Herschel Infrared. Installer Guide. Herschel Infrared Ltd All Rights Reserved.

Similar documents
ECOLEC PANEL HEATERS GENERAL NOTES.

User Guide PLEASE READ BEFORE USE AND KEEP FOR FUTURE REFERENCE.

EH0533 Indoor Climate Control

EH0554 Indoor Climate Control

Thank you for choosing EnviroVent

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

HAVERLAND APP. The first self-programmable radiator and control from anywhere in the world INSTRUCTION MANUAL.

POWER SHOWERS Models 4500M 5002M 4500T 5002T

INFRARED PANEL HEATER

INSTALLATION & USER INSTRUCTIONS

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

The feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn.

Installation Guide For your AHT Underfloor Heating System

HERSCHEL SUMMIT 2600 HERSCHEL SUMMIT 2600R Ceiling or Wall-mounted Infrared Heaters

Ecostrad Amalfi. Wall-mounted Infrared Heater INSTALLATION & OPERATING INSTRUCTIONS. 3kg 2 Years (excludes lamp & remote control) IP65

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

INSTALLATION & USER INSTRUCTIONS

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR CARE GIFT SET MODEL C85003

Vari-Cyclone Ceiling Fans

IMPORTANT SAFETY INFORMATION:

stylish, energy efficient, sustainable electric heating solution for every living space

The feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn.

Installation Manual Local Ventilation System with Heat Recovery Type e² and e² short

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

Cooker Hood CHIM60 CHIM70 CHIM90 CHIM101 CHIM110. Installation & User s instructions

Wiring the fan correctly...

Vari-Fan Ceiling Fans

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS

Insert Electric Fireplace IF-40FSB IF-50FSB IF-60FSB. Please read all instructions carefully and Retain for future reference

ferroli Boiler Replacement Maxima 35C- Modena HE

Gallery Electric Fireplaces

INSTALLATION AND OPERATION INSTRUCTIONS FOR SAFETY INFORMATION WARNING

IMPORTANT SAFETY INFORMATION:

Atmos EasySolar. Installation Instructions for. Sloping roof and flat roof installation with evacuated tube collector

Installation Instructions & Operating Manual IMPORTANT

Homeowner s Installation Instructions & Operating Manual

DCO3 Operating Manual DYSON CUSTOMER HELPLINE am to 8pm, 7 DAYS A WEEK

RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

STR-600 Impact Dryer

DATASHEET Pro Heating PE Series. 5 Years Product Warranty

BLOW DRY & GO HAIR KIT

Gallery Electric Fireplaces

Lo-Carbon T-series Window & Roof Models

Homeowner s Installation Instructions & Operating Manual

Infrared Wall Mount Occupancy Sensor

Version 1.1. S88 W1M-B User Guide _User guide 25/02/ :03 Page 12

Installation and technical manual

IMPORTANT SAFETY INSTRUCTIONS

IR PANEL HEATER MANUAL

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. COMPOSITE FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

2 Installation Instructions For Vari-Fan Ceiling Fans Installation Instructions For Vari-Fan Ceiling Fans 11

CENTRAL HOUSING GROUP LTD. General Property Standards Guide

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

EH1688. Over Door Heater & Fan Chauffage de Porte & Ventilateur

Type UB-2502A and UB-3002A Forced-Air Heater

INSTALLATION AND OPERATION INSTRUCTIONS FOR

5000 INSTALLATION GUIDE

HOTLINE:

Vax Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website: vax.co.uk. Version 1.

INSTALLATION & USER INSTRUCTIONS

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

SURFACE WARM CEILING HEATERS

Installing and operating your Cabinet Cooling System, with Digital Thermostat

Installing and operating your Enclosed Cabinet Cooling System and digital thermostat

HARTFORD SLIM ASSEMBLY INSTRUCTIONS. IMPORTANT - RETAIN FOR FUTURE REFERENCE - READ CAREFULLY.

EH kW Panel Heater

Scottish Infrared Heating

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual

Vax Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website: vax.co.uk. Version 1.

Carbon Film Installation Instructions

Q1. Carefully read the following extract from a safety leaflet. Then answer the questions.

2-ZONE EASYFIT INTRUDER ALARM

Consumer Products Catalog

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Electric Fireplace Instruction Manual

School Fire Safety. A Guide for Educators. saskatchewan.ca

2-ZONE EASYFIT INTRUDER ALARM

SmartRad Planning Manual

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

User and Installation Instructions. Opus 700 Electric Wet Well Bain Marie OE7601 IS195 ECN2396

GLASS HEATER OWNER S MANUAL. Model No. GH-15A

INSTALLATION & USER INSTRUCTIONS

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Turbo Lite Corded Handheld Stick Vacuum

ASHDOWN STOVE SUITE

Model: DC-159. Instruction Manual

INSTALLATION USE AND MAINTENANCE MANUAL. ATC Evolution ATC EVOLUTION. Class I - IP55 INFRARED HEATER ATC ELECTRICAL & MECHANICAL

Have a Question? Call Us First! Adjustable Ionic Dyer. Please do not return this product to the retailer.

Serene Classic Rails

Steam Fresh Let s get started

INFRARED ZONE HEATING SYSTEM

10,000 prize draw. instructions. EXTRA year guarantee FREE rewards gallery. details. Register online now!

Underlaminate Foil Heater

LUCCI AIRFUSION BREEZE WALL FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE

ELECTRIC FIREPLACE with Remote Control

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

WHAT S IN THE BOX? The IQ Panel also includes a snap on table stand and power supply with cable.

Use numbers given in the box to complete the following sentences. In the UK, the mains electricity supply is volts.

Step 1: Identify the parts of your shade (parts shown are not to scale)

Transcription:

Herschel Infrared Installer Guide Herschel Infrared Ltd 2015. All Rights Reserved.

Where to position in a room Where the people are What is the room used-for and where will the people be? You want the best comfort for people. Where the thermal mass is Aim the heater where it can heat up materials that will absorb the heat (wood, carpets, stone walls) and avoid materials that will reflect it (shiny surfaces) or let it pass through (glass). Cater for room shape A room which has complex shapes presents blind spots for Infrared Heating. Position heating to avoid cold spots (and avoid windows Long narrow rooms may require several heaters, so mounting from the ceiling may give better cover (especially if the wall has windows). Herschel Infrared Ltd 2015. All Rights Reserved.

Heater weights The mounting surface must be strong enough to bear the weight of the heater. Heaters can weigh anything from a few kilos to 28kg depending on size. For most, this load is spread between 2 to 4 mounting brackets depending on the type of unit or panel being mounted. For the Pulsar at 28kg it is a single eye for mounting via cable. Your surface must be capable of holding the entire weight of the heater. Ensure adequate hard points exist to ensure this. For ceiling-mounted heaters you are looking at a weight of between 4-8kg. Be especially careful to ensure the correct mount is used (details in installation instructions) and that the heater cannot possibly move once mounted. If a heater is to be fitted into a ceiling grid, the grid and grid-bearers must have the combined strength to hold the weight of all the panels - which will be considerably more than the previous acoustic tiles. For any type of ceiling-mounted heaters the mount must be able to support the weight of the heaters, plus supporting wire and electric wire. Herschel Infrared Ltd 2015. All Rights Reserved.

Herschel Select Technical details Herschel Select: Rear view Herschel Infrared Ltd 2015. All Rights Reserved.

Herschel Select XL Technical details

Herschel Inspire Technical details

Panel Precautions Be sure to read the installer guides also supplied with each unit. If your electric supply exceeds 250 Volts, do not use the heater and contact your supplier. Mount all heaters out of the reach of children. The minimum distance of the panel to the floor should be 1.2m. As with any heater, avoid the possibility of people being able accidentally to fall against the heater or being unable to move away from it. The space between the rear of the panel and the wall must be unobstructed. A minimum 25mm should exist between the edges of the panel and ceilings (this does not apply to panels mounted in a ceiling grid). The minimum distance to objects in front of the heater must be 400mm and 200mm clear either side. Never mount the heater where there is a risk it could fall into any kind of water container. Do not install in rooms where direct contact with water is possible. The electrical circuit to power the heater must be capable of disconnection and de-activation by a switch, fuse, RCD or GFCI. Never drill through the panel surface. The heater must be cold for dismounting and moving.

Mounting the Select Panel Stick the template to the wall you intend to hang the heater ensuring: a) The template itself is level The power box is in the corner you want it in (relative to mains). b) Note which hole you need to be drilling! (In this case the A s ) Herschel Infrared Ltd 2015. All Rights Reserved.

Mounting the panel - 2 Arrange the mounting hardware and fabric insulation pads. Remove backing film and carefully stick-in-place the insulation pads on the rear of the panel. (Double check!) Drill the hole on the template that is correct for the orientation on the wall. (In this case it is the holes marked A ). Remove the template. Insert rawlplugs and screwin mounting screws, leaving the screw head and 2-3mm of shank exposed (to mount the brackets on). Herschel Infrared Ltd 2015. All Rights Reserved.

Technical details of Herschel Space Heaters (not to scale) Herschel Infrared Ltd 2015. All Rights Reserved.

Space Heater Precautions Be sure to read the installer guides also supplied with each unit. If your electric supply exceeds 250 Volts, do not use the heater and contact your supplier. The unit rises to very high temperatures in use and must never be touched when on and left for 30 minutes to cool down before handling. Mount all heaters out of reach. The minimum distance of the unit to the floor should be 2.3 2.5m with the heater mounted at 60. Never mount the heater perpendicularly downwards. The minimum distance of the unit to the ceiling must be 300mm. Overhead cover of 2m must be available above the heater if the heater is for outside use. Do not install the heater near to any combustible material. As with any heater, avoid the possibility of people being able accidentally to fall against the heater or being unable to move away from it. Never mount the heater where there is a risk it could fall into any kind of water container. Do not install in places where direct contact with water is possible. The electrical circuit to power the heater must be separately switched or a switched spur taken from the ring main. Power to the device must be capable of disconnection and de-activation by a switch, RCD, GFCI or fuse, the rating of which should follow table 1 (previous slide). Permanent cable to the heater up-to the supplied cable must be correctly rated solid core. Flexible cable is prohibited by IEE regulations which also preclude the use of a 13A plug and socket for these installations.

Notes about placement A thermostat for an Infrared panel needs to be placed as far away as practical from the panel within limits of the power lead (for plug-in types), ideally at panel-level and at approximately 90% * of the limits of zone to be heated (for remote controller types). Plug-in type controls: Remote controller type controls: (Zone to be heated) Ideal thermostat placement is in-line with panel height, but this is not usually practical due to socket placement. Place controller 1.5m from floor. * Placement of the controller at 90% of the zone limit allows you enough flexibility to experiment with time and temperature to reach the desired comfort level. At 100% of zone limits, you lose this flexibility and the heater may mostly be on.

In-line plugin type Suitability: Single Room, Single Zone, Single Panel Basic wiring: Single panel plugs into thermostat, which plugs into 13 amp domestic socket. Multiple panels in same room: Use a centralised wireless controller-type (next page) to avoid interlock (one panel s thermostat reacting to another panel s heat). Circuit capacity: Either add panels to existing 16 Amp ring assessed for average of overall consumption and do not exceed average maximum load. Or create dedicated 16 Amp ring specifically for use by infrared panels. Do not exceed average maximum load.

Wireless Control with plugin receiver Suitability: Single Room, Single Zone, Multiple Panels RF waves Remotely mounted Thermostatic Control (Battery Powered) Basic wiring: Single panel plugs into Wireless receiver, which plugs into 13 amp domestic socket. Remote Thermostatic control is battery powered. Multiple panels in same room: Remotely mounted controller will control up to 4 wireless receivers in a room. Not suitable for controlling multiple rooms / different zones. Circuit capacity: Either add panels to existing 16 Amp ring assessed for average of overall consumption and do not exceed average maximum load. Or create dedicated 16 Amp ring specifically for use by infrared panels. Do not exceed average maximum load. Herschel Infrared Ltd 2015. All Rights Reserved.

Wireless control with wired receiver Distributed Control Configuration - one receiver / thermostat combination per spur = Individual control per spur Distribution Board Fused Spur Receiver Note: Thermostat-Receiver no more than 20m apart

Wireless control with wired receiver Centralised Control Configuration - One receiver / thermostat combination per distribution board. = Centralised control of all spurs (e.g. like central heating). Distribution Board Fused Spur Receiver Note: Thermostat-Receiver no more than 20m apart

Space Heater Controller Installation Distributed Control Configuration: One receiver / Thermostat combination per zone = Individual control per spur / group of spurs Fused Spur Distribution Board Contactors Fused Spur Receiver Fused Spur Note: Thermostat-Receiver no more than 20m apart Fused Spur

Space Heater Controller Installation Centralised Control Configuration: One Receiver / Thermostat combination per distribution board = Centralised control of all spurs Fused Spur Distribution Board Contactor Receiver Fused Spur Note: Thermostat-Receiver no more than 20m apart

Whole house building management using Wireless Thermostat Controls Suitability: Multi-Room, Multi-Zone, Single & Multiple Panels Part of centralised management system Part of mixed heat-source system Zone 1 Bedroom Zone 3 Bathroom Battery-operated controller Battery-operated controller RF waves Switched or fused spur Switched or fused spur Zone 2 Living Room Battery-operated controller Zone 4 Bedroom 2 Battery-operated controller DC Transformer Switched or fused spur Switched or fused spur Battery-operated receivers Herschel Infrared Ltd 2015. All Rights Reserved.

More information Apply for (free) membership of Herschel s Infrared Technology Centre where we provide online training and accreditation as well as regular news and a forum for technical questions. http://www.herschel-infrared-technology-centre.com