Signet V(D) to V(D) PVDF Conductivity Electrodes

Similar documents
Signet ph/orp Electrodes

Inductive Conductivity

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

PURSense Sanitary Flange Conductivity Sensors

Condumax CLS16 and CLS16D

CONTACTING CONDUCTIVITY BOILER SENSORS Instruction Manual

Rosemount 372. HF Resistant ph sensor. Quick Start Guide LIQ-QSG-372 Rev. C June 2017

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

Electronic Pressure Digest. Pressure and Temperature Transmitters

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

CLARITY II TURBIDIMETER

Dual Input Toroidal Analyzer

Operating Instructions Indumax CLS54D

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Dual Input ph/conductivity Analyzer

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Brazed Plate Heat Exchanger

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Temperature Sensors & Compression Seal Fittings

Temperature Sensors & Compression Seal Fittings for Semiconductor Processing

Brazed Plate Heat Exchanger

Operating Temperature/Pressure Graphs: Flow Sensors

Figure 1 DirectLine DL423 Sensor. Description, continued

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

86BSD Digital Output

1 of 5. HHM Engineering Sdn. Bhd. Oilfree Piston-Vacuum Pump. S601 Compressed Air Purity Analyser. Advantages

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications

Inductive. Range. S410/IND Electrodeless Conductivity Sensors

Figure 1 DirectLine DL423 Sensor. Description, continued

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

For very low to medium/high conductivity: Where optimal performance is essential. INGOLD Leading Process Analytics

Industrial Strength Leak Detection

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Concise catalogue Water-Industry

Dissolved Oxygen Measurement liquisys M COM 223 / 253

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Durafet Non-Glass ph Electrodes Specifications

Retractable ph/orp Sensor

SITE CONDITIONS Design Altitude < 3,280 Ambient Temperature F Humidity < 80 % Gas and Noxious Vapors

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

86BSD Digital Output

Duct Humidity/Temp Sensor

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

750 Series II CONDUCTIVITY/TDS & RESISTIVITY MONITOR/CONTROLLER Operation Manual

Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus

Quick Reference Guide Barrier Strips

INTRODUCTION / TABLE OF CONTENTS

86BSD Digital Output

Outside Air Humidity & Temperature Sensor

4600 Series Operating Instructions. Models 4623 and 4628 Conductivity Transmitters To Meet United States Pharmacopœia (USP 23) Regulations

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

OPTISENS TUR 2000 Technical Datasheet

Centro-Matic Automated Lubrication Systems System Controls

Flow ph ORP Conductivity Resistivity Temperature Pressure Level. Signet Products Condensed Catalogue

Model 4001 Series Single Channel Controller

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

Instruction Manual April sitrans AS 100

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

User Manual System 11

Cable Actuated Sensor Industrial User Scalable 4 20mA

Process Analytics Catalog

900MAX PORTABLE SAMPLERS

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Dräger Polytron 8700 IR Detection of flammable gases and vapors

MultiFix Central unit

750 Series CONDUCTIVITY/TDS & RESISTIVITY MONITOR/CONTROLLER Operation Manual

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

GATEKEEPER GAS PURIFICATION SYSTEM DX SERIES FOR 20, 30, 50 AND 60 NM 3 /HR

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dual Input ph/orp Analyzer

PRODUCT LINE. Highest Quality, Best Service

Dräger Polytron 8720 IR Detection of carbon dioxide

GAS MONITOR Model Model

Datasheet: K-22 LO Sensor

Rosemount 3051CFC Compact Flowmeter

Electronic Flow Switches

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

OPERATION MANUAL MODEL & ACCELEROMETER

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

Cable Actuated Sensor Industrial User Scalable VDC Output

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Steam and Water Analysers

Dew-Point Transmitters and Instruments

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

Dräger Polytron 5720 IR Toxic Gas Detection

WATER TREATMENT SYSTEM CONDUCTIVITY CONTROLLER With feed verification INSTALLATION & OPERATION MANUAL

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Using the DewTrak II Dew Point/ Humidity Transmitter

HydroFlex 3-in-1 microplate strip washing. Flexible and reliable microplate strip washing and vacuum filtration in a compact, modular platform

Instruction Manual PN pH/rev.M February Model Solu Comp II. Dual Input ph Analyzer. Model Options and

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Toroidal (Electrodeless) Conductivity Sensors Series 5000TC Specifications

Level Measurement Continuous level measurement - Ultrasonic transmitters

254 Nanometer Germicidal UV Disinfection Systems

LAKEWOOD INSTRUMENTS MODEL 353 ORP/MILLIVOLT CONTROLLER

Transcription:

Signet 2839-1V(D) to 2842-1V(D) PVDF Conductivity Electrodes Features ± 2% accuracy - Custom calibration certificate provided Dual-threaded Compact electrode length for easy in-line installation in small pipe sizes Triple orifice flow-through design reduces clogging and bubble entrapment 316 SS electrodes with injection molded PVDF process connections and insulators 2839-1V 2840-1V 2841-1V 2842-1V Meets USP requirements The Signet 2839-1V(D) to 2842-1V(D) Conductivity/ Resistivity Electrodes are available in four cell constants from 0.01 to 10.0 cm -1, and are suitable for a wide variety of applications from high purity water quality monitoring to weak acids and bases. 316 SS electrode surface finishes are controlled in a precision bead blasting operation to ensure measurement accuracy and repeatability. The PVDF insulator and process connections are injection over-molded to minimize variance between electrodes. Double threaded connections in either ¾ in. NPT or ISO 7/1-R 3/4 enable quick and easy installation in submersible or in-line configurations. Transmitter integral mounting kit and junction boxes are available as accessories. Applications Water Treatment & Water Quality Monitoring Reverse Osmosis Deionization Cooling Tower and Boiler Protection Distillation Desalination Demineralizer Semiconductor Aquatic Animal Life Support Systems A Certificate of Calibration is included with all 2839-1V(D) to 2842-1V(D) Conductivity/Resistivity Electrodes. The electrodes are calibrated to meet ± 2% accuracy. Electrodes can be shipped back to the GF Signet factory for recertification. The certificate includes calculated cell constant and temperature offset which when entered into the "custom cell" menu of any Signet meter would provide a 2% accuracy of the sensors reading.

Specifications General Operating Range 2839 0.055 to 100 μs 0.02 to 50 ppm 18.2 MΩ to 10 KΩ 2840 1 to 1,000 μs 0.5 to 500 ppm 1 MΩ to 1 KΩ 2841 10 to 10,000 μs 5 to 5,000 ppm 2842 100 to 200,000 μs 50 to 100,000 ppm Cell Constant Accuracy ±2% when the information provided on the certificate of calibration is entered into the transmitter/meter or when wet calibrated with a traceable standard. Dual-Threaded Process Connection -1V versions: ¾ in. NPT -1VD versions: ISO 7/1-R 3/4 Cable Length standard 4.6 m (15 ft) (use for the maximum 30 m (100 ft) all sensors when used with the 9900 2839, 40,41 0.01 cells 4.6 m (15 ft) used with 8850, 8860, and 2850* and 42) Temperature Element PT1000 Temp. Response, t 0.01 cell 5 sec. 0.10 cell 10 sec. 1.0 cell 20 sec. 10.0 cell 30 sec. Temperature Accuracy ±0.5 C ±0.9 F Wetted Materials Internal O-ring (2841 and 2842) FKM Insulator Material PVDF Electrode Material 316 SS Threaded Process Connection PVDF Max. Temperature/Pressure Rating 131 C @ 2.76 bar 268 F @ 40 psi Storage Temperature -20 C to 131 C -4 F to 268 F Shipping Weight 2839 0.34 kg 0.74 lb 2840, 2841, 2842 0.30 kg 0.66 lb Standards and Approvals RoHS compliant, China RoHS Manufactured under ISO 9001 for Quality and ISO 14001 for Environmental Management and OHSAS 18001 for Occupational Health and Safety *2850 cable length 4.6 m (15 ft) maximum for all cells. See Temperature and Pressure graphs for more information.

Dimensions Dual-Threaded Electrodes 3-2839-1V(D) (0.01 cell) 4.6 m/15ft 3-2840-1V(D) (0.1 cell) 4.6 m/15 ft 140.7 mm (5.54 in.) Dual threads 3/4 NPT or ISO 7/1-R 3/4 front and back 103 mm (4.05 in.) 59.3 mm (2.33 in.) 73 mm (2.88 in.) 21.5 mm (0.85 in.) 35 mm (1.38 in.) 3-2841-1V(D) (1.0 cell)* 4.6 m/15 ft 3-2842-1V(D) (10.0 cell)* 4.6 m/15 ft * Although these electrodes look similar in design, there is an inherent difference. From the bottom view, the 2841 electrode features a simple plastic insert. However, the 2842 electrode features a complex plastic insert with four holes through which liquid flows. 109 mm (4.3 in.) Dual threads 3/4 NPT or ISO 7/1-R 3/4 front and back 109 mm (4.3 in.) 26.8 mm (1.13 in.) 41.3 mm (1.63 in.) 26.8 mm (1.13 in.) 41.3 mm (1.63 in.) Integral Mount Sensor The 2839-2842 Dual Threaded Conductivity Electrodes can be directly mounted to a 3-8850-3 transmitter, using the 8052 Integral Mount Kit. Customer to modify the cable length of the standard cable assembly. See sensor manual for details. The 2839-2842 Dual Threaded Conductivity Electrodes can be directly mounted to a 3-9900-1 transmitter, 3-9900.396 direct conductivity module, 3-9900.396 angle adjust adapter and the 8052 Integral Mount Kit. Customer to modify the cable length of the standard cable assembly. See sensor manual for details.

ENTER Profibus Address Power 24 VDC 0.40A Max L IN 5V OUT PWR PWR PWR Profibus Address Power 24 VDC 0.40A Max L IN 5V OUT PWR PWR PWR USB USB Signet 3-0486 Profibus Concentrator Channel 1 5V OUT Signet 3-0486 Profibus Concentrator Channel 1 5V OUT L IN L OUT L OUT- Out In Channel 7 Valve Channel 2 S 3 L Freq 5V OUT L IN L OUT L OUT- Out In Channel 7 Valve L IN 5V OUT Channel 2 S 3 L Freq 5V OUT Channel 6 Channel 3 5V OUT L IN 5V OUT Channel 6 Channel 3 5V OUT Channel 5 Channel 4 5V OUT Channel 5 Channel 4 5V OUT Panel Mount Signet Instruments 8850 8860 8900 with 2850 Sensor Electronics 9900 with 3-9900.394 Direct Conductivity/Resistivity Module or 2850 Sensor Electronics OR OR Pipe, Tank, Wall Mount In-Line Installation Field (Integral) Mount Signet Instrument Signet Instrument 8850 with 3-8050 Universal Mount Kit 8850 with 3-8052 Integral Mount Kit 9900 with 3-9900.394 Direct Conductivity/Resistivity 9900 with 3-9900.394 Direct Module or 2850 Sensor Electronics and Rear Enclosure Conductivity/Resistivity Module and Rear Enclosure OR 4 to 20 ma Output Automation System Signet 2850 Sensor Electronics 2850 Sensor Electronics with 0486 Profibus with a customer supplied Concentrator and Customer Supplied Programmable Logic Controller or Programmable Logic Controller or Programmable Automation Controller Programmable Automation Controller PLC PLC System Overview Signet 2839-2842 Conductivity Electrodes Customer Supplied Fittings, 3/4 in. NPT or ISO threaded Pipe, Tank, Wall Mount Signet Instruments 8850 8860 8900 with 2850 Sensor Electronics 9900 with 3-9900.394 Direct Conductivity/Resistivity Module and Rear Enclosure or 2850 Sensor Electronics with Angle Adapter OR ENTER OR Submersible Installation and customer supplied pipe extension or conduit with 3/4 in. FNPT threads* Field (Integral) Mount Signet Instrument 8850 with 3-8052 Integral Mount Kit 9900 with 3-9900.394 Direct Conductivity/Resistivity Module and Angle Adapter Automation System 2850 Sensor Electronics with 0486 Profibus Concentrator and Customer Supplied Programmable Logic Controller or Programmable Automation Controller All sold separately PLC Signet 2839-2842 Conductivity Electrodes *Refer to the Signet Submersion Kit brochure (3-0000-707) located on our website for installation suggestions and options. All sold separately Operating Range Chart UPW @ 25 C USP Bottled Water Cooling Tower Waste Waters Deionization Regen. Chemicals Alkali Cleaners, Acids/Bases Rinse Water 3-2842 Brackish Sea Water (Salinity) (10.0 Cell) 3-2841 (1.0 Cell) 3-2840 (0.10 Cell) 3-2839 (0.01 Cell) 0.055μS 1μS 10μS 100μS 1,000μS 10,000μS 100,000μS 18.2MΩ 1MΩ 100KΩ 10KΩ 50,000μS 200,000μS 400,000μS PPM TDS 5 50 500 5,000 25,000 50,000 100,000 200,000

Temperature/Pressure Graphs Note: The pressure/temperature graphs are specifically for the Signet sensor. During system design the specifications of all components must be considered. In the case of a metal piping system, the PVDF process connector provided with the sensor may reduce the overall system working pressure. (psi) 150 125 100 75 (bar) 10.3 8.6 6.9 5.2 50 3.4 25 1.7 0 C -40-20 0 20 40 60 80 100 120 F -40-4 32 68 104 140 176 212 248 140 284 Application Tips Use 2839 series electrodes with the 3-2850-63 electronics and 8900 for applications requiring multiple measuring points. Liquid levels must be high enough to cover vent hole on sensor body. Install sensors in an area that will remain free of air bubbles and sediment build-up. Conductivity measurements are affected if electrodes are coated by process substances. Use Model 2839 with the 2850/8900 for low conductivity applications requiring multiple measuring points. Ordering Notes 1) The Conductivity Certification tools are compatible with the following Signet Instruments: 8900, 9900. 2) The sensor cable can be extended up to 30 m (100 ft). See restrictions under general specifications. Example of NIST Traceability Certificate Please refer to Wiring, Installation, and Accessories sections for more information.

Ordering Information Sensors for use with 9900, 2850, and 8860 Instruments Mfr. Part No. Code Cell Constant Connection Thread Size(s) Cable Length 3-2839-1V 159 001 810 0.01 cm-1 Dual threaded ¾ inch NPT 4.6 m (15 ft) 3-2839-1VD 159 001 811 0.01 cm-1 Dual threaded ISO 7/1-R 3/4 4.6 m (15 ft) 3-2840-1V 159 001 812 0.1 cm-1 Dual threaded ¾ inch NPT 4.6 m (15 ft) 3-2840-1VD 159 001 813 0.1 cm-1 Dual threaded ISO 7/1-R 3/4 4.6 m (15 ft) 3-2841-1V 159 001 814 1.0 cm-1 Dual threaded ¾ inch NPT 4.6 m (15 ft) 3-2841-1VD 159 001 815 1.0 cm-1 Dual threaded ISO 7/1-R 3/4 4.6 m (15 ft) 3-2842-1V 159 001 816 10 cm-1 Dual threaded ¾ inch NPT 4.6 m (15 ft) 3-2842-1VD 159 001 817 10 cm-1 Dual threaded ISO 7/1-R 3/4 4.6 m (15 ft) Special Order Options - Please consult the factory Cable length extensions of up to 30 m (100 ft) are available. For resistivity measurements above 10 MΩ when used with the 8850-3 or the 8860 cable lengths of the sensor should not exceed 4.6 m (15 ft). Accessories and Replacement Parts Mfr. Part No. Code Description 3-2850.101-1 159 001 392 Plug-in NIST traceable recertification tool, 1.0 μs simulated, 3-2850.101-2 159 001 393 Plug-in NIST traceable recertification tool, 2.5 μs simulated, 3-2850.101-3 159 001 394 Plug-in NIST traceable recertification tool, 10.0 μs simulated, 3-2850.101-4 159 001 395 Plug-in NIST traceable recertification tool, 18.2 MΩ simulated, 3-2850.101-5 159 001 396 Plug-in NIST traceable recertification tool, 10.0 MΩ simulated, 3-2850-61 159 001 400 Universal junction box, conductivity electronics, digital (S 3 L) output 3-2850-62 159 001 401 Universal junction box, conductivity electronics, 4 to 20 output 3-8052 159 000 188 ¾ in. integral mounting kit 5523-0322 159 000 761 Sensor cable (per ft), 3 cond. plus shield, 22 AWG, for cable extension through a junction box for the following sensors: 3-2840, 3-2841, 3-2842 3-8050-1 159 000 753 Universal mount junction box 3-2839-1V.099 Rev D (04/17) Georg Fischer Signet LLC 3401 Aero Jet Avenue, El Monte, CA 91731-2882 U.S.A. Tel. (626) 571-2770 Fax (626) 573-2057 e-mail: signet.ps@georgfischer.com Specifications subject to change without notice. All rights reserved. All corporate names and trademarks stated herein are the property of their respective companies.