C E R T I F I C A T E O F C O M P L I A N C E

Similar documents
C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

UL CERTIFICATES OF COMPLIANCE

4-Wire Photoelectric Duct Smoke Detector-D4240

UROX.S911 - Smoke-automatic Fire Detectors. Smoke-automatic Fire Detectors

CERTIFICATE OF COMPLIANCE

Cooper Fire Systems. UL Listed Range

Full Service Central Station Fire Alarm Listing Evaluation

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

Installation Instructions

REPORT ON DISCUSSIONS DURING UL MEETINGS WITH ELECTRICAL INSPECTORS AT THE 2003 IAEI 75 th JUBILEE MEETING

BY-LAW AMENDING THE BY-LAW CONCERNING THE SERVICE DE SÉCURITÉ INCENDIE DE MONTRÉAL (RCG )

UL Resources for Code Officials and Design Professionals. Presented by: Bruce E. Johnson Senior Regulatory Engineer, UL

UL Resources for Code Officials

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Venting Gas-fired Appliances. Doors, Windows, and Related Hardware

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL

SMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS

Acoustical Surfaces, Inc.

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC

TrueAlarm Smoke Detectors

Idaho Surveying & Rating Bureau, Inc South Cobalt Point Way Tel: (208) Meridian, Idaho FAX: (208)

i-p65 is a high specification competitively priced emergency LED bulkhead utilising the latest LED and optic

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

FLASHLIGHT ANSI STANDARDS

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Textures 3D

Report of Surface Burning Characteristics Test on Acoustical Panel

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

Fire and Security Specification

Micropoint 2. Horizon Centre, Torbay Hospital Micropoint 2

Fire Systems Design Pocket Guide BS 5839 Part 1:2017 and CoP 0001 for Visual Alarm Devices. Fire Installers Mate. A guide to fire system design

FIRE ALARM APPLICATION CITY OF MADISON HEIGHTS

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Railtech Ltd.

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

Duct Smoke Detector - D4120

Fire Resistant Cables - Update Alan Cavers Engineering Manager Certificate Services Group

Energy Storage Systems Fire Safety Considerations. Howard Hopper, FPE Regulatory Services Program Manager

TrueAlarm ES Analog Sensing

Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd

CORRELATION OF USE MARKING AND PRODUCT IDENTITY TEXT FOR NEW TYPE R LISTING MARKS

UL Online Certifications Directory

Linergy II. England and Wales Cricket Board, Truro Linergy

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today.

Bold items are particular to the City of Euless

A. This Section includes the following lighting control devices:

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering

Code of Practice for the Management of Overhead Corridor Ducts in the Main Building.

DUCT SMOKE DETECTOR D4120

Report Of Surface Burning Characteristics Tests On PVC Sheeting As Submitted By Jain (Americas) Inc.

Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC)

NFPA 72 Code Changes vs 2013

Installation and user manual for the BiWire / Conventional Repeater Panel

Frequently Asked Smoke Alarm Questions

MFES READY Make your home fire safe. Home Smoke Alarms

CANADIAN FIRE ALARM ASSOCIATION An Update on Standards, Technologies and Solutions. Smoke Characterization Study

Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International

Directory of Listed Products

UL Online Certifications Directory

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

F, T, L and W Ratings - What are the Code & Testing Requirements?

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

3/6/2018. Design Tips For Fire and Smoke Barriers. Professional Development Hours (PDH) Certificates. Copyright Materials

Fire Safety Evaluation of Existing Manufactured Educational Building Covered by Section 423 of the Florida Building Code

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

J-PRO TM Cable Support System

Chapter 17, Initiating Devices

File EX CA March 31, 2010 REPORT RESIDENTIAL SPRINKLERS. Viking Corp Hastings, MI. Copyright 2010 Underwriters Laboratories Inc.

Smoke & Carbon Monoxide

SECTION : FIRE ALARM & DETECTION SYSTEMS

Melrose Fire Department

UEE30811 Q-Tracker Work Tasks

1 of 4 10/26/2015 1:58 PM. Committee Input No NFPA [ Section No ]

Reshaping Duct Smoke Detection

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Australian Standard. Automatic fire detection and alarm systems System design, installation, and commissioning AS

Nfpa 90a Free Wordpress

THE BASICS OF FIRE ALARM PLAN REVIEW

Stellar Panelboard Dimming Systems

DERRY FIRE DEPARTMENT LISTED AGENT CERTIFICATION PROGRAM

FIRE & LIFE SAFTEY STANDARD

File EX3836 Project 05CA54707 Project 06NK13655 Project 06NK29644 Project 06NK25809 Project 08CA19260 Project 07NK04786 Project 08CA42763 REPORT

Intelligent Detection Devices

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we

2018 NICET Code Transition Changes

Louvers & Dampers April Product Guide Specification SECTION COMBINATION FIRE SMOKE DAMPERS

AN ANALYSIS OF THE PERFORMANCE OF RESIDENTIAL SMOKE DETECTION TECHNOLOGIES UTILIZING THE CONCEPT OF RELATIVE TIME

SECTION FIRE ALARM SYSTEMS

FORZA FORNI 601 N Main St, Brewster, NY

ZERTI ~CERTIFICAJE. Certificate holder. Product tested. Manufacturer. Type designation. Codes and standards forming the basis of testing

Menvier Fire System MF9300

Reshaping Duct Smoke Detection

Standard for tests for flammability of plastic materials for parts in devices and appliances

UNIVERSITY OF RICHMOND HOUSING FIRE SAFETY POLICY

Transcription:

20120109 S24246 Report Reference S24246-2007 October 15 Issued to: This is to certify that representative samples of COOPER SAFETY WHEATLEY HALL RD DONCASTER SOUTH YORKSHIRE, DN2 4NB UNITED KINGDOM Heat-automatic Fire Detectors Heat detector, conventional, 2-wire, combination electronic fixed temperature and rate-of-rise type, Models UCHR-2W and UCHRI-2W. Heat detector, conventional, 2-wire, electronic fixed temperature type, Models UCHT-2W and UCHTI-2W. (See following page for additional model information.) Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: Additional Information: ANSI/UL 521, "Heat Detectors for Fire Protective Signaling Systems." See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Listing Mark should be considered as being covered by UL's Listing and Follow-Up Service. The UL Listing Mark generally includes the following elements: the symbol UL in a circle: with the word LISTED ; a control number (may be alphanumeric) assigned by UL; and the product category name (product identifier) as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product. Page 1 of 2

20120109 S24246 Report Reference S24246-2007 October 15 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Model No. Type Compatibility Restrictions Contact Arrangement Temp Range ( F) Smooth Ceiling Spacing (Ft) to Wall or Partition UCHR-2W FT/ROR D2-135 50 25 UCHRI-2W FT/ROR D2-194 50 25 UCHT-2W FT D2-135 50 25 UCHTI-2W FT D2-194 50 24 D2 - For connection to Listed control units with which compatibility was determined by test or a review of circuit parameters. Interconnection and compatible models indicated on installation wiring diagram for detector (base) and/or control unit. FT/ROR - Fixed temperature/rate of rise combination FT - Fixed temperature Page 2 of 2

Report Reference S24205-2007 October 16 Issued to: This is to certify that representative samples of COOPER SAFETY WHEATLEY HALL RD DONCASTER SOUTH YORKSHIRE, DN2 4NB UNITED KINGDOM Smoke-automatic Fire Detectors & Heatautomatic Fire Detectors Fire Alarm Subassembly: Smoke detector, conventional, 2-wire, photoelectric, Model UCPT-2W. Complementary Listed as a fixed temperature heat detector. (See following page for additional model information.) Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: Additional Information: ANSI/UL 268A, "Smoke Detectors for Duct Application" and ANSI/UL 521, "Heat Detectors for Fire Protective Signaling Systems." See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Listing Mark should be considered as being covered by UL's Listing and Follow-Up Service. The UL Listing Mark generally includes the following elements: the symbol UL in a circle: with the word LISTED ; a control number (may be alphanumeric) assigned by UL; and the product category name (product identifier) as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product. Page 1 of 2

Report Reference S24205-2007 October 16 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Smoke-automatic Fire Detectors Detector Compatibility Velocity Range (fpm) Model Application Type Restrictions Min Max UCPT-2W(a) OAP P(IHD) D2 0 300 a - Complimentary Listed (UQGS, File S24205) as a Heat-Automatic Fire Detector. Page 2 of 2

Report Reference S24205-2007 October 15 Issued to: This is to certify that representative samples of COOPER SAFETY WHEATLEY HALL RD DONCASTER SOUTH YORKSHIRE, DN2 4NB UNITED KINGDOM Smoke-automatic Fire Detectors Smoke detector, conventional, 2-wire, photoelectric, Model UCPD-2W. (See following page for additional model information.) Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: ANSI/UL 268A, "Smoke Detectors for Duct Application." Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Listing Mark should be considered as being covered by UL's Listing and Follow-Up Service. The UL Listing Mark generally includes the following elements: the symbol UL in a circle: with the word LISTED ; a control number (may be alphanumeric) assigned by UL; and the product category name (product identifier) as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product. Page 1 of 2

Report Reference S24205-2007 October 15 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Smoke-automatic Fire Detectors Detector Compatibility Velocity Range (fpm) Model Application Type Restrictions Min Max UCPD-2W OAP P(IHD) D2 0 300 Page 2 of 2