Energy Saving Drives for Hot Strip Mills

Similar documents
How to Cut Chiller Energy Costs by 30%

Fans and Pumps I. Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong

Operational Overview and Controls Guide

E N E R G Y S AV I N G S

Continuous Commissioning: A Valuable Partner to Retrofit Projects

Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark

Application of ALPHA Inverter in the Transformation Plan of Central Air-Conditioning

PAPER INDUSTRY PROCESS DESCRIPTION

Trim Pump Impellers. Fredrick/Weinman Engineered Products 2-1/2 KH, 2-1/2 x 3 x 12

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Speed and Frequency Seite 1 von 7

OVEN INDUSTRIES, INC.

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

Pulse Firing Doubles Capacity and Cuts Fuel Costs

Smardt Oil-Free Chillers

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

Magnetic Bearing Technology: Achievements in Higher Efficiency

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

On Balance: Heat Rejection Control a Packaged Solution

6800 Design Envelope Booster. Technical overview

VLT 6000 HVAC Application Booklet

Screw Water Cooled Chiller SCW210

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.

Heat Link. Technical Guide

Reduced Order WECC Modeling for Frequency Response and Energy Storage Integration

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

Distributed Generation (greater than 10kW) Connecting to Vector s electricity network

MCH Series Drives. HVAC Application Guide. ag-mch-e2

Fan Selection. and Energy Savings

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Scroll Water Cooled Chiller

- Essay Control Functions and Benefits

Variable refrigerant flow (VRF) systems

Acknowledgement: Ralph Prahl, Prahl & Associates, contributed critical review and analysis

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

TEC Controller Unit Conditioner - Two-Pipe Fan Coil Cooling or Heating, Application Application Note Building Technologies

Flygt Top-Entry Agitators CONVENIENT AND EFFICIENT

James S. McMillen, P.E. Perkins Engineering Consultants, Inc., Arlington, Texas. May 25, 2012

Goulds Model 3500 Medium Consistency Pump Systems. Pump System Advantage PP-1D. Standpipe Arrangement

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

General HVAC Recommendations

Considerations for INDUSTRIAL COMBUSTION

Emerging Technologies: VFDs for Condensers. Douglas T. Reindl Director, IRC University of Wisconsin-Madison. University of Wisconsin-Madison

Verasys System Operation Overview Technical Bulletin

Guide To Troubleshooting INEFFICIENT COOLING FANS

TRACE 700. Slide 1. Hello, my name is Nick Cavitt and I m a marketing engineer in the C.D.S. group at TRANE.

PRESSURE INDEPENDENT CONTROL VALVE TECHNOLOGY. 3/16/2012 Fred Ferrara 1

Ammonia Detection System Codes and Design Specifications

Descaling Improvements at Charter Steel Cleveland Ohio. Presented by Chris Speckman IRD Conference April 2018

Cutting Edge Compressor Technology

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

BACnet PTEC Controller VAV 0 to 10V Series Fan and 3- Stage Electric Heat, Application 6657

Air Cooled Scroll Chiller / Heat Pump

CLIMA I Thermostat ZENNIO

WWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223

HEAT EXCHANGER FORMULAS & EXAMPLE

Temperature Control of Heat Exchanger Using Fuzzy Logic Controller

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

1 Introduction. Continue with any key. Process

Hydronic & HVAC Control Systems

TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies

Efficient Motor-Driven Appliances Using Embedded Adjustable-Speed Drives

at a glance Energy FinAnswer Case Study: Albertsons Energy FinAnswer is the best-run, best-delivered program we ve been involved with.

Correcting Low T in Buildings with District Cooling

APC APPLICATION NOTE #119

Management of In-Bin Natural Air Grain Drying Systems to Minimize Energy Cost

Varofoil Controllable Pitch in Motion Fans Compared to Variable Frequency Controlled Fans

- Data Brochure Universal Reset Module 422

TEC Controller Multiple Compressor Heat Pump with Reversing Valve & Mixed Air Control, Application Application Note

Agenda and Objectives

Automation and Energy Efficiency of Industrial Refrigeration Systems

Distributed By: M&M Control Service, Inc Building Technologies

HVAC System Consideration$ 05/14/2012 SAVING MONEY IN HVAC SYSTEMS

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Hebei Datang International Wangtan Power Company, China

Operating Instructions

Modern Centrifugation and the Maintenance of Wire Drawing Lubricants Presented By Tom Horn, Sales Manager, Filtertech, Inc. U.S.A.

Sustainable Techniques in Refrigerated Space

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

1900 Series In-Line Pump

Wet Well Mounted Pump Stations

Microgrid Fault Protection Based on Symmetrical and Differential Current Components

RC350. Glaston Flat Tempering

VertiCool Aurora Engineering Guide

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

Energy Efficient Fan and Dust Collection Systems

York 25-Ton VAV Rooftop Unit

CAD/CAM TECHNOLOGY. DC1 Milling System

Energy Benefits of Pulsation Stop Control on Dairy Farms

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Grain and Soybean Drying on Georgia Farms

NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart!

Chapter-8 Capacity Control of Refrigeration Systems

Better Design, Better Control, Better Systems.

3500 XD. Medium Consistency Pumping Technology Introducing X-Ducer Medium Consistency Pumping Technology

SECTION PACKAGED HEAT TRANSFER SYSTEM

Transcription:

Energy Saving Drives for Hot Strip Mills Ralph PUGH TMEIC 060 Cook Drive Salem, VA 4153, USA Tel: 540-83-158 Fax: 540-83-395 E-mail: ralph.pugh@tmeic.com Serkay ÖZALICI TOSÇELIK Osmaniye OSB Turkey Tel: +90 38 86 80 80 Fax: +90 38 86 80 09 E-mail: serkay.ozalici@toscelik.com.tr Hasan RAMANLI TOSÇELIK Osmaniye OSB Turkey Tel: +90 38 86 80 80 Fax: +90 38 86 80 09 E-mail: hasan.ramanli@toscelik.com.tr Tayfun ALTUNTOP TOSÇELIK Osmaniye OSB Turkey Tel: +90 38 86 80 80 Fax: +90 38 86 80 09 E-mail: tayfun.altuntop@toscelik.com.tr Marcelo LARA TMEIC 060 Cook Drive Salem, VA 4153, USA Tel: 540-83-13 Fax: 540-83-395 E-mail: marcelo.lara@tmeic.com Keywords: Medium Voltage Drive, Variable Frequency Drive, Energy Savings, Water Treatment, Descale INTRODUCTION In 010, Tosçelik HSM located near Osmaniye, Turkey, embarked on an ambitious plan to reduce electrical energy consumption and maintenance by upgrading several fixed speed motors with variable frequency drives (VFD). Although the HSM facility is fairly new, commissioned in 009, most of the pumps associated with water treatment, HSM descaling and HSM cooling were not designed to utilize a modern energy saving control system with variable speed drives. The pumps which were targeted for energy savings through implementation of an optimized control system and the application of variable speed drives were: Descaling pumps, Descale Booster pumps, Roll Cooling pumps, Laminar Cooling pumps, Runout Table Cooling and Side Spraying pumps, Scale Pit to Sedimentation Tank transfer pumps, and Sedimentation Tank to Direct Cooling (DC) Tank transfer pumps,. The variable speed drives and associated energy saving control system were commissioned by TMEIC in 0. This paper will review the equipment which was selected for this upgrade and present data which quantifies the energy saving benefit realized in each system. Figure 1. Descale and Cooling Water Flow Overview Showing Systems Targeted for VFD Application

BACKGROUND There are some general rules of thumb known as Pump Laws or Affinity Laws which establish simple relationships between volumetric flow, pressure (head), and power consumption for fans and pumps. According to these laws, for a fixed impeller, the volumetric flow (Q) produced by a pump varies proportionally to the impeller speed (n), the pump head (H) varies proportionally to the square of the impeller speed, and the power consumed by the pump (P) varies proportionally to the cube of the impeller speed. These laws are based on assumptions of constant machine efficiency at the two operating points, and low static system pressure. The laws are summarized in Figure. Q Q 1 n = n 1 H H 1 n = n 1 P1 P n = n 1 3 Q: Flow; H: Pressure (Head); P: Power, n: pump speed Figure. Affinity Laws If an ideal pump is operated at 5% of its rated speed, these laws indicate that its flow rate, head, and power consumption would be reduced to 5%, 6.5%, and 1.56%, respectively. This relationship was verified at site under mill operating conditions for the Descale Pumps. Power and Pressure vs Speed 500 30 000 5 Power (kw) 1500 1000 0 15 10 Pressure (MPa) Power Pressure 500 5 0 5 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Speed (%) 0 Figure 3. Measured Pump Pressure and Motor Power vs Speed This paper will provide examples of some possible applications of variable speed drives for energy conservation, and evaluate the effectiveness of each application. Applications Descaling Pumps: UPGRADE OVERVIEW Due to the fact that the main descaling pumps are alternated on a regular basis, critical for mill production, and large consumers of electrical energy, Tosçelik installed two medium voltage drives, one for each Descale pump. When the mill tracking system indicates that a bar is approaching a descale zone and descaling is required, the running pump is accelerated to operational speed.

Total number New Variable Rating [kw] Table I. Descale Pump System data Qty. of pumps running Method of automatic operation during normal operation 800 1 Mill Tracking control of speed with 3 speed setpoints Energy savings per day [kw-h] ~0000 Pump at Low Idle speed of 700rpm, Pump at High Idle speed of 00rpm, Pump at High Speed of 900rpm, - when not descaling and long delay anticipated. - when not descaling and short delay anticipated. - when metal is in the Descale zones (Furnace, RM or FM), and stays at high speed until the Descale accumulator is recharged. The original system operated one pump continuously to meet the pressure and flow requirements for descaling. Because the sprays are used intermittently and the motors are quite large, the Descale system was a prime candidate for the application of a VFD. TMEIC implemented an optimized control scheme incorporating variable speed operation based on actual Descale requirements, which does not adversely affect strip quality, but greatly reduces the energy consumption of these large motors by reducing the motor speed whenever descaling sprays are not required for the rolling process. Descale Booster Pumps: The Descale Booster system draws water from the DC Tank to provide a pressurized header for the suction of the main Descale pumps and supply cooling water to mill roller tables and other consumers. A pressure regulating valve at the pump discharge header maintained the correct header pressure, opening to relieve high pressure and allowing water to return to the DC tank. The original system operated one booster pump continuously to meet the system requirements. Total number New Variable Table II. Descale Booster Pump System data Rating Qty. of pumps running Method of automatic operation [kw] during normal operation 1 630 1 Proportional Pressure Control from setpoint 0.65 mpa Energy savings per day [kw-h] ~9000 The mechanical pressure regulator in the Descaling booster discharge header ensures that the system pressure is maintained between 6-8 bar. TMEIC implemented an improved control system which monitors the pressure of the discharge header and varies the motor speed to regulate pressure in the header to meet the system needs without excess water being redirected back to the DC tank. PLC Code Actuator Plant P s P PI Flow Controller n Medium Voltage Drive ~ F t Descale System P s Pressure Select smaller value DC System P s Pressure sensor Pressure sensor Figure 4. Descale Booster Pump Control Logic

Roll Cooling Pumps: This system draws cooling water from the DC Tank and supplies the cooling water into the roll cooling header of the FM. The original system operated two of these pumps continuously to provide the required pressure and flow, and Tosçelik was able to turn the flow on or off for each mill stand. Total number New Variable Table III. Roll Cooling Pumps System data Rating Qty. of pumps running Method of automatic operation [kw] during normal operation 4 630 Proportional Pressure Control from F1 and F7 pressure Energy savings per day [kw-h] ~6000 The new control algorithm was implemented similar to the one used for the descale booster, proportional integral pressure control. Further energy savings were achieved by lowering the motor speed when there is less water demand. Laminar Cooling Pumps: The Laminar Cooling pump system draws cooling water from the Laminar Cooling tank and fills the two elevated laminar tube tanks alongside the mill Runout Table (ROT). The original system operated one or two pumps continuously, depending on the mill production rate, with excess water flowing back to the WTP via an overflow path. Total number New Variable Rating [kw] Table IV. Laminar Pumps System data Qty. of pumps running Method of automatic during normal operation operation 3 1 355 1 Mill Tracking control of speed with 3 speed setpoints Energy savings per day [kw-h] ~3600 Pump Stopped, Pump at Idle speed of 660rpm, Pump at High Speed of 00rpm, - a mill long delay signal from existing tracking PLC. - no metal in FM1 & no metal ROT & Laminar Cooling valve close and safety margin met. - FM1 detects material or Laminar cooling valves open, or Laminar Tank level low (below 75mm set, 1300mm reset). The high speed value is set such that the laminar tank level will stay roughly fixed. A strict criteria to prevent laminar tank overflow. The pumps are now running at 74-75% speed (instead of 100% in the old system) when the high speed setpoint is required. Thus the system now saves energy during high speed operation as well as at idle speed. Figure 5. Laminar Cooling Pump Control Logic

Runout Roller Table Cooling Pumps: The Runout Roller Table Cooling system provides cooling water to cool the rolls of the ROT. This system draws cooling water from the Laminar Cooling Tank and supplies the cooling water into the rolls of the runout table. The original control system operated one pump continuously, regardless of the need for cooling the runout table rolls. Total number Table V. Runout Roller Table Cooling Pumps System data Rating Qty. of pumps running Method of automatic [kw] during normal operation operation Mill Tracking control of speed with 3 speed setpoints New Variable 0 1 running with 1 pump in standby mode Energy savings per day [kw-h] ~00 Pump Stopped, Pump at Idle speed of 550rpm, Pump at High Speed of 1485rpm, - a mill long delay signal from existing tracking PLC. - no metal in FM1 & Laminar Cooling valve close and safety margin met. - FM1 detects material or Laminar cooling valves open. The timing diagram is similar to figure 5. above Runout Roller Table Side Spraying Pumps: The Runout Roller Table Side Spraying Pump system is used to deliver cooling water across the direction of strip travel on the ROT to prevent water from accumulating on the strip. The system draws cooling water from the Laminar Cooling Tank and directs a spray of water across the strip. The original control system operated one pump continuously, regardless of the presence of strip on the ROT. Total number Table VI. New Variable Rating [kw] 160 1 running with 1 pump in standby mode Runout Roller Table Side Spraying Pumps System data Qty. of pumps running Method of automatic operation during normal operation Mill Tracking control of speed with 3 speed setpoints Energy savings per day [kw-h] ~1300 Pump Stopped, Pump at Idle speed of 950rpm, Pump at High Speed of 980rpm, - a mill long delay signal from existing tracking PLC. - no metal in FM1 & no metal ROT & Laminar Cooling valve close and safety margin met. - FM1 detects material or Laminar cooling valves open. In the old system, the pumps ran at 100% speed all the time. At 100% speed, the drive consumed 101kW. Now at idle speed the power consumption is 4.4kW. The timing diagram is similar to figure 5. above. Scale Pit to Sedimentation Tank Pumps: The Scale Pit to Sedimentation Tank Pumps extract strip contact cooling water from the Scale Pit after the large solids have settled out of the solution and delivers this water to the Sedimentation Tank. The existing control system used a simple hysteresis control scheme to regulate water level in the tanks. Total number New Variable Table VII. Rating [kw] 4 3 315 or 3 to meet flow demand Scale Pit to Sedimentation tank Pumps System data Qty. of pumps Method of automatic operation running during normal operation Proportional Scale Pit and Sed. Tank Level compensation added in to flow ref in to DC tank to give a speed reference Energy savings per day [kw-h] ~301 Proportional Level control was implemented for the Sedimentation Tank. This Sedimentation Tank level compensation (regulator output) is added to the Flow going out of the Sedimentation Tank to give the flow reference.

F d L ST n ~ F t L ST Figure 6. Scale Pit Pumps Control Logic The pressure loss due to tank elevation restricts the available speed range for the variable speed drives to approximately 55% of the motor rated speed. Sedimentation Tank to Direct Cooling Tank Pumps: This system draws cooling water from the Sedimentation Tank after it has been sufficiently clarified and it delivers the water to the DC Tank, where water is circulated in the tower to be cooled by evaporation and is available for re-use. The existing control system used a simple hysteresis control scheme to regulate water level in the tanks. Table VIII. Sedimentation tank to Direct Cooling Pumps System data Total number New Variable Rating [kw] Qty. of pumps running during normal operation Method of automatic operation 4 315 Proportional DC Tank Level compensation added in to flow feedback from consumers to calculate a speed reference Energy savings per day [kw-h] ~300 The pressure loss due to tank elevation restricts the available speed range for the variable speed drives to approximately 55% of the motor rated speed. Proportional Level control was implemented for the DC Tank. This DC Tank level compensation (regulator output) is added to the speed reference calculated based on the measured Flow going out of the DC Tank (to different consumers such as Descale Booster, Roll Cooling Pumps and other users) to produce the drives speed reference. F d L DC n ~ F t L DC Figure 7. Sedimentation Tank Pumps Control Logic

Drive System The medium voltage drives selected for this project were chosen to minimize the impact on the existing mill and equipment. The voltage source inverter drives are a common design with modular construction for easy maintenance, constructed from many interchangeable modules. Each module contains three phase rectifier diodes, DC link capacitors, and a single phase medium voltage IGBT inverter. Three modules are arranged to produce a three phase output, and the modules are connected in series to provide the necessary output voltage. The composition of the modules and combination required for this application is shown in Figure 8. Main Power 6kV / 6.6kV 36 Pulse Cell Inverter Module View M ~ 5 PWM Level Sinusoidal Output Motor 6kV / 6.6kV Figure 8. Medium Voltage Drive Topology Figure 9. Medium Voltage Drive

Such modular construction results in a multi level output where the number of levels increases with the output voltage, providing a very smooth output waveform that is compatible with existing fixed speed motor designs. The drive is air cooled, which eliminates the need for a separate water system to cool the drive. The drives are constructed to require only front access for maintenance, so they may be installed in back to back lineups or against a wall. The 6kV class of these drives features a 36 pulse diode converter, which maintains much higher power factor across all loading conditions than the existing motors, which were applied directly from the AC power bus. Additionally, the 36-pulse diode converter produces low harmonics which comply with the limitations of IEEE 519. The 5 level output from the 6kV AC inverter produces a virtually sinusoidal waveform that is compatible with the existing motor design without the need for additional filters. Figure 10. Medium Voltage Inverter Output Voltage and Current waveforms Existing Motors The existing motors were originally designed for fixed speed operation from the utility source with low harmonics, and relatively constant voltage and frequency. To prevent any harmful effects caused by the application of a new variable voltage and variable frequency power supply, Tosçelik has plans to install grounding brushes for each motor. These grounding brushes should prevent bearing damage caused by the flow of current from the motor shaft to ground. Speed sensors were not installed on the original motors and were deemed unnecessary because the new variable frequency drives use a sensor-less control algorithm and the actual operating speed of the motors was not deemed critical to the system performance.

PROJECT RESULTS Table IX. Typical energy saving data Energy Saved / day Total Energy Consumed Savings Percent Savings kw-h/day kw-h/day kw-h / ton Descale 1940 30435 6.44 38.95% Runout Roller Table 90 653 0.30 57.98% Side Spray 14 860 0.37 56.44% Laminar Cooling 3144 169 1.04 65.87% Scale Pit 13 75 0.70.01% Sedimentation Tank 3149 714 1.04 30.60% Roll Cooling 6685 18579. 6.46% Descale Booster 7785 4309.58 64.37% Note 1: Data taken from October 1 st until October 31 st 0. Note : above data based on an average of 3015 Tons rolled per day. The energy saving results are presented to the operators via HMI screen. Figure. Energy Saving Overview HMI screen The Actual Idle Power was calculated in the PLC based on drive power feedback, and includes the power during deceleration from High Speed to Idle Speed, during which time the drive still takes some power.

Figure 1, below, is a graph showing the Energy savings in kw-h for each of the systems. kw-h Energy Saved Per System, Per Day 60,000 50,000 kw-h Energy Saved or Tons Rolled 40,000 30,000 0,000 Descale Descale Booster Roll Cooling Laminar Cooling Sedimentation Tank Scale Pit Side Spray Runout Roller Table Tonnage Rolled 10,000 0 7-Sep- 14-Sep- 1-Sep- 8-Sep- 5-Oct- 1-Oct- Days 19-Oct- 6-Oct- -Nov- Figure 1. Energy Savings in kw-h for each system and Tons Rolled vs Time Charts showing the energy usage before and after the Energy Saving System installation. Figures 13 and 14 below show the Water Treatment monthly energy usage (bars), relative to the monthly tonnage shown as a line. Figure 13. Water Treatment Energy Usage kwh/ton - (switchover to new system at the beginning of September)

Figure 14. Descale Pump Energy Usage kwh/ton (switchover to new system at the beginning of August) Data for Figures 13~15 supplied from Tosçelik reports. Figure 15. Energy usage for Hot Strip Mill SUMMARY TMEIC achieved the goals set out in this energy saving project. Obviously the energy savings will vary, with high savings during rolling days with delays, and lower savings during high production. However, based on energy saving data taken per shift over a period of 0 days, we can summarize below. Based on an Energy unit cost of $0.10/kW-h Energy savings per day Energy savings per ton typically 45,000 kw-h typically 14 kw-h Energy savings per day typically $4,500 The energy savings for different energy costs can easily be extrapolated. In this case, the payback on the energy saving project investment was less than years. The payback calculations include the cost of the equipment, an additional standby descale drive, spare parts and installation. The results are shown in figure. Although the Sedimentation Tank and Scale Pit systems are showing a much longer payback period, the customer has reported an important reduction in maintenance cost of these systems mainly because with the drives, the pumps are not subject to the start and stop sequences of the original hysteresis control.

100.0 80.0 Months 60.0 40.0 0.0 0.0 Total Descale Descale Booster Side Spray Runout Table Laminar Cooling Roll Cooling Sedimentation Tank Scale Pit System Figure 16. Payback time for each system Other advantages 1. Less manual intervention by the operators in the control of the Water Treatment plant. Less stress on the motors, pumps, valves and pipes due to reduced hydraulic impact, resulting in less maintenance requirements, reduction in replacement parts, and extended equipment life time. 3. Less water circulation reducing the need for water treatment and make-up water. 4. Before the VFD installation, sometimes descale pump trips were experienced during start-up following a long maintenance shutdown due to sudden pressure changes. This was eliminated after the installation of VFD by starting up in energy saving mode and pre-filling the line smoothly at slower speed. 5. The new drives rode through the power dips that tripped the existing non-tmeic mill drives 6. Installation of the energy saving equipment did not impact production Extensive pre-switchover testing in TMEIC systems test facility and at site. Fast new system tune-up Non-drive pumps were used for production during drives commissioning and uncoupled testing at site 7. Failure scenarios were factored in to the energy saving system design, to eliminate the potential for mill disruption from the new energy saving system. a) HMI failure Operator can run the system from existing mill HMI or local desk. b) Drive Failure - The control system includes the ability to operate variable speed pumps in parallel with the remaining fixed speed pump in the system. 8. Reduction of the kvar demand due to the close to unity power factor of the drives front end. REFERENCES 1. I. Karassik, J. Messina, P. Cooper, C. Heald. Centrifugal Pumps, Pump Handbook, McGraw-Hill Co., New York, NY, 008.