Cold from Heat Product Catalogue 2010 Adsorption Chillers Re-coolers Pump Stations Accessories
Complete System of Thermal Cooling Introduction The complete system for ACS operation is comprised of three hydraulic circuits: The driving circuit, HT, which delivers heat at a high temperature level (starting at 55 C) for desorption (e.g. solar heat, heat from a combined heat and power plant, district heat, industrial waste heat, etc.) The re-cooling circuit, MT, which removes the accumulated heat at a medium or surrounding temperature level (e.g. dry re-cooler with water spraying system (RCS), swimming pool heater, geothermal probe, wet cooling tower, well, lake heat exchanger, etc.) The cold water circuit, LT, for distribution and usage of the generated cold (e.g. cooling ceilings, wall/floor cooling, fan coils, concrete core activation, etc.) 1 2 6 5 3 4 (1) Driving source (2) Storage buffer (3) Pump system (4) Adsorption chiller (5) Re-cooler (6) Cold distribution system Example of solar cooling
ACS 08 Adsorption chiller with thermal heat pump mode for heating support including controls, tested and ready for connection Nominal cooling capacity 8 kw Thermal COP 0.6 Cooling capacity Heating capacity Power consumption Dimensions (WxLxH) Empty weight 5-11 kw 10-25 kw 7 W 79x106x94 cm 265 kg Front and rear view; illustrations may differ Basic module ACS 08 9,990 Surcharge for extras + VBus adapter Mandatory for the signal transfer between ACS 08/RCS 08 + External set point setting For the external cold water temperature target (T_SOLL) + Outdoor For outdoor installation in frost-free regions + Terminal box on the left Alternatively, the terminal box may be connected on the left side + 380 + 127 All prices given per unit. VAT, shipping and handling not included.
ACS 15 Adsorption cooling system with thermal heat pump mode for heating support including controls, tested and ready for connection Nominal cooling capacity 15 kw Thermal COP 0.6 Cooling capacity Heating capacity 10-23 kw 20-50 kw Power consumption 14 W Dimensions (WxLxH) 79x134x139 cm Empty weight 530 kg Front and rear view; illustrations may differ Basic module ACS 15 17,990 Surcharge for extras + VBus adapter Mandatory for the signal transfer between ACS 15/RCS 15 + External set point setting For the external cold water temperature target (T_SOLL) + Outdoor For outdoor installation in frost-free regions + Terminal box on the left Alternatively, the terminal box may be connected on the left side + 380 + 127
Assembly Group PCS 08 Pump Station For the direct connection of an ACS 08 to cold distribution, recooler, and HT storage for easy and safe installation! Comprised of ready-to-connect and partially insulated hydraulic circuits with a safety group, shut-off valves, flush and drain valves, high efficiency pumps, and diaphragm-type expansion tank(s) (DET) The LT pump of the standard configuration is designed for a pressure loss of 360 mbar at a nominal volume flow of 2,000 l/h. Other pump configurations for higher pressure losses are available at a surcharge. Available in different configurations. Pump Station Example of PCS 08-W; illustrations may differ PCS 08-W Optimized for the ACS 08/RCS 08 subsystem in combination with pure water PCS 08-GHT Optimized for the ACS 08/RCS 08 subsystem in combination with water-glycol-mix (34%) PCS 08-GMT Optimized for the ACS 08/RCS 08 subsystem in combination with water-glycol-mix (34%) Suitable for free cooling and in combination with heat pump operation PCS 08-NKT Optimized for the use of a wet cooling tower in combination with pure water Preliminary values PCS 08-W PCS 08-GHT PCS 08-GMT PCS 08-NKT Operation fluid Water Water-Glycol Water-Glycol Water Plate heat exchanger - HT circuit MT circuit MT circuit Hydraulic circuits 3 3+1 3+1 3+1 High efficiency pumps 3 4 4 3 DET HT circuit (internal) - 8 l - - DET MT circuit (internal) 18 l 18 l 8 l 8 l DET MT circuit (external) - - 18 l - Power consumption 439 W 509 W 579 W 269 W Dimensions (WxLxH) 110x68x169 cm 133x68x169 cm 133x68x169 cm 103x68x169 cm Empty weight ca. 190 kg ca. 200 kg ca. 220 kg ca. 210 kg Price 4,290 5,556 6,442 5,176
Assembly Group PCS 15 Pump Sation For the direct connection of an ACS 15 to cold distribution, recooler, and HT storage for easy and safe installation! Comprised of ready-to-connect and partially insulated hydraulic circuits with a safety group, shut-off valves, flush and drain valves, high efficiency pumps, and diaphragm-type expansion tank(s) (DET) The LT pump of the standard configuration is designed for a pressure loss of 590 mbar at a nominal volume flow of 4,000 l/h. Other pump configurations for higher pressure losses are available at a surcharge. Available in different configurations. Pump Station Example of PCS 08-W; illustrations may differ PCS 15-W Optimized for the ACS 15/RCS 15 subsystem in combination with pure water PCS 15-GHT Optimized for the ACS 15/RCS 15 subsystem in combination with water-glycol-mix (34%) PCS 15-GMT Optimized for the ACS 15/RCS 15 subsystem in combination with water-glycol-mix (34%) Suitable for free cooling and in combination with heat pump operation PCS 15-NKT Optimized for the use of a wet cooling tower in combination with pure water Preliminary values PCS 15-W PCS 15-GHT PCS 15-GMT PCS 15-NKT Operation fluid Water Water-Glycol Water-Glycol Water Plate heat exchanger - HT circuit MT circuit MT circuit Hydraulic circuits 3 3+1 3+1 3+1 High efficiency pumps 3 4 4 3 DET HT circuit (internal) - 8 l - - DET MT circuit (internal) 18 l 18 l 8 l 8 l DET MT circuit (external) - - 18 l - Power consumption 900 W 1040 W 1070 W 760 W Dimensions (WxLxH) 110x68x169 cm 133x68x169 cm 133x68x169 cm 103x68x169 cm Empty weight ca. 240 kg ca. 250 kg ca. 270 kg ca. 260 kg Price 6,948 8,087 10,871 8,467
RCS Dry re-cooler with fresh water sprinkler system and EC fans Optimized for use with ACS, only in combination with VBus Adapter Including completely assembled water sprinkler system for the temporary moisturization of the air flow, pressure-relief valve, magnetic valve, and drain nozzle for the sprinkler system Example of RCS 08; illustrations may differ Re-cooler Surcharge for extras Only available for RCS 08 and RCS 15 + Thermostatic pump activation For frost protection in regions with temperatures rarely dropping below 0 C, for utilizing the power advantages of water operation + Wall mount For wall-mounting of the re-cooler + VBus adapter Mandatory for the signal transfer between ACS 08/RCS 08 + 633 + 480 RCS 08 RCS 15 RCS 30 RCS 45 Power 21 kw 42 kw 85 kw 140 kw EC fans 2 3 3 6 Water consumption sprinkler max. 4m³/a max. 6m³/a - - Power consumption 0.65 kw 1.3 kw 2.52 kw 2.82 kw Dimensions (WxLxH) 200x115x95 cm 413x115x95 cm 610x154x146 cm 755x229x146 cm Empty weight ca. 188 kg ca. 330 kg ca. 901 kg ca. 1,414 kg Price 3,690 5,690 14,490 23,490
DAS Data Acquisition System Enables the visualization of the units' conditions, yield control, easy error diagnostics, simple configuration via integrated web interface for standard internet browsers, export function for further data processing in spreadsheet applications, and direct connection to a PC or router for remote access Comprised of two data loggers, two G1 type heat meters, and sensors for measuring temperature and volume flow in the HT and LT circuit flows as well as temperature and pressure in the HT and LT returns Pre-calibrated, ready assembled and wired on a base plate (1) for wall mounting (2) and connection to the ACS (3) 1 Technical data monitoring (1) Dimensions (WxH) Weight 30 x 50 cm 2.1 kg 2 3 Data acquisition system 2,198
Price list Product Order N Unit price Adsorption Chiller ACS Incl. controller, operational check carried out, evacuated, and ready for connection ACS 08 ACS 08 9.990 ACS 15 ACS 15 17.990 Charge for additional options V-bus adapter R 253 Interface for external set points EWS 253 Outdoor OUT 380 Terminal box for left hand side LK 127 Computer data logging system DES 2.198 Re-cooler RCS Incl. water spraying system, excl. control unit (V-bus) Re-cooler RCS 08 for ACS 08 RCS 08 3.690 Re-cooler RCS 15 for ACS 15 RCS 15 5.690 Re-cooler RCS 30 for 2 ACS 15 RCS 30 14.490 Re-cooler RCS 45 for 3 ACS 15 RCS 45 23.490 Charge for additional options Only available for RCS 08 and RCS 15 Thermostatic pump activation TP 633 Wall bracket* WK 480 *after clarification of constructional conditions Hydraulic station PCS 08 for ACS 08 ready for connection and isolated pump station for connecting ACS 08 to hot water buffer, re-cooling and chilled water distribution system Water operation and RCS 08 PCS 08-W 4.290 Operation with water/glycol-mixture and RCS 08 Plate heat exchanger HT PCS 08-GHT 5.556 Operation with water/glycol-mixture and RCS 08 Plate heat exchanger MT PCS 08-GMT 6.442 Water operation and wet cooling tower PCS 08-NKT 5.176 Hydraulic station PCS 15 for ACS 15 ready for connection and isolated pump station for connecting ACS 15 to hot water buffer, re-cooling and chilled water distribution system Water operation and RCS 15 PCS 15-W 6.948 Operation with water/glycol-mixture and RCS 15 Plate heat exchanger HT PCS 15-GHT 8.087 Operation with water/glycol-mixture and RCS 15 Plate heat exchanger MT PCS 15-GMT 10.871 Water operation and wet cooling tower PCS 15-NKT 8.467 Services On-site commissioning IBN ACS 08 ACS 15 including travel expenses Germany, Austria, Switzerland 1.000 1.250 Italy, Netherlands, France, England 2.000 2.250 Spain, Greece, Malta, Turkey 2.500 2.750 Portugal 3.000 3.250 Maintenance (per hour), plus travel expenses WG 65 System design (per hour) SP 80 Prices are ex works, Incoterms 2000, unpacked, uninsured, duty unpaid, plus VAT