TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System

Similar documents
Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Design, Development and Experimental Investigation of Volumetric Air Receiver

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

STUDY, ANALYSIS AND DESIGN OF AUTOMOBILE RADIATOR (HEAT EXCHANGER) PROPOSED WITH CAD DRAWINGS AND GEOMETRICAL MODEL OF THE FAN

Water Cooled Condenser Using Nano Fluids

Falling Film Heat Exchangers for Solar Water Heaters

Modified Air Cooler with Split Cooling Unit

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Experimental Studies on Aero Profile Thermosyphon Solar Water Heating System

Solar air heater duct having triangular protrusions As roughness elements on absorber plate

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

CHAPTER 7 COMPARISON OF HEAT EXCHANGERS

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

DESIGN AND MANUFACTURING OF CHEMICAL AGITATOR

Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2

EFFECTIVE UTILIZATION OF SOLAR ENERGY IN AIR DRYER

ICSV14. Cairns Australia 9-12 July, Noise reduction of handheld vacuum cleaners according to geometric optimization of air passages

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array

A REVIEW ON HEAT TRANSFER ENHANCEMENT BY PASSIVE METHODS

Fin-Fan Control System

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Experimentation of Heat Pipe Used In Nano-Fluids

Effect of Flow Distortion in Inlet Duct on the Performance of Centrifugal Blower

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

TRANSACTIONS ON ADVANCEMENTS IN SCIENCE AND TECHNOLOGY (TASTONLINE)

Performance Study of Triple Concentric Pipe Heat Exchanger

Experimental analysis of condensation heat transfer enhancement of steam at low pressures using modified twisted tape insert

Global Journal of Engineering Science and Research Management

Cabinet Type Washing and Drying Machine

Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography

Natural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review

Performance Optimization of the Evaporative Condenser Design

Chapter 1. Introduction, Literature Review and Need of Study

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS

THERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments.

ISSN (Online)

[Eswaran, 3(3): March, 2014] ISSN: Impact Factor: 1.852

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

2. HEAT EXCHANGERS MESA

Compression of Fins pipe and simple Heat pipe Using CFD

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

Analysis of Centrifugal Pump with Closed Type Impeller for Slurry Operations

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE

Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger

PASSIVE CONTAINMENT COOLING: MODEL EXPERIMENTS

Solar Drying Techniques And Performance Analysis: A Review

Enhancement of COP in Vapour Compression Refrigeration System

EXPERIMENTAL INVESTIGATION OF VAPOUR ABSORPTION SYSTEM

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal Blower Nitin S. Jadhav *, S. R. Patil

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Effect of Inclination Angle on Temperature Characteristics of Water in- Glass Evacuated Tubes

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

Design and Experimental Analysis of Concentric Tube Heat Exchangers with Various Fins

Adsorption refrigeration system using waste heat

Effects of mass flow rate in terms of pressure drop and heat transfer characteristics

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

FLIGHT UNLOADING IN ROTARY SUGAR DRYERS. P.F. BRITTON, P.A. SCHNEIDER and M.E. SHEEHAN. James Cook University

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

THERMOHYDRAULIC PERFORMANCE OF AN EQUILATERAL TRIANGULAR DUCT WITH ARTIFICIAL ROUGHNESS USED IN SOLAR AIR HEATER

FLOW AND PERFORMANCE INVESTIGATIONS OF CENTRIFUGAL BLOWERS WITH AEROFOIL BLADED IMPELLERS

Sant Gadge Baba Amravati University. Amravati, Maharashtra, India, Maharashtra 2


Heat Exchanger Joule-Thomson Transient Cryogenic Refrigeration. Iranian Journal of Chemical Engineering Vol. 14, No. 3 (Summer 2017), IAChE

Mechanical Engineering Department Sheet (1)

Development of Large Size Hybrid Fan

Finite Element Analysis, Harmonic Analysis and Modal Analysis of the Car Floor by Using With and Without Stiffener

Performance Analysis of a Thin Tube Water Heater for Egerton University Using Comsol

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

a Heat Exchanger using FEA Tool

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect

Transcription:

TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System Prof. G.L.Allampallewar 1, Divyal P. Bagul 2, Abhiraj S. Galande 3, Amol M. Rathod 4, Ketan R. Behere 5. 1 Assistant Professor,MarathwadaMitra Mandal s Institute of Technology,Pune, girish.all@gmail.com 2 Student,MarathwadaMitra Mandal s Institute of Technology,Pune, divyalbagul@gmail.com 3 Student, MarathwadaMitra Mandal s Institute of Technology,Pune, abhirajgalande@gmail.com 4 Student, MarathwadaMitra Mandal s Institute of Technology,Pune, amol15rathod1995@gmail.com 5 Student.MarathwadaMitra Mandal s Institute of Technology,Pune,ketanbehere555@gmail.com ABSTRACT This presented research presents the design and development of a fanned radiator system in order to increase the heat transfer rate and to make the radiator system dynamically stable (like reduction of vibrations in fan module) as compared to existing simple, geometrically same fan and simple radiator having same area of heat transfer.the experiments were conducted on a test set up which is fabricated and mounted on a steel pipe structure. Three modifications are done on the existing simple fanned radiator systems which include, 1) Use of louvered fins. 2) Use of nano particles(tio2) in the fluid being used. 3)Shrouding of the fan 4) Cutting profiles on a fan blade leading edge using the biomimicry of whale tubercles.the analysis of the designed components were done using solidworks software as a tool. The experiments were carried using temperature sensors, water pump, and in similar ambient conditions. The simulation of fan was done usingsolidworks. Various parameters were considered in the experiment in order to validate the design and to achieve the required results like temperature difference, time required for the fluid (at particular fluid flow rate) to gain the ambient temperature, amplitude of vibrations induced in the system due to fan. The results show that the heat transfer rate increased tremendously. Also the vibration amplitude of the system was reduced. It is found that the improvement in performance of radiator gets highly affected by the turbulence created in the radiator fins so that for the same capacity of radiator we can design a relatively low surface area radiator and it will reduce material cost, size of radiator and hence it will occupy less space. The shrouding and bio mimic shape of fan blades helped to reduce vibrations and drag force hence helping to increase efficiency of the fan. Keywords: louvered fins, shroud,biomimicry, tubercles, nanoparticles, (TiO2) etc. ----------------------------------------------------------------------------------------------------------------------------- 1. INTRODUCTION: Radiators are used to transfer thermal energy from one medium to another for the purpose of cooling. Research is being carried out for several decades now, in improving the performance of the radiators, which are very compact and can be used in automobile industry. Also the research is going on in order to reduce the noise and overall cost of the radiators with increase in heat transfer rate. These compact radiators have fins, louvers and tubes. The experimental setup through which we have obtained increase in heat transfer rate of radiator consist the following things: i. Radiator with louvered fins ii. Coolant Reservoir iii. Shrouded fan having biomimicry shaped blades iv. Nano-particles v. Pump vi. Motor vii. Water based Glycol 1213

1.1 Radiator with louvered fins : Radiator are also called as heat exchanger with the purpose of takeout heat from source[4]. Here heat is transmitting through coolant liquid medium to atmosphere. It consists of core, top and bottom tank. Core is designed with two sets of passageway, one set of tube as well as fin. Liquid coolant flows inside the fins as soon as air gets flow its outer surfaces. The heat presents in the fluid which is supplied via. Source is absorbed by the coolant. The nanoparticles present in the coolant increases the heat carrying capacity of the fluid and further it is carried via radiator then exchange it with atmosphere with help of fan. Whereas, the radiator which we have used for the experiment have louvered fins. The purpose behind using the louvered fin is to break the boundary layer which causes the flow become turbulent that results into increase in convective heat transfer coefficient i.e. h. 1.2 Shrouded fan: The axial flow fan is extensively used in many engineering applications. The axial fans are very adaptable and that is why they are extensively used in the industry for the cooling purpose and moving the toxic gases in the petrochemical industry. The need of using compact fans in the automobile industry is because of the increasing demand for the low degree of compactness and low weight systems. The extended use of axial flow fans for fluid movement and heat transfer has resulted in detailed research into the performance attributes of many designs. In case of the fan that we have used and designed for this experiment have a tip to tip connected shroud which makes the fan blades stiffer and tip vibrations are reduces significantly. That results reduce in the noise of the fan. 1.3 Nano Particles : Nano fluids is a fluid having non sized solid particles, normally particle size less than 100 nm, disperse in the convectional based fluid water, mineral oil, ethylene glycol. This tremendously enhance the heat transfer characteristics (and little penalty in pressure drop) of original fluid. The advanced technology nowadays is having great potential to increase the thermal properties of fluids being used in the radiators. The nano-particles which we have used in this experiment is TiO 2. The reason behind using the nano-particles is to get higher heat transfer rate. 2. Design and Analysis: The assembly components which are designed for the betterment of results are as follows: i. Louvered fins ii. iii. Shrouded fan Hub of fan 2.1 louvered finsgeometry: The following table and fig. gives an idea about the louvers which are used for optimized results: Number Fin Pitch F p (mm) Louver Pitch L p (mm) Louver angle L a (degree) Tube Pitch T p (mm) Table-1: Details about the Louvered fins Number of tubes n Hydraulic diameter d h 1 2.02 1.4 22 o 11 32 3.35 (mm) 1214

Fig-1: Fin Terminology 2.2 Shrouded Fan: Fig-2: CAD model of Louvers Following factors are considered while designing the shrouded fan: 1. Air flow volume should be higher 2. The noise level must be reduced. Fig-3: CAD Model of shrouded Fan 1215

Sr. Parameter Value No. 1 Minimum Dia. Of Hub 0.15 m 2 Min. dia. Of Wheel 0.30 m 3 Hub Tip Ratio 1:2 4 No. Blades 6 5 Blades Spacing 0.1570 m 6 Tip Speed 267.0353 rpm Table-2: Details of shrouded fan 2.2.2 Flow simulation of fan : Air velocity range obtained at radiator position between the range of 39 to 58 m/s Fig-4: Velocity Distribution Fig-5: Pressure Distribution 1216

3. Experimental study: 3.1: Experimental setup: The given below image is actual experimental setup which was used. The setup has a pump for pumping the fluid, a reservoir that contain fluid. Two temperature sensors were used for taking readings of temperature instantaneously. 3.2: Procedure: The experiment was conducted firstly using simple fin and simple fan and readings were taken for the temperature after every 1 minute for the same ambient conditions. Then the same procedure was carried out by using louvered fin radiator and modified fan and corresponding readings were taken. Also for vibration measurement, a accelerometer is placed on the structure at same place and readings are taken for both cases. Sr. No. Parameter Value 1 Ambient 35 0 C temperature 2 Amount of fluid 10 litres 3 Initial temperature 4 Amount of TiO 2 added 44 0 C 20 gms Fig-6: Actual experiment setup Table-3 4. Results: Given below fig-7 is the graph of temperature Vs time in minutes for both the radiators. Where red colour indicates the graph of simple radiator and purple colour indicates graph of modified radiator system. Also fig- 8, 9 are the results of vibrations for the simple and modified fan. Fig-7: Comparison of both radiator systems 1217

4.1 Result Based on Graph: Unit less numbers used depending upon the medium of fluid are as follows: 1. Reynold s number: Re = ρ V L γ 2. Prandtl number = 0.7 3. Nusselt s number = 0.036*Re 0.8 *Pr 0.33 4. Nusselt number= Nu = h L K 5. Thermal Conductivity of aluminium i.e. K aluminium = 237 W/mk 6. Total Area of Heat Transfer = 0.078 m 2 7. Time for which the fluid was circulated= 14 min. Sr. No. Radiator which is used Convective heat transfer coefficient (W/m 2 K) Heat Transfer Rate (kw) % increase 1 Simple Radiator 964*10 3 413.55 kw 63.63 % 2 Modified Radiator 964*10 3 676.728 kw Table-4: Comparison of heat transfer rates Fig-8: Vibrations due to modified fan. Fig-9: Vibrations due to simple fan. From above graphs of acceleration Vs time, it is observed that for simple fan, the acceleration in Z direction is between 5-10 m/s 2. And for modified fan, the acceleration is between 0-1 m/s 2. Which is a drastic change. 1218

5. CONCLUSION From the above results obtained, we can conclude that the addition of TiO 2 nanoparticles increases the coefficient of thermal conduction and use of louvered fins at an angle of 22 0 breaks the boundary layer and makes the flow turbulent hence increases coefficient of convection heat transfer as compared to simple fins which results in streamlined flow. The use of louvered fins and addition of nanoparticles increases rate of heat transfer by 63%. Which means we can design radiator of same heat transfer capacity having a low area, which results in a compact, low weight, low cost radiator unit for same function. Also the modifications done in the fan results decrease in vibrations. The acceleration decreased by 92%. It means that the vibrations are reduced by significant amount. The area of tip of blade which vibrates and produces maximum vibrations are reduced by providing a shroud connected tip to tip and makes the system more stable. ACKNOWLEDGEMENT The authors are thankful to the ARAI for providing access to useful research papers for the study of radiator systems. We would like to thank our guide, Prof. G.L. Allampallewar for his valuable guidance in the subject.also we would like to thank Prof. D.M. Bhoge for his guidance and suggestions in the vibrations analysis. REFERENCES [1] D Govindaraj, Effective selection methodology for a louvered fin heat exchanger using thermal resistance and number of transfer units method, SAE India, 2011. [2] L. K. Goldenstein, D.W. Radford And P.A. Fitzhorn, The Effect Of Nanoparticle Additions On The Heat Capacity Of Common Coolants, SAE, 2002. [3] Hidetake Ota, Katayama Yuichi, Yokoyama Hiroshi and Osawa Yukio, Development of High Efficient Radiator Cooling Fan for Automotive Application, SAE, 2013. [4] Gifford N. L., Hunt A. G., Savory E., Martinuzzi R. J., Experimental Study of Low-Pressure Automotive Cooling Fan Aerodynamics Under Blocked Conditions, CSME, 2006 [5] Sam Weitzman and Ann Lambert. More Efficient Helicopter Blades Based on Whale Tubercles, Journal of Emerging Investigators, Dec 22, 2013. [6] https://en.wikipedia.org/wiki/radiator. 1219