Installation Instructions for. OmniFount

Similar documents
Installation Instructions for. OmniFount

Installation Instructions for. OmniFount

Installation Instructions for. CattleMaster Series Fountains

Installation Instructions for. DairyFount Series Fountains

Installation Instructions For

Installation Instructions For

Installation Instructions for. WaterMatic Fountains

Installation Instructions for. WaterMaster Series Fountains

Installation Instructions for. WaterMaster Series Fountains

Instruction Manual for. WaterMatic

READ ALL DIRECTIONS CAREFULLY BEFORE BEGINNING INSTALLATION

READ ALL DIRECTIONS CAREFULLY BEFORE BEGINNING INSTALLATION

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

READ ALL DIRECTIONS CAREFULLY BEFORE BEGINNING INSTALLATION

Energy-Free Waterers SF-2C, SF-4C, EF-2C, EF-4C

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

READ CAREFULLY INSTALLATION INSTRUCTIONS AND SPECIFICATIONS FOR MODEL 3345-E

SAVE THESE INSTRUCTIONS

Installation Instructions

Dishwasher Installation Instructions DW 24XT/DW 24XV

ST. KITTS CEILING FAN

Installation Instructions

Unpacking and removing shipping bolts. Connecting the drain line Leveling the washer Connecting to the power supply

Top Control Dishwasher

Dishwasher Installation Manual

Installation Instructions

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

INSTALLATION INSTRUCTIONS

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

HE120, HE160 Humidifier Installation Kit

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S

Installation Instructions

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

INSTALLATION MANUAL LITTLE BUTLER HOT WATER AND DRINKING WATER FILTRATION FAUCETS LB13250 LB13150 DW13050

Installation Instructions

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR-DWSH01-S

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

Camarillo 52 Ceiling Fan

FLCH4R Garage and Utility Electric Heater

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

L A signature series TA T N E RE O, A L L A T S IN

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

Panel Fan Series Operators Manual (Galvanized and Polymer)

HE360 Humidifier Installation Kit

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

Torrena 42 Ceiling Fan

Hanson LED C e i l i n g F a n

OPERATIONS MANUAL & PARTS LIST. BX2 Fastracts Extractor. IPC Eagle 3650 Dodd Rd, Eagan MN

2 Installation Instructions For Vari-Fan Ceiling Fans Installation Instructions For Vari-Fan Ceiling Fans 11

OWNERS GUIDE TO INSTALLATION AND OPERATION

Model: EF34. Owner's Guide & Installation Manual

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

SERIES WATERERS INSTALLATION INSTRUCTIONS

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Installation Manual PS-225 & PS-275

Pump Out Vacuums Polyethylene & Steel

DISHWASHER INSTALLATION INSTRUCTIONS

TILGHMAN CEILING FAN ITEM # MODEL #WCK44NWZ5L1. español p. 21 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

ELSTON 52 CEILING FAN

Oahu Showerspa Model #1035 Owner's Manual

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

Instant Hot Water Dispenser Owner s Manual

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

Installation Manual PS-200 & PS-201

Installation Instructions Built-In Dishwasher

TOUCHDOWN 48 CEILING FAN

600 Floor Stripper Applicator

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

OWNER S MANUAL WASHING MACHINE

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

Canister Vacuums S6EVO. Operations and Parts Manual. Models: S6EVO

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Troubleshooting the MPH 24FP Series Pedestal Hydrant

IMPORTANT SAFETY INSTRUCTIONS

HE220, HE260 Humidifier Installation Kit

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Installation instructions Built-in. Dishwasher READCAREFUL KEEPTHESE INSTRUCTIONS. Model(s): DDW2405BL. IMPORTANT: The dishwasher MUST be installed to

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

B.I.C.A Built-In Coffee Appliance

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

Transcription:

Installation Instructions for OmniFount Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly installed and maintained. Please follow instructions carefully. Read and understand all instructions before installing Ritchie Industries, Inc. 800-747-0222 www.ritchiefount.com Part # 17835 October 31, 2016 @RitchieWaterers

OmniFount 1, 2 and 2 SP; OmniFount 3, 5 and 10 Installation Instructions A. Location - Putting the fountain in a location that offers protection from the wind will enhance the performance of the fountain. Livestock will tend to gather in this protected area, enticing them to drink more. Access panel should be opposite of prevailing winter wind to give additional protection to the supply line. B. Water Supply Line - Horizontal underground water line should be sized to account for pressure drop, relating to distance, and placed one foot below frost line. A one-inch vertical supply pipe is recommended. A shut-off valve should be installed under fountain to allow for easier servicing. For optimum serviceability, a stop and waste valve can be installed below frost level to drain water when unit is not in use. Vertical supply line must be centered in riser tube to provide an air space between the line and frozen ground outside of tube. Flush water supply line thoroughly before connection to fountain. Water supplies with foreign material such as sand, rust, etc. may require a filter to keep fountain valve working properly. C. Electric Supply It is generally most cost effective to run your electrical supply line at the same time you are trenching for your water supply. WARNING: ANY ELECTRICAL SERVICE MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED ELECTRICIAN. D. Riser Tube - Install a riser tube and extend it at least one foot below frost line or down to horizontal underground water line. For optimum water line protection, use the 12 diameter insulated Ritchie Thermal Tube, part numbers and sizes are shown to the right. Tube opening must be kept clear. NOTE: The supply line touching the riser tube is the most common cause of the supply line freezing. Do not surround the supply line with insulation, wood, or other foreign material. Any foreign material in the tube may cause frost to migrate to the supply line causing it to freeze. Ritchie Thermal Tube Part # Description 18158 1 Top Section 16417 2 Top Section 16612 4 Top Section 16416 2 Extension OmniFount Series Instruction Manual 1 October 31, 2016

E. Mounting Platform - A concrete platform must be provided for all fountains. Use a minimum of 4 thick, (6 recommended thickness), large enough to accommodate fountain, and additional 4 step (on top of the platform) extending 18 out from each side of the unit. This will protect the unit from manure handling equipment, as well as discouraging animals from defecating in the fountain. Extending the platform provides animals a place to stand while drinking, consider the size of your animals when determining the dimensions of your platform. The concrete step and platform should slope away from the fountain for drainage. A rough broom finish to concrete surface provides better footing for livestock. F. Hose Connection - Connect hose fitting to shut-off valve at top of concrete. Slip on barb fitting with furnished clamps. Hose should not touch insulation or outside surface of fountain. Place the hose under the fountain as you move the unit in place over the riser tube. G. Preparing the bottom - Apply the provided foam weather stripping to the bottom of the unit, along the outside edge of the fountain. H. Anchoring Fountain OmniFount 1 is provided with 3 hold-down pockets to anchor the unit securely to the concrete. OmniFount 2, OmniFount 2 SP & OmniFount 3 are provided with four hold-down pockets and the OmniFount 5 & 10 have 6 molded hold-down pockets. The use of 3/8 x 5 stainless steel expansion anchor bolts (not included) is recommended. Anchor bolts are available from Ritchie in a two pack, part #16555. Large diameter fender washers are included and should be used with anchor bolt to prevent damage to the plastic casing. Remove the side access panel to prepare for the remainder of the installation process. I. Valve Assembly for Omni 3, Omni 5 & Omni 10 The valve assembly can be put together before proceeding. The following instructions apply to the OmniFount 3, 5 & 10 (Omni 1, 2 & 2 SP are pre-assembled) 1. Install standpipe into hole in trough. Rubber washer is to be on inside of trough. Tighten nut hand tight to allow for adjustment after valve assembly is installed. 2. Feed hose up through standpipe and attach to valve bracket. The hose may be shortened if necessary. Tighten the hose clamp securely to prevent leaks. 3. The lower front peg on valve bracket should be inserted into hole on standpipe first. Compress valve clip to snap in opposite hole on standpipe. 4. Remove pin from valve assembly. 5. Install float assembly on valve assembly using previously removed pin. 6. Rotate standpipe in trough until center of float aligns with center of trough. DO NOT allow float to be too close to cover when installed as this may hamper valve performance. 7. Tighten standpipe nut hand tight plus one-quarter turn. Use no joint compound for this fitting. OmniFount Series Instruction Manual 2 October 31, 2016

J. Final Water Connection Connect the top of the supplied hose to the valve, cut hose to proper length, and slip onto the barb fitting of the valve assembly. Clamps and fittings are furnished to secure the connection. K. Cable Heater Uncoil cable heater and loop around the valve. Attach the remaining part of the cable heater to the water supply, as far down the riser tube as possible with the cable twist ties provided. This heater is water tight, but should not be immersed in water. Heater may cross over itself, but should not be tightened at those locations. 1/2" Valve Cable Heater Setup 3/4" Valve Cable Heater Setup CAUTION: Installation must not cause any strain on heater wiring connections. Avoid heater damage caused by hot spots due to its leads lying too close to each other. Also, do not wrap additional insulation around heater. L. Electrical Connection - The electrical installation should be made and maintained by a qualified electrician conforming to national and local codes. A means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. For wiring connections, see wiring diagram. Make connections according to the wiring diagram below. WARNING: DISCONNECT POWER IF THE WATER SUPPLY IS TO BE SHUT OFF FOR AN EXTENDED AMOUNT OF TIME. FAILURE TO TURN OFF POWER CAN RESULT IN DAMAGE TO THE WATERING FOUNTAIN. WARNING: THIS INSTALLATION MUST BE MADE AND MAINTAINED IN STRICT CONFORMITY WITH NATIONAL/LOCAL PLUMBING CODES AND NATIONAL/LOCAL ELECTRICAL CODES (CSA IN CANADA). THE APPLICABLE PROVISIONS OF THESE CODES TAKE PRECEDENT. FAILURE TO MAKE AND MAINTAIN ALL INSTALLATIONS PROPERLY MAY RESULT IN LOSS OF LIVESTOCK, PERSONAL INJURY, OR DEATH. NOTE: National/Local electrical codes may require livestock waterers installed in feedlots in open feeding area to be grounded by a separate stranded copper grounding conductor or at least no.6 AWG terminating at a point where the branch circuit receives its supply. Check with local authorities. OmniFount Series Instruction Manual 3 October 31, 2016

WIRING DIAGRAM 120V SINGLE PHASE WIRING DIAGRAM 240V SINGLE PHASE OmniFount Series Instruction Manual 4 October 31, 2016

Fenwal Thermostat (Omni 3, Omni 5 & Omni 10) The adjustable range is from 0 o. F (-18 o C) to 100 o F (38 o C). Thermostat is not preset at factory. Fill the trough to proper water level. Check the water temperature with a thermometer. The next morning, check the water temperature again. If the water is warmer than desired, turn the thermostat down. If there is ice forming on the surface of the water, turn the thermostat up. Only slight adjustments should be made to the thermostat at any time. A 1/16 turn on the thermostat will change the water temp. 7 o F (4 o C). 44 o F (7 o C) in the trough represents the most economical operation. Counter clockwise raises the thermostat setting. M. Disc Thermostat (Omni 1, Omni 2 and Omni 2 SP) The disc thermostat is mounted in a bracket under the trough, which allows it to be moved relative to the heater. To ease movement of thermostat turn ¼ turn. To lock in position after adjustment turn ¼ turn back. As the thermostat is moved toward the heater, the water temperature in the trough is lowered. The best location is determined by checking the trough temperature several times during the heating season. N. Final Water Connection for Omni 1, Omni 2 and Omni 2 SP Only Connect the top of the supplied hose to the valve, cut hose to proper length and slip onto the barb fitting of the valve assembly. Clamps and fittings are furnished to secure the connection. (This connection was already made in step H for the Omni 3 & 5.) O. Seal the Base - After the unit is completely installed, apply a bead of caulking around the base of the fountain to ensure no wind enters through the base of the unit. NOTE: Sealing the bottom of the unit from cold air is an important aspect of the unit's thermal performance. P. Drain Plug Insert the drain plug firmly into the drain hole in the center of the trough. Q. Water Seal Drain Install the small drain plug into the drain hole in the water seal groove around the valve chamber seal. This plug may be removed during the non-freezing periods to allow the water seal groove to drain. R. Valve Frame and Cover (OmniFount 3 & 5) Before installing the valve chamber frame, the weather seal must be installed on the frame (see picture below). The seal is installed by removing the paper backing from the adhesive side and then starting at the midpoint of the frame leg; attach the seal to the frame. Work your way around the frame with the seal as close to the inside edge as possible and then up the other leg to the halfway point. At this time cut any extra foam seal as needed then repeat for other side. The frame can then be attached to the casing using the screws and nuts provided in parts bag. A washer should be used on the head of the screw as well as under the nut. Tighten securely. NOTE: The foam seal must be placed on the omni 3 & 5 frame as shown in the picture to the right. The foam seal is to prevent cold air from leaking into the valve chamber and causing the valve to freeze. OmniFount Series Instruction Manual 5 October 31, 2016

S. Float Adjustment Open water-supply shut-off valve, check for and fix any leaks. Adjust float for a water depth of 2 inches below top of trough or overflow pipe by adjusting the thumbscrew or wing-nut. With the valve functioning properly and the water level set at the proper level, you may install the valve cover. The water seal groove between the frame and valve cover must be filled with liquid to create a protective seal from cold winter air getting to the valve. T. Install Side Access Panel Once all water line connections have been checked for leaks and electrical hookup is complete, the side access door may be installed. U. Children should be supervised to ensure that they do not play with the appliance This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions concerning use of the appliance by a person responsible for their safety. V. Cleaning Your Fountain To clean your watering fountain you will need a good stiff bristled brush. Remove the cover then brush the water seal groove to remove any build-up then brush the tank. Remove the plug that is located in the valve chamber area under the float to drain out the water and debris. You can shut off the water with the shut-off valve located under the unit or by holding the float in the up position. After the water and debris has drained reinstall the plug and let the tank refill. Now is a good time to readjust the float if needed. Reinstall cover and you are done. Ritchie Valves Ritchie valves come in various sizes and pressure ratings as shown below - green for high supply line pressure, red for moderate supply pressure, and white for low-pressure applications. Differences in the size of trough also impacts valve choice. Although different pressure rated valves may be used in a fountain, each fountain will only accommodate one size and configuration of valve. Your individual situations may require a change from the standard valve supplied with your fountain, see your Ritchie Dealer if this is needed. NOTE: The red ½ valve is standard on the OmniFount 1, 2 & 2 SP and the green ¾ valve is standard on the OmniFount 3, 5 & 10. 1/2 Part # GPM Pressure Range White 12574 4.8 Low, 5-40 psi. (34-275 kpa) Red 12575 3.4 Moderate, 40-60 psi. (275-414 kpa) Green 13597 1.45 High, 60-80 psi. (414-552 kpa) 3/4 Part # GPM Pressure Range White 16697 33 Low, 5-40 psi (34-275 kpa) Red 11101 20 Moderate, 40-60 psi (275-414 kpa) Green 15377 16.5 High, 60-80 psi (414-552 kpa) NOTE: Maximum inlet water pressure for each valve is shown above. If water pressure is extremely high, and if the valve does not shut off, a pressure-reducing valve may be needed. OmniFount Series Instruction Manual 6 October 31, 2016

1 OmniFount 1 Part # 18359 15 14 2 21 10 16 4 17 8 7 3 11 12 13 18 5 6 20 19 9 For units manufactured prior to 2012. Item Part # Description Qty Item Part # Description Qty 1 18422 Omni 1 Cover 1 15 11515 Valve Bracket 1/2" w/ Scrws pkg 1 pkg 2 18473 Omni 1 Frame pkg 1 pkg 16 18066 Screws Valve Bracket (6/ pkg) 1 pkg 18474 Omni 1 Cover & Frame pkg 1 pkg 17 12575 Red Valve 1/2" pkg 1 pkg 3 18361 Omni 1 Casing 1 18 13613 Float with Short Arm pkg 1 pkg 4 18368 Omni 1 Trough 1 pkg 19 18318 Bolt Down Washer (4/pkg) 1 pkg 5 18370 Access Panel 10"x10" 1 20 17500 Drain Pipe Guard 1 6 18147 Access Panel Hardware pkg 1 pkg 21 18633 Plug #3 - Water Channel (2/pkg) 1 pkg 7 11885 Disc Thermostat pkg 1 pkg NS 13830 Cable Htr 120V 48W (1/pkg) 1 pkg 8 18266 Frame Bolt,nut&wshr SS(3/pkg) 1 pkg NS 16627 Omni 1 Accessory pkg 1 pkg 9 18655 Ritchie Decal 7.5" (1/pkg) 1 pkg NS 16523 Seal Foam 1/4"x3/4"x25' Roll 1 10 18628 Drain Plug (2/pkg) 1 pkg NS 14866 Seal Foam 1/2"x3/4"x10' Roll 1 11 14150 Heater 120V 125W (1/pkg) 1 pkg 12 18075 Drain Washer (6/pkg) 1 pkg 18362 OMNI 1 240V 1 pkg 13 11471 Drain Pipe with Elbow 1 NS 16664 Heater 240V 200W (1/pkg) 1 pkg 14 16866 Standpipe pkg 1 pkg NS 16424 Cable Htr 240V 48W (1/pkg) OmniFount Series Instruction Manual 7 October 31, 2016

1 OmniFount 2 SP Part # 18680 13 2 20 14 4 9 8 15 11 7 12 3 10 16 5 17 19 6 18 Item Part # Description Qty Item Part # Description Qty 1 18424 Omni 2 Cover 1 15 18066 Screws Valve Bracket (6/ pkg) 1 pkg 2 18347 Omni 2 Frame pkg 1 pkg 16 12575 Red Valve 1/2" pkg 1 pkg 18348 Omni 2 Cover & Frame pkg 1 pkg 17 13613 Float with Short Arm pkg 1 pkg 3 18684 Omni 2 SP Casing 1 18 18318 Bolt Down Washer (4/pkg) 1 pkg 4 16616 Omni 2 Trough 1 pkg 19 18653 Ritchie Decal 12" (1/pkg) 1 pkg 5 16621 Access Panel 6"x14" 1 20 18633 Plug #3 - Water Channel (2/pkg) 1 pkg 6 18147 Access Panel Hardware pkg 1 pkg NS 13830 Cable Htr 120V 48W (1/pkg) 1 pkg 7 11885 Disc Thermostat pkg 1 pkg NS 16627 Omni 2 Accessory pkg 1 pkg 8 18266 Frame Bolt,nut&wshr SS(3/pkg) 1 pkg NS 16523 Seal Foam 1/4"x3/4"x25' Roll 1 9 18628 Drain Plug (2/pkg) 1 pkg NS 14866 Seal Foam 1/2"x3/4"x10' Roll 1 10 14150 Heater 120V 125W (1/pkg) 2 pkg 11 18075 Drain Washer (6/pkg) 1 pkg 18681 OMNI 2 SP 240V 12 11471 Drain Pipe with Elbow 1 NS 16664 Heater 240V 200W (1/pkg) 2 pkg 13 16866 Standpipe pkg 1 pkg NS 16424 Cable Htr 240V 48W (1/pkg) 1 pkg 14 11515 Valve Bracket 1/2" w/ Scrws pkg 1 pkg OmniFount Series Instruction Manual 8 October 31, 2016

1 OmniFount 2 Part # 16619 15 14 8 4 2 21 10 16 17 12 13 7 11 3 5 18 9 20 6 For units manufactured prior to 2012. Item Part # Description Qty Item Part # Description Qty 1 18424 Omni 2 Cover 1 15 11515 Valve Bracket 1/2" w/ Scrws pkg 1 pkg 2 18347 Omni 2 Frame pkg 1 pkg 16 18066 Screws Valve Bracket (6/ pkg) 1 pkg 18348 Omni 2 Cover & Frame pkg 1 pkg 17 12575 Red Valve 1/2" pkg 1 pkg 3 16620 Omni 2 Casing 1 18 13613 Float with Short Arm pkg 1 pkg 4 16616 Omni 2 Trough 1 pkg 19 18318 Bolt Down Washer (4/pkg) 1 pkg 5 16621 Access Panel 6"x14" 1 20 17500 Drain Pipe Guard 1 6 18147 Access Panel Hardware pkg 1 pkg 21 18633 Plug #3 - Water Channel (2/pkg) 1 pkg 7 11885 Disc Thermostat pkg 1 pkg NS 13830 Cable Htr 120V 48W (1/pkg) 1 pkg 8 18266 Frame Bolt,nut&wshr SS(3/pkg) 1 pkg NS 16627 Omni 2 Accessory pkg 1 pkg 9 18653 Ritchie Decal 12" (1/pkg) 1 pkg NS 16523 Seal Foam 1/4"x3/4"x25' Roll 1 10 18628 Drain Plug (2/pkg) 1 pkg NS 14866 Seal Foam 1/2"x3/4"x10' Roll 1 11 14150 Heater 120V 125W (1/pkg) 2 pkg 12 18075 Drain Washer (6/pkg) 1 pkg 16844 OMNI 2 240V 13 11471 Drain Pipe with Elbow 1 NS 16664 Heater 240V 200W (1/pkg) 2 pkg 14 16866 Standpipe pkg 1 pkg NS 16424 Cable Htr 240V 48W (1/pkg) 1 pkg 19 OmniFount Series Instruction Manual 9 October 31, 2016

OmniFount 3 Part # 18270 1 7 2 21 15 16 10 9 18 4 8 17 12 11 14 13 3 5 20 19 6 Item Part # Description Qty Item Part # Description Qty 1 18418 Omni 3 Cover 1 15 11514 Valve Bracket 3/4" pkg 1 pkg 2 18345 Omni 3 Frame pkg 1 pkg 16 15377 Green Male Valve 3/4" pkg 1 pkg 18346 Omni 3 Cover & Frame pkg 1 pkg 17 18314 Float with Hardware pkg 1 pkg 3 18272 Omni 3 Casing 1 18313 Hardware for Float pkg 1 pkg 4 18342 Omni 3 Trough 1 pkg 18 16993 Green Valve & Float pkg 1 pkg 5 16562 Access Panel 10"x20" 1 19 18318 Bolt Down Washer (4/pkg) 2 pkg 6 18147 Access Panel Hardware pkg 1 pkg 20 18653 Ritchie Decal 12" (1/pkg) 1 pkg 7 16534 Fenwal Thermostat SS pkg 1 pkg 21 18633 Plug #3 - Water Channel (2/pkg) 1 pkg 18320 O-Ring Fenwal (6/pkg) 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18074 Nut Brass Fenwal (6/pkg) 1 pkg NS 13830 Cable Htr 120V 48W (1/pkg) 1 pkg 8 18319 Frame Bolt & Wshr SS(2/pkg) 1 pkg NS 16554 Omni 3 Accessory pkg 1 pkg 9 18095 Trough Screw & Nut SS (2/pkg) 1 pkg NS 16523 Seal Foam 1/4"x3/4"x25' Roll 1 10 18628 Drain Plug (2/pkg) 1 pkg NS 14866 Seal Foam 1/2"x3/4"x10' Roll 1 11 11419 Heater 120V 250W (1/pkg) 2 pkg 12 18075 Drain Washer (6/pkg) 1 pkg 18273 OMNI 3 240V 13 11472 Drain Pipe with Elbow 1 NS 11403 Heater 240V 300W (1/pkg) 2 pkg 14 16629 Standpipe pkg 1 pkg NS 16424 Cable Htr 240V 48W (1/pkg) 1 pkg OmniFount Series Instruction Manual 10 October 31, 2016

1 OmniFount 5 Part # 16533 2 21 15 16 7 10 9 18 4 17 8 11 3 12 14 5 20 13 6 19 Item Part # Description Qty Item Part # Description Qty 1 18426 Omni 5 Cover 1 15 11514 Valve Bracket 3/4" pkg 1 pkg 2 18343 Omni 5 Frame pkg 1 pkg 16 15377 Green Male Valve 3/4" pkg 1 pkg 18344 Omni 5 Cover & Frame pkg 1 pkg 17 18314 Float with Hardware pkg 1 pkg 3 16561 Omni 5 Casing 1 18313 Hardware for Float pkg 1 pkg 4 16631 Omni 5 Trough 1 pkg 18 16993 Green Valve & Float pkg 1 pkg 5 16562 Access Panel 10"x20" 1 19 18318 Bolt Down Washer (4/pkg) 2 pkg 6 18147 Access Panel Hardware pkg 1 pkg 20 18653 Ritchie Decal 12" (1/pkg) 1 pkg 7 16534 Fenwal Thermostat SS pkg 1 pkg 21 18633 Plug #3 - Water Channel (2/pkg) 1 pkg 18320 O-Ring Fenwal (6/pkg) 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18074 Nut Brass Fenwal (6/pkg) 1 pkg NS 13830 Cable Htr 120V 48W (1/pkg) 1 pkg 8 18319 Frame Bolt & Wshr SS(2/pkg) 1 pkg NS 16554 Omni 5 Accessory pkg 1 pkg 9 18095 Trough Screw & Nut SS (2/pkg) 1 pkg NS 16523 Seal Foam 1/4"x3/4"x25' Roll 1 10 18628 Drain Plug (2/pkg) 1 pkg NS 14866 Seal Foam 1/2"x3/4"x10' Roll 1 11 11419 Heater 120V 250W (1/pkg) 2 pkg 12 18075 Drain Washer (6/pkg) 1 pkg 16829 OMNI 5 240V 13 11473 Drain Pipe with Elbow 1 NS 11403 Heater 240V 300W (1/pkg) 2 pkg 14 16629 Standpipe pkg 1 pkg NS 16424 Cable Htr 240V 48W (1/pkg) 1 pkg OmniFount Series Instruction Manual 11 October 31, 2016

OmniFount 10 Part # 18460 21 1 7 2 15 16 8 10 9 18 17 4 11 3 14 5 12 13 20 6 19 Item Part # Description Qty Item Part # Description Qty 1 18462 Omni 10 Cover 1 15 11514 Valve Bracket 3/4" pkg 1 pkg 2 18464 Omni 10 Frame 1 16 15377 Green Male Valve 3/4" pkg 1 pkg 18472 Omni 10 Cover & Frame pkg 1 pkg 17 18314 Float with Hardware pkg 1 pkg 3 18466 Omni 10 Casing 1 18313 Hardware for Float pkg 1 pkg 4 18468 Omni 10 Trough 1 pkg 18 16993 Green Valve & Float pkg 1 pkg 5 16562 Access Panel 10"x20" 1 19 18318 Bolt Down Washer (4/pkg) 2 pkg 6 18147 Access Panel Hardware pkg 1 pkg 20 18653 Ritchie Decal 12" (1/pkg) 1 pkg 7 16534 Fenwal Thermostat SS pkg 1 pkg 21 18633 Plug #3 - Water Channel (2/pkg) 1 pkg 18320 O-Ring Fenwal (6/pkg) 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18074 Nut Brass Fenwal (6/pkg) 1 pkg NS 13830 Cable Htr 120V 48W (1/pkg) 1 pkg 8 18471 Frame Bolt & Wshr SS(4/pkg) 1 pkg NS 16554 Omni 10 Accessory pkg 1 pkg 9 18095 Trough Screw & Nut SS (2/pkg) 4 pkg NS 16523 Seal Foam 1/4"x3/4"x25' Roll 1 10 18628 Drain Plug (2/pkg) 1 pkg NS 14866 Seal Foam 1/2"x3/4"x10' Roll 1 11 11419 Heater 120V 250W (1/pkg) 4 pkg 12 18075 Drain Washer (6/pkg) 1 pkg 18461 OMNI 10 240V 13 11473 Drain Pipe with Elbow 1 NS 11403 Heater 240V 300W (1/pkg) 3 pkg 14 16629 Standpipe pkg 1 pkg NS 16424 Cable Htr 240V 48W (1/pkg) 1 pkg OmniFount Series Instruction Manual 12 October 31, 2016

Problem Water in Trough Too Warm Ice in Trough Trouble Shooting Solution Adjust thermostat to lower temperature Check to see if thermostat has failed by contacts burning closed Check fuses or circuit breakers Check all heating elements to make sure they are working and hot Adjust thermostat to higher temperature Check for voltage from thermostat output Check voltage to fountain with and without electrical load Check that heaters are wired properly Valve Freezing Supply line Freezing Valve won t stop dripping 1/2 Valve: Check that cable heater is installed properly and fastened to water supply line and is working when heaters are hot Check for missing or damaged insulation Check for air gaps for wind penetrations Check that the cable heater is uncoiled and fastened around valve, to supply line and is working when heaters are hot Check that supply piping is centered in riser tube Check that riser tube is free of water and mud that may freeze Check that flexible hose does not touch side of casing or frame Check casing for air leaks Check for air gaps between casing and concrete floor Check float adjustment. Check for waterlogged float, or float rubbing on side of valve compartment Check for excessive system water pressure Disassemble valve and check for sand or scale in valve rubber. Also check valve orifice outlet for wear and damage. A screen or filter may be required with sandy or scaly water Turn valve rubber over and re-assemble 3/4 Valve: Valve Rubber Pin must be pushed out of valve to Valve Rubber Low water flow Check that valve inlet is not plugged or supply hose is not kinked Check system pressure from supply hose by installing a tee and a pressure gauge directly in front of the valve to check pressure drop when valve is open. A severe pressure drop indicates a restriction or undersized supply system. Check that shutoff valves are fully open OmniFount Series Instruction Manual 13 October 31, 2016

Ritchie Limited Warranty Effective September 2012 Ritchie Industries, Inc. warrants its products to be free of defective materials and workmanship. Defective part(s) will be repaired or replaced at the option of Ritchie Industries. This warranty specifically excludes all labor and shipping charges. This warranty does not apply to any appearance items, to any product whose exterior has been damaged or defaced, to any product that has been improperly installed, to any product subjected to misuse, abnormal service or handling, and to any products altered or repaired with other than original equipment or manufacturer s parts. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. All warranty claims must be processed through an Authorized Ritchie Dealer/ Distributor. Proof of purchase is required. This warranty is not transferable. The period of warranty begins at original date of purchase as follows: Poly Units Base, top and ball closures 10 year limited against manufacturing defect. 100% first five years, then declining 20% per year for the remaining five years. Stainless Steel Units Stainless trough and stainless valve chamber frame: Ten years against manufacturing defect or corrosion. 100% all ten years. Casing and cover: 10 year limited against manufacturing defect. 100% first year, then declining 10% per year for the remaining nine years. Component Parts All component parts, such as floats, valves, heating elements: One year from the date of purchase against manufacturing defect, 100%. OmniFount Series Instruction Manual 14 October 31, 2016