Guidance for Stationary Refrigeration & Air-Conditioning

Similar documents
General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

Information Guide Maintenance and Refrigerant Regulations. Issue 35

EC Regulation No 842/2006 on certain fluorinated greenhouse gases

FACT SHEET 9 Large Air-Conditioning (air-to-air)

FACT SHEET 6 Transport Refrigeration

Legislation & Standards

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Meeting the Challenges of the EU HFC Phase-Down

4: Leakage matters: for service and maintenance contractors

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

CHAPTER 1 INTRODUCTION

Retrofitting Existing Systems

Reducing Refrigerant Leakage

market trend update on industrial & light-commercial refrigeration

Guidance Note EC Regulation No 842/2006 on Certain Fluorinated Greenhouse Gases. BFPSA Guidance for the Fire Protection Industry

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

REFRIGERANT PROCEDURE

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

The natural solution for domestic refrigeration

Natural refrigerants - naturally efficient

Natural refrigerant trends in EU, Japan & North America

Safety standards relevant to Refrigeration, Air-Conditioning and Heat Pump equipment

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

International New Technology and Refrigerant Symposium

Clean, Silent and Efficient Refrigeration Solutions for Distribution and City Operations

Sustainable refrigeration

Stakeholder Meeting Dublin, Ireland Update on the new F-Gas Rules Andrea Voigt, EPEE

European Experience in Certification of competence in ODS substitutes: F-gas and Alternative Refrigerants. Pune, 5 th March 2015

ISHRAE. Guideline document to ISO Version 1 Feb Indian Society of Heating, Refrigerating and Air Conditioning Engineers

Chapter 2. Alternatives to HCFCs and their Characteristics

The impact of legislation and trends for the industry

Refrigerants & Cooling in renovation buildings

Alternative Refrigerants Part 1 Future and Current Options. Overview

Low GWP alternative refrigerants to R404A

investment in R&D, the commitment to - name.

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Description of the European standard EN 378: Refrigerating systems and heat pumps Safety and environmental requirements

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

The Problem of Counterfeit Refrigerants

Flammability and the Low GWP Refrigerant Challenge

From the Field to the Supermarket

Mitsubishi Electric Guide to Chiller Technologies. Information Guide 58

Natural Refrigerants.

Refrigerant Leak Detection Solutions

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

New Refrigerants & Selecting Capital Equipment

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

Exhibition Hall 1. Fachprogramm. Technical Programme

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - OEMs, Europe. Over

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Actions to Control Emission of HFCs in Japan

HFCs or the Old Refrigerants - what is the best Choice?

Ammonia. Background on ammonia as a refrigerant

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Responsible Care Product Stewardship for Refrigerants

PHASE-IN of natural refrigerants. Prof. Dr. Armin Hafner NTNU Norway

BRA FACT FINDER Number 19

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Walk-in Coolers & Freezers - OEMs, North America. Over

ON SUBSTANCES THAT DEPLETE

Overview of New Refrigerants and Expected Market Trends

Guided Learning Hours (GLH) 4 Invigilated Assessment (IA) 1 Total Qualification Time (5)

Trends and Perspectives in Supermarket Refrigeration

Comparison Ammonia / Secondary Refrigerant System against Direct Evaporation of HCFCs /HFCs

Brazed Plate Heat Exchanger for CO Applications

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Hall 7A. Chillventa Specialist Forums 2018 Chillventa Fachforen NürnbergMesse, Arbeitstitel, Datum 1

The cold chain in the fishery sector. Refrigeration Technology Review

Refrigerant and Energy Regulations Update

CHAPTER 1 INTRODUCTION

Chillers for High Ambient Conditions: What Technologies and Fluids?

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

natural refrigerants - global trends & developments

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Stay in business: STOP installing R-404A / R-507A! R-404A R-507A

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

Hydrocarbon heat and refrigeration supply systems for a mini-hotel with a shop and laundry

Information for practitioners 5. Refrigerant selection guidelines. An overview of the refrigerants of the future.

Requirements for the Collection, Transportation, Storage and Treatment of Cooling and Freezing Appliances containing Hydrocarbons (HC)

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

ARE YOU AN AUTHORISED REFRIGERATION GAS PRACTITIONER?

Possibilities of the RAC sector transformation a technical perspective

The Industry s Most Complete Refrigeration Source

Overview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol

DuPont ISCEON 9 Series Refrigerants

PACKAGED REFRIGERATION EQUIPMENT

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

Refrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies

Challenges from flammability concerns and related safety standards, possibilities for compact systems limiting charge sizes

Hydrocarbons as refrigerants

Navigating a changing refrigerants market

Ecoguide for choosing your professional refrigerator. Ecoguide. for choosing your professional refrigerator

INSTALLED BANK OF REFRIGERANT

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Be sustainable while protecting your business

ABSTRACT. 2 CanmetENERGY

Transcription:

Information Sheet RAC 2 - Usage Guidance for Stationary Refrigeration & Air-Conditioning This Information Sheet provides background information about the use of stationary refrigeration, airconditioning and heat pump equipment (RAC systems) in organisations across Great Britain. We provide a description of the types of refrigerants used, describe key end user markets and discuss sources of emissions and options for reducing emissions through improved containment or use of alternative refrigerants (more information on alternatives in provided in Information Sheet RAC 7). 1. Types of Refrigerants Many organisations are major users of refrigerants that are affected by both the EC F gas and Ozone Regulations. The following table lists the most common refrigerants used and shows which Regulations are relevant to each. A more comprehensive list of refrigerants is available in Information Sheet GEN 2. Refrigerant Type EC F Gas Regulation EC Ozone Regulation R22 HCFC R408A HCFC + HFC Blend R134a HFC R404A HFC Blend R407C HFC Blend R410A HFC Blend Ammonia Natural CO 2 Natural 2. Use of RAC Systems by Companies Many organisations use RAC systems and this section describes some of the various uses by different sectors across Great Britain. Users of RAC systems will need to comply with the various obligations described in Information Sheet RAC 3. 2.1. Food Retail The key RAC system applications are as follows: Retail display cabinets with pack systems Retail display cabinets are used for chilled and frozen food, via central pack systems. In large supermarkets these usually contain well above 100 kg of refrigerant in each system and some are above the 300 kg threshold requiring automatic leak detection to be fitted. The packs often serve back of store cold rooms as well as the retail displays. Most central pack systems use either HFCs (often R404A) or HCFCs (often R22). Systems of this type will be affected by many of the obligations in the F gas or Ozone Regulations. Retail display cabinets with condensing units In smaller stores it is common to find display cabinets connected to a remote condensing unit. These are smaller than pack systems, but are usually above the 3 kg threshold for regular leak testing and record keeping. RAC 2, Usage, last updated 16 June 2009 Page 1 of 6

Integral retail display systems Retail cabinets are sometimes fitted with integral refrigeration, where the whole refrigeration system is built in to the cabinet (in the same way that a domestic refrigerator is configured). These are sometimes used alongside displays connected to a central pack e.g. for a branded product or a special display. Integral systems will usually be well below the 3 kg threshold, so are not subject to all the obligations. However, the rules on refrigerant recovery and use of qualified personnel still apply to small systems. Retail Store Air-conditioning systems Most retail stores also use air-conditioning systems in public areas of the store. Whilst these are usually much smaller than the central pack refrigeration systems they will often be well above the 3 kg threshold. Non-HFC systems A few companies have trialled central systems using either ammonia or hydrocarbon refrigerants, in conjunction with a secondary refrigerant. These systems are not in widespread use, but do not fall under the F gas or Ozone Regulations if no fluorinated gases (F gases) or Ozone Depleting Substances (ODS) are used. This also applies to recent installations using CO 2 as a refrigerant. Distribution depot refrigeration Regional distribution centres have large cold and chill stores. The use of ammonia is quite common in such installations and CO 2 is sometimes used. However, some depots use R22, which falls under the EC Ozone Regulations and some use HFC blends such as R404A, which falls under the EC F gas Regulation. 2.2. Buildings Office air-conditioning All private and public sector organisations need to consider their use of refrigerants in RAC systems in the office buildings they occupy when undertaking their overall F gas and ODS assessments. Many office air-conditioning systems use ODS refrigerants (such as R22) or F gas refrigerants (such as R410A and R407C). These may be in the form of small split systems or larger chilled water systems. Retail centres air-conditioning systems Retail centres, such as shopping malls and outlet centres, will have air-conditioning such as small split systems and large, central systems - often using a chilled water secondary system (e.g. in centrally controlled parts of a shopping centre). Many systems use HFC refrigerants, and older ones might use HCFCs. Retail stores air-conditioning systems Large, non-food retail stores also have air-conditioning systems similar to those of retail centres - such as small split systems and large, central systems (e.g. in department stores). Small, nonfood retail stores, such as high street shops and smaller chains, may use some refrigeration and air conditioning in small systems. Many systems use HFC refrigerants, and older ones might use HCFCs. Hospitals, health centres and nursing homes (multiple systems) Hospitals are important users of refrigeration and air-conditioning equipment, due to both their size and some of the functions they need to perform. Typical cooling applications in a hospital may include general air-conditioning (for staff offices and wards), specialist air-conditioning (for operating theatres or IT/communications rooms), equipment cooling (e.g. for X-ray machines), general refrigeration (for mortuary rooms and canteen catering) and specialist refrigeration (for vaccine and tissue stores and cryogenic applications). Smaller sites, like health centres and RAC 2, Usage, last updated 16 June 2009 Page 2 of 6

nursing homes, may also have air conditioning. All these applications make widespread use of equipment that contains HFC or HCFC refrigerants which fall within the requirements of the EC F gas and Ozone Regulations. School and University air-conditioning and refrigeration There is relatively little use of F gases in most schools. However, there may be some airconditioning installed in larger modern schools and it is more likely to be found in universities, especially in large buildings. Also most schools and universities will have refrigeration systems for catering facilities and within universities there will be some specialist uses of refrigeration and air conditioning, particularly in laboratories, such as chilled rooms. Most systems use either HFCs or HCFCs. 2.3. Manufacturing Food and Drink Many food & drink manufacturing facilities rely heavily on refrigeration to cool and store products. Key sectors include meat, poultry and fish processing, chilled and frozen foods, confectionary, dairy, brewing and cold stores. A wide variety of equipment is used ranging from small cold rooms to very large freezing systems. HCFC 22 is still in common use and HFCs such as R134a and R404A are widely used. Some larger systems use ammonia. Chemical Some chemical processes are required to operate below ambient temperatures and others are exothermic and require heat removal. Gas liquefaction, vapour condensation and maintenance of reaction temperatures are all important examples of the requirement to avoid excessive temperatures via refrigeration systems. This industry sector possesses some very complex refrigeration systems employing a variety of refrigerants including both HCFC and HFCs. Electronics In the production of electronic components the maintaining very specific temperature and humidity conditions are crucial. The maintenance of optimum manufacturing environments relies on the use of large air-conditioning systems. Engineering Refrigeration is used in various engineering applications, such as mould cooling. It may also be required for machine cooling (e.g. hydraulic power packs). Generally, it is used where the process temperature required would be lower than that capable of being achieved by the use of cooling water or air-blast cooling. 3. Sources of F Gas and ODS Emissions There are four main sources of F gas or ODS emissions from RAC systems: 1) Gradual leakage during normal operation. There are many potential leak locations, especially on larger systems that have numerous joints, valves and compressors. If leakage is slow it can go unnoticed for long periods and result in direct emissions of F gases or ODS and poor refrigeration plant performance which often leads to wasted energy. 2) Catastrophic leakage during normal operation. It is not uncommon for a major failure to occur and for a system to lose all refrigerant in a short time period, e.g. a refrigerant pipe burst. On a large system this can lead to a significant loss of refrigerant. RAC2, Usage, last updated 16 June 2009 Page 3 of 6

3) Emission during plant maintenance. If a refrigeration plant component needs to be replaced during maintenance it may be necessary to remove some or all of the refrigerant from the system. Some years ago refrigerant was simply vented to the atmosphere. This is now illegal. To avoid refrigerant loss during maintenance it is vital that personnel have suitable recovery equipment and are properly trained in accordance with the requirements set out in the relevant Regulations. 4) Emissions at end of plant life. It is vital to properly recover refrigerant from older plants during decommissioning, using recovery equipment and appropriately trained personnel. 4. Options for Reducing F Gas and ODS Emissions Complying with the EC F gas and Ozone Regulations will help reduce greenhouse gas emissions. Refrigerant leakage is costly in both financial and environmental terms it makes sense to address the leakage problem. To achieve the lowest possible loss of refrigerant an organisation should consider taking the following steps: 4.1. Only purchase plant that is leak tight There is a lot that can be done at the design stage to minimise leakage. The key is to design the pipework carefully (to avoid stress related failures) and to use connections that remain leak free in all modes of operation. This approach does require attention to detail and may involve a small amount of extra capital cost. However, the extra investment will pay-off if the plant remains free of leaks. Designing the plant to hold the minimum quantity of refrigerant reduces the loss in the case of a catastrophic leak. Ensure that personnel are appropriately qualified to install equipment minimum qualifications apply for both installation, servicing and maintenance of F gas containing equipment, see RAC 5 for details. 4.2. Ensure regular leak checks and take action to repair leaks Both the F gas and Ozone Regulations set down minimum requirements on leak testing that are a key obligation. Make sure that leaks are repaired promptly and properly by appropriately certificated personnel. See Information Sheet RAC 3 for details on frequency of leak testing. 4.3. Address the rogue plants It is quite common to find that the 80/20 rule applies i.e. that 80% of annual leakage comes from only 20% of the refrigeration systems. It is therefore advisable to identify your rogue plants and spend more effort on them to ensure that problem components are replaced and that leaks are reduced. It is suggested that you increase the leak test frequency on these plants until the problems are solved. 4.4. Ensure you maintain complete records Data, such as rate of leakage and the cause of previous leaks, makes management of leakage problems easier and more effective. For advice on keeping records see Information Sheet RAC 7. 5. Dealing with Phase Out of R22 If you are using R22 or another HCFC refrigerant (see Information Sheet GEN 2 for more information of refrigerant fluids) then you need to consider a plan for phase out in addition to ensuring low levels of leakage from existing plants. The phase out of HCFCs for refrigeration applications will occur in two steps: Virgin HCFC phase out: After 31 st December 2009 you cannot use virgin HCFCs for plant maintenance (even if you bought the fluid before this date). You will be allowed to use recycled HCFCs, but there is no guarantee that supplies will be available at a reasonable price. Recycled HCFC phase out: After 31 st December 2014 you cannot use recycled HCFCs for plant maintenance. RAC 2, Usage, last updated 16 June 2009 Page 4 of 6

The best phase-out option depends on the age and efficiency of existing equipment. If your plant is old, unreliable or inefficient it is best to consider plant replacement. If the plant still has some years of useful life then it may be possible to retrofill with a drop-in replacement refrigerant. Your 3 main options are to: 1) Replace the whole plant with a new system. This is the most expensive option, but enables you to minimise leakage and maximise energy efficiency. 2) Change the refrigerant to a suitable alternative. This is much cheaper than a new plant, but you will still have to make additional investment to ensure leakage is minimised and reliability and efficiency maximised. 3) Delay a decision until nearer the 2014 final phase-out date. This is initially the easiest option, but it is only delaying the decision and it is a high risk strategy, as recycled R22 might be in short supply. 6. Alternative Refrigerants for RAC Systems The ideal way of reducing F gas or ODS emissions to zero is to use an alternative refrigerant, such as CO 2, ammonia or hydrocarbons. These three refrigerant types have all been used in RAC Systems. However, before you invest you must take care that your alternative design is cost effective and has the lowest overall carbon footprint. Refrigeration plants give rise to two main types of greenhouse gas emissions: Firstly: Direct emissions of refrigerants such as F gases through leakage. Secondly: Indirect emissions of CO 2 from the power station supplying the plant with electricity. For most refrigeration plants it is the energy related CO 2 emission that is the dominant part of the overall carbon footprint. Hence, it is essential that a system with an alternative refrigerant is equal to or better than an HFC system in terms of energy efficiency. A brief summary of the advantages and disadvantages of each refrigerant type is shown below. Refrigerant Advantages Disadvantages HFC Ammonia CO 2 Hydrocarbon Widely used Non-toxic and nonflammable Zero GWP Zero GWP (net) Good potential for heat recovery Good potential for energy efficiency Low GWP High GWP (Global Warming Potential). Equipment containing HFCs has historically had high levels of leakage; however this is not an intrinsic characteristic of the refrigerant. Highly toxic and flammable. Must be used with secondary refrigerant, which can lead to poor efficiency. Operates at very high pressure. Little practical experience in service companies. Additional costs associated with energy efficiency optimisation. Highly flammable. Must be used with secondary refrigerant, which can lead to poor efficiency. The brief section here on alternatives is supplemented by Information Sheet RAC 7 which provides a fuller discussion about the subject of alternatives. RAC2, Usage, last updated 16 June 2009 Page 5 of 6

7. Energy Efficiency In many organisations RAC Systems can account for a significant percentage of the total energy costs. The steps necessary for compliance with the EC F gas and ODS Regulations provide an ideal opportunity to assess the energy efficiency of your RAC systems. If HCFC systems have to be replaced or retrofitted, this is particularly important. Typical issues to consider are: Load reduction (e.g. better time and temperature controls); Plant operating conditions (e.g. reduce head pressures); Secondary loads (e.g. chilled water pumps); Part-load operation (e.g. compressor controls and variable speed drives). For further guidance, see the Carbon Trust website and guides such as GIL120 - Air conditioning Fact Sheet. 7.1. Energy Performance in Buildings Directive (EPBD) 2002/91/EC The EPDB calls for regular inspection of heat pumps and of air-conditioning systems of an effective combined rated output of more than 12 kw in buildings. These inspections must include an assessment of the air-conditioning efficiency and the sizing compared to the cooling requirements of the building. The accredited expert inspecting the systems must provide appropriate advice to the users on the alternative solutions and the possible improvements or replacement of the air-conditioning system. How to Contact F-Gas Support: Telephone Help Line: 0161 874 3663 Website: www.defra.gov.uk/fgas Email: fgas-support@enviros.com Post: F-Gas Support, P O Box 481, Salford, M50 3UD This document has been prepared by F-Gas Support; the information provided is intended as guidance and must not be taken as formal legal advice nor as a definitive statement of the law. Ultimately only the courts can decide on legal questions and matters of legal interpretation. If you have continuing concerns you should seek legal advice from your own lawyers. F-Gas Support is a Government funded team set up to help organisations understand their obligations under the EU Fluorinated Greenhouse Gases and Ozone Regulations. F-Gas Support is also working with Regulators to promote compliance. It is being run on behalf of Defra and the devolved administrations by the Local Authorities Coordinators of Regulatory Services (LACORS) and Enviros. RAC 2, Usage, last updated 16 June 2009 Page 6 of 6