Installation Instructions. Tersen. Ratio Canopy 1.5

Similar documents
DHL-LP-LED Low Profile LED Linear High/Low Bay

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

Cree XLamp CM Family LEDs

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

Damp Locations Wall & Ceiling Mount BEFORE YOU BEGIN

MLLG-DE-LED-CHAN Installation Guide IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

GLED INSTALLATION INSTRUCTIONS

SLOT PSW LED IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions Lithonia Lighting Clean Room Troffer. Grid & Sheet Rock Installation, Maintenance

AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions Labor and Delivery Exam Light Set

INSTALLATION INSTRUCTIONS WARNINGS AND INSTRUCTIONS FOR LUMINAIRES

LED IMPORTANT SAFETY INSTRUCTIONS

Fillmore Small Pendant Assembly and Installation Instructions

GLED INSTALLATION INSTRUCTIONS

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

MaxLite LED Round Pendant Highbay Series

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

INSTALLATION INSTRUCTIONS

MaxLite LED High Bay Fixtures

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

MaxLite LED MICRO-T PANEL

Please read and save these instructions. Should you have any questions or difficulty installing your fan, call us first!

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

Decorative Low Profile Integrated Kit

installation and operation manual for Hunter Ceiling Fans

WAILEA OWNER S MANUAL

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

Owner s Guide and Installation Manual

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Table of Contents. What to Expect with. Mounting Options. Tools Needed

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

Owner s Guide and Installation Manual

WARNING Risk of fire and electrical shock. DISCONNECT POWER AT ELECTRICAL PANEL before installing or servicing this product.

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Downrod. Canopy.

Table of Contents. What to Expect with Your Installation. Tools Needed. Mounting Options. Ceiling Bracket. Wiring.

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Owner s Guide and Installation Manual

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

LED. 60 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

Owner s Guide and Installation Manual

Installation and Operation Manual For Hunter Ceiling Fans

Installation guide. Philips EvoKit LED 2x4 and 2x2

Essex 42 Ceiling Fan TOOLS AND MATERIALS REQUIRED Mounting options : Hugger & Drop mount

MaxLite LED Vapor Tight Linear Fixture

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Ceiling Fan Ow n e r s Manual

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

Owner s Guide and Installation Manual

Installation Guide. For Models: E-PD52ABZ5C4 E-PD52BP5C4 E-PD52WW5C4 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Owner s Guide and Installation Manual

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades.

CEILING FAN OWNER S MANUAL

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

Cold Deck Canopy and Shelf Lights and Retrofit Kit

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

Installation Manual. Models 99168, 99169, 99170

DP25 & DR25 RECESSED T-BAR INSTALLATION INSTRUCTIONS

Table of Contents. 1 M /10/14 Casablanca Fan Company. What to Expect with Tools Needed.

Table of Contents What to Expect with. Mounting Options. Tools Needed. Downrod. Blades

CEILING FAN OWNER'S MANUAL

Cold Door 2 LED Retrofit Kit Lighting System

Hanson LED C e i l i n g F a n

Installation Guide. For Models: E-DCF52BNK5C3 E-DCF52FBZ5C3 E-DCF52MWW5C3 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

FerronTM. Instruction Manual A Kichler Decor ceiling fan

Owner s Guide and Installation Manual

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

Type 2 Models. Owner s Guide and Installation Manual. English Español

Table of Contents. 1 M /08/ Hunter Fan Company. What to Expect with. Preparation. Tools Needed.

KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

PARISIAN ARCHITECTURAL BRASSERIE PENDANT 9

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL

Austin 42 Ceiling Fan

CEILING FAN OWNER S MANUAL

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

Transcription:

Installation Instructions Tersen TM Ratio Canopy 1.5

Ratio Canopy 1.5 tlroc15 Installation Instructions NOTE: This lighting fixture is designed for outdoor lighting services, and should not be used in areas of limited ventilation or in high ambient temperature enclosures. It must be stored in a dry location prior to installation. Do not expose lighting fixture to rain, dust or other environmental conditions prior to installation. Construction is suitable for down lighting only. Do not place the fixture onto the ground with the LED/optical side facing down during the installation process. Best results will be obtained if installed and maintained according to the following recommendations. INSTALLATION: Your lighting fixture has been shipped with one of several types of mounting options. Please follow the installation instructions specific to the catalog part that you ordered. If the maintenance plan for your specific mounting application calls for hosing down the fixture, all supply wires used must include wet rated wire insulation and splice components. STOP PRIOR TO INSTALLATION ASSURE THAT ALL POWER IS OFF CEILING MOUNT: TOOLS REQUIRED: Flat blade screw driver, Phillips head screw driver, electrical wiring tools. 1. Assemble top quick mount bracket to j-box [not supplied] located in ceiling using appropriate hardware [not supplied] for the junction interface [j-box must be secured to ceiling structure and must be able to support a minimum of 25 lbs.]. 2. Lift fixture assembly to the top quick mount bracket that has been attached to the ceiling/ j-box and connect the safety cable clip to the hole provided in the top quick mount box. 3. Connect supply wires to appropriate fixture leads with wire nuts: a. Supply side line voltage wire to black fixture lead. b. Supply side neutral wire to white fixture lead. c. Supply side ground wire to green fixture lead. 4. Push the wire splices back into j-box while lifting fixture to rotate the bottom quick mount bracket into the top quick mount bracket until positive stop and audible click. 5. The fixture is now ready to be energized.

PENDANT MOUNT (Swivel junction box cover): TOOLS REQUIRED: Pipe wrench, 9/64 hex bit, electrical wiring tools. 1. Feed wires exiting fixture through ¾ stem and the bell-shaped swivel pivot of the Tersen SLVxx Accessory. 2. Apply pipe sealant per sealant manufacturer s instruction to threaded stem ends. Attach the bellshaped swivel pivot of the Tersen SLVxx Accessory to produce a water tight seal on one stem end and other end to fixture to produce a water-tight seal. Tighten to 20 in-lbs. 3. Remove stem locking screw and apply sealant per sealant manufacturer s instruction to ensure a water-tight connection. Reinsert set screw and tighten to 10 in-lbs. 4. Secure the swivel junction box cover to the junction box appropriately mounted on ceiling surface. 5. Raise the fixture and hang the swivel pivot in the open swivel cover so the entire fixture assembly nests in place. 6. Align the T-shaped locking tab on the swivel cover with the slot in the swivel pivot. Using a screwdriver, push the T tab over the top of the slot on the swivel pivot to prevent the swivel pivot from rotating. NOTE: The top of the T tab should rest in the bottom of the slot in the swivel pivot. This will allow the fixture assembly to swing freely while still maintaining a solid connection with the pipe. 7. Connect wires to appropriate fixture leads using UL approved splicing/wire nuts: a. Supply side ground wire to green fixture lead. b. Supply side neutral wire to white fixture lead. c. Supply side line voltage wire to black fixture lead. 8. Set wiring into junction box without compromising the connections. 9. Rotate junction box cover closed and secure with screw. 10. The fixture is now ready to be energized. Tersen Headquarters 3825 Columbus Road Granville, OH 43023 Phone: 1-800-410-8899 www.tersenlighting.com

Ratio Canopy 1.5 tlroc15 Installation Instructions PENDANT MOUNT (Fixed junction box cover): TOOLS REQUIRED: Pipe wrench, 9/64 hex bit, electrical wiring tools. 1. Feed wires exiting fixture through ¾ stem and bring that end close to the fixture. 2. Apply appropriate sealant per sealant manufacturer s instruction to pendant threads and thread pendant into fixture to ensure a water-tight seal. Tighten to 20 in-lbs. 3. Remove stem locking screw and apply sealant per sealant manufacturer s instruction to ensure a water-tight connection. Reinsert set screw and tighten to 10 in-lbs.thread the 1st conduit nut onto other end of 3/4 pipe nipple and run to the end of thread. 4. Position pipe nipple through the circular opening of a j-box cover plate. 5. Secure the pipe nipple to the j-box cover plate using the 2nd conduit nut. Tighten both nuts securely against the plate oriented with respect to fixture. 6. Tighten the set screw in the fixture to secure pipe nipple against rotation. 7. Connect wires to appropriate fixture leads using UL approved splicing/wire nuts: a. Supply side ground wire to green fixture lead. b. Supply side neutral wire to white fixture lead. c. Supply side line voltage wire to black fixture lead. 8. The fixture is now ready to be energized.

BI-LEVEL SWITCHING [IF EQUIPPED] For Bi-level switching, the input leads to the fixture will be independently labeled to indicate dimming preferences as appropriate [as defined by the order requirements]. Two [2] Separate supply lines of line voltage, neutral and ground must be provided to the fixture to enable the bilevel switching functionality of the fixture. MAINTENANCE A regular maintenance schedule should be followed to retain optimal light output and thermal performance. Optical lens cleaning should be performed with a clean dry cloth to remove any dust or other contaminants. Additional cleaning can be performed with non-abrasive acrylic cleansing solution. The following chemicals tested as harmful to the LED s and should not be used on or around the fixture. Consult Tersen Lighting before use of any chemical agent. Chemicals that might outgas aromatic hydrocarbons (e.g., toluene, benzene, xylene) Methyl acetate or ethyl acetate (i.e., nail polish remover) Cyanoacrylates (i.e., Superglue ) Glycol ethers (including Radio Shack Precision Electronics Cleaner - dipropylene glycol monomethyl ether) Formaldehyde or butadiene (including Ashland PLIOBOND adhesive) Loctite Sumo Glue Gorilla Glue Clorox bleach Clorox Clean-Up Cleaner spray Loctite 384 adhesive Loctite 7387 activator Tersen Headquarters 3825 Columbus Road Granville, OH 43023 Phone: 1-800-410-8899 www.tersenlighting.com

WARNING RISK OF ELECTRIC SHOCK 4 Disconnect or turn off power before installation or servicing. 4 Verify that supply voltage is correct by comparing it with the luminaire label information. 4 Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements. 4 All wiring connections should be capped with UL approved recognized wire connectors. CAUTION RISK OF INJURY 4 Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance. 4 Avoid direct eye exposure to the light source while it is on. WARNING RISK OF BURN 4 Allow lamp/fixture to cool before handling. Do not touch hot lens, lamp, guard, or enclosure. 4 Do not exceed maximum wattage marked on luminaire label. 4 Follow all lamp manufacturer s warnings, recommendations and restrictions on lamp operation including but not limited to: ballast type, burning position, replacement, and recycling. 4 Use only lamps that comply with ANSI standards. CAUTION RISK OF FIRE 4 Keep combustible and other materials that can burn away from lamp/lens. 4 Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying. PART NO. TY00001 INSTALLATION INSTRUCTIONS Rev. 10/15/12 Tersen Headquarters 3825 Columbus Road Granville, OH 43023 Phone: 1-800-410-8899 www.tersenlighting.com