Superdryer Dehumidifiers

Similar documents
Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

IW-25-2 Dehumidifier Installation & Operations. Manual

WatchDog NXT60. Installation and Operations Manual. Seaira Global, LLC NC Highway 50 Surf City, NC (910)

Registrate by scanning. Storm Ultra. Add:Florida USA

Registrate by scanning

DEHUMIDIFIERS FDK54 USE AND MAINTENACE MANUAL

Registrate by scanning. Add: North Carolina USA

Seaira Global LLC NC Highway 50 Surf City, NC

AlorAir Solutions INC Add: Shoemaker Ave,Cerritos,CA90703 Tel:

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Zeus Extreme Owner's Manual

GL-DEH Series Portable Dehumidifier Operating Instructions

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

Registrate by scanning. Add: North Carolina USA

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Portable Dehumidifier

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

DEHUMIDIFIERS. SuperDry 125. Installation and Operations Manual. WhiteWing Dehumidifiers. P: Add: 300 E Valley Drive, Bristol, VA 24201

EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Portable Dehumidifier with Internal Pump

CS90H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

AlorAir Solutions INC

USER AND MAINTENANCE MANUAL

Horizontal Bottle Cooler Installation and Operation Manual

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Cleanshield HEPA 550 Owner's Manual

READ AND SAVE THESE INSTRUCTIONS. Air Boss Model T5200 Custom Packaged Electronic Air Cleaner. TRION

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

Instruction Manual. 4.6 Cu. Ft. Refrigerator/Freezer. Wards.com Wards.com The solution for your cold-storage needs!

Portable Dehumidifier with Internal Pump Portable Dehumidifier with Internal Pump OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS

Ice Cream Freezer Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

InstructIon Manual KrEs EQuIPMEnt stands

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

5) Do not start or stop the unit by inserting or pulling out the power plug.

Model 1870F Dehumidifier Installation and Operating Manual

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

CS90E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Refrigerator Freezer Installation and Operation Manual

INSTRUCTIONN MANUAL. for Angle Curved MMF9106 MMF9109 MMF9112

OPERATING INSTRUCTIONS

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

OWN ER'SGUIDE READ AND SAVE THESE INSTRUCTIONS

NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

All about the Use &Care

FTC-350A. ual. Instruction and Operation Manual. Thermo NESLAB Manual P/N Rev. 11/08/00

OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Model 1850F Dehumidifier Installation and Operating Manual

USER MANUAL. Bottled Water Dispenser SAVE FOR FUTURE USE. Model #

All about the Use &Care

VP17A BUNN OPERATING & SERVICE MANUAL

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Industrial Dehumidifier Operating Instructions. Model: VG 1500

PORTABLE DEHUMIDIFIER

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

Glass Door Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

FROST FREE REFRIGERATOR INSTRUCTION MANUAL

Refrigerator Freezer Installation and Operation Manual

DEHUMIDIFIER. User Manual 50BT, 70BT

EBAC MODEL PD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

RPI Industries, Inc.

BD80 / BD80-XE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

INSTALLATION AND OPERATION MANUAL

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

User Manual / Installation Instructions

Installation & Operation Manual Ice Cream Freezers

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

12,000 BTU Evaporative Portable Air Conditioner

SLIDER CASEMENT AIR CONDITIONER

DEHUMIDIFIER DESHUMIDIFICATEUR DESHUMIDIFICADOR

30-pint Dehumidifier User Guide

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions


CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

K100P DEHUMIDIFIER OWNER S MANUAL

Utopian Portable Dehumidifier

Quest 105, Dry155, and 205 Dual

AIR CONDITIONER ELECTRONIC CONTROL

RPI Industries, Inc.

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

Transcription:

Superdryer Dehumidifiers Installation and Operations Manual Read and Save These Instructions Distributed Exclusively By: Air Cleaning Equipment, Inc. Broadway, NC 27505 Phone: 919-258-3330 www.aircleaningequipment.com Manufactured by: Superdryer 62 Owner s Manual 1

Safety Notes: The Superdryer Series Dehumidifier must always be connected using the grounded electrical connection as required from all electrical appliances. The warranty is voided and all responsibility for the operation is born by the owner if non-grounded wiring is utilized. The Superdryer Dehumidifiers must only be maintained and serviced by a qualified technician. The Superdryer Dehumidifiers are designed to be transported and operated in the vertical position. Any other orientation could cause water to come in contact with the electrical components. Remove plug before moving dehumidifier. If any water may have spread throughout unit, the unit should be opened and allowed to dry thoroughly before reconnected to electric and restarting. For proper operation, neither the inlet nor discharge should be positioned against a wall. The inlet requires a minimum of 12 clearance and the discharge needs a minimum of 48 clearance. If the unit is utilized in a narrow room, the unit should be positioned so that the inlet and discharge are facing the longest straight runs. Do not insert any objects into the inlet or discharge. If service is required, call a qualified technician. All work on unit should be done with the unit off and unplugged. Do not use water to clean unit exterior. Only use a damp cloth with unit unplugged. Do not use unit as shelf or device to hang clothes. This could cause damage to unit. The inlet filter generally needs cleaned once per month. Check unit on a weekly basis to insure that more frequent cleaning is not required. Pertinent Technical Standards and Regulations: The Superdryer dehumidifier has been designed and manufactured to all the following European Standards (Norms) and Regulations: MACHINES NORMS (D.P.R., NR. 459-24 th July 1996) ; SECURITY REGULATIONS FOR LOW TENSION APPLIANCES 2006/95/CE); ELECTROMAGNETIC COMPATIBILITY (EMC) 2004/108/CE. It is hereby certified that this Dehumidifier conform to the: IEC Regulations CEI-EN 60335-2-40, CEI-EN 55014-1, 55014-2. The machine is built according to RoHS European Norms Superdryer 62 Owner s Manual 2

Identification: For future reference, write down the model, serial number, date of purchase and use this information whenever corresponding concerning your dehumidifier. Model Number Superdryer 62 Serial Number Date of Purchase Customer Service: For additional questions concerning the operation of your dehumidifier, please: Contact your installing contractor Please call ACE at 919-258-3330 Email: sales@aircleaningequipment.com Warning 120 Volts AC may cause serious injury from electric shock. 1. Disconnect electrical power before servicing or moving 2. Plug unit only into grounded electrical outlet 3. Do not use extension cord 4. Do not use plug adapter Power Supply: Outlet Requirement: Circuit Protector: 115V, 60 Hz, Single Phase 3-Prong 15 Amp Time Delay Fuse or Circuit Breaker Principle of Operation The Superdryer Series Dehumidifier utilizes its integral humidistat to monitor the conditioned space. When the relative humidity goes above the selected set point, the dehumidifier will energize. Air is drawn across an evaporator coil. The evaporator coil is cooler than the dew point of the air so moisture will condense out of the air (below 70 F you will actually see ice forming on the evaporator coil). Air is then reheated through the condenser coil and distributed back into the room. Superdryer 62 Owner s Manual 3

Reference: (Fig. 1/2), Dehumidistat (7) starts the functioning of the dehumidifier when the humidity is higher than the preset level. Air is drawn in through the filter (1) flows through the aluminium refrigerated coil/ evaporator (2), through the heat exchanger/ condenser (3). Finally, the motor fan (4) expels the air back into the room through the front grilled panel. The condensed water is collected in the tank (5). A micro-switch (6) stops the machine when the water in the tank reaches the correct level activating the full circuit. An electronic circuit (8) controls the defrosting and prevents the compressor (9) from short cycling. Fig. 1 Machines with water reservoir Fig. 2 Machines with condensate pump Unit Set-Up The unit will only function properly in a closed area. All windows and doors must be closed to allow drying to occur. WARNING: It is recommended to remove dehumidifier from area if applying a liquid vapor barrier. Some coatings dry via solvent evaporation, which can be harmful to certain components in your dehumidifier. Allow coating to completely dry and exhaust vapors prior to positioning dehumidifier. Read and follow coating manufacturer s instructions completely. Place dehumidifier on level surface WARNING If during handling, the dehumidifier is moved in such a manner that the compressor didn t remain in a vertical orientation, wait a minimum of 2 hours before turning the unit on. Route drain line (3/4 ID tubing on gravity drain, 3/8 ID tubing on units with condensate pump) to drain or outside of the area. Note: On units with gravity drain, Drain line must have a downward slope to drain. (Not applicable to units with reservoirs) Superdryer 62 Owner s Manual 4

Plug unit into 15 amp grounded outlet. To operate unit, turn humidistat knob clockwise until unit energizes. o Unit will run fan only for approximately 2 minutes and than compressor will energize. o Confirm compressor is running and allow to run for minimum of 15 minutes If under 70 F, a layer of ice will form on evaporator coil If over 70 F, a layer of frost or water droplets will form on coil After you ve confirmed satisfactory operation of unit, humidistat should be set at desired position for automatic operation. Position of Dehumidistat Knob 1 2 3 4 5 Approximate Room Setpoint 70% 60% 48% 35% 25% Relative Humidity In OFF the machine will never start In CONT the machine will never stop NOTE: Humidistat settings are approximate only. For critical applications, you may want to confirm actual settings with a psychrometer and adjust according. Display Panel Indications: Power Indication: Red light illuminates when unit is plugged into outlet Full Indication: Green light illuminates when either water tank is full or condensate pump is not working properly. When light is on, unit will be in off condition. Defrost Indication: Red light illuminates during initial soft-start or any normal defrost cycle. Working Indication: Red light illuminates (together with Power light) when machine is operating in normal dehumidification mode. Superdryer 62 Owner s Manual 5

Operation During normal operation, the dehumidifier will automatically cycle on and off to maintain your desired set point. If it should need to run for extended periods of time, the dehumidifier features an automatic defrost cycle to melt any ice that accumulates on evaporator coil. Approximately every 35 minutes of continuous operation, the unit will test for the need for a defrost cycle. If required, it will defrost for approximately 3 minutes. Warning: Never apply an external source of heat to melt ice off coil. Maintenance Annual Inspection of Coils and drain line is required. 1. Unplug Unit 2. Filter may be cleaned by a. Vacuuming b. Washing with warm, soapy water. Rinse and shake dry. 3. Coils may be cleaned by a. Vacuuming the external surfaces of coil b. Blowing compressed air from behind coils. Hold air nozzle 6 away from coil to avoid damage. Warning: Do not steam clean refrigerant coils. 4. Plug in Unit 5. Test Refrigerant Charge a. Confirm compressor is running and allow to run for minimum of 15 minutes i. If under 70 F, a layer of ice will form on evaporator coils ii. If over 70 F, a layer of frost or water droplets will form on coil 6. Test Defrost System a. Leave unit running for approximately 35 minutes (45-55 minutes). The unit should enter a defrost mode for approximately 3 minutes. The unit will run fan only for a period of time and then check the temperature of the coil. If necessary, the unit will enter a defrost mode with the compressor operating and fan off to defrost the coil If the unit will not defrost, either i. Control board may be defective ii. Bypass valve may be defective 7. After routine maintenance has been completed, return humidistat to desired setting. 8. When you are ready to move unit, depress button on condensate pump (while unit is on ) to drain condensate or empty water tank prior to moving. This will prevent water from splashing on inside of unit. If any problems occur during routine maintenance, contact your contractor or the factory. Superdryer 62 Owner s Manual 6

Specifications: MODEL Superdryer 62 HEIGHT 21 WIDTH 21 LENGTH 36 WEIGHT AIRFLOW MOISTURE REMOVAL AT 80F/60% RH POWER SUPPLY FINISH OPERATING RANGE 102.00 LBS 360 CFM 65 PINTS PER DAY 115 VOLT/60 HERTZ SINGLE PHASE POWDER-COATED EPOXY 33 F TO 90 F REFRIGERANT R-22 CONDENSATE DRAIN SIZE AMPS (FULL LOAD) AT 80F/60% POWER CORD 3/8 Tube on Pump 5.8 FLA 20 GROUNDED PLUG FILTER SIZE 13.5 x 12 Troubleshooting: 1. Unit will not operate a. Insure unit is plugged in and red power lamp is illuminated b. Insure humidistat is set to high enough level to operate. c. If unit plugged in and red power lamp is off, check fuse or breaker for outlet to make sure power is getting to unit 2. If green full light is on a. On units with reservoir, insure reservoir is empty and properly placed back in unit to allow operation b. On units with condensate pump, check that drain line is not blocked preventing pump from discharging water to drain. Superdryer 62 Owner s Manual 7

Warranty Seller warrants the equipment to be free from defects in workmanship and material for a period of 12 months after shipment (36 months on compressor). This warranty is limited, however, to the repair or replacement of defective equipment, which is returned, freight prepaid, to the Seller s factory. This limited warranty does not apply to any part or component that is damaged in transit or when handling, has been subject to misuse, has not been installed, operated or serviced according to the Seller s instructions, or has been operated beyond the factory-rated capacity or has been altered in any way. Routine maintenance is not covered by this warranty. Seller s liability is limited to replacement of defective parts or components and does not include any cost of labor (including, but not limited to, labor to remove and/or reinstall any defective part). ACE/Fral shall not be responsible for loss of use of any product, loss of time, inconvenience, or damage to other equipment, or any other indirect or consequential damage with respect to property whether as a result of breach of warranty, neglect, or otherwise. THE WARRANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, IN LAW OR IN FACT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE. The foregoing shall constitute the total liability of seller in the case of defective performance of all or any of the equipment or services provided to Buyer. Buyer agrees to accept and hereby accepts the foregoing as the sole and exclusive remedy for any breach or alleged breach of warranty by Seller. Superdryer 62 Owner s Manual 8