KUTERLEX & KUTERLEX PLUS PLASTIC COATED COPPER TUBE

Similar documents

YORKEX, KUTERLON & MINIBORE COPPER TUBE

Union coupling. copper x copper. Cone joint to BS 1010.

Technical Checklist - Plumbing and Heating Fittings - UK Sizes

FIRE PERFORMANCE CABLE

ENHANCED FIRE PERFORMANCE CABLE

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

Industrial Tubes. TECTUBE _cips, TECTUBE _med [GB] KME Germany GmbH & Co. KG

FIRE RESISTANT CABLES FP400

KSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR. Instructions for :- KSGD-01W/S Semi Conductor Standalone Refrigerant Leak Detector

High Performance LSZH Fire Resistant Cable

STANDARDS INSTALLATION. Certificate No 077m

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

SANCO. Once you've used SANCO you'll never use anything else. [GB] SANCO. KME Germany GmbH & Co. KG

FIRE RESISTANT CABLES FP200 GOLD

HEATING INVERTER DHC 6510R WELD PREHEATING AND STRESS RELIEVING

FIRE RESISTANT CABLES FP200 GOLD

Male elbow, copper x BSP taper male thread

Stormwater protection

Kenya s Official Distributor of GutterFlow Products

EN transition from BS 1387 Structural & Conveyance Business

PIPE MANUFACTURING CO.

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

INSTALL AN ELECTRIC SHOWER

Raychem Link Boxes. Cable Services Limited. Powering the UK

COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

BS /1000V XLPE Insulation LSZH Sheath Cables

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Pilkington energikare Advantage. Consumer Cleaning Guidelines

FIRE RESISTANT CABLES FP300

REG NO FM BS EN ISO HEADER TANK HEAT EXCHANGER. Installation, Operation & Maintenance Guide

Water Supply (Water Fittings) Regulations 1999

Data Sheet. Self regulating heating tapes. RS stock numbers

REG NO FM BS EN ISO EXHAUST GAS HEAT EXCHANGERS. Installation, Operation & Maintenance Guide

Data Sheet. Self regulating process heating tapes RS stock numbers ,

INDEX. page. page. page. page. page. page TALOS ACR COPPER TUBES ECUTHERM COPPER TUBES INNER GROOVED COPPER TUBES TALOS XS LINESETS ECUTHERM 2

Pilkington K Glass Range

4 liter Solo and 8 liter Combi

VERTICAL VONOVA & VERTICAL VONOPLAN. 20 VERTICAL VONOVA & VERTICAL VONOPLAN PANEL RADIATORS. VERTICAL VONOVA Type 20. VERTICAL VONOPLAN Type 20.

TeckNet LED05 LED Desk Lamp

For an indoor atmosphere that makes you feel good

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Flexible Gas Tubing. Semi-Rigid Corrugated Stainless Steel Tube System PRODUCT GUIDE.

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

Visqueen Vapour Control Tapes

Installing, modifying and maintaining domestic plumbing systems. Water Supply (Water Fittings) Regulations 1999

Guide to the Specification and Installation of Pyro Mi Wiring Cables

ENERGY /// UNDERGROUND DISTRIBUTION UNDERGROUND DISTRIBUTION MEDIUM AND LOW VOLTAGE POWER PRODUCTS

Unistrut Channel and Metal Framing Cable Tray Cable Ladder Cable Basket Pipe and Cable Clamps Electrical and Mechanical Solutions

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

ZoomLock TM Flame-Free Refrigerant Fittings

Testing coated fabrics

Condensing Units CUS 15-60

Product Data Sheet. Astro Strip

Pegler Yorkshire reserve the right to change specifications. 10 Year Guarantee Luxury Taps and Mixers

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

For more information on Pegler Yorkshire visit Heating Controls. Radiator valves with new integral push-fit inlet

Carbon Film Installation Instructions

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

Charcon British Standard kerb

CELT STAR C GAS-FIRED WATER HEATER. Category: I 2E+ Installation and Use Instructions. Contents : Description:

For further information please contact the Frigidaire Service Helpline on:

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Komo Thermostatic Bar Shower. Excluding Shower Kit

Installation, Operating and Servicing Instructions

WATER DESCALERS. Water Wizard Water Magic Water Heavy Duty Water Heavy Duty + OPERATION MANUAL.

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

Mini Tender Section 1.1 External Wall Insulation, Mechanical and Electrical Installation

IMPORTANT It is vital that the information in this leaflet, the user instructions and the appliance labels are carefully read and adhered to.

LSOH Flexible Cables

H Y D R O C O U R S E T R E N C H H E A T I N G

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

NEW NEW. Qual-PEX Crimp System. Plumbing and Heating Installation Manual SAFE. Over 45 ye ars serving the Irish Plumbing Industry.

Code Description Dimensions 4P1061 RUNE CP MONOBLOC DUALFLOW SINK MIXER see image. Operating Pressure (bar)

TEC Coolers. GEA Heat Exchangers. GEA Searle

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

Status Date Prepared Reviewed Endorsed Approved

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

Our Pedigree. Smart Systems is a member of the internationally renowned Aliplast Group.

Operating Instructions. Boilermag XL Filter. High Intensity Magnetic Separator

HYDRAULIC OIL COOLER. Installation, Operation & Maintenance Guide

Greenstar System Filter

Special Provision No. 683S28 December 2017

INTERNAL FRAMING PROFILES

Ensure nut and olive are in place before inserting pipe insert.

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

NOPHADRAIN RO O F DE C KS. The inverted roof, a sound construction for roof decks! GREEN ROOFS PODIUM ROOF DECKS PARKING ROOF DECKS

EarthLinked Series PHXTI Pool Heat Exchangers Installation Manual

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

Purge Ventilation Unit. Product Manual. ventilation systems TP625

This document is a preview generated by EVS

T6 - Centrally Connected & VONOPLAN T6.

Introduction.

VR60 GLASS FROSTERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR. VR60 Glass Froster. Series 1

HELKAMA. Optical Fibre Cables

Transcription:

KUTERLEX & KUTERLEX PLUS

KUTERLEX TO BS EN 13349 / BS EN 1057 Kuterlex - Straight tube range BS EN 13349 / BS EN 1057 15-28mm Half-hard (R250), 35-76.1mm Hard (R290) Available colours and lengths Pressure up to 65 C s per inner s per master (mm) (mm) 3m 5.8m 6m (Kg/m) (Kg/m) (bar) # (l/m) 5.8m/6m 15 x 0.7 1.0 0.280 0.05 58 0.145 10 100/240 22 x 0.9 1.0 0.531 0.07 51 0.321 10 100/150 22 x 1.2 1.0 0.698 0.07 69 0.302 10 100 28 x 0.9 1.0 0.682 0.08 40 0.539 5 50/90 28 x 1.2 1.0 0.899 0.08 55 0.515 5 100/150 35 x 1.2 1.5 1.134 0.16 51 0.835 5 50 35 x 1.5 1.5 1.405 0.16 65 0.804 5 50/100 42 x 1.2 1.5 1.369 0.19 42 1.232 5 50 42 x 1.5 1.5 1.699 0.19 54 1.195 5 50/75 54 x 1.2 1.5 1.772 0.24 33 2.091 3 30 54 x 2.0 1.5 2.908 0.24 56 1.964 3 30/45 66.7 x 1.2 2.0 2.198 0.40 26 3.248 1 10 76.1 x 1.5 2.0 3.129 0.45 29 4.197 1 10 01 02 BS EN 1057 Kuterlex is copper tube coated with a seamless plastics cover which protects the copper tube against aggressive materials. The Kuterlex cover eliminates time-consuming wrapping operations. It is also colour coded to identify the services carried in accordance with UK local authority specifications and BS 1710: 1984, Specification for identification of pipelines and services. Standard features TYPICAL APPLICATIONS Kuterlex - Coil range BS EN 13349 / BS EN 1057 Annealed (R220) Available colours and lengths Pressure up to 65 C Coils per pallet FM 00450 Cu-DHP grade copper` Manufactured in accordance with BS EN 13349 (specification for covered copper tube) Copper tube to BS EN 1057 BSi Kitemark licensed (copper tube) 25 year guarantee against product failure directly attributable to a manufacturing defect Straight lengths available in 5.8m lengths for container loads to export markets Cold water services Underground pipework, including contaminated ground Pipework behind plaster Design, installation and use All products should be designed, installed and used in accordance with appropriate specifications or codes of practice (e.g. BS 6700) and/or Yorkshire Copper technical recommendations. (mm) (mm) 10m 20m 25m 50m (Kg/m) (Kg/m) (bar) # (l/m) 8 x 0.6 1.0++ 0.124 0.04 66 0.036 40 30 10 x 0.7 1.0++ 0.182 0.07 62 0.058 50 40 20 15 x 1.0 1.0 0.391 0.05 67 0.133 35 22 x 1.2 1.0 0.698 0.07 57 0.302 25 # Based on tube in the supplied hardness All coverings made from LDPE except products marked ++, which are PVC BENEFITS Reduces installation time Protects the copper tube against aggressive materials Protects the copper tube against accidental damage and abrasion Plastic covering withstands water service temperatures up to 95 C remains flexible down to -60 C Colour coded for service identification: - Cold water services, green or blue - Gas services, yellow - General purpose, white

KUTERLEX PLUS TO BS EN 13349 / BS EN 1057 Kuterlex Plus - Straight tube range BS EN 13349 / BS EN 1057 15-28mm Half-hard (R250), 35-54mm Hard (R290) Available colours and lengths Pressure up to 65 C s per inner s per master (mm) (mm) 5.8m (Kg/m) (Kg/m) (bar) # (l/m) 5.8m 15 x 0.7 2.0 0.280 0.07 58 0.145 10 100 22 x 0.9 2.0 0.531 0.13 51 0.321 10 100 Kuterlex Plus - Coil range BS EN 13349 / BS EN 1057 Annealed (R220) Available colours and lengths Pressure up to 65 C Coils per pallet 03 04 BS EN 1057 Kuterlex Plus copper tube is sheathed in a continuous cover that has air channels on the internal surface. Kuterlex Plus is primarily designed to give the tube enhanced protection from external attack. In addition, the cover creates a thermal barrier which reduces heat loss from buried tube and condensation on exposed cold pipework. It has an insulation factor of 0.29 W/m/K. (mm) (mm) 25m (Kg/m) (Kg/m) (bar) # (l/m) 8 x 0.6 1.6++ 0.124 0.06 66 0.036 40 10 x 0.7 1.6++ 0.182 0.07 62 0.058 40 12 x 0.8 2.0 0.251 0.05 67 0.085 35 15 x 1.0 2.0 0.391 0.07 67 0.133 30 22 x 1.2 2.0 0.698 0.11 57 0.302 20 Standard features TYPICAL APPLICATIONS # Based on tube in the supplied hardness All coverings made from LDPE except products marked ++, which are PVC FM 00450 Cu-DHP grade copper Manufactured in accordance with BS EN 13349 (specification for covered copper tube) Copper tube to BS EN 1057 BSi Kitemark licensed (copper tube) Hot water systems Underground pipework, including contaminated ground Pipework installed in concrete Humid atmospheres 25 year guarantee against product failure directly attributable to a manufacturing defect Straight lengths available in 5.8m lengths for container loads to export markets Design, installation and use All products should be designed, installed and used in accordance with appropriate specifications or BENEFITS Reduces installation time codes of practice (e.g. BS 6700) and/or Yorkshire Copper technical recommendations. Protects the copper tube against aggressive materials Protects the copper tube against accidental damage and abrasion Plastic covering withstands water service temperatures up to 95 C remains flexible down to -60 C Reduces condensation on exposed pipework (see graph 1) Graph 1: Temperature at which condensation occurs on plain and Kuterlex Plus tubes Graph 2: Surface temperature of plain and Kuterlux Plus tubes in air Reduces surface temperature of the tube (see graph 2), thereby minimising the risk of burns or scalding Reduces noise level in exposed pipework Removes the need to paint exposed pipework

INSTALLATION GUIDE KUTERLEX AND KUTERLEX PLUS 1. Make circular incision in plastic cover. 2. Remove the cut plastic from the end of the tube. 3. Make the incision in plastic along tube. 4. Peel back the plastic cover carefully. 05 06 5. Secure the spliced plastic cover with tape. 6. Clean tube and fitting with a suitable abrasive pad. 7. Apply Flux. 8. Connect tube and fitting. 9. Wrap exposed plastic with a damp cloth. 10. Heat with blow lamp. 11. When cooled remove damp cloth and re-position plastic. 12. Secure with tape. 13. The finished joint. 14. Exposed ends should be sealed with tape. For full instructions please see technical manual.

KME YORKSHIRE LTD East Lancashire Road Kirkby Liverpool L33 7TU United Kingdom www.yct.com Sales Tel. +44 (0)151 545 5079 Fax. +44 (0)151 549 2139 sales@yct.com Technical Services Tel. +44 (0)151 545 5107 Fax. +44 (0)151 545 5018 technical@yct.com Disclaimer: KME Yorkshire Ltd operates a policy of continuous improvement of products and services. Every effort has been made to ensure that information contained in this brochure is accurate. However, KME Yorkshire Ltd does not accept any liability for any omissions or errors in the text. Produced by ICG www.icgonline.co.uk 92089/08.11