EN aquatech.piovan.com

Similar documents
Customers. The core of our innovation. Feeding&Conveying Drying Dosing Temperature Control Refrigeration. Granulation

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS

The next level of energy efficiency and flexibility

GENERAL INFORMATIONS

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Torad Rotary Spool Compressor

HVAC Water chiller selection and optimisation of operation

BVG series Biogas and landfill gas applications

DAIKIN Modular Inverter Air Cooled Chiller

ARV.

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Air Cooled Scroll Chiller

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Heat pump & cooling unit in one

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Kelvin air conditioning. KELVIN Clim W280. Cooling Capacity: 280 ~ 1840 kw

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Refrigeration dryers with Energy Saving Impulse Technology and Thermal Mass 0,3-27,0 m³/min Purifying your compressed air, increasing your efficiency.

Midea VFD Centrifugal Chiller Technology

OIL-FREE COMPRESSOR. Let s write together a new chapter in the refrigeration history.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

Vacuum Pump Vacuum Pump

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

Air cooled industrial chillers

500 EX Fusion Compressor Series

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

THE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS. MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium

DC Inverter Smart VRF Products(R410A)

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

DX SERIES DIRECT EXPANSION ENERGY SAVING AIR DRYER

Why to decide on a Rotorcomp compact unit screw compressor

ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit

Chillers. Technical Data. EWYD-BZ 250~580 kw

Variable Refrigerant Flow (VRF) Systems

DEi COMPRESSED AIR & GAS TREATMENT. Purifying your compressed air, increasing your efficiency.

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

ACMVTECH HIGH EFFICIENCY UNITARY AHU

Environmentally friendly refrigeration systems for industrial use

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

turb new unico turbo frigo turbo fl Liquid chiller equipped with magnetic levitation twostage centrifugal compressors RCGROUP SpA C_GNR_0711

Energy saving refrigeration dryers SCFM. Purifying your compressed air, increasing your efficiency.

Air Cooled Scroll Chiller

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Variable Refrigerant Flow

PRODUCT GUIDE

Spiralair SPR 2-30 TECHNOLOGY YOU CAN TRUST

H4T R410A. refrigerant

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Industrial cooling systems LT

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

Conditioning your ambient, maximising your comfort.

ECOPlus SERIES OF HIGH-PRESSURE METERING MACHINES

.2 Section Waste Management and Disposal.

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

CVGF. Water Cooled Centrifugal Chillers

Integrated VarIable refrigerant flow ahu/pau (r410a)

Powerful and reliable. Also for high ambient temperatures. weco Compact chillers

RIGID DC LIQUID CHILLER

PREVIEW COPY. Compressors. Table of Contents. Introduction to Compressors...3. Lesson Two Reciprocating Compressors...21

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

APS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

refrigeration drying solutions

Technical Information

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

CO2 TRANSCRITICAL BOOSTER SYSTEMS

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder.

AMONUM chillers. Eco-friendly cooling in compact packaging, easy maintenance and safe. Optimal use of energies. engie-refrigeration.

$42,000. Danfoss Turbocor Compressors Give INTERTECH PLASTICS A RESHORING ADVANTAGE. saved annually

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Performance Data ADSORPTION CHILLER AGGREGATES & SYSTEM COMPONENTS

MACH N-407 Heat Pump Air-Cooled Chiller

The Refrigeration Cycle. Jerry Cohen President Jacco & Assoc.

CSM hp. Oil-injected screw Compressors Belt driven. The perfect solution for the small businesses. TECHNOLOGY YOU CAN TRUST

Chapter 4 Compressors Overview & System Annual Power Consumption

Select watercooled scroll chiller or remote condenser scroll chiller. and build up a chilled water station adding modules.

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

1

A Design for True Performance and Energy Savings In Refrigerated Compressed Air Dryers The Digital Scroll Dryer

KELVIN Clim F497. Kelvin air conditioning

The High-efficiency Water-cooled Chiller "H series"

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

High-Performance, High-Reliability Gas Heat Pump

50A KP 70A KP 90A KP 120A KP 150A KP 210A

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Transcription:

EN aquatech.piovan.com

Refrigeration Technologies: scroll-compressor chillers The scroll compressor is the most suitable component for the small and medium duty requirements in the industrial applications. Combining up to 6 scroll-compressors within one or more circuits, is possible to cover a wide range of cooling capacities. Water, Air, Remote Air cooled chillers available. 2_Refrigeration

SCROLL COMPRESSORS of Aquatech COOLING AIR/WATER Working principle This hermetic unit is mainly composed by a compression chamber, one fix scroll plus one orbiting scroll, the electrical motor and the shaft connected to the lubrication pump. 100 % 50 % 0 % Off Off EXPANSION VALVE Variation of Thermal Load with 2 or 4 scroll compressors CONDENSER 2 Compressors: 4 Compressors: Time 100 % 75 % 50 % 25 % 0 % EVAPORATOR Off * Off Off PROCESS WATER Off Off * Off Off * Time * Energy saved using 4 compressors instead of 2. Reliability The easy and robust design lead this technology to be among the most reliable today available in the market. Low sensitiveness to liquid hammer. Efficiency Reduced energy utilization: up to 3 compressors within one refrigerant circuit. Stable water temperature during partial loads (most part of working time): the Aquatech multi-scroll range is composed by solution with 1 to 6 compressors in the same unit assuring high adaptability to the working conditions. Flexibility Optimized for partial-load functioning: multi-scroll or close control function. Suitable for a wide range of refrigerants. Wide applications range (process water or ambient temperature). Temperature Stability with 2 or 4 scroll compressors SET +1 C SET SET -1 C time Time 4 compressors: variation within +/-0.5 C 2 compressors: variation within +/-1 C _3

Refrigeration Technologies: screw-compressor chillers The screw-compressor chillers allow to cover the medium and high duty requirements in the industrial applications. Water, Air, Remote Air cooled chillers available. 4_Refrigeration

Working principle Rotary screw compressors utilize two helical screws to compress the refrigerant. Lubricating oil fulfil the space between the screws, both providing a hydraulic seal and transferring mechanical energy between the driving and driven rotor. Gas enters at the suction side and moves through the threads as the screws rotate. Clearances between the threads decrease and compress the gas. The gas exits at the end of the screws. of Aquatech screw-compressor chillers (a) Screw compressor (b) Screw compressor chiller by Aquatech Unit with cooling capacity of 2.8MW and COP 5.3 Reliability: up to 4 independent refrigerant circuits guarantee a continuous functioning. The semi-hermetic case allows internal maintenance to the compressor. Efficiency: Reduced energy utilization: innovative design of the screws. High efficiency shell-andtube evaporator. Temperature stability and energy usage optimization: standard electronic expansion valve. Developed for optimal functioning with green refrigerant R134a. - Flexibility: Stepless regulation of the cooling capacity from 25% to 100%. _5

Refrigeration Technologies: inverter driven chillers This range of chillers adopts state-of-the-art cooling devices to reach the highest performance in terms of efficiency, accuracy and reliability. Water, Air, Remote Air cooled chillers available. 6_Refrigeration

COP Ambient effect on COP and cooling power Aquatech inverter driven chiller Vs conventional unit working conditions: Cooling water [ C] 12/7 C chilled water 50 Hz frequency Working principle INVERTER TECHNOLOGY works on the principle of variable compressor motor speed; an electrical signal is given to the compressor motor to adjust the screw speed according to the thermal load. If the thermal load is high the compressor runs faster developing a higher refrigerant flow rate and accordingly increasing the cooling power; on the contrary, the inverter reduces the refrigerant flow rate reducing the cooling power supplied consequently. Cooling power [kw] COP Aquatech inverter driven chiller COP conventional chiller CoolingPower [kw] 95% of working time is under 30 C (existing installation in Southern Europe) of Aquatech inverter driven chillers 1-Reliability and efficiency in temperature control: highest COP with any ambient conditions. - Fans managed by frequency converter ensure high efficiency and low noise level. - Sub cooler increases refrigeration capacity and efficiency. - EEV electronic expansion valve, for the accurate control of the lamination phase of the refrigerant gas. Lowest water temperature fluctuation: +/- 0.3 C at evaporator outlet. - Oil flow switch to assure compressor is running in safe conditions. 2-Easy to install and to maintain. Total annual energy consumption Aquatech inverter driven chiller Vs conventional system 3-Compact and suitable also for outdoor installation (no room required inside the production plant). Electrical consumption [MWh] 4-Designed to operate at low condensation pressure to increase the efficiency, especially at partial loads. 5-Extended compressor life and reduced energy utilization: screw compressor is managed by frequency converter. Piovan Aquatech inverter driven chiller - Total consumption Conventional system - Total - Total consumption Ambient temperature [ C] Required cooling capacity: 400 kw existing installation in Southern Europe _7

thermorefrigerators The new Aquatech Thermorefrigera - and blow moulding machines. This technology ensures the process, providing water to every All models are equipped with digital scroll compressors which have the feature of working continuously, thanks to the possibility to modulate their functioning from 10 to 100% step by step. 8_

Working principle The Digital Scroll compressors operate with the principle of engaging the compressor mechanism (scrolls) at intervals, while the motor runs constantly. The variable capacity is so obtained. Lift Piston Assembly Bleed Hole Solenoid Valve Modulation Chamber Spring Benefits of Aquatech thermorefrigerators Significant reduction of energy consumption. The combination of compressors with digital technology and the electronic expansion valve ensures the greatest energy efficiency. Moreover, the exclusive Aquatech solution which does not require an internal recirculating pump further increases energy savings. Maximum operational flexibility of the working cell. Ideal solution whenever it is necessary to manage the demands of different temperatures of every single processing machine, with no waste. Reduced running costs, thanks to the possibility to use the freecooling system which permits to provide water coming from the dry cooler or the cooling tower. Reliability and long life of the unit: the possibility of power modulation from 10 to 100% allows the compressor to function continuously, thus eliminating the risk of breakdowns and ensuring long duration of the motor. - Ultra-compact design: small floor dimension, reduced height. - Complete respect of the environmental concerns, with the choice of the R410a gas, according to the EU legislation. _9

Free Cooling systems Free cooling is a method of using low external air temperatures to assist in chilling water for industrial process. When the ambient air temperature drops to a set temperature, a modulating valve allows all or part of the chilled water the system installed, to assure maximum efficiency and the optimal utilization of energy, allowing to save all costs for refrigeration when external temperature is low enough. Aquatech free-cooling technologies 1. Dry cooler Water Temperature = Ambient Temperature + 5 C 2. Dry cooler with sprinklers Water Temperature = Ambient Temperature + 2 C 3. High performance dry cooler Water Temperature = Ambient Temperature - 5 C 3. High performance dry cooler 10_

991H083 MODIFICATION RESERVED_AQUATECH SRL Aquatech Srl Via Galileo Galilei 3 30036 Santa Maria di Sala Venezia Italy Tel. +39 041 5799111 Fax +39 041 487436 info@aquatech.piovan.com aquatech.piovan.com