INDUSTRY LEADING FEATURES / BENEFITS TABLE OF CONTENTS. DLFSDA and DLFLDA Ducted Style Ductless System Sizes 09 to 58

Similar documents
Product Data. 40MBDQ Ducted Slim Ductless System Sizes 09 to 58 INDUSTRY LEADING FEATURES / BENEFITS TABLE OF CONTENTS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

DLFSCA and DLFLCA Cassette Ductless System Sizes 9 to 48 INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MA*R Outdoor Unit Single Zone Ductless System Sizes 09 to 36

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MAQ High Wall Ductless System Sizes 09 to 36

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MHRB Outdoor Unit Single Zone Ductless System Sizes 09 to 24

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*C / 38MAQ Cassette Ductless Split System Sizes 09 to 18

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MVC / 38MVC 40MVQ / 38MVQ High---Wall Duct Free Split System Sizes 009 to 024

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*F / 38MAQ Floor Console Ductless Split System Sizes 09 to 12

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*F / 38MAQ Floor Console Ductless Split System Sizes 09 to 12

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*C / 38MAQ Cassette Ductless Split System Sizes 09 to 18

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MPRA Outdoor Unit Single Zone Ductless System Sizes 09 to 12

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38GJQ / 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Multi---Zone Ductless Split System Size 18K, 24K, 30K, 36K, 42K, 48K and 56k

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GRQ / 38GRQ High- Wall Ductless Split System Sizes 09 to 18

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MAQ / 38MAQ High- Wall Ductless Split System Sizes 09 to 30

PERFORMANCE DATA Model Numbers Cooling High Heating 47 F Low Heating 17 F

Product Data. DLCERA Outdoor Unit Single Zone Ductless System Sizes 09 to 24 INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GRQ / 38GRQ High Wall Ductless Split System Sizes 09 to 18

Product Data. 38GXM / 40GXM Multi---Split High---Wall Duct Free Split System 38GXM --- Size 18k, 24k, and 30k 40GXM --- Size 9k, 12k, and 18k

Product Data INDUSTRY LEADING FEATURES / BENEFITS. DHCMA / DACMA DHQMA / DAQMA High Wall Ductless System Sizes 09 to 22

Product Data. 38GVM / 40GVM Multi---Split High---Wall Ductless Split System 38GVM --- Size 18k, 24k, 30k, 36k and 42k 40GVM --- Size 9k, 12k, and 18k

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MBQ Outdoor Unit Single Zone Ductless System Sizes 36 to 48

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*D / 38MAQ / 38MBQ Ducted Split System Sizes 09 to 48

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*D / 38MAQ / 38MBQ Ducted Split System Sizes 09 to 48

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GXC / 38GXC 40GXQ / 38GXQ Inverter---Driven High Wall Duct---Free Split System Sizes 009 to 024

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GVC / 38GVC 40GVQ / 38GVQ High---Wall Ductless Split Systems Size 009K K

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38MG / 40MA / 40MB Multi- Zone Ductless Split System Size 18k, 27k, 36k and 48k INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data. High --- Wall Duct --- Free Split systems INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38MGQ Multi-Zone Ductless System Sizes 18, 27, 36 and 48 INDUSTRY LEADING FEATURES / BENEFITS

Installation Instructions

Service Manual CAUTION ! WARNING SAFETY CONSIDERATIONS INTRODUCTION. 40MFC / 38MFC 40MFQ / 38MFQ High Wall Ductless System Sizes 09 to 22

Owner s Manual TABLE OF CONTENTS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MKCB / 24AHA4 / 124ANS 40MKQB / 25HHA4 / 224ANS High---Wall Ductless Split System Sizes 18 to 32

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Installation Instructions

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

R4H4. Product Specifications

Installation Instructions

Installation Instructions

Service Manual CAUTION ! WARNING SAFETY CONSIDERATIONS INTRODUCTION 619PB / 538PR HIGH-WALL DUCTLESS SPLIT SYSTEM SIZES 09 TO 30

Owner s Manual TABLE OF CONTENTS

Installation Instructions

Installation Instructions

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Owner s Manual TABLE OF CONTENTS

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price

Residential and Light Commercial Ductless Systems Catalog

R4H4. Product Specifications

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

PAJ3. Product Specifications

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Product Data. S UTEC ignition control and fan timer board provide. S S Cabinet features an insulated enclosure for the burner

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

N4H4. Product Specifications

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Hi - Wall Split Systems 12K - 18K - 24K

5) Do not start or stop the unit by inserting or pulling out the power plug.

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

TECHNICAL SPECIFICATIONS

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Installation Instructions

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

WCH5**4. Product Specifications

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MKCC / 24AHA4 / 124ANS 40MKQC / 25HHA4 / 224ANS Cassette Ductless Split System Sizes 18 to 34

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

CAUTION DLFEHA. SERVICE MANUAL High Wall Ductless System Sizes 09 to 24

Owner's Manual TABLE OF CONTENTS

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

WJH4 Product Specifications

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Product Specifications. Vertical Floor Consoles By First Co.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

C13-Series Engineering Guide

SUPER INVERTER H6 Service manual

Product Data. 367AAN Low --- Boy Oil Furnace Input Capacities: 70,000 thru 154,000 BTUH Series E 367AAN FEATURES/BENEFITS

Transcription:

DLFDA and DLFLDA Ducted tyle Ductless ystem izes 9 to 5 INDUTRY LEADING FEATURE / BENEFIT NOTE: Images for illustration purposes only. Actual models may be slightly different. TABLE OF TENT PAGE MODEL NUMBER NOMENLATURE... TANDARD FEATURE AND AEORIE... DIMENI... 5 LEARANE... 7 PEIFIATI... APPLIATI DATA... 9 WIRING... 9 WIRING DIAGRAM... 2 GUIDE PEIFIATI... A PERFET BALANE BETWEEN BUDGET LIMIT, ENERGY AVING AND OMFORT. The ducted style ductless systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires. The fan coil is mounted in the ceiling. This selection of fan coils permits creative solutions to design problems such as: Add ons to current space (an office or family room addition) pecial space requirements When changes in the load cannot be handled by the existing system. Historical renovations or any application where preserving the look of the original structure is essential. These compact indoor fan coil units take up very little space above the ceiling. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels. pecifications subject to change without notice.

LOW OUND LEVEL When noise is a concern, the ductless systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork. EURE OPERATI If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since outdoor units can be installed close to an outside wall, coils are protected from vandals and severe weather. FAT INTALLATI This compact ductless system is simple to install. A mounting bracket and duct work is needed for the indoor units, and only wire and piping need run between the indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the ducted style ductless systems the equipment of choice, especially in retrofit situations. IMPLE ERVIING AND MAINTENANE Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. oils can be cleaned quickly from the inside using a pressure hose and detergent. On all indoor units, service and maintenance expense is reduced due to easy accessible service panels. In addition, these ducted systems have extensive self diagnostics to assist in troubleshooting. BUILT IN RELIABILITY Ducted style ductless system indoor and outdoor units are designed to provide years of trouble free operation. The ducted indoor units include protection against freeze up and high evaporator temperatures on heat pumps. The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over current protection and the high temperature protection. INDIVIDUAL ROOM OMFORT Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year round comfort can be provided with heat pumps. EOMIAL OPERATI The ducted style ductless system design allows individual or multi room heating or cooling when required. There is no need to run large supply air fans or chilled water pumps to handle a few spaces with unique load patterns. EAY TO UE TROL The ducted units have microprocessor based controls to provide the ultimate in comfort and efficiency. The user friendly wired and wireless remote control provides the interface between user and the unit. BUILT IN DENATE LIFT PUMP Factory installed condensate lift pump on the ducted fan coil provides installation flexibility. OPTIAL WI TROLLER Timer Function TANDARD WI TROLLER 7 Day Programmable AGENY LITING All systems are listed with AHRI (Air onditioning, Heating & Refrigeration Institute), and ETL. 2 pecifications subject to change without notice. 2

MODEL NUMBER NOMENLATURE INDOOR UNIT DLF = FAN OIL UNIT DLF D A H 9 X A K VOLTAGE K = 2/2--6 &L = MODEL A = VARIATI INDOOR FAN OIL TYPE D = DUTED MAJOR ERIE INDOOR FAN OIL TYPE H = HEAT PUMP X = NOT UED NOMINAL APAITY 9 - / T 2 - T 2-2 T - 2.5 T 6 - T - T 5-5 T Use of the AHRI ertified TM Mark indicates a manufacturer s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. pecifications subject to change without notice. 2

TANDARD FEATURE AND AEORIE Ease Of Installation Mounting Brackets Horizontal Installation Vertical Installation (izes 9-) Low Voltage ontrols omfort Features Rear or Bottom Return Microprocessor ontrols Wired Remote ontrol (7 Day Programmable KAN5AAA Wi-Fi Remote ontrol Wireless Remote ontrol Auto Restart Function old Blow Protection On Heat Pumps Freeze Protection Mode On Heat Pumps Turbo Mode Auto hangeover On Heat Pumps Follow Me (ense Temperature at remote) Energy aving Features Outside Air Intake leep Mode top/tart Timer 6 F Heating Mode (Heating etback) afety And Reliability Indoor oil Freeze Protection Indoor oil High Temp Protection in Heating Mode Aluminum Golden Hydrophilic pre-coated fins Ease Of ervice And Maintenance leanable Filters Diagnostics Liquid Line Pressure Taps Application Flexibility Built-in ondensate Lift Pump Legend tandard A Accessory AEORIE ORDERING NO. DERIPTI FOR MODEL KANAAA Optional Wired Remote ontrol All izes with Timer Function KAIFAAA Wi-Fi Kit All izes pecifications subject to change without notice. 2

DIMENI OUTLINE DIMENI AIR OUTLET OPENING IZE AIR RETURN OPENING IZE HANGER BRAKER REFRIGERANT PIPE LOATI ize Unit A B D E F G H I J K L M H H2 W W2 In. 27.6 7.9 9.9 7.7 5. 2..2 6 2.6 7. 2 29.2.2. 5.5.. 9 mm 7 2 56 5 7 57 52 599 6 5 7 6. In. 27.6 7.9 9.9 7.7 5. 2..2 6 2.6 7. 2 29.2.2. 5.5.. 2 mm 7 2 56 5 7 57 52 599 6 5 7 6. In..65.27 26.5 2.62 5.57..97 5.5.79 7..57 6.22 2.7 5..6. 5 mm 2 67 6 76 5 6 72 9 92 5 7 2 2.5 In.. 9..7 27.56 5.5 6.6.97 6.9 9..9.2. 2.5.5 5.9 5.2 6. 7 2 mm 29 77 7 926 5 75 2 5 59 5 55 9. In. 5.5 9..7 27.56 5.5 6.69.97 6.9 9.65.9.2 55.2 2.5.5 5.9 5.2 6. 6 6 mm 6 29 77 7 6 5 75 262 5 59 5 55. In. 7.2...5...97.9.5.2.2.2 27..5 5.9 7.2.27 2 mm 2 7 2 5 227 5 2 697 5 5 2 5. In. 55.2 7.2.7..7 6.. 5.6 6.5.2.57 56.57 27.56.5.75 5.67 5.67 6 5 mm 5 77 6 9 2 5 2 2 7 7 27 27 7 OPERATING WEIGHT lb (kg) Air filter Air inlet from rear side Outside air intake -install hanger Electric control box.9in (25mm) Drain pipe Gas connection Liquid connection Test mouth & Test cover.9in (25mm) Drain connecting pipe (for lift pump) Air filter Air inlet from bottom side Fig. - Indoor Unit izes 9K K pecifications subject to change without notice. 2 5

DIMENI (T) Fig. 2 - Indoor Unit izes 5K 6 pecifications subject to change without notice. 2

>.in(c m) (When no ceiling) LEARANE Left side >in(cm) Maintenance space trong and durable ceiling Indoor unit >.in(cm) Right side Fig. - Installation learances >.in(2cm) >.in(2cm) ervice access Floor eiling >.in(cm) >.2in(25cm) MAINTENANE LEARANE A Unit ervice access OIL NETI AREA DENATE DRAIN PIPING AREA DENATE PUMP ERVIE LEARANE ENOR ERVIE LEARANE > in( cm ) B ervice access >.in cm PB BOARD ERVIE LEARANE FILTER ERVIE LEARANE Fig. - Maintenance learances apacity (Kbtu) A B 9K 29.2in.(7.cm).in.(cm) 2K 29.2in.(7.cm).in.(cm) K 6.22in.(92cm).in.(cm) 2K.in.(cm).in.(cm) 6K 55.2in.(cm).in.(cm) K.2in.(2cm) 5.75in.(cm) 5K 55.2in (cm) N/A pecifications subject to change without notice. 2 7

PEIFIATI ystem Electrical ontrols Operating Range Piping Indoor oil Indoor Heat Pump ize 9 2 2 6 5 Indoor Model DLFDAH9XAK DLFDAH2XAK DLFDAHXAK DLFDAH2XAK DLFLDAH6XAK DLFLDAHXAK DLFLDAH5XAK Voltage, Phase, ycle V/Ph/Hz 2/2--6 2/2--6 2/2--6 2/2--6 2/2--6 2/2--6 2/2--6 Power upply Indoor unit powered from outdoor unit MA A....2.2 2.5.2.65 Wireless Remote ontroller ( F/ onvertible) tandard tandard tandard tandard tandard tandard tandard Wired Remote ontroller ( F/ onvertible) tandard tandard tandard tandard tandard tandard tandard ooling Indoor DB Min -Max F ( ) 62~9 (7~2) 62~9 (7~2) 62~9 (7~2) 62~9 (7~2) 6~9 (7~2) 6~9 (7~2) 6~9 (7~2) Heating Indoor DB Min -Max F ( ) 2~6 (~) 2~6 (~) 2~6 (~) 2~6 (~) 2~6 (~) 2~6 (~) 2~6 (~) Pipe onnection ize - Liquid in (mm) / (6.5) / (6.5) / (6.5) / (9.52) / (9.52) / (9.52) / (9.52) Pipe onnection ize - uction in (mm) / (9.52) /2 (2.7) /2 (2.7) 5/ (6) 5/ (6) 5/ (6) / (9) Face Area q. Ft..2.2.9 2.9.7.2 5.9 No. Rows Fins per inch 6 6 6 6 6 ircuits 7 7 9 Unit Width in (mm) 27.56 (7) 27.56 (7).65 (). () 5.5 (6) 7.2 (2) 55.2 () Unit Height in (mm) 7.7 (2) 7.7 (2).27 (2) 9. (29) 9. (29). () 7.2 () Unit Depth in (mm) 9.92 (56) 9.92 (56) 26.5 (67).7 (77).7 (77). (7).7 (5) Net Weight lbs (kg).56 (9.).56 (9.) 5 (2.5) 6.6 (9.) 6. (.) 9.7 (5.) 6 (7) Number of Fan peeds Airflow (lowest to highest) FM 7/2/26 76/22/5 // /7/7 7/9/ 72//2 26/7/25 ound Pressure (lowest to highest) db(a) // 5/7/9 5/7/9 5.5//.5/2/5.5 6/9.5/5.5 5/5/57 Max tatic Pressure In.WG..2.2..6.6.6. Field Drain Pipe ize O.D. in (mm) (25.) (25.) (25.) (25.) (25.) (25.) (25.) Performance may vary based on the outdoor unit matched to. ee the compatible outdoor units product data for Performance Data. OMPATIBILITY Indoor Unit DLFDAH9XAK DLFDAH2XAK DLFDAHXAK DLFDAH2XAK DLFLDAH6XAK DLFLDAHXAK DLFLDAH5XAK Outdoor Unit ingle Zone DLRAH9AAK DLRAH2AAK DLRAHAAK DLRAH2AAK DLLRAH6AAK DLLRAHAAK DLLRAH5AAK DLMRAHBAK Outdoor Unit Multi-zone DLMRAH27AK DLMRAH6DAK DLMRAHEAK pecifications subject to change without notice. 2

APPLIATI DATA UNIT ELETI elect equipment to either match or that can handle slightly less than the anticipated peak load. This provides better humidity control, fewer unit cycles, and less part load operation. For units used in spaces with high sensible loads, base equipment selection on unit sensible load, not on a total anticipated load. Adjust for anticipated room wet bulb temperature to avoid undersizing equipment. UNIT MOUNTING (INDOOR) Refer to unit Installation Instructions for further details. Unit leveling For reliable operation, units should be level in all planes. learance Provide adequate clearance for airflow as shown in Fig.. Unit location elect a location which provides the best air circulation for the room. These units should be positioned as accessible as possible above the ceiling. The unit return and discharge should not be obstructed by furniture, curtains, or anything which may cause unit short cycling or air recirculation. Duct the unit in the middle of the selected wall (if possible). Duct towards an outside wall, if available, to make piping easier, and place the unit so it faces the normal location of room occupants. UNIT MOUNTING (OUTDOOR) Refer to unit Installation Instructions for further details. Do not install the indoor or outdoor units in a location with special environmental conditions. For those applications, contact your ductless representative. MOUNTING Refer to unit s Installation Instructions for further details. UPPORT Adequate support must be provided to support the weight of all fan coils. Refer to the Physical Data section for fan coil weights, and the base unit dimensional drawings for the location of mounting brackets. YTEM OPERATING DITI OPERATING RANGE Min / Max F ( ) ooling Heating Indoor DB 6 / 9 (7 / 2) 2 / 6 ( / ) Indoor WB 59 / (5 / 29) NOTE: Reference the product Installation Instructions for more information. WIRING All wires must be sized per NE (National Electrical ode) or E (anadian Electrical ode) and local codes. Use Electrical Data table MA (minimum circuit amps) and MOP (maximum over current protection) to correctly size the wires and the disconnect fuse or breakers respectively. Recommended onnection Method for Power and ommunication Wiring: The main power is supplied to the outdoor unit. The field supplied / stranded wire with ground with a 6 volt insulation rating, power/communication wiring from the outdoor unit to indoor unit consists of four () wires and provides the power for the indoor unit. Two wires are line voltage A power, one is communication wiring () and the other is a ground wire. Wiring between indoor and outdoor unit is polarity sensitive. The use of BX wire is NOT recommended. If installed in a high Electromagnetic field (EMF) area and communication issues exists, a /2 stranded shielded wire can be used to replace L2 and () between outdoor unit and indoor unit landing the shield onto ground in the outdoor unit only.! EQUIPMENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Wires should be sized based on NE and local codes.! AUTI AUTI EQUIPMENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Be sure to comply with local codes while running wire from the indoor unit to the outdoor unit. Every wire must be connected firmly. Loose wiring may cause the terminal to overheat or result in unit malfunction. A fire hazard may also exist. Ensure all wiring is tightly connected. No wire should touch the refrigerant tubing, compressor or any moving parts. Disconnecting means must be provided and shall be located within sight and readily accessible from the air conditioner. onnecting cable with conduit shall be routed through the hole in the conduit panel. DRAIN NETI Install drains to meet local sanitation codes. The standard ducted fan coil unit condensate lift pump has a maximum lift of 29.5 in. (75mm). pecifications subject to change without notice. 2 9

TROL YTEM The indoor unit is equipped with a microprocessor control to perform two functions:. Provide safety for the system 2. ontrol the system and provide optimum levels of comfort and efficiency The main microprocessor is located on the control board of the fan coil unit (outdoor units have a microprocessor also) with thermistors located in the fan coil air inlet and on the indoor coil. Heat pump units have a thermistor on the outdoor coil. These thermistors monitor the system operation to maintain the unit within acceptable parameters and control the operating mode. WIRELE REMOTE TROL. A wireless remote control is supplied for system operation for system operation of all ducted units. 2. Each battery operated wireless (infrared) remote control may be used to control more than one unit. WI REMOTE TROL P/N KANAAA (optional available as an accessory) P/N KAN5AAA (included with the Unit). Wired remote controller used for system operation of all ducted units. 2. Kit includes a wired remote controller and a connecting cable. NOTE: Extension wire available through RD (KANAAA Part Number: 726; KAN5AAA Part Number: 72769).. onnect with wire terminal between remote controller and indoor unit.. Display in F or and temperature increments every F or every. Fig. 5 - KANAAA (Timer Function) AIR FLOW DATA Indoor(FM) ystem size OUND PREURE ooling operation Indoor ound Pressure Heating operation Indoor ound Pressure 9K (2/2V) 2K (2/2V) K (2/2V) Fig. 6 - KAN5AAA (7 Day Programmable) 2K (2/2V) 6K (2/2V) K (2/2V) 5K (2/2V) Turbo Mode 29 2 / / / / 2 High 26 5 7 2 25 Medium 22.5 7 9 7 Low 7 76.5 7 72 26 dba at (Turbo /High / Med /Low FM) dba at (Turbo /High / Med /Low FM) 9K (2/2V) 2K (2/2V) K (2/2V) 2K (2/2V) 6K (2/2V) K (2/2V) 5K (2/2V) 7/// /9/7/5 /9/7/5 6///5.5.5/5.5/2/.5 9.5/5.5/9.5/6 5./57./5.9/5.2 /9/5/ 6/7/6/ 9/7/6/.9/.9/9.2/6.7./5.//9. 9./5./.5/5. 56.9/56.9/5.7/5.6 OUND PREURE TETING METHOD Unit Outlet Indoor Unit.2 ft (m) x.2 ft (m) Microphone Fig. 7 - ound Pressure Testing Method pecifications subject to change without notice. 2

OUND POWER ystem size ooling Operation Indoor ound Power Heating Operation Indoor ound Power ooling Operation Indoor ound Power (Turbo Mode) Heating Operation Indoor ound Power (Turbo Mode) dba (@ High FM) dba (@ High FM) dba (@ High FM) dba (@ High FM) 9K (2/2V) 2K (2/2V) K (2/2V) 2K (2/2V) 6K (2/2V) K (2/2V) 5K (2/2V) 55. 59.5 6 66.9 69.6 7. 76.2 6.2 6. 62.6 6.2 7. 7.6 7. 5. 5.5 6 65.9 6.6 69. 75.2 59.2 62. 6.6 67.2 69. 7.6 7. ELETRIAL DATA UNIT IZE INDOOR FAN V-PH-HZ FLA HP W 9K.. 2K.. K.2.27 6 2K 2-2//6.2.27 6 6K 2.5.56 2 K.2.75 5K.65.952 LEGEND FLA - Full Load Amps MAX FUE B AMP Refer to outdoor unit installation instructions Indoor unit powered by the outdoor unit FAN AND MOTOR PEIFIATI Ducted ize 9K 2K K 2K 6K K 5K (2/2 V) (2/2 V) (2/2 V) (2/2 V) (2/2 V) (2/2 V) (2/2 V) Material Plastic Plastic Metal Metal Metal Metal Metal Type LX-5*5 LX-5*5 FLBJ-5* FLBJ-2* FLBJ-2*266* FLBJ-2*26* FLBJ-227*2* *5-J *5-J 5*2-9*2-6 2.7-6 2.7-2.7- Diameter inch 5.9 5.9 6.6 inch 7.7 inch 7.7 inch 9.6 inch.9 Height inch 5.9 5.9 6.22 inch 7. inch.7 inch.9 inch 9.2 Model ZKFN-55- ZKFN-55- ZKFN-6 ZKFN-6 ZKFN--- ZKFN-56-- ZKFN-7-- -22-22 ---2 ---2 - Volts V 2/2 2/2 2/2 2/2 2/2 2/2 2/2 Type D D D D D D D Phase FLA...65.65 2.5..65 Insulation class E E E E E E B afe class IPX IPX IPX IPX IPX IPX IPX Input W 2 2 2 Output W 55 55 6 6 56 7 Range of current Amps ±% ±%.2±%.2±% 2.5±%.2±%.65±% Rated current Amps...2.2 2.5.2.65 apacitor µf No apacitor Rated HP HP...27.27.56.75.952 peed rev/min -5-5 5/7/5 /2/69 /5/99 9/2/ 6/9/79 Rated RPM rev/min 5 5 2 2 6 Max. input W 6 6 2 pecifications subject to change without notice. 2

WIRING DIAGRAM W FOR ETTING NETADDRE +2 WIRING DIAGRAM (INDOOR UNIT) FOR ANTI-OLD WIND TEL 2 5 FATORY ETTING EEPROM AULT FOR ETTING AUTO-RETART W MODE AUTO-RETART NOT AUTO-RETART FATORY ETTING FOR TEMP. OMPENATI(HEATING) W6 ODE 6 2 FATORY ETTING ODE ~F ~F NETADDRE ~5 6~ ~F 2~7 ~F ~6 FATORY ETTING A FAN M 5 WHITE WHITE (GRAY) BLAK AP BROWN M FAN D MOTOR 2 DRIVER MODLE D FAN N Reactor EEPROM AULT N N WIRE TROLLER N P2 P MAGNETI RING N5 To M omm.bus N FAN FOR THE FREH AIR OR ANI GENERATOR Fig. - Wiring Diagram izes 9 2 Alarm Remote Output ontrol ALARM /OFFJ7 NOTE:.The parts with dotted line indicates optional features. 2.Remove the short connector of J7 when you use the "on-off" function. N N N2 N 2 M PUMP DIPLAY 5 WIRE N BOARD TROLLER T2 INDOOR UNIT N6 BLAK INDOOR OIL TEMP. ENOR MAINBOARD T WHITE ROOM TEMP. ENOR N5 WATER LEVEL WITH N N9 YELLOW(WHITE) N2 N2 BLAK X Y E N YELLOW YELLOW BLAK L L2 MAGNETI RING BLAK TO OUTDOOR UNIT N6 N5 RL2 N N R RL N2 N HEATER F FOR ETTING NETADDRE +2 WIRING DIAGRAM (INDOOR UNIT) FOR ANTI-OLD WIND W TEL 2 5 FATORY ETTING EEPROM AULT FOR ETTING AUTO-RETART W MODE AUTO-RETART NOT AUTO-RETART FATORY ETTING FOR TEMP. OMPENATI(HEATING) W6 ODE 6 2 FATORY ETTING ODE ~F ~F NETADDRE ~5 6~ ~F 2~7 ~F ~6 FATORY ETTING A FAN M 5 WHITE WHITE (GRAY) BLAK AP BROWN FAN D MOTOR 2 DRIVER MODLE D FAN N M EEPROM AULT N N WIRE TROLLER N P2 P N5 Reactor To M omm.bus N FAN FOR THE FREH AIR OR ANI GENERATOR Fig. 9 - Wiring Diagram ize 2 Alarm Remote Output ontrol ALARM /OFFJ7 NOTE:.The parts with dotted line indicates optional features. 2.Remove the short connector of J7 when you use the "on-off" function. N N N2 N 2 M PUMP DIPLAY 5 WIRE N BOARD TROLLER T2 INDOOR UNIT N6 BLAK INDOOR OIL TEMP. ENOR MAINBOARD T WHITE ROOM TEMP. ENOR N5 WATER LEVEL WITH N N9 YELLOW(WHITE) N2 N2 BLAK X Y E N YELLOW YELLOW BLAK L L2 MAGNETI RING BLAK TO OUTDOOR UNIT N6 N5 RL2 N N R RL N2 N HEATER F 2 pecifications subject to change without notice. 2

WIRING DIAGRAM (T) WIRING DIAGRAM FOR ANTI-OLD WIND W EN FOR ETTING NETADDRE +2 TEL 2 5 EEPROM AULT FATORY ETTING N5 FOR ETTING AUTO-RETART FAN N W WHITE WHITE P2 MODE AUTO-RETART NOT AUTO-RETART (GRAY) BLAK FATORY ETTING AP BROWNP FOR MAIN-LAVE ETTING FOR TEMP. OMPENATI(HEATING) W5 MAIN MODE NO LAVEMAINMAINLAVE FATORY FATORY ETTING ETTING FOR ETTING POWER(D MOTOR MODEL LY) ODE 5 7 9 A B POWER 5 5~772~9 9~56~ ~6 6 FATORY ETTINGAORDING TO RELATED MODEL. W6 ODE 6 2 M 5 N ODE ~F ~F ~F ~F To M NETADDRE ~5 6~ 2~7 ~6 omm.bus FATORY ETTING OMM.BU Fig. - Wiring Diagram ize 6 FAN M EEPROM AULT D MOTOR DRIVER MODLE FAN 2 N REATOR N WIRE TROLLER INDOOR UNIT MAINBOARD N9 X Y E N2 ALARM /OFFJ7 N NN2 2 FAN FOR THE FREH AIR OR ANI GENERATOR N TO OUTDOOR ALARM REMOTE OUTPUT TROL N N 5 N2 N DIPLAY BOARD N6 BLAK N7 N5 MAGNETIYELLOW RING N2 N6 N N R RL2 YELLOW N5 RL N2 N HEATER F BLAK NOTE:.The parts with dotted line indicates optional features. 2.Remove the short connector of J7 when you use the "on-off" function. 2 M PUMP BLAK WIRE TROLLER T2 INDOOR OIL TEMP. ENOR T WHITE ROOM TEMP. ENOR T2B INDOOR OIL OUTLET TEMP. ENOR WATER LEVEL WITH BLAK L L2 MAGNETI RING TO OUTDOOR UNIT 6272 WIRING DIAGRAM FOR ANTI-OLD WIND W EN ODE POWER FOR ETTING NETADDRE FOR ETTING POWER(D MOTOR MODEL LY) 5 7 9 A B 5 5~7 72~9 9~5 6~ ~6 6 FATORY ETTING AORDING TO RELATED MODEL. TEL 2 5 FATORY ETTING FOR ETTING AUTO-RETART W EEPROM AULT MODE AUTO-RETART NOT AUTO-RETART FATORY ETTING FOR MAIN-LAVE ETTING W5 MAIN MODE NO LAVE MAIN FATORY ETTING MAIN LAVE FOR TEMP. OMPENATI(HEATING) W6 FATORY ETTING ODE 6 2 FAN M FAN M 5 WHITE WHITE (GRAY) BLAK AP BROWN EEPROM AULT FAN D MOTOR DRIVER MODLE 2 N N P2 P N5 HB HA N N5 INDOOR UNIT MAINBOARD N REATOR N9 FAN FOR THE FREH AIR OR ANI ALARM REMOTE GENERATOR OUTPUT TROL X Y E N ALARM /OFF J7 N N2 2 N M PUMP N2 2 N N6 N7 N5 N MAGNETI RING N2 N NOTE:.The parts with dotted line indicates optional features. 2.Remove the short connector of J7 when you use the "on-off" function. DIPLAY BOARD BLAK WHITE BLAK 5 WIRE TROLLER T2B T2 INDOOR OIL TEMP. ENOR T ROOM TEMP. ENOR INDOOR OIL OUTLET TEMP. ENOR WATER LEVEL WITH L L2 +2 ODE ~F ~F ~F ~F NETADDRE ~5 6~ 2~7 ~6 FATORY ETTING WIRE TROLLER WIRE TROLLER To M omm.bus TO OUTDOOR OMM.BU L L2 L L2 MAGNETI MAGNETI RING RING TO OUTDOOR UNIT FOR OUTDOOR POWER UPPLY POWER Fig. - Wiring Diagram ize 5 pecifications subject to change without notice. 2

GUIDE PEIFIATI INDOOR DUTED TYLE DUTLE UNIT ize Range: / to 5 Ton Nominal ooling and Heating apacity Model Number: DLFDA and DLFLDA PART GENERAL. ystem Description Indoor, ducted, direct expansion fan coils are matched with a heat pump outdoor unit..2 Agency Listings Unit is rated per AHRI tandards 2/2 and listed in the AHRI directory as a matched system.. Delivery, torage, And Handling Units are stored and handled per unit the manufacturer s recommendations.. Warranty (For Inclusion By pecifying Engineer) PART 2 PRODUT 2. Equipment A. General: Indoor, direct expansion, ceiling mounted fan coil. The unit is complete with cooling/heating coil, fan, fan motor, piping connectors, electrical controls, microprocessor control system, and integral temperature sensing. B. Unit abinet: Unit cabinet is constructed of galvanized steel. The cabinet is fully insulated for improved thermal and acoustic performance.. Fans: The fan is tangential direct drive blower type with air intake at the rear or bottom of the unit and discharge at the front. D. oil: The coil is a copper tube with aluminum fins and galvanized steel tube sheets. The fins are bonded to the tubes by mechanical expansion and specially golden hydrophilic pre coated for enhanced wet ability. A drip pan under the coil has a factory installed condensate pump and drain connection for hose attachment to remove condensate. E. Motors: The motors has an open drip proof, permanently lubricated ball bearing with inherent overload protection. Fan motors are speed. F. ontrols: The controls consist of a microprocessor based control system which controls the space temperature, determines optimum fan speed, and runs self diagnostics. The temperature control range is 62 F to 6 F (7 to ) in increments of F or, and has a 6 F Heating Mode (Heating etback). The wireless remote controller can act as the temperature sensing location for room comfort. The unit has the following functions as a minimum:. An automatic restart after power failure at the same operating conditions as at failure. 2. A timer function to provide a minimum 2 hour timer cycle for system Auto tart/top.. Temperature sensing controls sense return air temperature.. Indoor coil freeze protection. 5. Wireless infrared remote control to enter set points and operating conditions. 6. Dehumidification mode provides increased latent removal capability by modulating system operation and set point temperature. 7. Fan only operation to provide room air circulation when no cooling is required.. Diagnostics provide continuous checks of unit operation and warn of possible malfunctions. Error messages appear on the unit. 9. The fan speed control is user selectable: high, medium, low, or microprocessor controlled automatic operation during all operating modes.. Automatic heating to cooling changeover in heat pump mode. The control includes deadband to prevent rapid mode cycling between heating and cooling.. Indoor coil high temperature protection is provided to detect an excessive indoor discharge temperature when unit is in the heat pump mode. G. Electrical Requirements: The indoor fan motor operates on 2 2V. Power is supplied from the outdoor unit. H. Operating haracteristics: The system has a minimum EER (easonal Energy Efficiency Ratio) and HPF at AHRI conditions, as listed on the specifications table. I. Refrigerant Lines: All units have refrigerant lines that can be oriented to connect from the side of the unit. Both refrigerant lines need to be insulated. opyright 2 International omfort Products Lewisburg, Tennessee 79 UA www.goomfortmaker.com pecifications subject to change without notice. 2