System Accessories, LCD Annunciators

Similar documents
TrueAlert Addressable Notification

Releasing System Peripherals

LifeAlarm Fire Alarm Controls

LifeAlarm Fire Alarm Control Panels

TrueAlarm Analog Sensing

4007ES Fire Control Panels

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances

TrueAlert ES Addressable Notification Appliances

4007ES Fire Control Panels

4007ES Fire Control Panels

TrueAlarm Analog Sensing

TrueAlert Multi-Candela Notification Appliances

Multi-Point Peripherals

Z-20 Fire Control Panels

TrueAlarm ES Analog Sensing

TrueAlert Addressable Notification Appliances

Multi-Application Peripherals

TrueAlarm Smoke Detectors

TrueAlert Addressable Notification Appliances

TrueAlert Notification Appliances

Addressable IDNet Isolator Installation Instructions

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

Fire Alarm System Accessories

4120 Fire Alarm Network Reference

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC Listed, FM Approved* Features

TrueAlarm Addressable Fire Alarm Control Panels

Specification/ Data Sheet

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

4007ES and 4007ES Hybrid Fire Alarm Systems Installation Manual

TrueAlert Multi-Candela Notification Appliances

Print Specification. Publication. Instructions. Specific requirements. General requirements

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

TrueAlarm Fire Alarm Controls

Fire Control Units. Addressable Fire Detection and Basic Control Unit Modules and Accessories. UL, ULC Listed, FM Approved* Features

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

Rev. B. TrueAlert Addressable Controller Application Manual

ALARMS Fire Alarm Priority 2 Alarm. Fire Alarm Priority 2. Ack Event Time Enable Disable Emergency Operating Instructions.

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

/5121/5122 TrueAlert Power Supply Installation Instructions

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

SIGA-CC1 Single Input Signal Module Installation Sheet

4100U City and Relay Cards Installation Instructions

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

Panel Remote Annunciators Installation Instructions

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Intelligent Security & Fire Ltd

FMR Installation Instructions. Addressable Fire System Controller

IDNet and MAPNET II Addressable Devices

Addressable NAC Output Module D327A

Multi-Point Peripherals

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

Fire Control Units. Addressable Fire Detection and Control Basic Control Unit Modules and Accessories. UL, ULC Listed; FM Approved* Features

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

TrueAlarm Fire Alarm Systems

Multi-Application Peripherals and Accessories

Fire Control Panels. Basic Panel Modules and Accessories

TrueAlarm Analog Sensing

SLVMC - Oncology & Infusion Remodel & Add 17D /4/2017

Installation Instructions Model SSD-C-REM

R Series Remote Annunciators and Expander Installation and Operation Guide

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

good things in small packages

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

Fire Alarm Network Reference

Operator s Manual Part: InfoAlarm Product: 4100U, 4100ES Rev. B

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

4100ES Fire Control Panels

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

NBG-12LR and NBG-12LRA

Fire Control Panels. Addressable Fire Detection and Control Emergency Voice/Alarm Communications Equipment

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

TECHNICAL DATA OBSOLETE

Functional Performance Test

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

/9308 External Battery Chargers Installation Instructions

Integrated Security Solutions

ANNUNCIATOR FIXED MODULE

PN:51264:A2 ECN Remote Fire Annunciator FDU-80. Document /14/00 Rev: A.

Integrated Security Solutions

Concerns: Affects: Dated: June 12, SECTION 1: GENERAL Scope Work Included... 3

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

D1255RB/D1256RB/D1257RB

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

ECC-50/100C. Emergency Command Center

Macurco DVP-120 / DVP-120M Detection and Ventilation Control Panel User Instructions

SECTION FIRE ALARM SYSTEMS

MR-2602 Two Zone Fire Alarm Control Panel

GE Security EST Fire & Life Safety. Sensible. EST2 Networkable Fire Alarm Control Panels with Voice Audio

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

Transcription:

System Accessories, LCD Annunciators UL, ULC Approved* A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels Features Fig 1: A4606-9202 LCD Annunciator with Red Trim Fig 2: A4606-9205 LCD Annunciator with Platinum Trim Remote Color Touchscreen LCD annunciators for use with Autocall model 4007ES fire alarm control panels 4.3" (109 mm) diagonal color touchscreen display: Provides the display features of the 4007ES fire alarm control panel at a remote location Convenient and intuitive user interface provides detailed system status and individual point information LED status indicators include Alarm, Priority 2, Supervisory, Trouble, Alarm Silenced, and Status of AC Power at the control panel Supports dual language selection, including unicode character languages Keyswitch is used to enable default access level; additional user access levels are passcode protected; keyswitch and user access levels are configurable Tone-alert sounder provides local audible indication Three programmable control switches with status LEDs and provisions for custom labeling Additional features: Available with platinum or red trim Information is transmitted over a single unshielded twisted pair; separate wiring is required for 24 VDC power Mounts flush on RACO 944, 5-gang electrical box (supplied separately) Up to 6 Color Touchscreen LCD Annunciators per 4007ES fire alarm control panel Mounting box options (ordered separately): Local Annunciation and Control A4606-9202 and A4606-9205 Series LCD Annunciators allows 4007ES fire alarm control panels to provide information and control switches at convenient locations away from the control panel. The color touchscreen LCD with backlighting displays information in clear and descriptive language. (English is standard, other languages can be programmed.) Typical content includes: point status (alarm, trouble, etc.), alarm type (smoke detector, manual station, etc.), number of system alarms, supervisory conditions, troubles, and custom location labels up to 40 characters long. Communications Data communications require a single unshielded twisted pair that supports other annunciators on the same communications channel. Indications Alarm, Priority 2, Supervisory, Trouble, and Alarm Silenced conditions are indicated by dedicated LEDs and a tone-alert audible indication. Each condition will cause the display to present a dedicated acknowledge push-button switch that silences the tone-alert but leaves the LED on until all conditions in that category are restored to normal. Custom Background The 4007ES control panel supports a custom background image that is also displayed on each of the color touchscreen annunciators when status is normal. File types supported are JPG, BMP, GIF, and PNG. Recommended image type is JPG, recommended image size is 480 x 240, and the file size limit is 100 kb. Operation Keyswitch Access Touchscreen display access can be controlled by a keyswitch with a key that is removable only in the disabled position. Access is configurable per annunciator. Enabled Operations When the keyswitch is on, system status indications will be displayed as they occur with individual point detail as programmed at the control panel, and soft keys will be displayed to allow user actions. Screen Backlight When the display has not been touched, and no new system status has occurred for 60 seconds, the backlight dims to 20% of normal brightness. If there is no activity in the system (System is Normal), the standby screen displays current time and date to verify proper operation. If an event occurs, or with the keyswitch activated, and the screen is touched, the backlight returns to full intensity Lamp Test The display menu provides a lamp test feature that when selected, activates the 9 panel LEDs for 5 seconds. Dual-color LEDs will blink alternately. Surface mount boxes in red or platinum Semi-flush mount boxes in red or platinum, may be used for legacy annunciator retrofit applications * Additional listings may be applicable; contact your local product supplier for the latest status.

Product Selection Table 1: Annunciator Product Selection SKU Color A4606-9202 Red A4606-9205 Platinum A2975-9461 A2975-9462 Red Platinum A2975-9463 Red A2975-9464 Platinum Dimensions Annunciator: 13" W x 5.21" H x 2" D (330 mm x 132 mm x 51 mm) Remote Color Touchscreen LCD Annunciator; for flush mounting in a 5-gang RACO 944 Box (reference): 12 ¼" W x RACO 944 box, or equal, supplied separately 4 ½" H x 2 ½" D (311 mm x 114 mm x 64 mm) Surface mount metal box for above annunciators 12 ¼" W x 4 ½" H x 2 ½" D (311 mm x 114 mm x 64 mm) Semi-flush mount metal box adapter for above annunciators; use for mounting on existing 2-gang, 4-gang, 6-gang, or 4" (102 mm) square flush mounted boxes 12 ¼" W x 4 ½" H x 1 ¾" D (311 mm x 114 mm x 44 mm) Note: SKUs ending with BA are assembled in the USA. Table 2: Suppression Products SKU A2081-9044 A2081-9028 Overvoltage Protector, rated for up to 200 ma; use for RUI communications Isolated Loop Circuit Protector (ILCP), rated for 5 A maximum; use for 24 VDC power wiring when above 200 ma Additional Reference Data Sheet AC2081-0016 Data Sheet AC2081-0008 Note: Suppression is required where annunciator communications and power wiring exits and enters a building. Operator Information Page 2

Operator Screen Reference Fig 3: Main Menu Screen provides easy navigation to the function required. Buttons A, B, and C have programmable functions. Fig 4: System Alarm Screen identifies active alarms with custom labels displayed, arrows allow navigation through the list Fig 5: System Trouble Screen identifies active troubles with custom labels displayed, arrows allow navigation through the list Fig 6: Point Information Screen allows review of point details, arrows allow navigation through the information. Page 3

Specifications Table 3: General Operating Specifications Specification Voltage Condition Alarm Current Details Display Active Standby Operating Temperature Range Operating Humidity Range Rating 18 to 32 VDC, system supplied Current Details 124 ma Backlight at full intensity and tone-alert sounding 70 ma Backlight at full intensity, occurs when activity is in process 45 ma Backlight dimmed to 20% of full intensity, occurs after 1 minute of no system activity 32 to 120 F (0 to 49 C) Up to 93% RH, non-condensing at 100 F (38 C) Table 4: Communications Specification For 4007ES Panels Type Capacity RUI (Remote Unit Interface) external annunciator communications line SLC (signaling line circuit) Up to 6 Color Touchscreen LCD Annunciators Table 5: Wiring Requirements Specification RUI Data 2 Standard Wiring Type Unshielded twisted pair (UTP), 18 AWG (0.82 mm ) for most applications, see below Wiring Characteristics 0.58 µf (580 nf) maximum capacitance between conductors; 35 Ω maximum total line resistance Wiring that leaves the building. RUI wiring also requires A2081-9044 Overvoltage Protectors on each end. Wiring run in 500 ft (152 m) or more of conduit. Wiring closely bundled with standard IDNet communications or TrueAlert addressable communications (not required when run with IDNet+ communications). Wiring Applications Requiring Shielded, Twisted Pair (STP) Class B "T-Tap" wiring distance Class X wiring distance Up to 10,000 ft (3048 m) total wiring; up to 2500 ft (762 m) to farthest device Up to 2500 ft (762 m) 2 Power Wiring Terminals for 18 to 12 AWG (0.82 mm2 to 3.31 mm ) wires for 24 VDC system power Earth Wiring A dedicated earth ground connection to the electrical box is required for proper ESD and EMI protection; wire in accordance with NFPA 70 (National Electrical Code) Article 250 Table 6: Mounting Information Item Boxes for Flush Mounting (supplied separately) Page 4 5-gang masonry box, RACO # 944, 2 ½" (64 mm) deep or equal

Table 7: Additional Reference Reference Installation Instructions 579-1172AC AC4007-0001, 4007ES Hybrid AC4007-0002 4007ES Data Sheets Mounting Information Fig 7: LCD Annunciator Mounting Information Note: For surface mounting, use Autocall Surface Mount Box Model A2975-9461 (red) or A2975-9462 (platinum), 2-1/2" deep (64 mm) (ordered separately). For semi-flush mounting, use Autocall Semi-Flush Box Adapter Model A2975-9463 (red) or A2975-9464 (platinum),1-3/4" deep (44 mm) (ordered separately); use for mounting on existing 2-gang, 4-gang, 6-gang, or 4" square flush mounted electrical boxes (supplied separately). Wiring Reference Wiring Reference on page 5 shows A4606-9202 LCD Annunciators. Note: Interconnection Wiring Communication requires 18 to 12 AWG unshielded twisted pair. Power requires two, 18 to 12 AWG wires for 24 VDC system power, plus earth ground to each electrical box. Refer to Install Instructions 579-1172AC for additional wiring specifications. Page 5

2017 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Autocall product supplier for the latest status. Listings and approvals under Tyco Fire & Security GmbH, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA).