland catch basin max. ground clearance 40mm Installation Example: Storage Tank Leakage Sensor The leakage s are installed inside catch basins. If the bottom of the contacts the floor of the catch basin, the alarm signal is triggered when the liquid reaches a fill-level of approximately 6mm. For applications involving storage tank catch basins, the must be installed such that the alarm signal is generated at a filllevel of 50mm or less. SU3560c.doc 07/13 3

Electrical Connection Variant With Terminal Housing Variant With Cable Connection L+ 0 V power supply 15...27V DC control voltage L+ 0 V power supply 15...27V DC control voltage digital input PLC digitalinput PLC green grey ALARM = 0 ALARM = 0 Coupling Relays or PLC Coupling Relays or PLC green (T) (S) grey(s) Sonde MAXIMAT TC4 Signalling Device MAXIMAT TC4 Signalling Device (1) The cable shielding only needs to be connected to operational earth with minimal interference voltage if increased EMC interference can be expected. SU3560c.doc 07/13 4

Electrical Connected (continued) Variant With Terminal Housing Variant With Cable Connection (S) grey(s) green(t) CST Supply Power Isolator CST Supply Power Isolator measuring transducer MAXIMAT SHR CS measuring transducer MAXIMAT SHR CS green (T) grey (S) NC (S) MAXIMAT SHR CS External Measuring Transducer MAXIMAT SHR CS External Measuring Transducer (1) The cable shielding only needs to be connected to operational earth with minimal interference voltage if increased EMC interference can be expected. SU3560c.doc 07/13 5