AN EXPERIMENTAL INVESTIGATION INTO THE EFFECT OF THERMOSTAT SETTINGS ON THE ENERGY CONSUMPTION OF HOUSEHOLD REFRIGERATORS

Similar documents
MOISTURE TRANSFER AND ENERGY LOSSES OF HOUSEHOLD REFRIGERATOR- FREEZER DURING THE CLOSED DOOR OPERATION

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

CHARACTERISTICS AND COP CASCADE REFRIGERATION SYSTEM USING HYDROCARBON REFRIGERANT (PROPANE, ETHANE AND CO 2 ) AT LOW TEMPERATURE CIRCUIT (LTC)

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

A study of Transient Performance of A Cascade Heat Pump System

Department of MCE, Islamic University of Technology 2. Abstract

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Pure Butane as Refrigerant in Domestic Refrigerator Freezer

Performance Analysis of a Domestic Refrigerator in Malaysia using Experimental Method

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

PERFORMANCE OF ICE SLURRY GENERATOR WITH MECHANICAL SCRAPER USING R-22 AND R-290. Fajri A. Rayhan 1, Agus S. Pamitran 1*

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Experimental study of R600a and R436a to replace R134a in a domestic refrigerator and freezer

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

HFC/HC BLEND FOR CAR CLIMATE CONTROL WITH MINERAL OIL AS LUBRICANT

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV)

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Enhancing the performance of the domestic refrigerator with hot gas injection to suction line

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

The lowest energy consumption when using R290 LBP fixed speed compressors in a plug in ice cream conservator

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C

Purdue e-pubs. Purdue University

Smart Defrost Control for Refrigeration System

Santanu Prasad Datta (Student) P. K. Das & S. Mukhopadhyay

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Transcritical CO2 Bottle Cooler Development

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Capillary Tube and Thermostatic Expansion Valve Comparative Analysis in Water Chiller Air Conditioning

DEEPAK PALIWAL, S.P.S.RAJPUT

Performance of an Improved Household Refrigerator/Freezer

Specific Energy Consumption of Heat Pump Drying System

Performance investigation of Air-conditioning system using ejector as expansion device

Sarthak Thakar, 2 R.P.Prajapati 1

Variable far infrared radiation (VFIR) technique for cubic carrot drying

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Experimental Investigation of a Heat Pump Assisted Fluidized Bed Dryer

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

LABORATORY STUDY ON THE CONSOLIDATION SETTLEMENT OF CLAY-FILLED GEOTEXTILE TUBE AND BAGS

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

η second law = Second law efficiency

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

A Statistical Analysis of a Liquid Desiccant Dehumidifier/Regenerator in an Air Conditioning System

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Compact Ultra Low Temperature Chamber

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

Performance enhancement of photovoltaic household refrigerator using a phase change material in contact with evaporator

Constant climate chamber with ICH-compliant illumination

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

PERFORMANCE IMPROVEMENT OF SPLIT AIR CONDITIONER USING EVAPORATIVE COOLING METHOD IN THE CLIMATIC CONDITION OF GUWAHATI, ASSAM

Effect of Parameters on Internal Flow Patterns of a Top Heat Mode Closed-loop Oscillating Heat Pipe with Check Valves (THMCLOHP/CV)

Performance Investigation of Domestic Refrigerator Using Pure Hydrocarbons and Blends of Hydrocarbons as Refrigerants

BUTANE, ISOBUTANE AND THEIR MIXTURES AS AN ALTERANTIVES TO R-134a IN DOMESTIC REFRIGERATOR

FSTC Equipment Test Report

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Application of a hybrid control of expansion valves to a 3-ton large room cooling system

Performance evaluation of an innovative fan-coil unit: Low-temperature differential variable air volume FCU

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Effect of Vacuum Cooling Operation Parameters on Cooling Time and Weight Loss of Chinese Cabbage

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Asian Journal on Energy and Environment

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Thermo Scientific ULT Freezers: Superior Thermal Performance

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Transcription:

International Journal of Technology (2018) 2: 364-371 ISSN 2086-9614 IJTech 2018 AN EXPERIMENTAL INVESTIGATION INTO THE EFFECT OF THERMOSTAT SETTINGS ON THE ENERGY CONSUMPTION OF HOUSEHOLD REFRIGERATORS Edy Susanto 1,2, M. Idrus Alhamid 2*, Nasruddin 2, Budihardjo 2 1 Faculty of Engineering, Universitas Samudra, Meurandeh, Langsa 24416, Indonesia 2 Department of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus UI Depok, Depok 16424, Indonesia (Received: December 2017 / Revised: December 2017 / Accepted: March 2018) ABSTRACT Many household refrigerator owners do not control their thermostat settings. However, doing this could save energy consumption and also maintain the quality of stored food. This study presents the effect of regulated thermostat settings on household refrigerator energy consumption. The experiment was performed in a room chamber conditioned to temperature control at 25 o C. A household refrigerator was used as a test unit, with a cooling load placed inside the freezer component. The cooling load used was an M-package, in accordance with SNI IEC 15502: 2008. The test results reveal that household refrigerator energy consumption increases with higher thermostat settings. Increases in energy consumption range from 17.10% to 18.65%, depending on the thermostat setting. Keywords: Consumption energy; Refrigerator; Room chamber; Setting thermostat 1. INTRODUCTION The household refrigerator is an integral part of our life. In Indonesia, the number of household refrigerators continues to rise as the population grows. Currently, household refrigerators rank second in household energy consumption after air conditioning, partly due to the fact that household refrigerators run continuously (Khan et al., 2013). The increasing number of household refrigerator users is due to improved household economies, easy availability of electricity and cheap prices (Hasanuzzaman et al., 2011). Meanwhile, a US survey in 2009 revealed that household refrigerators consume more than 25% of household electrical energy (EIA, 2015). Many studies have analyzed the factors that influence increases in household refrigerator energy consumption. Factors studied include the increase in energy consumption caused by ambient temperature, door openings, thermostat settings and cooling loads (Saidur et al., 2002; Hasanuzzaman, 2008). These variables combine to constitute the dominant factors that affect increases in household refrigerator energy consumption. Liu et al. (2004) conducted an experimental study on two types of household refrigerators by varying the number of door openings and ambient temperature. Their study showed that if the temperature of the unit rises due to opening of the door, then energy consumption also increases by 10% (Liu et al., 2004). Ozgun et al., performed optimization by varying the temperature and airflow into the evaporator to find household refrigerator energy efficiency (Sakalli et al., 2017). *Corresponding author s email: mamak@eng.ui.ac.id, Tel: +62-21-5422-0808, Fax: +62-21-5422-0800 Permalink/DOI: https://doi.org/10.14716/ijtech.v9i2.1055

Susanto et al. 365 In India, Bhatt conducted an experimental study of several brands of household refrigerators, each with a capacity of 165 liters. The tests were performed on two types of household refrigerator: single door and double door, using refrigerant HCFC 22. The thermostat settings varied with normal and maximum levels. The results showed that Specific Energy Consumption (SEC) varied between 3.23 and 4.19 kwh/y/l for single door manual defrost refrigerators, and between 3.84 and 4.78 kwh/y/l for double door auto defrost models (Bhatt, 2001). kwh/y/l is the unit of annual energy consumption to refrigerator volume, explaining the Specific Energy Consumption conditions (SEC). As in the research conducted by Bhatt, the objective of this study is to experimentally analyze the impact of thermostat settings on increases of in household refrigerator energy consumption. Where the on-off compressor working time follows the temperature of the freezer set by the thermostat. As a refrigeration system component in the refrigerator that requires electrical energy. 2. METHODOLOGY The special room used for testing is called the chamber room. The temperature and Relative Humidity (RH) of this chamber room is controlled and the air flow rate in the room is not permitted to reach more than 0.25 m/s (BSNI, 2008). 2.1. Test Unit A two door household refrigerator type with a freezer space and fresh food compartment was used in the experiment. The specifications of the unit are shown in Table 1. Table 1 Technical specifications of refrigerator-freezer test unit Specifications Freezer cabinet capacity (liters) 95 Fresh food cabinet capacity (liters) 187 Power rating (Watts) 125 Current rating (A) 1.2 Voltage (V) 220 Frequency (Hz) 50 Climate class T Refrigerant type R600a 2.2. Test Condition In the test, the environmental temperature was kept constant at 25±0.5 o C and the relative humidity at 60±0.5%. The most important variable was the thermostat settings, which were set at points 1, 3 and 4 out of the maximum value of 7. The cooling load in the experiment used M- packages placed in the main space and in the freezer door, as shown in Table 2. 2.3. Instruments During the test, the door remained closed for the duration of the 48 hour test period. In order to measure the falling temperature in the cooling load (M-package) a T-type thermocouple is positioned in the center of the M-package. The experiment was performed in a room chamber with at a temperature of 25±0.5 o C. A T-type thermocouple was used to measure the temperature around the test unit and a humidity transmitter with ±10% accuracy was used to measure the relative humidity. Energy consumption was measured by using a digital YOKOGAWA WT-230 with an accuracy of ±0.0015 kw. A power meter was connected to a PC via RS-232 and LabView software used to save, analyze and display the data readings received on the PC monitor. A data logger was used

366 An Experimental Investigation into the Effect of Thermostat Settings on the Energy Consumption of Household Refrigerators to support direct measurements of temperature, relative humidity, DC voltage, AC voltage, DC current, AC current, frequency resistance and period. Table 2 Load calculation Position Package (kg) Quality (EA) Weight (kg) Top shelf 1 4 4 0.5 8 4 0.125 1 0.125 Bottom shelf 1 7 7 0.5 5 2.5 0.125 2 0.25 Door 1 0 0 0.5 6 3 0.125 6 0.75 Total (kg) 21.63 2.4. Experimental Setup A household refrigerator with a freezer at the top and a fresh food compartment at the bottom was used for this study. 2.4.1. Placement of humidity sensors and thermocouples Humidity sensors were placed inside the chamber room to measure the relative humidity around the refrigerator. Thermocouples were used to measure the temperature inside and outside the refrigerator. Several thermocouples were used, including three placed in the fresh food compartment. Each of the four thermocouples was inserted into the M-package in the freezer compartment and refrigerator door. Figure 1 Placement of thermocouples in fresh food compartment (TR) 2.4.2. Placement of load during test The cooling load used was an M-package, which has the same properties as lean meat. During the test process, the door remained closed. The M-package was inserted into the freezer and also the freezer door, as shown in Figures 2 and 3.

Susanto et al. 367 Figure 2 Position of thermocouples in M-package inside the freezer (TF) Figure 3 Position of thermocouples in M-package inside the freezer door (Door/Upper and Door/Lower) 3. RESULTS AND DISCUSSION The length of time required for the test was 240 hours for one data. The study was conducted with different thermostat setting variations, at points 1, 3 and 4; this only applied to the fresh food compartment. Meanwhile, the thermostat setting in the freezer was maintained at the maximum setting (7). The thermostat setting would determine the level of the temperature in the refrigerator, which would affect the increase in household refrigerator energy consumption. The humidity sensor only controlled the humidity in the test chamber, which should not exceed 75%, according to test standards. Figure 4 Temperatures in the freezer space The thermostat is an automatic switch to break the current into the compressor engine or reconnect when the cooling temperature begins to decrease and the compressor engine begins to

368 An Experimental Investigation into the Effect of Thermostat Settings on the Energy Consumption of Household Refrigerators restart. From Figure 4, it can be seen that when the thermostat was changed from point 1 to point 3, there was a very significant temperature drop, from -16.39 o C to -19.57 o C. This was due to the work of the compressor continuously electric current, impact of the open switch contact when the cooling temperature had not been reached. However, the change in temperature from point 3 to point 4 did not change significantly, only by 0.55 o C. Similarly, the temperatures in the refrigerator door can be seen in Figure 5. Figure 5 Temperatures in the freezer door Figure 6 Fresh food compartment temperatures The effect of the thermostat changes in the fresh food compartments shows a relatively similar trend. Each change in the thermostat caused a temperature drop of about 1 C; this can be seen in Figure 6. Increasing the value of the thermostat setting caused the temperature to fall, which increased the compressor work, so energy consumption also increased. Figure 7 shows how raising the thermostat affected energy consumption. This increased significantly when the thermostat setting was increased from point 1 to point 3. This increased energy consumption by 17.10%, or 0.599 kwh/day, and by 18.65% when the thermostat was turned up to point 4, or by 0.608 kwh/day. The resulting trend is the same as that of Masjuki

Susanto et al. 369 and Grimes (Grimes et al., 1977; Masjuki et al., 2001). The Masjuki test results show a temperature decrease from -4 C (position setting 1) to -13.3 C (position setting 4). Figure 7 Effect of energy consumption on regulated increases Figure 8 Temperature comparison in the freezer Figure 9 Temperature comparison in the fresh food compartment This study also compares the test results on the condition of the same refrigerator both volume and brand and mass M-package. The results can be seen in Figures 8 and 9, which show the

370 An Experimental Investigation into the Effect of Thermostat Settings on the Energy Consumption of Household Refrigerators differences, despite the fact that they have relatively similar tendencies. Many factors that lead to the measurement results are different, partly due to the preparation of unequal M packets. This had an impact on airflow blocks in different refrigerators, which caused uniform temperature conditions to become uneven. Temperature uniformity affects compressor work, as a component of energy consumption, so the difference in energy consumption is greater than 0.1 kwh/day. 4. CONCLUSION Based on the experiment, an increase in energy consumption of 0.175 kwh/day was obtained when the thermostat setting was increased from point 1 to point 3. There was also a slight increase in energy consumption of 0.016 kwh/day when this setting was increased from point 3 to point 4. With the thermostat setting change from point 3 to point 4, there was no significant change in energy consumption or drop in temperature, so it can be concluded that setting the thermostat to point 3 is sufficient to keep food fresh. While even testing the energy consumption of the same refrigerator is not necessarily the same result. 5. ACKNOWLEDGMENT The authors would like to thank the Directorate of Research and Community Service of the University of Indonesia through the "University of Indonesia Infrastructure Development Grants", under contract number 0219A/SK/R/UI/2012. 6. REFERENCES Bhatt, M.S., 2001. Domestic Refrigerators: Field Studies and Energy Efficiency Improvement. Journal of Scientitic & Industrial Research, Volume 60(7), pp. 591 600 EIA, 2015. Drivers of U.S. Household Energy Consumption, 1980 2009 Washington: U.S. Departemen of Energy Grimes, J.W., Mulroy, W., Shomaker, B.L., 1977. Effect of Usage Conditions on Household Refrigerator-freezer and Freezer Energy Consumption. ASHRAE Transactions, Volume 83(1), pp. 818 828 Hasanuzzaman, M., Saidur, R., Masjuki, H., 2011. Effects of Different Variables on Moisture Transfer of Household Refrigerator-freezer. Energy Education Science and Technology. Part A. Energy Science and Research, Volume 27(2), pp. 401 418 Hasanuzzaman, Md., Saidur, R., Masjuki, H.H., 2008. Investigation of Energy Consumption and Energy Saving of Refrigerator-freezer during Open and Closed Door Condition. Journal of Applied Sciences, Volume 8(10), pp. 1822 1831 Indonesia National Standard Organisation (BSNI), 2008. Refrigerator for Household Characteristics and Test Method Khan, Md.I.H., Afroz, H.M., Rohoman, M.A., Faruk, M., Salim, M., 2013. Effect of Different Operating Variables on Energy Consumption of Household Refrigerator. International Journal of Energy Engineering, Volume 3(4), pp. 144 150 Liu, D.-Y., Chang, W.-R., Lin, J.-Y. 2004. Performance Comparison with Effect of Door Opening on Variable and Fixed Frequency Refrigerators/freezers. Applied Thermal Engineering, Volume 24(14 15), pp. 2281 2292 Masjuki, H., Saidur, R., Choudhury, I., Mahlia, T., Ghani, A., Maleque, M., 2001. The Applicability of ISO Household Refrigerator freezer Energy Test Specifications in Malaysia. Energy, Volume 26(7), pp. 723 737 Saidur, R., Masjuki, H., Choudhury, I., 2002. Role of Ambient Temperature, Door Opening, Thermostat Setting Position and Their Combined Effect on Refrigerator-freezer Energy Consumption. Energy Conversion and Management, Volume 43(6), pp. 845 854

Susanto et al. 371 Sakalli, Ö., Kerpiççi, H., Kuddusi, L., 2017. A Study on Optimizing the Energy Consumption of a Cold Storage Cabinet. Applied Thermal Engineering, Volume 112, pp. 424 430