Specialists in Tunnel Fire Protection

Similar documents
Specialists in Tunnel Fire Protection

Innovative Solutions for Active Fire Protection in Road/Rail Tunnels and Underground Facilities

OUR COMMITMENT. "To provide our customers with the best possible service, the highest quality products and the right solution for their needs"

Video Imaging Detection Systems

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

Tel Web: dyayan.com

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

Emergency shutdown systems. Procedures for bypassing ESD s

FIRE AND FIRE FITTING By Mr. Prashant Sansare

Fire suppression systems for server rooms and data centres

SOLIT PROJECT: WATER MIST FIRE SUPPRESSION SYSTEMS AS PART OF THE TUNNEL SAFETY SYSTEM

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

FIXED FIRE FIGHTING SYSTEMS IN TUNNELS INTEGRATION AND COMPENSATION

Risk Management of Fire using Video Based Detection

FoamFatale INTRODUCTION OF A NOVEL HIGH END TECHNOLOGY FOR LARGE ATMOSPHERIC STORAGE TANK FIRES. TFEX 1 Ltd.

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

NEBOSH International Technical Certificate in Oil and Gas Operational Safety

Foam Products ENGLISH

COMPENSATORY EFFECTY OF FIXED FIRE FIGHTING SYSTEMS IN TUNNELS

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Jonathan Redding Area Sales Manager FOGTEC Fire Protection Cologne, Germany

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

IMPROVING VENTILATION AND PASSIVE PROTECTION WITH FFFS

TUNPROTEC. Active Tunnel Fire Protection

FIRE SUPPRESSION SYSTEM

Explosion Protection Engineering Principles

Global Marine Solutions and Services From Ship to Shore Single Source Providers for Fire, Security, Life Safety

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk

SECURITY BLANKET Foam Fire Protection Products

What is HI-FOG? The natural enemy of fire

Intelligent Security and Fire Solutions. Southern Africa

High flying fire protection HI-FOG for aircraft hangars

ODS & SGG Alternatives for the Fire Protection Industry 2018

WATER MIST CONVENTION AND EXHIBITION

Guidance on Video Smoke Detection Technology (VSD)

Fire Suppression Systems

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

and Sprinkler System in Resalat Tunnel of Tehran

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

that sense s of ecurity

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

The first tunnel fire. Benefits of fire

AUTOMATIC FIREFIGHTING SYSTEMS IN HOSPITALS

Affordable fire suppression solutions

automatic FiReFighTing SYSTeMS in PainT booths

Fire protection for buildings

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

STATE-OF-THE-ART FLAME, SMOKE AND INTRUSION VIDEO DETECTION TECHNOLOGY FIRE DETECTION AND VIDEO SURVEILLANCE

Safety is more than just being careful: it

Our Mission. About Us. To create awareness of the essentiality attached to a firefighting system, as an important requisite in everyday life and loss

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

FINDINGS FROM FIRE TESTS IN TUNNEL CONSTRUCTIONS WITH VENTILATION SYSTEMS AND FIXED FIRE SUPPRESSION SYSTEMS

Water Mist Fire Suppression

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

Hi, welcome to the topic on Fire Detection and Alarm Systems. This topic forms one of the critical knowledge areas for prospective fire safety

Aspirating Smoke Detection (ASD) Systems Fire Detection

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS

Performance Based Fire Protection With Water Mist

Proven Fire Fighting Efficiency for Large Transformers with High Pressure Water Mist

AUTOMATIC FIRE EXTINGUISHING SYSTEM for TUNNEL PROTECTION with SPREAD REMOTE CONTROLLED MONITORS (TUDEM-LEGIO)

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

Press Presse Press Presse

What extinguishes fires without pressure peaks?

RIM SEAL SYSTEMS E-BOOK

PHIREX AUSTRALIA. FOGEX & MISTEX WATER MIST FIRE PROTECTION

DIPL Solutions and Services

ADPRO. Integrated Security and Surveillance Solutions. Intelligent - Flexible - Reliable

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

Fire, Safety & Damage Control Systems for Naval Applications

HART XL High Sensitivity Smoke Detection

Rick Seidel Fike Corporation Regional Sales Manager

STATE-OF-THE-ART FLAME, SMOKE AND INTRUSION VIDEO DETECTION TECHNOLOGY FIRE DETECTION AND VIDEO SURVEILLANCE

Protezione antincendio di dati e business critical assets nei Data Centers

MORE THAN JUST FIRE PROTECTION

The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring)

XC10 combined fire detection and extinguishing control

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

Nessie High Pressure Water Mist Components for Fire Fighting

Before proceeding with the selection process, let s briefly look at the various explosion protection options:

Explosion Protection of an Armoured Vehicle Crew Compartment with Water Mist. Andrew Kim and George Crampton

Tunnel. Neumarkt. Stationary Fire Protection Case Study

Quantitative risk assessment for a fire suppression system in the New Tyne Crossing. Dr Fathi Tarada

Minifog PressProtect Fire protection solutions for industrial presses BRANCH SOLUTION

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.


XC10 combined fire detection and extinguishing control

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

CCTV, HOW DOES IT WORK?

Fire Protection and Safety in Tunnels Conference Opening Remarks. Dr Fathi Tarada Secretary, PIARC Tunnel Operations Committee

Transcription:

Specialists in Tunnel Fire Protection

Specialists in Tunnel Fire Detection 3 Underground transport facilities are sensitive links in the economic chain that carry thousands of people and tons of goods every day and they are increasingly more important to society. A breakdown in operations can have catastrophic consequences, hence the need for comprehensive safety precautions and ensuring that the design, installation and maintenance of these systems is of the highest standard. By far the greatest risk is an uncontrolled fire, as fires represent great danger to life due to toxic combustion gases, high temperatures and loss of visibility. In addition, the limited means of escape available together with panic reactions spell disaster for any tunnel operator and the future viability of the transport facility. DETECTION IN TUNNELS In today s complex industrial environments, the potential for downtime and financial losses caused by overheat and fire can be disastrous if not detected and located quickly. LINEAR HEAT DETECTION Linear Heat detection is increasingly becoming the first choice in fire protection. With ever increasing complex application and the potential for loss and downtime, the right choice is critical to business continuity. In many applications traditional point type detection is not used in the way and for the purpose they were designed. Linear heat detection has become a preferred alternative for many of these applications. DIGITAL LINEAR HEAT DETECTION Digital linear heat detection cable is a conventional style heat detector which is capable of detecting a fire along the entire length of the cable using a maximum alarm threshold. Its versatility and simplicity is an economic way to provide rapid detection of fire at an early stage. FIBRE OPTIC LINEAR HEAT DETECTION Are capable of recording temperatures along the entire length of the sensor cable providing continuous real time temperature profile of the environment in which the system is installed. These systems are capable of detecting and locating a fire or overheat conditions over distances up to 10 km. MICRO CHIP LINEAR HEAT DETECTION Rapidly and accurately detect temperature changes at ±0.1 C increments along its length, with multiple alarm thresholds including fixed point, rate of rise and pre alarm. The system controllers include the ability to program various alarm thresholds which interface with fire control and building automation systems upon fire alarm. In turn providing real time data of any fire scenario to operational personnel as well as accurately operating the fire suppression systems to activate where required. FLAME DETECTION Flame detectors provide high speed detection of flaming fires with the option of an in-built CCTV camera for real time footage of fire scenarios. These detectors are capable of operating in the harshest environmental conditions and offer a solution for virtually any application. With a high immunity for false alarms, as well as various performance and safety approvals, flame detectors are a reliable alternative for fire detection throughout tunnels including sump areas within the structure. VIDEO IMAGING DETECTION (VID) capabilities. The benefits for VID in a tunnel application, is that, trained tunnel operators have the ability to visually recognise real fire and smoke events and operate fire suppression systems accurately to the location of the fire. As the VID system can detect fire within seconds, supplying vital situational awareness in the form of live video to remotely located control centres, trigger fire alarms, and provide vast amounts of pre-recorded video forensic evidence for future fire investigations. SigniFire is deployed in conjunction with the Fike FSM-IP advanced Network Video Recorder (NVR) platform that can address immediate security needs of your organisation. Large capacity internal storage provides continuous digital video recordings with instant access to current and archived events from virtually anywhere over local and public networks. ASPIRATING SMOKE & GAS DETECTION VESDA very early warning smoke detection solutions provide the earliest possible warning of an impending fire hazard. VESDA buys time to investigate an alarm and initiate an appropriate response to prevent injury, property damage or business disruption. And because VESDA has the industry s widest sensitivity range and multi-level alarms, even minute levels of smoke can be detected before a fire has time to escalate. As the No. 1 ASD brand specified by fire professionals around the world, VESDA is synonymous with reliable, highperformance fire detection. SigniFire cameras can see and recognise smoke and/or flames overlooking large spaces at great distances, whilst also providing video surveillance CATEGORY//Fire Detection

5 WATER MIST PROTECTION OF TUNNELS The protection of people against fire and other risks is one of the major tasks of tunnel designers and operators. Furthermore, the closing of a tunnel for days, weeks or even months after a fire incident can create huge economic losses not only for the operator but also for society as a whole. Intensive research work over the last decade has shown that commonly applied fire protection concepts for tunnels may not provide a sufficient level of safety. Smoke ventilation systems are designed to deal with a specific, limited fire size. Passive fire protection is designed to withstand the effects of fires for a limited time only. It is now accepted that there is a more important need to provide protection for people that may be trapped and trying to escape the smoke and flames. The logical and most effective way to provide suitable protection for tunnels and its users is to install fixed fire fighting systems (FFFS) to mitigate the effects of fires. FOGTEC Tunnel Protection Systems are state of the art Water Mist Systems combining results of the latest research work with the reliability of long term tested components. Modern FFFS Technology with Low Investment Costs: FOGTEC technology makes it possible to reach a high safety level with low investment costs. Revolutionary cost benefit analyses have shown that investing in FFFS will give return on investment over the design lifetime of the tunnel. This is due to low life cycle costs of modern FFFS technology. LIFE SAFETY & ASSET PROTECTION Purpose of (FFFS): High pressure Water Mist Systems (WMS) are installed to improve both life safety and asset protection within tunnels. As WMS are active fire fighting methods they achieve this by: 1. Improving the self-rescue conditions - Immediate cooling effect to provide lower temperatures within the fire zone. Reducing smoke production significantly by controlling and suppressing the fire. Binding smoke and soot. 2. Improving access and operating conditions for fire and rescue services - Limiting Heat Release Rate (HRR) with suppression and control Lower temperatures Blocking radiant heat transfer. 3. Prevention of fire spread between vehicles - Limited fire area - Limited HRR. 4. Limiting structural damages to the tunnel - Lower temperatures - Limited HRR and fire area UPTUN Fire Test - Temperature Profile The benefits of FFFS are especially evident in cases where loaded semi-trailers or buses are involved in the fire. Both the UPTUN and SOLIT research programs showed the distinct benefits in such scenarios. The SOLIT research program used 150MW-200MW HRR (approx.) class A mock-up as the design fire load. Although the fire load represented a typical loaded semi trailer scenario similar to many catastrophic fires, all of the above mentioned objectives were successfully reached. It has to be noted that modern FFFS are used for fire control and suppression purposes, therefore HRR can be even tens of megawatts in peak output. However, the fire is encapsulated with water mist and more importantly heat / temperatures are kept under control. Water mist Systems are able to control/ suppress even large fires and systems are capable of fire encapsulation and temperature limiting which provides safe conditions for emergency fire services. grouped in sections or zones that can be individually activated. As a result of the system s 200 bar pressure, long pipe runs are easily accommodated and costs are kept low due to smaller pipe sizes. FOGTEC Watermist Systems for Tunnels generate a fine water mist around the fire. Very small water droplets provide an efficient cooling mechanism to mitigate the effects of the fire. High Pressure Water Mist nozzles are installed throughout the tunnel and are Pumping systems are available as diesel and electrically driven units. Compact state of the art design avoids the use of multiple small pumps being connected in parallel. Thus, reliability levels are high and service and WATER MIST SYSTEM ARCHITECTURE 1. 2. 3. FOGTEC s Tunnel Research: FOGTEC operates its own research facilities including fire test laboratories. A number of research projects specifically designed for the protection of tunnels have been carried out by FOGTEC over the last 10 years, providing a unique and proven basis for design. CATEGORY// Water Supression THE SMARTER WAY OF FIRE FIGHTING WITH WATER MIST The water supply main is pre- pressurised to section (zone) valves in order to reduce water delivery time. Each fire suppression zone is fitted with an automatic section (zone) valve. Fogtec nozzles are specially engineered and fire tested for tunnel applications in extreme fire conditions, these nozzles are designed to generate fine water mist droplets that provide a superior cooling effect which is required to achieve a sharp reduction in the fire heat release rate. Example from real installations These pictures show a typical water mist installation in the tunnel (3D model) and an activated system in the real tunnel. maintenance requirements are low. FOGTEC Systems are easily integrated into tunnel management systems for optimal interconnection with other safety systems such as ventilation and emergency warning systems.

FOAM FIRE FIGHTING Fire-fighting foam is an aggregate of air-filled bubbles formed from aqueous solutions and is lower in density than flammable liquids. It is used principally to form a cohesive floating blanket on flammable and combustible liquids and prevents or extinguishes fire by excluding air and cooling the fuel. It also prevents reigniting by suppressing formation of flammable vapors. It has property of adhering to surfaces, which provides a degree of exposure protection from adjacent fires. TYPICAL FOAM APPLICATION AREAS Localised Applications: Car Fire, (Engine, Brakes, Tyre,). Truck Fires ( Tyre, Engine bay, Brakes, Trailer.) Hydrocarbon Spills. Hydrocarbon Catchment Sump/ Run off Areas: Tunnel Low point Run off areas Hydrocarbon Sumps Catchment separators FOAM ADVANTAGES IN LOCAL APPLICATIONS Localised Rapid response Spill/ Fire application Rapid Suppression (knock down) Foam Blanket Vapour containment Enhanced burn back resistance Personal Safety increased through proximity of hose reel throw distance Water Enhancement = reduced water consumption FIXED FOAM SYSTEM ADVANTAGES IN CATCHMENT/ CONTAINMENT AREAS Early Detection ( Hydrocarbon or Flame Detection system) Foam Blanket Vapour containment Rapid Suppression (knock down) Enhanced burn back resistance FIREDOS PROPORTIONING FireDos is the revolutionary proportioning system that operates without any external power supply. Drive for the unit is provided solely by the water supply being used to fight the fire. The rotation speed of the drive motor is proportional to the volumetric flow rate, thereby enabling the FireDos unit to accurately proportion product concentrations from as low as 0.1% up to 6%. It is capable of handling practically any fluid from a flow rate of 10 l/min. to 20,000 l/min. and is not affected by fluctuations in flow or pressure. FireDos is cost effective and will also eliminate the need for installation of expensive foam concentrate pumps, bladder tanks and associated equipment The foam hose reel and Hydrant cabinet system shown is specifically designed for use in tunnel environments and utilise the FireDos proportioning system to ensure accurate proportioning of foam concentrate regardless of fluctuation in the supply pressure and flow. TUNNEL PROJECTS AUSTRALIA & NEW ZEALAND Fire Protection Technologies have provided and continue to provide design, engineering, fire suppression products, fire detection products, and commissioning services for new tunnel projects, upgrades and refurbishments. Our experienced design and engineering team is intimately aware of the stringent engineering requirements that apply to tunnels. PARTICIPATION IN STANDARDISATION & RESEARCH PROGRAMS Fire Protection Technologies and FOGTEC are very active in and throughout the world in tunnel societies and participate in a number of different research programs, standards, committees and working groups. NFPA 502 (Tunnels) NFPA 750 (Water Mist) ITA - COSUF Australasian Tunneling Society Technical Advisory Committee (TC23) Tunnel Fire Safety International Water Mist Association M30 Tunnel Spain Silver Forest Tunnel Russia New Tyne Crossing UK Eurotunnel France / UK Eastern Busway - Aus Airport Link - Aus Mount Victoria - NZ Northern Busway - Aus Clem7 Motorway - Aus 7 Victoria Park Tunnel - NZ CATEGORY// Foam Supression Terrace Tunnel - NZ

PRODUCTS: Gaseous Suppression Inert Gas (IG-01, IG-55, IG-100, IG-541) Novec 1230 Fluid (FK-5-1-12) FM-200 / NAF S 227 (HFC-227ea.) Ecaro 125 / NAF S 125 (HFC-125) Carbon Dioxide (C02) Hybrid Systems (N2 / Water) Pressure Relief Vents Enclosure Integrity Testing Equipment Pipe & Fittings Water Suppression Water Mist - High Pressure Water Mist - Intermediate Pressure Water Mist - Low Pressure Hybrid Systems (Water / N2) Monitors & Delivery Systems High Speed Deluge Foam Suppression Foam Concentrates Foam Proportioning Foam Delivery Systems Foam Concentrate Testing Explosion Protection Explosion Suppression Explosion Isolation Explosion Vents & Pressure Relief Spark Suppression Explosibility Testing Fire Detection Linear Heat Detection - Digital Linear Heat Detection - Fibre Optic Linear Heat Detection - Micro Chip Flame Detection Video Imaging Detection Spark Detection Control & Indicating Equipment Thermal Imaging Detection Aspirating Smoke Detection Military & Defence Military Vehicles Naval Vessels Special Applications Micro Environment Oxygen Reduction Kitchen Protection Systems Dry Chemical Vehicle Systems Compressed Air Foam Marine & Offshore Vapour Mitigation Support Services Design / Engineering Technical Support Services & Testing Head Office Unit 1, 251 Ferntree Gully Road Mt Waverley VIC 3149 Brisbane Office Unit 7, 93 Rivergate Place Murarrie QLD 4172 Perth Office Unit 4, 35 Colin Jamieson Place Welshpool WA 6106 Sydney Office Suite 2D, Pegasus Business Centre 3 Racecourse Road, West Gosford NSW 2250 New Zealand Auckland Office Unit 2, 13 Airborne Road Albany North Shore 0632 New Zealand +64 9 415 5488 www.fire-protection.net.nz South East Asia Regional Head Office 11 Yishun Industrial Street 1, #03-96 Singapore, 768089 +65 6635 7060 www.fire-protection.com.sg 1300 742 296 Int: +61 3 8542 8900 www. Every solution for your special hazard needs