ESA Pyronics International R&D test center

Similar documents
PACKAGED METALLIC BURNERS

EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00

INFRA-RED BURNERS BR-70 SERIES FEATURES APPLICATIONS. Bulletin E3005 rev03 31/01/00

FLAT FLAME AND EXCESS AIR BURNERS

Burners. Self-recuperative burners high speed free flame REKO-SIK-NxT-FF (E3901FN rev /02/2018)

Burners. Self-recuperative burners high speed free flame REKO-SIK-FF (E3901F rev /08/2015)

25 Years IBS GmbH. Innovative and taylormade burner systems

Burners. Monoblock free flame burners EPB (E3007 rev /11/2017)

Electronics. Microprocessor operated burner control device ESA ESTRO (E7014 rev /11/2009)

SELF - RECUPERATIVE BURNERS HIGH SPEED FREE FLAME REKO-SIK-FF. E3901FF rev /05/2009.

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

Burners. Monoblock free flame burners EPB (E3007 rev /07/2016)

1 - High-velocity gas burners

MICROPROCESSOR OPERATED BURNER CONTROL DEVICE ESA ESTRO SERIE

Ecomax. Direct-Fired Self-Recuperative Metallic Gas Burner. Features

Trends for Radiant Tube Heated Strip Lines

DELTA-TE III. Nozzle-mix line burner

EQUIPMENT GLASS LEVEL MEASURING SYSTEMS STIRRERS BOOSTER BURNERS THROAT BOOSTER BUBBLERS

Burners. Long flame burners Nozzle Mix NM - (E3501 rev /05/2015)

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

We offer ceramic radiant heaters and infra-red radiant tubes.

Electronics. Burner control and flame detector for permanent and not-permanent operation ESA REFLAM-H (E7802 rev /04/2017)

Since 1983 Nuova COTERM has developed a wide range of water heaters.

OVENS LINE. Pocket 4060 rack oven for bread and pastry

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

User friendly side control

PCH Heating Condensing Module for Air Handling and Roof Top Units

LOW-NOX BURNER RETROFIT CHALLENGE

Small Capacity Regenerative Burners


Electronics. Serial Gateway for Esa Estro and Esa Reflam ESA BRIDGE & ESA EXP-3 (E7015 rev /01/2017)

FURNACES & OVENS LEADING INNOVATORS IN THERMAL TECHNOLOGY TO THE OIL & GAS, CHEMICAL AND POWER INDUSTRIES ASSET INTEGRITY PARTNER

Improving the Performance and Reliability of Fired Heaters and Boilers

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

Rapid. Suspended Warm Air Heater. Caring for the environment!

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

"HC" AIRFLO. In-duct firing line burner

LOW NOx MODULATING GAS BURNERS

PYRO-LINE BURNERS 126LX 6LE 12LS DESCRIPTION MODEL: 3201

V-Line. Nozzle-mix line burner

Zantingh Burner systems. Reliable energy-saving and environmentally friendly heating solutions

Self-recuperative burner for gas

GAS ABSORPTION HEAT PUMP

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Easyfire Standalone biomass pellet boiler

PESIT-Bangalore South Campus

Front Control FA01VS000IXS FA02VS000HXS FA02RS000BXS. Soft Line 3. Features. Features. Features. Electric Hob 30 cm

OIL AND GAS INDUSTRY

Pulse Firing Doubles Capacity and Cuts Fuel Costs

Bosch Uni 7000F Cast Iron Hot Water Boiler

RS /E-EV C01 SERIES

* Automatic boiler for burning pellets with power 8kW r. The smallest, certified boiler * in Poland 8kW

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

DESIGN PHILOSOPHY. Indirect bath heaters have a wide variety of successful applications in the oil and gas

B - BEST O - ORIGINAL. R - Renown. N - Name. I n H e a t e r s

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

REFRESH, UPGRADE, PERFORM. Revamping Kits and Digital Solutions for quality improvement and energy savings

fire resistant cables

operations, Environmental & Instrumentation engineering solutions to the Commercial & Industrial segment in the Middle East. ARE

* Automatic boiler for burning pellets with power 8kW r. The smallest, certified boiler * in Poland 8kW

Ciao Green Condensing Wall-Hung Boilers

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Natural Gas Savings in Industry

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

HV-50 HVOF Thermal Spray System

SCHNEIDER-KESSEL BERLIN

Submittal Data GAHP Line W LB Series Ground Source Gas Fired Absorption Heat Pump Heating and Cooling

Energy recovery from exhaust gases using Heat Pipe technology

Oil and gas solutions. Unicon boiler plants for steam and hot water production

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

INTEC Engineering GmbH Energy systems

PORTABLE HEATERS FOR PROFESSIONAL use

Series LV AIRFLO. In-duct firing line burner

STATIONARY HEATERS 2011/

Prextherm Rsw High efficiency steel pressurised boilers

Energy-Efficiency Measures List

DH-Direct Fired Poultry Farm Diesel Heater

Product Lists NO.1- WNS horizontal wet back steam boiler

RS /E-EV C01 SERIES

CombustionONE. Improving and Sustaining the Combustion Asset. Driven by the New Standards. Bulletin 53A90A01-01E-A

PORTABLE HEATERS MCS GROUP.

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

Electronics. Pulse Firing controller for Esa Estro and Esa Reflam ESA PLEX-PULSE (E7108 rev /12/2016)

Mynute Green Condensing Wall-Hung Boilers

MULTIPLEX SELF RECUPERATIVE gas burner

Floor standing boilers. RMG Mk.II RS Mk.II

PCH/new Series. High performance, total flexibility

A New Standard of Excellence

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

TWO STAGE HEAVY OIL BURNERS

26 Mesh Belt Brazing Annealing Furnace. Continuous Mesh Belt Brazing Furnace

(Text with EEA relevance) Reference and title of the harmonised standard (and reference document) EN 26:1997/A1:2000 Note 3 Date expired (18.7.

RIELLO 40 GS/M SERIES

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

Thermal processing equipment design and craft for laboratories and industry Vilnius, Lietuva

Gas condensing boiler (wall mounted) TopGas

PUSHING THE LIMITS OF WHAT IS POSSIBLE

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

Transcription:

A new frontier for the Research and Development combustion tecnologies ESA Pyronics International has, over the years, acquired a reputation on a worldwide level for the manufacturing quality of its products. All this is the result of more than thirty years of experience in industrial combustion plants. Upon reaching these results, no company can work professionally without dedicating an area to research and development. The R&D department must respond in adequate manner and time to every new expectation that the market demands. ESA Pyronics International had its own Research and Development structure since 1992 on the company s premises in Curno (BG - Italy). It supplies fundamental support for the developing of new products as well as a continuous improvement of the standard product range. It is also the area where our technical staff are constantly gaining experience and competence. The R&D department is essential to show our clients how the products that will then be installed on an actual plant, function. Research & Development During the first few months of 2010, following a choice made by the company, the R&D department was expanded and concentrated in one single area of about 1000 m sq including a strorehouse. It was also decided to equip ourselves with a new furnace to test high capacity burners up to 4 MW. This new testing furnace has been operating since December 2010. Up till today, the R&D center in Curno is equipped with furnaces that are used for combustion tests, efficiency and consumption monitoring, analysis of combustion products: All the activities are registered and documented by drawing up data sheets supported by photographs and films. Furnaces F1: F2: F3: F4: F5: F6: F7: F8: Capacity 2 MW 100 kw 500 kw 200 kw 400 kw 60 kw 4 MW 150kW A view of the new ESA Pyronics International R&D Test Center in Curno (Bergamo) - Italy

Fixed test furnace F1 and air heater The furnace is used for long flame burners or for roof radiant burners up to a maximum power of 2MW, fed by natural gas, LPG, different gases (COG, BFG) or diesel oil. It is equipped with n. 2 cooled inspection windows. 6200 x 2200 x 1600H. N 1 frontal fitting for burner Ø780 with max air inlet ND350 (2MW max). N 1 roof fitting for burner Ø500 with max air inlet ND150 (500kW max). N 1 roof fitting for burner Ø600 with max air inlet ND150 (1000kW max). Max furnace temperature 1300 C. Max preheated air temperature 550 C. Tubular bundle type air exchanger and radiant tube exchanger Max air flow Qmax=2000Nm3/h @500 C. SIEMENS ULTRAMAT 23 fixed fume analyzer (O2, CO e NO/NOx). N 6 S series thermocouples (4 on side wall and 2 on roof). Automatic chamber pressure control. Furnace F1 2 MW Long flame fuel oil or gas burner Tmax=1300 C Air heater 2 x 150 kw Air preheated up to 500 C, Qmax=2000Nm3/h @500 C A view of the fixed test furnace F1 and air heater in Curno (Bergamo) - Italy

Mobile test furnace F2 The furnace is used to test medium high velocity low power burners (up to 100kW), self recuperative burners or straight radiant tube burners up to Ø200 and lg.2500. It is equipped with n. 5 cooled inspection windows. 2800 x 600 x 400H N 1 frontal fitting for burner Ø250 with max air inlet ND65 (100kW max). Max. furnace temperature 1150 C. Max. air flow Qmax=120Nm3/h @500 C with external heater. TESTO 330/335/340 series portabile fume analyzer (O2, CO e NO/NOx). N 1 S series thermocouple for thermoregulation. Furnace F2 100 kw Medium/high velocity burners, straight radiant tubes. Tmax=1150 C Mobile test furnace F2 and a view of the flame.

Fixed test furnace F3 The furnace is intended for demonstration purposes, for flame shape and length analysis. It is used to test medium/high velocity burners with medium powers (up to 500kW), fed by natural gas, LPG, different gases (COG, BFG) or diesel oil. It is provided with n. 10 inspection windows. 3000 x 1600 x 1400H N 4 frontal fittings for burner Ø250 with max air inlet ND150 (600kW max). N 3 side fittings for burner Ø80 with max air inlet ND50 (100kW max). 600 C. Maximum air flow Qmax=700Nm3/h @30 C. Furnace F3 500 kw Medium/high velocity gas or fuel oil burners. Tmax=600 C Fixed test furnace F3

Mobile test furnace F4 The furnace is used to test medium/high velocity burners having low/medium power (up to 200kW), self recuperative burners or for burners with M and 2P radiant tubes. It is equipped with n. 2 cooled inspection windows. 1800 x 1400 x 800H N 1 frontal fitting for burners Ø300 with max air inlet ND100 (200kW max). N 1 side fitting for M/2P radiant tubes (200kW max). 1250 C. Maximum air flow Qmax=250Nm3/h @450 C with external heater. TESTO 330/335/340 series portable fume analyzer (O2, CO e NO/NOx). N 1 S series thermocouple for thermoregulation. Furnace F4 200 kw Medium/high velocity burners with U/M/P/2P radiant tubes. Tmax=1250 C Mobile test furnace F4

Fixed test furnace F5 The furnace is used to test medium/high velocity burners having low/medium power (up to 500kW), self recupative burners or M and 2P radiant tube burners, roof radiant burners. It has n. 1 cooled inspection window. 2400 x 1600 x 1600H N 1 frontal fitting for burners Ø250 with max air inlet ND150 (500kW max). N 1 roof fitting for burners Ø500 with max air inlet ND150 (500kW max). 1250 C. Maximum air flow Qmax=600Nm3/h @450 C with external heater. TESTO 330/335/340 series portable fume analyzer (O2, CO e NO/NOx). N 1 S series thermocouple for thermoregulation + n 4 S thermocouples for flame temperature measurement. Furnace F5 400 kw Medium/high velocity burners and roof radiant burners. Tmax=1300 C Fixed test furnace F5

Mobile test furnace F6 The furnace is used to test medium/high velocity low power burners (up to 60kW), self recuperative burners or straight radiant tube up to Ø200 e lg.2200. It is equipped with n. 3 cooled inspection windows. 2400 x 300 x 300H N 1 frontal fitting for burners Ø150 with max air inlet ND50 (60kW max). 1000 C. Maximum air flow Qmax=70Nm3/h @500 C with external heater. TESTO 330/335/340 series portable fume analyzer (O2, CO e NO/NOx). N 1 K thermocouple for thermoregulation. Furnace F6 60 kw Medium/high velocity burners, straight radiant tubes. Tmax=1000 C Mobile test furnace F6

Fixed test furnace F7 The furnace is used to test long flame or roof radiant flame burners with a maximum power of 4MW, fed by natural gas, LPG, different gases (COG, BFG) or diesel oil. It is equipped with n. 6 cooled inspection windows. 8000 x 2200 x 2000H N 1 frontal fitting for burners Ø950 with max air inlet ND400 (4MW max). N 1 roof fitting for burners Ø600 with max air inlet ND200 (1000kW max). 1300 C. Maximum preheated air temperature 500 C. Air exchanger with n 40 radiant tubes. N 12 water cooling tubes with evaporation towers having maximum absorption of 1200kW. Max. air flow Qmax=4000Nm3/h @500 C. TESTO 350XL series portable fume analyzer (O2, CO,NO/NOx e SO2). N 6 S series thermocouples (4 onside wall and 2 on roof). Fixed supervision television camera. Automatic chamber pressure control. Mobile front wall mounted on rails. Possibility of having different burner fittings by replacing the front wall of the furnace. Furnace F7 4 MW Long flame gas or fuel oil burners. Tmax=1300 C Fixed test furnace F7

Mobile air heater F8 The furnace is used to preheat combustion air up to 500 C and is mobile so it can be used near furnaces that use burners with preheated air. Maximum furnace power P=150kW 900 C. Maximum air flow Qmax=600Nm3/h @400 C. Qmax=400Nm3/h @500 C. N 1 K series thermocouple for air thermoregulation + n 1 K series thermocouple for chamber thermoregulation. Air heater F8 150kW Preheated air up to 450 C, Qmax=500Nm3/@450 C Mobile air heater F8

Furnace control systems The F1 and F7 furnaces have been respectively equipped with a Eurotherm and Rockwell system, which allows to manage and control the following processes: temperature to film and frame flame formation. ESA ESTRO flame control device for burner supervision Air and gas ratio Furnace temperature Burner flame Analysis of exhaust emissions Testing reports The systems are interfaced in Ethernet also with: The electrical panel with a view on the PLC control system software. Video cameras for high The flame control ESA ESTRO The control system software in action. 2012 ESA S.p.A. Company under the management and coordination of SIAD S.p.A. All rights reserved. The information contained herein is offered for use by technically qualifi ed personnel at their discretion and risk without warranty of any kind. We regularly update our data, for updated data please visit our web site www.esapyronics.com Printed in Italy Rev.02-08/12 www.esapyronics.com ESA S.p.A. Company under the management and coordination of SIAD S.p.A. Via E. Fermi, 40 I-24035 Curno (Bergamo) ITALY Tel. +39 035 6227411 esa@esacombustion.it www.esapyronics.com Fax +39 035 6227499