TECHNICAL BROCHURE BCPSDWWP R SIMPLEX/DUPLEX WASTEWATER ONNECT STYLE PANELS
PANEL FEATURES Oversize enclosure to accommodate all options. One main disconnect through-the-door with door interlock, prevents the door from accidentally being opened when the disconnect is in the ON position. Pad-lockable in the position only. A manual lockable disconnect feature on the motor overload protector. Lock not provided. Oversize magnetic contactor. Ambient compensated bi-metallic (Class 0) motor overload circuit protector. Instantaneous magnetic trip for short circuit protection. Single-phase protection for three-phase motor. Field adjustable within the amp. range. Control transformer with fused primary and fused secondary on all three-phase. Single-phase 5 volt has a fused control circuit. Through-door hand-off-auto switch, control on/off switch and green pump run light. Numbered and wired control terminal board. Layout and schematic CAD diagrams can be provided upon request. Optional alarm circuit may be field modified to use a 5 volt AC external power source. APPLICATIONS Superior quality simplex and duplex liquid level controller automatically maintains pump operation. Includes high-level alarm warning for a variety of sump, effluent, sewage and water transfer applications with ability to disconnect power at panels. SPECIFICATIONS Ø AND Ø Accepts single or dual power feed. Solid state printed circuit control board with float indicator lights. Main disconnect Alternator for duplex version Alarm horn Auxiliary alarm contacts Capacitors for pumps requiring external motor components are not included or available with this panel. Single Phase Field adjustable for 5 or 0 V, 60 Hz. Adjustable motor overload protectors redundant to built-in overload in single phase motors. Three Phase Field adjustable for 08/0/460/575 V, 60 Hz. 5 V control circuit transformer. Adjustable motor overload protectors. Heaters not required. ORDER NUMBERS Simplex Duplex NOMENCLATURE Character Phase NEMA NEMA 4X Amp Rating st C = Centripro CSD406N CSD406 4.0-6. CSD60N CSD60 6.-0 CSD06N CSD06 0-6 CSD60N CSD60 6-0 CSD05N CSD05 0-5 CSDN CSD - CSD65N CSD65.6-.5 CSD540N CSD540.5-4.0 CSD406N CSD406 4.0-6. CSD60N CSD60 6.-0 CSD06N CSD06 0-6 CSD60N CSD60 6-0 CSD05N CSD05 0-5 CSDN CSD - CDD406N CDD406 4.0-6. CDD60N CDD60 6.-0 CDD06N CDD06 0-6 CDD60N CDD60 6-0 CDD05N CDD05 0-5 CDDN CDD - CDD65N CDD65.6-.5 CDD540N CDD540.5-4.0 CDD406N CDD406 4.0-6. CDD60N CDD60 6.-0 CDD06N CDD06 0-6 CDD60N CDD60 6-0 CDD05N CDD05 0-5 CDDN CDD - nd S = Simplex, D = Duplex rd D = Disconnect Description 4 th = single phase - 5/0 volt = phase - 08/0/460/575 volt 5 th 8 th 6 =.0-.6 amp range, 65 =.6-.5 amp range, 540 =.5-4.0 amp range, 406 = 4.0-6. amp range, 60 = 6.-0.0 amp range, 06 = 0-6 amp range, 60 = 6-0 amp range, 05 = 0-5 amp range, = - amp range (amp ratings of -5 overlap on the last two ratings, when in doubt go to larger range) 9 th 0 th N = Nema, Nothing in 9th and 0th character for Nema 4X. PAGE
SIMPLEX Ø ENCLOSURE LAYOUT ENCLOSURE LAYOUT SIMPLEX Ø ENCLOSURE LAYOUT ENCLOSURE LAYOUT PANEL LAYOUT PANEL LAYOUT AL AL SS- MCP SS- T MCP SS- PL- SS- PL- " MS 4" MS LLC LLC 0" " DUPLEX Ø ENCLOSURE LAYOUT DUPLEX Ø ENCLOSURE LAYOUT ENCLOSURE LAYOUT ENCLOSURE LAYOUT AL PANEL LAYOUT AL PANEL LAYOUT SS- INNER DOOR MCP MCP SS- INNER DOOR T MCP MCP SS- PL- SS- PL- SS- PL- 4" MS MS SS- PL- 6" MS MS LLC LLC " 4" PAGE
SIMPLEX PANEL INSTALLATION SINGLE PHASE 5/0 VAC (FOR 5 VAC, USE TERMINALS L AND N, JUMP L AND N.) SINGLE PHASE 60 HZ AMP RATING S L T L T N GND CONTROL ON- PURPLE S BROWN ON R RESET C FLASH RED WHT L FLASHING ALARM MUTE TEST SONALERT NEU H L N 4 5 6 7 8 J DRY CONTACTS FOR SEPARATE 0 VAC CONTROL POWER SUPPLY, REMOVE JUMPER (J) FROM TERMINALS (H) AND (L). CONNECT 5 AMP MAX. PROTECTED 0 VAC SUPPLY TO TERMINALS (L) AND (N). WITH THE NEUTRAL OF THE SUPPLY TO (N). FLOAT ON FLOAT ALARM FLOAT FOR USE WITH WIDE ANGLE FLOAT SWITCH (ONE FLOAT FOR BOTH ON AND OPERATION). JUMP TERMINALS () AND (4), INSTALL WIDE ANGLE FLOAT TO TERMINALS () AND (). PAGE 4
SIMPLEX PANEL INSTALLATION THREE PHASE PROVIDE ONNECT PER NEC CODE AMP RATING S 08/0/460/575 VAC PHASE 60 HZ L L L T 75 VA 575 VAC 460 VAC 0 VAC 08 VAC FACTORY WIRED FOR 460 VAC. FOR 08, 0 OR FOR 575 VAC OPERATION CHANGE CONTROL TRANSFORMER PRIMARY AT TERMINAL BLOCK. 0 VAC A CONTROL ON- PURPLE S BROWN ON R RESET C FLASH RED WHT L FLASHING ALARM MUTE TEST SONALERT NEU H L N 4 5 6 7 8 J DRY CONTACTS FOR SEPARATE 0 VAC CONTROL POWER SUPPLY, REMOVE JUMPER (J) FROM TERMINALS (H) AND (L). CONNECT 5 AMP MAX. PROTECTED 0 VAC SUPPLY TO TERMINALS (L) AND (N). WITH THE NEUTRAL OF THE SUPPLY TO (N). FLOAT ON FLOAT ALARM FLOAT FOR USE WITH WIDE ANGLE FLOAT SWITCH (ONE FLOAT FOR BOTH ON AND OPERATION). JUMP TERMINALS () AND (4), INSTALL WIDE ANGLE FLOAT TO TERMINALS () AND (). PAGE 5
DUPLEX PANEL INSTALLATION SINGLE PHASE 5/0 VAC (FOR 5 VAC, USE TERMINALS L AND N, JUMP L AND N.) SINGLE PHASE 60 HZ AMP RATING S T.5-4.0 AMPS S L T L N GND CONTROL ON- A PURPLE S YELLOW BLUE S ORANGE R TEST R MUTE C RESET LEAD LAG ALARM FLASHING RED FLASH L N SONALERT H L N 4 5 6 7 8 9 0 J FOR SEPARATE 0 VAC CONTROL POWER SUPPLY, REMOVE JUMPER (J) FROM TERMINALS (H) AND (L). CONNECT 5 AMP MAX. PROTECTED 0 VAC SUPPLY TO TERMINALS (L) AND (N). WITH THE NEUTRAL OF THE SUPPLY TO (N). FLOAT LEAD FLOAT LAG FLOAT (OPTIONAL) ALARM FLOAT DRY CONTACTS J FACTORY WIRED FOR () FLOAT OPERATION. FOR (4) FLOAT OPERATION, REMOVE JUMPER (J) FROM TERMINALS (6) AND (8). INSTALL LAG FLOAT ON TERMINALS (5) AND (6). FOR USE WITH WIDE ANGLE FLOAT SWITCH (ONE FLOAT FOR BOTH ON AND OPERATION). JUMP TERMINALS () AND (4), INSTALL WIDE ANGLE FLOAT TO TERMINALS () AND (). PAGE 6
DUPLEX PANEL INSTALLATION THREE PHASE PROVIDE ONNECT PER NEC CODE AMP RATING.5-4.0 AMPS S S T NO. 08/0/460/575 VAC PHASE 60 HZ L L L T NO. A 75 VA 575 VAC 460 VAC 0 VAC 0 VAC 08 VAC FACTORY WIRED FOR 460 VAC. FOR 08, 0 OR FOR 575 VAC OPERATION CHANGE CONTROL TRANSFORMER PRIMARY AT TERMINAL BLOCK. CONTROL ON- PURPLE S YELLOW BLUE S ORANGE R TEST R MUTE C RESET LEAD LAG ALARM FLASHING RED FLASH L N SONALERT H L N 4 5 6 7 8 9 0 J FOR SEPARATE 0 VAC CONTROL POWER SUPPLY, REMOVE JUMPER (J) FROM TERMINALS (H) AND (L). CONNECT 5 AMP MAX. PROTECTED 0 VAC SUPPLY TO TERMINALS (L) AND (N). WITH THE NEUTRAL OF THE SUPPLY TO (N). FLOAT LEAD FLOAT LAG FLOAT (OPTIONAL) ALARM FLOAT DRY CONTACTS FACTORY WIRED FOR () FLOAT OPERATION. FOR (4) FLOAT OPERATION, REMOVE JUMPER (J) FROM TERMINALS (6) AND (8). INSTALL LAG FLOAT ON TERMINALS (5) AND (6). J FOR USE WITH WIDE ANGLE FLOAT SWITCH (ONE FLOAT FOR BOTH ON AND OPERATION). JUMP TERMINALS () AND (4), INSTALL WIDE ANGLE FLOAT TO TERMINALS () AND (). PAGE 7
Xylem ) The tissue in plants that brings water upward from the roots; ) a leading global water technology company. We re,900 people unified in a common purpose: creating innovative solutions to meet our world s water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 50 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to www.xyleminc.com Xylem Inc. 88 East Bayard Street Ext., Suite A Seneca Falls, NY 48 Phone: (866) 5-40 Fax: (888) -5877 www.centripro.com is a trademark of Xylem Inc. or one of its subsidiaries. 0 Xylem Inc. BCPSDWWP R October 0