NXM2G Installation and Operating Manual

Similar documents
MBCE-110/230FR Flame Sensor Module

MBCE-110/230UV Flame Sensor Module

MBUV-100D, MBUVS-100D MBIR-100D, MBFR-100D DIN RAIL MOUNT FLAMEWORX MODULES

MBCE-110/230FR Flame Sensor Module

FIREYE FLAME SCANNERS

FIREYE C9707A ALL FUEL SCANNER

E340 BOILER CONTROL INSTALLATION MANUAL

FIREYE YZ300 and YZ320 INTERLOCK ANNUNCIATOR For use with the Fireye BurnerLogix Control

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

ED510 DISPLAY MODULE. FOR USE WITH FIREYE FLAME-MONITOR AND MicroM BURNER MANAGEMENT CONTROLS DESCRIPTION INSTALLATION APPROVED

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Fireye FLAME SCANNERS

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

Distributed By: M&M Control Service, INC

FIREYE FLAME SCANNERS

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Model R060 Installation - Operation Manual

INSTALLATION INSTRUCTIONS

FIREYE FLAME SCANNERS

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

SAFETY INFORMATION AND WARNINGS

FLCH4R Garage and Utility Electric Heater

OPERATING INSTRUCTIONS

breeze easytm model # F100-1W

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Remote Relay Module (RRM)

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

READ AND SAVE THESE INSTRUCTIONS

MaxLite LED Vapor Tight Linear Fixture

Operations Manual. Motion Detector Module Model ZS10

Model NT20e Installation Guide

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Installation, Operation & Service Manual

SYSTEM CONTROL KIT Model: CK-41P

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

e Heater/Exhaust Fan/Light User s Guide

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

MaxLite LED Round Pendant Highbay Series

BC-R10 Series. Burner Controllers

For use with models: BP , BP , BP

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Easy installation in both new construction and retrofit

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

INSTALLATION AND OPERATION INSTRUCTIONS

Proliphix Thermostat Installation Guide. Release 2.0

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK

Bathroom Exhaust Fan/Fluorescent Light Combination

7800 SERIES RM7888A Relay Module

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Controllers. Instruction Manual WARNING

FIREYE FLAME SAFEGUARD CONTROLS DESCRIPTION

Installation and Operation Manual

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Instruction Manual WARNING

Power Pack Service Manual

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

WHE 2.24 / WHE 2.24 FF

INSTRUCTION MANUAL HS-229G

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

52 BERKSHIRE CEILING FAN

Oakton TEMP 9500 Advanced Multiparameter Controller

SC Installation, Operation & Application Guide

EEMAX HOME ADVANTAGE

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

COMBUSTION AIR SYSTEM Model: CAS-3

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50-6/16LP50-6, 16NG60-6/16LP60-6, 20NG50-6/20LP50-6, 20NG60-6/20LP60-6, 26NG50-6/26LP50-6, 26NG60-6/26LP60-6

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

MODEL SST 2 40 FREEZE PROTECTION THERMOSTAT MODEL SST FIXED SET POINT THERMOSTAT. Installation and Operation Manual

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

Operator: Save these instructions for future use!

INSTRUCTION MANUAL P Heating and 1 Cooling

Digital Non-Programmable

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

FIREYE FLAME SCANNERS

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

Transcription:

NXM2G-1001 MARCH 26, 2014 NXM2G Installation and Operating Manual (-1 UL version shown) 40VG This manual must be affixed on or adjacent to the boiler or kept with boiler operating manual or other information. NXM2G DESCRIPTION The NXM2G system is a microprocessor based boiler load optimization control system designed to provide optimum thermal efficiency of Low Temperature Hot Water (LTHW) boilers. Control theory The NXM2G measures the supply (flow) and return temperatures via digital sensors (supplied) and monitors the call for heat via the Opto-isolators from the limit string wiring connections. On first firing, the boiler will reach the normal cut out set point and turn off, On the next burner cycle, the NXM2G will check: i) for the call for heat ii) if the boiler flow and return temperatures are within the designed temperature differential settings (parameter), and iii) if the boiler is required to fire, based on control algorithms. When this occurs, the NXM2G will hold off the boiler firing (save mode) based on temperature and time, which are both adaptive. The NXM2G will also inhibit the burner from firing on stage 2, if the boiler load demand is low, thus ensuring the best efficiency for the current system demand. WARNING: The installer must be suitably qualified and trained to install NXM2G. Follow the boiler manufacturer s instructions. NXM2G interface wiring The NXM2G has 2 normally closed relays which are failsafe. These relays are wired in series to the 1st and 2nd stage operating control circuits. The relays operate according to whether the boiler is in save mode or low fire save mode. The NXM2G has a series of LEDs that give the following indications: Power 120 VAC applied Thermostat on Call for heat / 1st Stage thermostat closed Blinking: "Save" mode Steady: Boiler allowed to fire 1

Boiler firing Call for heat / Boiler allowed to fire Blinking: Burner purging Steady: Boiler allowed to fire (or fuel valve open) Stage 2 firing Call for heat / 2nd Stage thermostat closed Blinking: "Low Fire Save" mode Steady: Stage 2 firing Failsafe operation In all cases the safety integrity of the boiler operation is not compromised. Moreover, the boiler set point is always maintained. Should the NXM2G unit fail or lose electrical supply the boiler control system wiring remains as normal and the boiler will operate as if the NXM2G were not installed. The boiler s operating control is always in circuit and protected with the boiler high temperature limit. NXM2G WIRING SCHEMATIC Figure 1 shows the wiring of the NXM2G. The NXM2G has 4 separate plug connections for field wiring. FIGURE 1. NXM2G Terminal Connections FIGURE 2. fused (3.0 Amp) 2

Power Wiring It is required that the NXM2G device be powered via a Listed isolation switch. The NXM2G may be powered from the same isolated supply provided that the branch circuit protection or fuse located within the isolator (if present) is rated at 7A or less. Where the NXM2G circuit protection exceeds 7A, the supply for the NXM2G from the isolated supply shall include a supplementary fuse rated at 3A." The wiring associated with the control circuits (J2) shall be protected by an overcurrent device rated at not more than 7A. Overcurrent protection may be incorporated into the controlled devices NXM2G SPECIFICATIONS NXM2G System Model NXM2G Supply Voltage: 120V AC / 60Hz Rated Current: 50mA Relay Switching Capacity: 2A at 120V AC (resistive) Fuse Rating: 1.6A @ 120 V AC Dimensions: 6.9 (175mm) W x 7.9 (200mm) H x 2.1 (54mm) D Sensors: Plug in Digital Thermometer (2) Sensor Range: Weight: Case: Environment: Maximum Operating Temperature Limits: Minimum Operating Temperature Limits: Maximum: Humidity: 131 F to 257 F (55 C to 125 C) 3.6 pounds (1.6kg) Painted Metal NEMA 1 / IP11 Note: Casing not intended for outdoor installation. For outdoor installations the device should be enclosed in an appropriate utility box (NEMA 3 or better). 125 F (52 C) 32 F (0 C) Mounted surface temperature 104 F (40 C) 85% R.H. Maximum (Non-Condensing) The right to make changes in specification or design at any time without prior notice is hereby reserved. 3

SUITABLE NXM2G APPLICATIONS The NXM2G operates on: Low temperature hot water (LTHW) boilers fired with: on/off forced draft burners two stage high/low burners modulating burners Atmospheric boilers fired with: two stage burners modulating burners Wiring Diagrams FIGURE 3. Typical Wiring for single stage atmospheric boiler SUPPLY FUSE 3.0A max 7.0 A max 4

FIGURE 4. Typical Wiring for single stage forced draft burner 7.0 A max FIGURE 5. Typical Wiring for 2 stage High/Low force draft boiler 7.0 A max 5

INSTALLING THE NXM2G CAUTION: Electrical supply to the boiler and burner must be isolated during the installation process. Before installing the NXM2G 1. Ensure that all boiler equipment is suitable for an NXM2G installation. 2. Ensure that all boiler equipment is fully functional. Installing the NXM2G Mount the NXM2G wiring base on the boiler casing or on a suitable adjacent surface. The location should be free from excessive vibration within the specified ambient temperature rating (i.e away from hot surfaces). The NXM2G base can be mounted in any angular position CAUTION: Ensure that the mounting area for the NXM2G is free from hidden electrical cables and other obstructions. When choosing a place to locate the NXM2G, ensure that 1. The position of the NXM2G does not obstruct the boiler access panels used for maintenance 2. The NXM2G LEDs can be viewed without restriction. CAUTION: All wiring should comply with applicable electrical codes, regulations for local conditions. Use moisture / heat resistant color coded multi core cable. The NXM2G must be correctly grounded (earthed) to provide a minimal effect of AC quality problems. 6

TYPICAL NXM2G INSTALLATION PROCEDURES When installing the NXM2G, the following procedures must be followed: Remove the bottom wiring cover. Select the required conduit size and connections for the field wiring to the boiler controls and temperature sensors. Use suitable screwed fasteners such as self tapping screws. Only use the holes provided in the wiring compartment for mounting the NXM2G. For top mounting, use only mounting screws and brackets provided. WARNING: Do not use the internal PCB area to secure the NXM2G doing so will void the warranty Use conduits to run wires to connect the boiler thermostat/s or boiler control panel to the NXM2G. Conduits must be used to run the flow and return sensor wires to the NXM2G. TIP: Before installing the temperature sensors inside the conduits, mark either or both the flow or return sensor(s) with colored tape at both ends of the cable(s). This helps to ensure correct orientation when inserting the plugs into the NXM2G connectors. i.e. the supply (flow) sensor plugs into the supply (flow) connector on the NXM2G and the return sensor plugs into the return connector on the NXM2G. Use colored multi-core cable to make the various connections between the boiler and the NXM2G. Remove the plug connectors from the wiring compartment. As in Figure 1. using the cable anchor provided, use cable ties to secure cables in the wiring compartment. Connect mains L, N and E (Ground) to the connector and plug into the NXM2G as in Figure 1. The L, N and E (Ground) must be on the same electrical phase as the boiler/burner s electrical supply. 7

WARNING: Ensure that the NXM2G mains electrical supply is on the same phase as the boiler / burner s electrical supply. Locate the required boiler thermostat(s). Connect to the switched side of the thermostat contacts, as shown in Figure 1. Use the boiler/burner manufacturers wiring diagrams to determine the connections to the NXM2G as in Figure 1. Wire the connector as in Figure 1. Plug the connector into NXM2G as in Figure 1. The supply (flow) and supply return temperature sensors need to be fixed to the correct boiler pipe work connections; this should be as close to the boiler as possible. This may require the pipe work insulation to be removed. Using appropriate banding (clamp), secure the sensors to the pipe. Please note: Do not over tighten, as this may damage the sensor. Replace the pipe work insulation on completion. Plug the correct supply (flow) and return sensors into the NXM2G terminal as detailed in Figure 1. Ensure that all connections, including ground/earth connections, are secure. Replace covers with screws provided. 8

NXM2G COMMISSIONING AND FUNCTIONAL TESTS Before commissioning the NXM2G check the following: 1. The NXM2G has been correctly positioned and is securely mounted to the mounting surface 2. The connectors in the NXM2G have been correctly wired to boiler/burner. 3. The electrical supply voltage and phase are powering the NXM2G correctly. Commissioning the NXM2G on the boiler can now begin by following the steps below: 1. Power up the boiler and burner. 2. Observe LED status. (Refer to Figure 6 on following page) 3. Note: during power up all LEDs will be illuminated for a short time. 4. Confirm operation for Thermostat on and Boiler firing LEDs and check for Boiler firing mode. This will allow the burner/boiler to start without interruption (i.e. not in save mode) when the NXM2G is powered for the first time. (see Figure 6 ). 5. Operate the boiler thermostat (boiler firing) to stop the boiler/burner firing. Then reset the thermostat to call for heat and check that the NXM2G initiates the save mode with the Thermostat On LED flashing. 6. Operate boiler thermostat (stage 2 firing) if applicable and check second stage first firing mode (see Figure 6 ) 7. Operate boiler thermostat (stage 2 firing) to reduce boiler firing to 1st boiler firing. Then reset the thermostat to call for heat and check that the NXM2G initiates the save mode Stage 2 firing LED now flashing. 8. Isolate the boiler/burner and repeat the above procedures. 9. In the event that the NXM2G does not operate as in Figure 6, isolate boiler/burner and check all wiring connections, and repeat steps 1 to 7. 9

NXM2G IN OPERATION FIGURE 6. NXM2G Operation Status (LED's) 10

FAULT FINDING FIGURE 7.1 Use the relevant flowcharts to troubleshoot non-working NXM2Gs. Typical faults with flowchart guides to resolving the problems are: 1. Electrical Supply Fault NXM2G Power (Red) LED off follow flowchart in Figure 7.1 2. NXM2G Power supply correct (red LED on) however, boiler is not firing during first firing follow flowchart in Figure 7.2 3. Boiler/Burner fires during first firing only and will not re fire thereafter follow flowchart in Figure 7.3 4. Boiler/Burner fires in normal way, without NXM2G operating in Save mode after first firing follow flowchart in Figure 7.4 5. NXM2G Operates Boiler/Burner but Thermostat on and Boiler firing LED s remain on, when the boiler is not firing follow flowchart in Figure 7.5 Electrical Supply Fault NXM2G Power (Red) LED off 11

FIGURE 7.2 NXM2G Power supply correct (red LED on), however boiler will not fire during First Firing FIGURE 7.3 Boiler/Burner fires during First firing only and will not re-fire thereafter 12

FIGURE 7.4 Boiler/Burner fires in normal way, without NXM2G operating in Save mode after first firing FIGURE 7.5 NXM2G Operates Boiler/Burner but Thermostat on and Boiler firing LED s remain on, when the boiler is not firing 13

FIGURE 7.6 NXM2G Interlock Schematic NXM2G interlock schematic, showing the correct positioning of the NXM2G in the boiler control circuit. NOTICE WARRANTIES When Fireye products are combined with equipment manufactured by others and/or integrated into systems designed or manufactured by others, the Fireye warranty, as stated it its General Terms and Conditions of Sale, pertains only to the Fireye products and not to any other equipment or to the combined system or its overall performance. FIREYE guarantees for one year from the date of installation or 18 months from date of manufacture of its products to replace, or, at its option, to repair any product or part thereof (except lamps, electronic tubes and photocells) which is found defective in material or workmanship or which otherwise fails to conform to the description of the product on the face of its sales order. THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES AND FIREYE MAKES NO WARRANTY OF MERCHANTABILITY OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED. Except as specifically stated in these general terms and conditions of sale, remedies with respect to any product or part number manufactured or sold by Fireye shall be limited exclusively to the right to replacement or repair as above provided. In no event shall Fireye be liable for consequential or special damages of any nature that may arise in connection with such product or part. FIREYE NXM2G-1001 3 Manchester Road MARCH 26, 2014 Derry, New Hampshire 03038 USA supersedes March 18, 2013 www.fireye.com 14