INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Electric Heat Accessory

INSTALLATION INSTRUCTIONS

ECTRIC INSTRUCTIONS FURNACE. Models / / EF08B1500A1, EF12F1900A EF16J2200A EF20N2600A. With AMF001NHA Accessory No Heat Kit

INSTALLATION INSTRUCTIONS TXV Coils EBU, EBA

INSTALLATION INSTRUCTIONS TXV Coils EBD, EBA

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA

EL SERIES INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

INSTALLATION INSTRUCTIONS Apartment Fan Coil

TECHNICAL SUPPORT MANUAL Fan Coils FVM4X B Series

INSTALLATION INSTRUCTIONS APARTMENT FAN COIL UNIT FMA4X, FMA4P

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Installation Instructions

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

Installation Instructions

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

Installation Instructions

Installation Instructions

Your safety and the safety of others are very important.

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHX SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION MANUAL SINGLE PIECE STANDARD ECM AIR HANDLERS MODELS: AHX61 SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHP SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

AHG**-0B Series Hydronic Air Handling Units

MERIT SERIES Up Flow / Horizontal

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY UIM-C-0214

INSTALLATION MANUAL SINGLE PIECE, 4 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

INSTALLATION INSTRUCTION

MERIT Series R-410A - Upflow / Horizontal

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

MERIT Series R-410A - Upflow / Horizontal

INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

Installation Instructions

Installation Instructions

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Installation Instructions

FOSSILFUELKITAXWR02FFA1

ACCESSORY KIT INSTALLATION MANUAL ADD-ON FOSSIL FUEL CONTROL PANEL S1-2AC FOR USE WITH MODELS: FRHS, E*FD, E*RE OR E*BE HEAT PUMPS

Installation Instructions

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP

Installation Instructions

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

Electric Heat Accessory Installation Instructions

Installation Instructions

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP MODELS: TABLE OF CONTENTS LIST OF FIGURES

B SERIES ELECTRIC FURNACE

INSTALLATION INSTRUCTIONS

R-410A. Installer s Guide WARNING: 18-GE04D2-5

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 10, 16, 26, 36 & 72

CBX32MV (HFC-410A) SERIES UNITS

Installation Instructions

Installation Instructions

Installer s Guide Convertible Air Handlers 1-1/2 5 Ton

Installation Instructions

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP

Installation Instructions

Installation Instructions

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

Installation Instructions

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

Transcription:

INSTALLATIN INSTUCTINS Models FC2400C2 FC3600C2 FC4800C2 FC6000C2 equires AMF001NHA Accessory No Heat Kit Contents Use NL factory listed electric heaters. General Information / Installation... 2 Upflow Installations... 3 Horizontal Installations... 3 Ductwork Connections... 3 Filter Installation... 4 Condensate Drain... 5 efrigerant Lines... 5 Electrical Connections... 6 Motor Speeds and Airflow... 7 Blower Performance... 9 Checks and Maintenance... 10 Wiring Diagram... 11 eplacement Parts... 12 ariable Speed Fan Coils Safety Labeling and Signal Words Danger, Warning and Caution The signal words DANGE, WANING and CAUTIN are used to identify levels of hazard seriousness. The signal word DANGE is only used on product labels to signify an immediate hazard. The signal words WAN- ING and CAUTIN will be used on product labels and throughout this manual and other manuals that may apply to the product. DANGE -- Immediate hazards which WILLresult in severe personal injury or death. WANING -- Hazards or unsafe practices which CULD result in severe personal injury or death. CAUTIN -- Hazards or unsafe practices which CULD result in minor personal injury or product or property damage. Signal Words in Manuals The signal word WANING is used throughout this manual in the following manner: WANING The signal word CAUTIN is used throughout this manual in the following manner: CAUTIN Product Labeling Signal words are used in combination with colors and/or pictures on product labels. PrintedinU.S.A. 496 01 4109 02 June 2002

Installation Instructions Fan Coils Figure 1 Dimensions and Clearances 3/4 A 14-3 / 8 (2 Ton) 17-7 / 8 (3 Ton) 25-1 / 8 (4 / 5 Ton) 1 CLEAANCES 8 1 / 2 12 42 (2&3 Ton) 52 (4-5 Ton) N HEATES All Sides... 0 From Supply Duct... 0 ecommended Service From Front... 20 (Service for blower, filter if installed) WITH HEATES All Sides... 0 From First Three Feet of Supply Duct to Combustibles... 1 From Duct after Three Feet... 0 ecommended Service From Front... 20 (Service for blower, filter, heaters if installed) Filter Door W 16-3 / 8 (2 Ton) 19-7 / 8 (3 Ton) 27-1 / 8 (4/5Ton) 21 1 / 2 Bottom eturn Air pening 14 1/2 X 20 2 Ton 18 X 20 3 Ton 25 1 / 4 X20 4-5Ton Fire Hazard When heaters are installed maintain clearances from combustible materials as specified on unit rating plate. Do not use plastic lined or combustible flexible ducting within 36 inches of the supply end of the air handler. Failure to do so can result in fire, property damage, personal injury and/or death. General Information Installation or repairs made by unqualified persons can result in hazards to you and others. Installation MUST conform with local building codes and with the National Electrical Code NFPA70 current edition. The information contained in this manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments. Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death. The blower cabinet may be used for cooling or heat pump operation with or without electric heat. Installations without electric heat, require a No Heat Kit.The cabinet can be installed in an upflow or horizontal position (Figure 2, 3). Horizontal installations require a horizontal kit. Some models are shipped with the horizontal kit already installed.these units are not shipped with air filters installed. Filter must be field supplied, either washable or disposal type. Washable filters are available as an accessory. Location Select the best position which suits the installation siteconditions. The location should provide adequate structuralsupport, spacein the front of the unit for service access, clearance for return air and supply duct connections, space for refrigerant piping connections and condensate drain line connections. If heaters are being installed make sure adequate clearance is maintained from supply ductwork, See Clearances and Warning in Figure 1. NTE: Internal filter can be accessed from separate filter door. If the filter can NT be easily accessed, a remote filter is recommended. efer to ACCA Manual D for remote filter sizing. If the unit is located in an area of high humidity, nuisance sweating of casing may occur. n these installations a wrap of 2 fiberglass insulation with a vapor barrier should be used. 2 496 01 4109 02

Fan Coils Upflow Installations The unit is ready to install in the upflow position without modifications. The unit MUST be supported on the bottom NL and set on a supporting frame or shelf. Use screws through the bottom to anchor to supporting frame. Figure 3 Airflow Positions Installation Instructions Figure 2 Airflow Positions Non-Ducted eturn Air Closet Installation The cabinet can be installed in a closet with a false bottom to form a return air plenum, or mounted on an open platform inside the closet. Platform should be high enough to provide a free (open) area for adequate return airflow into the bottom of the cabinet. The open area can be on the front side or a combination of front and sides, providing there is clearance on the sides betweencabinet and closet. efer to ACCA Manual D for sizing and free area recommendations. NTE: Local codes may limit application of systems without a ducted return to single story dwellings. Horizontal Left and ight Installations Units that are shipped with the horizontal drain pan installed are set up for horizontal left hand airflow. They must have the drain pan repositioned for right hand airflow. All other units must have the horizontal drain pan kit installed for either left or right hand applications. For installation of the drain pan, refer to the installation instructions included with the horizontal drain pan kit, and the following. CAUTIN A field-fabricated auxiliary drain pan, with a seperate drain is EQUIED for all installations over a finished living space or in any area that may be damaged by overflow from the main drain pan. In some localities, local codes require an auxiliary drain pan for AN horizontal installation. Drain Pan Installation / Conversion for ight Hand Airflow SeeFigure4 1. emove coil access panel and carefully pull Coil/Horizontal Drain Pan Assembly out. 2. Separate horizontal drain pan from coil drain pan. The coil drain pan fits snuggly inside the horizontal pan. 496 01 4109 02 3. Position side of coil drain pan into horizontal drain pan trough on deep end of pan on right side of coil. 4 emove coil drip flanges from A--coil and reinstall on right side of coil (same side as horizontal drain pan). 5. emove the coil support bracket from the left side of the cabinet and reinstall bracket on the right side of the cabinet. 6. Install drain plugs as required in back side of horizontal drain pan. Install plugs in A coil drain pan to prevent air leaks. 7. Slide coil assembly into cabinet being careful not to tear insulation. NTE: Be sure A coil pan fits into the support bracket on the back side of the cabinet and that pan is under the flange of the bracket on the right side. The brackets fit over the top edge of the A coil drain pan to hold it when it s put into the horizontal position. 8. efer to estrictor rifice Selection and change restrictor if necessary, then install coil access panel. Cabinet can now be placed on it s side for horizontal airflow. Suspended Cabinet Installation 1. The cabinet may be supported on a frame or shelf, or it may be suspended. 2. Use metal strapping or threaded rod with angle iron supports under the auxiliary drain pan to suspend cabinet. These supports MUST run parallel with the length of the cabinet (Figure 5 ). 3. Ensure that there is adequate room to remove service and access panels after installing supporting brackets. 4. Place Styrofoam blocks in auxiliary drain pan to support cabinet. Duct Connections Supply Duct Supply duct must be attached to the outside of flange on outlet end of unit. Flexible connectors may be used if desired. Maintain clearances from supply duct to combustibles when heaters are installed. See Figure 1 and unit rating plate. eturn Duct eturn duct should be attached to bottom of unit using sheet metal screws or other fasteners. 3

Installation Instructions Fan Coils Figure 4 Horizontal Drain Pan Drip Flange mounts to top two holes in coil plate Horizontal Drain Pan (Left Hand Airflow) Coil Support Bracket (ight Hand Airflow) Coil Support Bracket Filter Door Coil Access Panel Drip Flanges (Left Hand Airflow) Plug drains on back side Coil Support Bracket (Left Hand Airflow) Drip Flanges (ight Hand Airflow) Horizontal Drain Pan (ight Hand Airflow) Filter Installation Filters must be field supplied. The blower cabinet is set up for an internal filter or a remote filter grille or other means may be provided. efer to ACCA Manual D for remote filter sizing. To install an internal filter, remove screw securing filter door and slide filter into unit. Some filters are marked for airflow direction, make sure arrow points towards blower if marked. Washable filters are offered as an accessory. Disposable filter sizes are listed in Filter Static Pressure Drop Table. Figure 5 Horizontal Installation Drain Lines efrigerant Lines Field-Fabricated Drain Pan Supports MUST run parallel with blower cabinet 4 496 01 4109 02

Fan Coils Condensate Drain Connections The unit is provided with 3/4 National Pipe Thread (NPT) condensate drains. (Figure 1). Any drain can be used as a primary or secondary drain depending on the fitting used. Condensate drain lines should be installed in a manner that does not obstruct access to the filter. There is a secondary drain fitting supplied with the unit that will convert any of the primary condensate drain connections into a secondary drain connection. This fitting should be installed in any of the primary drain connections to convert it to a secondary drain. Installation Instructions 3. oute to the outside or to a floor drain, laundry tray or waste line (sewer). Check local codes before connecting to a sewer line. 4. Insulate drain lines where sweating could cause water damage. 5. If a gravity drain cannot be used, install a condensate pump. Install the pump as close to the indoor section as possible. Figure 6 Condensate Drain Fittings Waste Line Connection If the condensate line is to be connected to a waste line, an open trap must be installed ahead of the waste line to prevent escape of sewer gases. NEE CNNECT THE DAIN LINE DIECTL T A WASTE LINE. ALWAS INCLUDE AN AI GAP AND TAP, (Figure 7). Be sure to keep the trap filled with water during the winter or off season. Figure 7 Condensate Drain to Waste Line Secondary Drain Fitting (small hole) Primary Drain Fitting Condensate Line Air Gap Above Liquid Level 1. Connect the drain lines to the appropriate drain fittings. 3/4 PC or other type of drain line may be used. The drain line must not be smaller than the drain fitting. 2. Install a trap in the drain line below the bottom of the drain pan and pitch the drain lines down from the coil at least l/4 per foot of run. Horizontal runs over 15 feet long must also have an anti--siphon air vent (stand pipe), installed ahead of the horizontal run. An extremely long horizontal run may require an oversized drain line to eliminate air trapping. Trap Sewer Line efrigerant Line Connections Size refrigerant lines according to information provided with outdoor condensing unit. oute the refrigerant lines to the coil in a manner that will not obstruct service access to the unit or removal of the filter. 1. emove rubber plugs from refrigerant connections using a pulling and twisting motion. Hold refrigerant lines to avoid bending or distorting. 2. emove the coil door before brazing refrigerant connections to prevent damage to paint finish. 3. Fit refrigerant lines into coil connections and remove the tubing plate and slide plate over the refrigerant lines to assure sufficient room for brazing. 4. einstall tubing plate and door and install the gasket, provided with the unit, over the suction and liquid lines into the tubing plate recess to ensure an air seal around the coil. SeeFigure8. Figure 8 Gasket efrigerant Lines efrigerant Lines Tubing Plate ecessed Area For Gasket 496 01 4109 02 5

Installation Instructions Electrical Connections Electrical shock hazard. Turn FF electric power at fuse box or service panel before making any electrical connections and ensure a proper ground connection is made before connecting line voltage. Failure to do so can result in property damage, personal injury and/or death. All electrical work MUST conform with the requirements of local codes and ordinances and the National Electrical Code NFPA 70 current edition. The low voltage transformer and the fan control are standard on all models and are prewired at the factory. Line voltage connections are made to the heater accessory or the lugs on the No Heat Kit. vercurrent Protection The power supply wiring to the unit MUST be provided with overcurrent protection. Governing codes may require this to be fuses NL or circuit breakers. For blower cabinets without heaters, a 15 amp circuit may be used. No Heat Kit Installation If electric heat is not used, install accessory No Heat Kit. 1. Locate adapter and filler plates, with screws inside package. 2. Attach adapter plate and filler plate to bracket if required to match cabinet, efer to Figure 9. 3. Secure the No Heat Kit accessory with four screws. 4. Connect the plug from No Heat Kit wiring into the receptacle on the control board on the side of the cabinet. CAUTIN Do not attempt to force plug as it only fits one way. Line oltage Connections Line voltage wiring may be brought into the unit through the top right--hand corner or the right--hand side panel. The correct hole size required by the conduit fitting must be punched at the pilot hole location. Plug the unused pilot hole with a hole plug (supplied with unit). Fan Coils Connect field wiring to appropriate terminals on electric heater or lugs on the No Heat Kit. All line voltage connections must be made with copper wire. Line oltage Connection 1. Provide line voltage power supply (208--240) from a separate circuit(s). Size per table or table in heater manual. 2. Connect line voltage to the lugs on the No Heat Kit., or to circuit breakers or wire leads from heaters. efer to Figure 9 and wiring diagram. Grounding Connection Use a copper conductor(s) from the ground lug on the No Heat Kit or ground lugs on the electric heater to a grounded connection in the electric service panel or a properly driven and electrically grounded ground rod. Figure 9 Low oltage Connections Filler Plate (4-5 Ton) Adapter Plate (3 Ton) No Heat Kit Electrical Controls Lugs for Line oltage and Ground Connections Matching eceptacle For No Heat Kit or Electric Heater Maximum ecommended vercurrent Supply Wire Supply Nominal Maximum Branch Protective 75 0 C. Copper Ground Supply Circuit Circuit Motor Motor Total Circuit Device Max. Wire olts Phase Hertz No. H.P. AMPS. AMPS. Ampacity* (AMPS.) No. Size Length (Ft) No. Size 240 1 60 Single 1/2 3.3 3.3 3.8 15 2 14 104 1 14 208 1 60 Single 1/2 3.3 3.3 3.8 15 2 14 90 1 14 240 1 60 Single 1 6.6 6.6 6.9 15 2 14 104 1 14 208 1 60 Single 1 6.6 6.6 6.9 15 2 14 90 1 14 * Based on maximum ampacity allowed by Magellan control program. 6 496 01 4109 02

Fan Coils Low oltage Control Connections The 24 volt power supply is provided by an internally wired low voltage transformer which is standard on all models. If power supply is 208 volt, the low voltage transformer must be rewired to the 208 volt tap. See the unit wiring label. Field supplied low voltage wiring can enter the unit on the top left hand corner* or the left hand side panel. When using the left hand side panel entrance, the low voltage wiring must be fed through the entrance hole in the bottom of the blower deck into the control area. Install the strain relief bushing (supplied with unit) in the selected hole and a hole plug (supplied with unit) in the unused hole. Connect the field wiring at the screw terminals of the control board. efer to Figure 9. Keep the low voltage wiring as short as possible inside the control box. Complete connections between indoor blower, outdoor section, indoor thermostat and electronic outdoor thermostat (accessory) according to instruction provided with the Condenser Installation Instructions or those provided with the accessory and refer to Figure 9. Figure 10 Thermostat G W Typical Low oltage Schematic Cooling nly W 2 W 1 G H C Indoor Blower utdoor Unit Air Conditioner - Adding Control for 80% Airflow Humidistat or utdoor Thermostat W 2 W 1 G H C Indoor Blower Adjusting Thermostat Anticipator Installation Instructions Set the heat anticipator of the thermostat to the proper value. See instructions provided with the thermostat before making this adjustment. Heater Size -- KW 05.24 07, 10.32 Anticipator Setting Adding Humidistat or utdoor Thermostat Adding a humidistat or outdoor thermostat allows the airflow to be reduced to 80% of normal allowing greater humidity control. Humidistats are preferred but an outdoor thermostat can be used but can only be set based on temperature. Suggested starting point is 85 F, but this will vary depending on several factors. The control must be wired differently on air conditioners and heat pumps. n air conditioners connect to and Dehum terminals H, ref Figure 10. HEAT PUMPS NL: Heat pumps must use only the outdoor thermostat, because it is powered instead of just performing a switching function. This allows it to be out of the circuit when continuous circulation is desired, which is required for the system to operate on Fan nly for circulation, which is 60% airflow. n heat pumps connect to and Dehum terminals H, and C and to power the outdoor thermostat. ref Figure 11. Electric Heater Staging The heater elements are turned on in increments. efer to Heater Staging Table in the Heater Installation Manual. In addition on heaters larger than 5KW, the heat can be staged (1st & 2nd) either through an indoor thermostat or by using an outdoor thermostat. This satisfies staging requirements imposed by some electric utilities on heaters larger than 6 kilowatts. A control signal (24) from W1 on the Indoor T stat to W1 on the control board energizes the 1st stage of heat. A control signal (24) to W2 on the control board energizes the second stage of electric heat. To turn N both stages at the same time, using one control signal, W1 and W2 are jumpered together. If the indoor thermostat does not have staging capabilities, accessory electronic outdoor thermostats are available that will control two stages of electric heat. Motor Speeds and Airflow See Figure 12 and Page 8. The motor speed can be set on one of eight speeds and the air flow will adjust between 60%, 80% and 100% depending on settings. Time N / FF settings can also be adjusted. Determine coil static pressure drop, consult coil manual and measure duct system static pressure, then determine required speed setting from blower charts. For Cooling -- Set switches 6, 7, and 8 on the motor end bell to position 0 (off) or 1 (on) as specified on blower charts. For Heating -- Set switches 3, 4, and 5 on the motor end bell to position 0 (off) or 1 (on) as specified on blower charts. Set switches 1 and 2 to position 0 (off) or 1 (on) as specified in Figure 12 to control Fan delay N -- FF. NTE: Power must be completely FF to unit any time switch settings are changed or settings will not take effect. 496 01 4109 02 7

Installation Instructions Fan Coils Figure 11 Typical Low oltage Control Schematic Thermostat G W Cooling with Electric Heat utdoor Unit G C W 1 W 2 Staging Thermostat Heat Pump with Electric Heat W utdoor Unit W 2 W 1 G H C Indoor Blower Air Conditioner - Adding Control for 80% Airflow W 2 W 1 G H C Indoor Blower Heat Pump - Adding Control for 80% Airflow W 2 W 1 G H C Indoor Blower W 2 W 1 G H C Indoor Blower Humidistat or utdoor Thermostat utdoor Thermostat Figure 12 Motor Speeds See next page for switch positions and CFM range Time Delay Select Heat CFM Select Cool CFM Select 1 Positions (on) 1 2 3 4 5 6 7 8 0 Switch (off) Motor Controller mounted to blower housing Available Selections: Time Delays: 00 0 sec. on/ 60 sec. off (default) 01 0 sec. on/ 90 sec. off 10 0 sec. on/ 30 sec. off 11 0 sec. on/ 0 sec. off 8 496 01 4109 02

Fan Coils Installation Instructions CFM 1400 1200 1000 800 600 400 001 010 000 011 FC24 200 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 EXTENAL STATIC 101 100 110 111 NTE: Both sets of switches must be set Dip Switch Settings are set at switches 6,7and8for Cooling, 3, 4, and 5 for Heating. Dip Switch Settings 000 Highest Speed 111 Lowest Speed For Heat Pumps both sets of switches should be set the same. For electric heat the heat switches can be set to obtain a comfort level within the specified heat rise of the unit. 1600 Dip Switch Settings - 000 Highest Speed 111 Lowest Speed Dip Switch Settings are set at switches on the motor controller. 0 is FF Position, 1 is N Position FC36 1400 CFM 1200 1000 800 600 400 200 000 001 010 011 100 101 110 111 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 External Static 496 01 4109 02 9

Installation Instructions Fan Coils 2200 FC48 NTE: Both sets of switches must be set SCFM 2000 1800 1600 1400 1200 000 001 010 011 Dip Switch Settings are set at switches 6,7and8for Cooling, 3, 4, and 5 for Heating. Dip Switch Settings 000 Highest Speed 111 Lowest Speed 1000 800 600 400 100 101 110 111 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 External Static For Heat Pumps both sets of switches should be set the same. For electric heat the heat switches can be set to obtain a comfort level within the specified heat rise of the unit. Dip Switch Settings - 000 Highest Speed 111 Lowest Speed Dip Switch Settings are set at switches on the motor controller. 0 is FF Position, 1 is N Position FC60 2200 2000 SCFM 1800 1600 1400 1200 1000 800 600 000 001 010 011 100 101 110 400 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 External Static 10 496 01 4109 02 111

Fan Coils Installation Instructions FILTE STATIC PESSUE DP* *WASHAE DISPSAE CFM MDEL FILTE SIZE FILTE SIZE 600 800 1000 1200 1400 1600 1800 2000 FC24 14 1 / 4 X20 1 / 4 14 X 20.05.09.13.19 -- -- -- -- -- -- -- -- -- -- -- -- FC36 17 31 / 4 X20 1 / 4 18 X 20 -- -- -- -- -- -- -- 0.09 0.12 0.17 0.22 -- -- -- -- -- -- FC48 / FC60 24 3 / 4 X20 1 / 4 25 X 20 -- -- -- -- -- -- -- -- -- -- -- -- -- 0.09 0.11 0.14 0.18 Air Flow Check For proper system operation, the air flow through the indoor coil should be between 350 and 450 cfm per ton of cooling capacity. The air flow through the unit can be determined by measuring the external static pressure to the unit and selecting the motor speed tap that will most closely provide the required air flow. 1. Set up to measure external static pressure at the supply and return duct connections (Figure13). 2. Drill holes in the ducts for pressure taps, pitot tubes, or other accurate pressure sensing devices. Figure 13 Static Pressure Check Supply Indoor Section Incline Manometer eturn 3. Connect these taps to a level inclined manometer or draft gauge. 4. Ensure the coil and filter are clean, and all the registers are open. 5. Determine the external static pressure with the blower operating. 6. efer to the Air Flow Charts, pages 9 & 10 to find the Dip Switch Speed setting that will most closely provide the required air flow for the system. 7. efer to Motor Speeds and Airflow in these instructions if the speed is to be changed. 8. echeck the external static pressure with the new setting, and confirm speed switch selection. Temperature ise Check Temperature rise is the difference between the supply and return air temperatures. NTE: The temperature rise can be adjusted by changing the heating speed tap at the unit s blower terminal block. A temperature rise greater than 60 0 F (33.3 0 C) is not recommended. 1. To check the temperature rise through the unit, place thermometers in the supply and return air ducts as close to the unit as possible. 2. pen ALL registers and duct dampers. 3. Set thermostat Heat--Cool selector to HEAT. 4. Set the thermostat temperature setting as high as it will go. 5. Turn electric power N. 6. perate unit AT LEAST 5 minutes, then check temperature rise. NTE: The maximum outlet air temperature for all models is 200 0 F (93.3 0 C). 7. Set thermostat to normal temperature setting. 8. Turn electric power FF. 9. Be sure to seal all holes in ducts if any were created during this process. Maintenance Filters Filters must be cleaned when they become dirty. Inspect at least once per month. The frequency of cleaning depends upon the hours of operation and the local atmospheric conditions. Clean filters keep unit efficiency high. Lubrication The bearings of the blower motor are permanently lubricated. Condensate Drains During the cooling season check the condensate drain lines to be sure that condensate is flowing from the primary drain but not from the secondary drain. If condensate ever flows from the secondary drain the unit should be promptly shut off and the condensate pan and drains cleaned to insure a free flowing primary drain. 496 01 4109 02 11

Installation Instructions Fan Coils PWE SUPPL: 208/230-1-60 USE CPPE CNDUCTS NL. KE: HIGH LT; -------- LW LT. G/y W G MT G/y GD GD CNTL G BASE PTINAL N-HEAT KIT AMF001NH INSTALLED *SEE INSTALLATIN MANUAL F PPE HEATING AND CLING FACT PE-SET SPEED CNNECTINS F U UNIT. 1 1 W1 W2 G H C FUSE * CM 24AC G G AMFK07AH / AMFK10AH ELECTIC HEATE FAN BD CNTL TFM SEC B W G AMFK05AH ELECTIC HEATE CM TFM PIMA 240 FAN CM 2 SP L FAN SPD PTINAL GD G G GD 5 Kw 7.5 & 10 Kw GD 240 208 CM TANS FF FF FF FF L2 L1 24 CM L2 L1 15 Kw 1 W 1 G G G G G W AMFK20AH ELECTIC HEATE AMFK25AH ELECTIC HEATE G G G GD GD 20 Kw GD GD GD GD FF FF FF FF L4 L3 L2 L1 25 Kw FF FF FF FF FF FF L6 L5 L4 L3 L2 L1 30Kw 1 G G G AMFK14AH ELECTIC HEATE *AMFK15AH ELECTIC HEATE (2 S) GD GD FF FF FF FF L1 L2 L3 L4 W G 1 W W AMFK30AH ELECTIC HEATE GD GD 1087574 FF FF FF FF FF FF L1 L2 L3 L4 L5 L6 12 496 01 4109 01

Fan Coils Installation Instructions eplacemaent Parts 496 01 4109 01 13

Installation Instructions Fan Coils eplacemaent Parts KE N. DESCIPTIN PAT NUMBE 1 Coil, Evap EXA24B15A ******* 1 1 EXA36F19A1 ******* - 1 1 EXA48N26A1 ******* - - 1 1 EXA60N26A1 ******* - - - 1 2 Manifold, Evaporator Suction 1083246 1 2 1083253-1 2 1083310 - - 1 2 1083258 - - - 1 3 Distributor 1062727 1 1 1 1 4 alve, Expansion 1082871 1 1 4 1082873 - - 1 4 1087341 - - - 1 6 Distributor Assembly ******* 7 Pan, Drain, 15" 1082775 1 7 19" 1082776-1 7 26" 1085353 - - 1 1 8 Pan, Drain Horizontal 1082619 1 1 8 1082621 - - 1 1 9 Control, Fan Timer 1085914 1 1 1 1 10 Transformer 1082611 1 1 1 1 11 Motor, Blower 1012478 1 1 11 1012479 - - 1 1 12 Mount, Blower Motor 1050254 1 12 1066700-1 12 1057955 - - 1 1 13 Wheel, Blower 600585 1 13 600587-1 13 96839 - - 1 1 14 Control, Motor 1012476 1 1 14 1012477 - - 1 1 A Baffle, Top 1082955 1 1 1 A 1082956 - - - 1 B Plate, Triangular 1082779 2 B 1082924-2 B 1082782 - - 2 2 C Plug, Drain Pan 1083241 4 4 4 4 D Plug, Drain Pan 1082965 1 1 1 1 F Wrapper 1082601 1 F 1082825-1 F 1082827 - - 1 1 H Plate, Tubing 1085601 1 1 1 1 K Grommet, Tubing Plate 1085603 1 1 K 1085602 - - 1 1 FC2400C2 FC3600C2 FC4800C2 FC6000C2 KE N. DESCIPTIN PAT NUMBE FC2400C2 FC3600C2 L Bracket, Coil Hold Down 1082602 1 1 1 1 Panel, ear Blower Deck 1082604 1 1082844-1 1082846 - - 1 1 P Panel, Front Blower Deck 1086694 1 P 1085372-1 P 1085374 - - 1 1 Q Panel,Side Blower Deck 1082622 2 Q 1082847-2 Q 1082849 - - 2 2 Bracket, Control Fan 1085371 1 1 1 1 S Bracket, Drain Pan 1082609 1 S 1082927-1 S 1082929 - - 1 1 Panel, Top 1082610 1 1082835-1 1082837 - - 1 1 W Housing, Blower 1087343 1 W 1087193-1 W 1087194 - - 1 1 X Panel, Blower Cutoff 1082607 1 X 1082616-1 X 1082949 - - 1 1 Z1 ail, Blower.H. 1085504 1 1 1 1 Z2 ail, Blower L.H. 1085521 1 1 1 1 AA Door, Coil Access 1085189 1 AA 1085190-1 AA 1085192 - - 1 1 BB Door, Blower Access 1085301 1 BB 1082838-1 BB 1082840 - - 1 1 CC Door, Filter Access 1085194 1 CC 1085195-1 CC 1085197 - - 1 1 DD Plate, Heater Adapter 1084606-1 1 1 EE Plate, Heater Filler 1084608 - - 1 1 FF Clamp. Tube 1063118 1 1 1 1 GG Shield, Condensate 1083333 2 2 2 2 JJ Adapter, Male (Drain) 1085010 1 1 1 1 )( Harness, Wire 1087518 1 1 1 1 )( Harness, Wire 1087519 1 1 1 1 )( Harness, Wire 1087049 1 1 1 1 )( Manual, Installation 49601410900 1 1 1 1 FC4800C2 FC6000C2 14 496 01 4109 01