OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE

Similar documents
USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES

USER MANUAL OLM SERIES WARM AIR OIL FIRED FURNACE

USER MANUAL SOM SERIES MUL-T-POISE WARM AIR OIL FIRED FURNACE

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

OIL FIRED WARM AIR FURNACE. Homeowner Instructions

DOMESTIC WATER HEATER OIL FIRED

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

UNITARY PRODUCTS GROUP

USER S INFORMATION MANUAL (2,4)SG13B

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

User s Information Manual

USER S INFORMATION MANUAL

AIR CONDITIONER ELECTRONIC CONTROL

user s information manual

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

ML180UH SERIES GAS FURNACE WARNING WARNING

OWNER S MANUAL. Important: Read carefully before assembly and use. PORTABLE CANISTER U #961A00007 ID111867

Bosch 80% AFUE Gas Furnace BGS80 Model

SLIDER CASEMENT AIR CONDITIONER

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

USER S INFORMATION MANUAL

ROTARY CONTROL AIR CONDITIONER

e Heater/Exhaust Fan/Light User s Guide

Corn Flame Energy Corn Stove Model 3000

WARNING FIRE OR EXPLOSION HAZARD.

GL-DEH Series Portable Dehumidifier Operating Instructions

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

USER S INFORMATION MANUAL

LGA/LGC036, 042, 048, 060, 072 (3, 3-1/2, 4, 5, and 6 TONS) LGA/LGC090, 102, 120, 150, (7-1/2, 8-1/2, 10, and 12-1/2 TONS)

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

EL195UHE SERIES GAS FURNACE WARNING WARNING

EL296UHV SERIES GAS FURNACE WARNING WARNING

e Bath Fan with Light User s Guide

WARNING FIRE OR EXPLOSION HAZARD.

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE

Canister Vacuum. OWNER S MANUAL Models CV520HB/HR/HY 120V., 60Hz., 10 Amps

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

USER S INFORMATION MANUAL

USERS INFORMATION MANUAL

HANDY/STICK 2-WAY VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H055

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

e Bath Fan with Light User s Guide

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

e Bath Fan with Light User s Guide

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Installation, Operation and Service Manual

Oil Furnace USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

Xaact Spot. Xaact Hot Spot

Installation & Maintenance Instructions

Wax Base Heater & Dispenser

Turbo Stick Vac. OWNER S MANUAL Model EP V., 60Hz., 7.5 Amps.

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

Quest Power Electric Heat EHS 31 Pro

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the


USER S INFORMATION MANUAL

Installation Information

VSA/VSB & KSA/KSB Series Air Doors

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

USER S INFORMATION MANUAL

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

Fire-Water Bowls Model 100

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

USER S INFORMATION MANUAL NT-16SQ NT-20SQ

True Hepa Shark Plus Canister Vacuum Model EP238 Use and Care Instructions

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

XE SERIES INDOOR INDIRECT GAS FIRED HEATING UNIT

OWN ER'SGUIDE READ AND SAVE THESE INSTRUCTIONS

Integra Family. Operations Manual. Models: Integra TX SS, Integra HD, Integra DS, Integra DS LA, Integra UHS, Machine Name: Serial Number:

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

G61MPV SERIES GAS FURNACE WARNING

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

DF Series Furnace. Models DFSAD12, DFSD12, DFSD16, DFSD20, DFMD16, DFMD20, DFMD25, DFMD30, DFMD35, DFLD35, DFLD40, DFLA35, DFLA40

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

USER'S MANUAL PGE Single Package Rooftop

Horizontal Bottle Cooler Installation and Operation Manual

Installation & Operation Manual Ice Cream Freezers

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Combination Cooling/Gas Heat Package Units

Installation Instructions

EL195UH SERIES GAS FURNACE WARNING

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Portable Dehumidifier with Internal Pump

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.

User s Information Manual

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

User s Information Manual

Owner s Information Manual

ADDISON Freestanding Electric Stove Models: ACSB

Owner s Manual Phoenix FireBird

Transcription:

OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE Save These Instructions For Reference SMO 112 FURNACES ARE AIR CONDITIONING READY! NOTICE TO HOMEOWNER THIS FURNACE SHALL BE INSTALLED BY A CERTIFIED INSTALLER AND WHERE REQUIRED BY LAW, A LICENSED TECHNICIAN NOTICE TO HOMEOWNER IF YOUR SUMMERAIRE SMO112 OIL FURNACE HAS BEEN INSTALLED USING THE APPROVED SS1-C TJERNLUND SIDEWALL POWER VENTOR; IT IS YOUR RESPONSIBILITY TO KEEP THE AREA AROUND THE VENT TERMINAL FREE OF ICE, SNOW, AND DEBRIS FOR SERVICE CALL: INSTALLATION INFORMATION Installing Contractor Unit Model Number Telephone Number Unit Serial Number Installation Date Summeraire Mfg. Peterborough, Ontario K9J 7B1 OCT., 2007R

OPERATING INSTRUCTIONS CAUTION: NEVER BURN GARBAGE, REFUSE OR PAPER IN THE HEATING UNIT. NEVER LEAVE COMBUSTIBLE OR OTHER MATERIALS AROUND OR NEAR THE FURNACE. NOTE: AN OPTIONAL VESTIBULE IS AVAILABLE FOR THE SMO112 FURNACE THE VESTIBULE COMPLETELY ENCLOSES THE OIL BURNER IDENTIFY THE LOCATION OF YOUR BURNER / FURNACE POWER SWITCH OIL BURNER OPERATING INSTRUCTIONS Use No 2 furnace oil ONLY Do not use gasoline, crankcase oil, or any oil containing gasoline. Do not attempt to start the burner if excess oil has accumulated, when the furnace is full of vapor, or if the combustion chamber is hot. Press the burner relay reset button ONLY ONCE; if the burner fails to start, call an Oil Burner Technician. If the oil burner is to be shut off for any period of time, shut the oil valve OFF at the oil tank. Do not adjust or tamper with the furnace or any of the controls Do not burn garbage or paper in this unit. Never leave paper, rags, or other combustibles around the furnace. Only qualified, or where required by law, a licensed technician shall set up this unit and adjust controls. DO NOT START THE OIL BURNER UNLESS THE BLOWER DOOR IS SECURED IN PLACE. TO TURN THE BURNER OFF Turn the main oil burner switch to OFF Set the thermostat as far below room temperature as possible. IF BURNER IS TO BE SHUT OFF FOR AN EXTENDED PERIOD. Turn main oil burner switch to OFF. Close all oil supply valves. The heating system should be checked and cleaned if necessary. BURNER FAILS TO OPERATE Always call a qualified technician The trouble may be : Raise your thermostat to 5º C ( 10º F ) above present room temperature Make sure your Oil Burner power switch is in the ON position If you hear a hum from the oil burner, and the motor has not started, press the reset button on the burner motor once only. Blown fuse / tripped breaker in electrical panel Thermostat may be set below room temperature. Burner relay ( combustion control ) may have to be reset ( press reset once only ) Oil valve may be closed. Oil supply may be too low. Blocked flue sensor tripped If the oil burner fails to start or runs for only a few seconds, call a qualified service technician. 2

RESTARTING BURNER AFTER EXTENDED SHUT DOWN. The complete oil burner should be checked and serviced by a qualified technician. Check oil pump strainer Replace oil filter cartridge Check electrodes Oil burner motor ( see lubrication section ) Restart burner by following instructions in; STARTING THE OIL BURNER section. If your furnace has been shut off for an extended period contact your qualified service technician for start - up SUMMER FAN OPERATION During summer, continuous air circulation can be obtained by pulling / sliding the manual fan switch from the Auto position to the On position DUAL AIR OPERATION This furnace is equipped with a dual ( two ) speed blower system which allows partial air distribution at all times. When the thermostat calls for Heat, the Oil Burner starts and the HIGH speed quickly distributes warm air throughout the home. When the HIGH SPEED stops, the LOW speed continues operating, circulating the air to even the temperature throughout the house. If the LOW speed feature is not required / desired, operate the small rocker switch located on the power junction box. MAINTENANCE OIL FURNACE ANNUAL SERVICE The oil burner and furnace should be thoroughly cleaned and serviced annually by a qualified service technician, and where required by law, a licensed technician. CAUTION : Do not use any commercially available soot remover. Use extreme caution when servicing since the combustion chamber is fragile. Routine cleaning of the flue passages does not require cleaning the combustion chamber. If for some reason, it is necessary to work in the area of the combustion chamber, do not touch or alter the chamber position. Before cleaning, shut off electrical power supply to the furnace. Note : Always keep oil supply valve shut off if burner is shut down for an extended period of time. The nozzle should be replaced annually handle nozzle with care so that the inside surface tip is not scratched. The electrodes should be cleaned and adjusted. (see oil burner manual supplied with the oil burner). LUBRICATION Apply 2 3 drops of SAE 20 30 Non Detergent oil ONLY to the oil port(s) located at either end of the burner motor. Apply 2 3 drops of SAE 20 30 Non Detergent oil ONLY to the oil ports located at either end of the blower motor. DO NOT OIL THE FAN BEARINGS! 3

BEFORE CLEANING THE FURNACE SHUT OFF ELECTRICAL POWER SUPPLY CLEANING THE SMO112 Remove smoke pipe and cleanout plate on rear of furnace. Remove baffles ( 5 ) from secondary heat exchanger. Loosen soot from the secondary heat exchanger with a cleaning tool or stiff brush. Remove all loose soot with a vacuum cleaner suitable for this purpose. Inspect passages to check for missed areas. When reinstalling the cleanout cover plate, make sure to replace the gasket. NOTE: WE RECOMMEND THAT A QUALIFIED MECHANIC OR WHERE REQUIRED BY LAW, A LICENCED MECHANIC ONLY SHOULD PERFORM ALL SERVICE AND CLEANING OF YOUR SUMMERAIRE FURNACE! AIR FILTER This furnace should never be operated without filters. A DIRTY AIR FILTER CAUSES INEFFICIENCY AND HIGHER OPERATING COSTS Clean or replace filters each heating season, or as required. Filter specifications for the air filter installed in your Summeraire oil fired warm air furnace, are listed below. DO NOT SUBSTITUTE! Note: Changing the type or size of filter used in your Summeraire furnace can seriously affect the operation of the furnace! AIR FILTER SPECIFICATIONS Filter size : 20 X 20 x 1 CSA or ULC Certified /Approved Type: Throw away / disposable. USE OF FILTERS OTHER THAN THOSE SPECIFIED ABOVE, CAN CAUSE DANGEROUS ELEVATION OF FURNACE TEMPERATURES THIS IS AN UNSAFE CONDITION! DO NOT USE / INSTALL PLEATED TYPE AIR FILTERS IN THIS FURNACE! WARNING: Your furnace requires Combustion Air DO NOT close off furnace room or enclose furnace - this will starve to furnace oil burner for air necessary for combustion and could result in a dangerous situation. NOTE: IF YOUR SUMMERAIRE FURNACE IS INSTALLED WITH A SS1-C TJERNLUND SIDEWALL POWER VENTOR. IT IS THE USERS / HOMEOWNERS RESPONSIBILITY TO KEEP THE AREA AROUND THE VENT TERMINAL FREE OF ICE, SNOW AND DEBRIS! 4

WARRANTY: Summeraire Mfg. warrants that it will supply to the owner of a Summeraire Oil furnace that has been installed in Canada, a replacement Heat Exchanger (Heat Element) free of charge F.O.B. Factory, Peterborough, Ontario, Canada. If the said Heat Exchanger wears out or fails under normal use and service due to a defect in material or workmanship during the first Twenty (20) years after the date of installation and only if the following conditions have been met. 1. The furnace has been installed and maintained in accordance with accepted practices as recommended from time to time by the Heating Refrigeration and Air Conditioning Institute of Canada; The National Building Code, or CSA standard B139 by a qualified installer. 2. The furnace has been operated with an input rate not in excess of the rating and fuel as specified on the rating plate attached to the furnace. 3. The furnace has not been operated with out the use of the proper automatic limit control on the maximum warm air temperature. 4. That the furnace has not been operated without adequate air circulation over it. 5. Proof satisfactory to Summeraire Mfg., that the defect claimed has not been caused by damage to, or destruction of the furnace. 6. The furnace has remained at all times in the place of initial installation. 7. Written notification of the failure under terms and conditions of this warranty are provided no later than thirty (30) days after the expiration of this warranty whichever shall first occur. 8. No mechanically cooled air. Originating in the return air duct shall be circulated over the heat exchanger of the furnace. 9. The owner must provide proof that the appliance has been serviced annually, including annual cleaning of the complete furnace and, inspection of the heat exchanger. 10. The unit must not be installed in any structure where a corrosive atmosphere exists as may be found in dry cleaning establishments, Laundromats, Beauty Salons, etc. 11. Summeraire Mfg. shall not be responsible for any failure due to water damage and/ or Acts of God. 12. No Air Conditioning or Heat pump coil may be installed on the return air side of this furnace. This warranty expressly supersedes all other warranties and obligations of Summeraire Mfg. No person has authority to alter or modify the terms of this warranty in any manner. Summeraire Mfg. assumes no liability for consequential damages of any kind, and the purchaser, by acceptance of this Equipment assumes all liability for the consequence of its use or misuse, by the purchaser, his employee or others. This Warranty is for the benefit of the owner of the furnace and terminates in the event of any alterations not specified by Summeraire Mfg. and other than herein provided. No further or other warranty, express or implied, is granted by this warranty and no liability shall accrue for any consequential damage resulting from alleged defects in the Heat Exchanger or its component parts. Mechanical components for this furnace are covered under a five (5) year warranty. If these components fail under normal use and service within five (5) years from date of installation, the defective part will be replaced free of charge, F.O.B. our factory in Peterborough, Ontario. The Model Number and Serial Number of your Summeraire Furnace must accompany all claims for warranty. 5 F-SMO-USMAN-EN-REV4