Installation and maintenance

Similar documents
HOME. Installation and maintenance instructions. Installation and maintenance instructions. For the competent person GB, IE COMBI

Installation and maintenance

ecofit pure Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE

ecofit pure Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE

ecofit pure Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE

Operating instructions

Operating instructions

Installation and maintenance

ecotec plus Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE

Operating instructions

Operating instructions

ecotec plus Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VU GB 656/4-5 A

aurostor Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VIH S GB...

Nitron Condense Nitron Condense 28 (H-TR)

ecocraft exclusive Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE

ecotec pro Operating instructions Operating instructions For the operator GB, IE Gas-fired wall-hung high-efficiency boiler

ecotec pro Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VUW

ecotec plus boiler user guide

Installation and maintenance instructions. For the competent person. Installation and maintenance instructions. ecotec plus. VU 80, 100, 120 kw GB, IE

ecotec plus Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VUI

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

ecotec plus Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VU, VUW

Operating instructions

Operating instructions

Operating instructions. For the operator. Operating instructions. ecotec. Gas fired wall hung high efficiency boiler.

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

flexotherm exclusive Installation and maintenance instructions Installation and maintenance instructions For the competent person

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

/2010 US/CA

Operating instructions

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Mikrofill Ethos Condensing combination boiler

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

Installation and maintenance instructions

Tankless Water Heater

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

Gas Instantaneous Water Heater

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

USER GUIDE VOGUE MAX SYSTEM

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Residential Gas Hybrid Water Heater

User s Information Manual

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

USER GUIDE LOGIC HEAT H

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification

ecotec GB, IE Instructions for installation and servicing Wall hung room sealed fan assisted condensing boiler For the installer

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Operating Instructions

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Universal Fire Tube Boiler Wall Mount Models

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

USER'S INFORMATION MANUAL

User s Information Manual

WHE 2.24 / WHE 2.24 FF

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

atmocraft VK 654/9-1654/9 DE/AT/GB/CZ/SK/HU/PL/HR/SI/SCG

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

GB24 & GB30. User Manual

Instructions for installation and use English. More documents on: H B /09

User s Information Manual

Standards of Training in Safe Gas Work Domestic Natural Gas Training Specification

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

Installation and maintenance instructions

User s Information Manual

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

USERS MANUAL FOR GAS BOILERS

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Gas Fire Patio Heater Q9

24V dc Terminals X4. 230Vac Terminals X V dc Electrical connections Volt free Room thermostat on/off

ir-range 8G /03.15 Changes reserved.

ecotec Instructions for installation and servicing Wall hung room sealed fan assisted condensing boiler For the installer

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

Powerflow Unvented water heater

Logic+ Combi

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

User s Information Manual

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

For the owner. Operating manual. ecotec. Gas wall boilers with condensing appliance technology VU 466/4 VU 656/4

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

User s Information Manual

Drying Cabinet Installation and Operating Manual

DIGITAL MODULATING BOILERS

User s Information Manual

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

ecotec exclusive GB, IE Installation and maintenance instructions

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

Bosch 80% AFUE Gas Furnace BGS80 Model

User s Information Manual

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

Transcription:

The energy you need Installation and maintenance instructions Ultimate 0c 5c G, IE

Contents Contents Safety... 4. ction-related warnings... 4. Risk caused by inadequate qualifications... 4. Intended use... 4.4 General safety information... 4.5 Regulations (directives, laws, standards)... 6 Notes on the documentation... 7. Observing other applicable documents... 7. Storing documents... 7. pplicability of the instructions... 7 Product description... 7. Serial number... 7. Information on the identification plate... 7. Functional elements: Combination unit... 8.4 CE label... 8 4 Installation... 8 4. Transporting the unit... 8 4. Unpacking the product... 8 4. Checking the scope of delivery... 8 4.4 Dimensions... 9 4.5 Minimum clearances... 9 4.6 Clearance from combustible components... 9 4.7 Using the installation template... 9 4.8 Wall-mounting the product... 9 4.9 Removing/installing the front casing... 0 4.0 Removing/installing the side section... 0 5 Installation... 0 5. Checking the gas meter... 5. Gas and water connections... 5. Connecting the drain line for the expansion relief valve... 5.4 Connecting the condensate drain pipework... 5.5 Connecting the drain cock... 5.6 flue gas installation... 5.7 Electrical installation... 6 Operation... 5 6. Using diagnostics codes... 5 6. Displaying the status codes... 5 6. Using check programmes... 6 7 Start-up... 6 7. Carrying out the initial start-up... 6 7. Checking the factory setting... 6 7. Checking and treating the heating water/filling and supplementary water... 6 7.4 voiding danger arising from insufficient water pressure... 7 7.5 Switching on the product... 8 7.6 Filling and purging the heating installation... 8 7.7 Filling the condensate siphon... 8 7.8 Filling the hot water circuit... 8 7.9 Checking and adjusting the gas settings... 8 7.0 Checking function and leak-tightness... 0 8 dapting the unit to the heating installation... 0 8. urner anti-cycling time... 0 8. Setting the pump output... 8. Setting the bypass... 9 djusting the hot water temperature... 9. Setting the hot water temperature... 0 Handing the product over to the operator... Inspection and maintenance.... Observing inspection and maintenance intervals.... Procuring spare parts.... Checking the CO₂ content....4 Setting the CO₂ content....5 Removing the gas-air mixture unit....6 Cleaning the heat exchanger....7 Checking the burner... 4.8 Checking the ignition electrode... 4.9 Cleaning the condensate tray... 4.0 Cleaning the condensate siphon... 4. Cleaning the filter in the cold water inlet... 5. Cleaning the heating filter... 5. Installing the gas-air mixture unit... 5.4 Draining the product... 5.5 Checking the pre-charge pressure of the expansion vessel... 5.6 Completing inspection and maintenance work... 5 Troubleshooting... 5. Rectifying faults... 5. Calling up the fault memory... 6. Deleting the fault memory... 6.4 Resetting parameters to factory settings... 6.5 Preparing the repair work... 6.6 Replacing defective components... 6.7 Completing repair work... 9 Decommissioning the product... 9 4 Customer service... 9 ppendix... 0 Check programmes Overview... 0 Overview of diagnostics codes... 0 C Status codes Overview... 4 D Overview of fault codes... 5 E Connection diagram: Combination unit... 8 F Connection diagram: Combination unit (5 kw)... 9 G Inspection and maintenance work Overview... 40 H Opening in the air/flue pipe... 4 H. Positioning of the opening of a fan-supported flue gas pipe... 4 H. Text from S 5440- on fan-supported flue gas pipes... 4 H. Opening of the flue pipe below eaves and balconies... 4 I Commissioning Checklist... 4 Installation and maintenance instructions Ultimate 0000675_0

Contents J Combustion chart... 46 K Lengths of the air/flue pipe... 47 L Technical data... 47 Index... 50 0000675_0 Ultimate Installation and maintenance instructions

Safety Safety. ction-related warnings Classification of action-related warnings The action-related warnings are classified in accordance with the severity of the possible danger using the following warning signs and signal words: Warning symbols and signal words Danger! Imminent danger to life or risk of severe personal injury Danger! Risk of death from electric shock Warning. Risk of minor personal injury Caution. Risk of material or environmental damage. Risk caused by inadequate qualifications ssembly and disassembly, installation, startup, maintenance, repairs and decommissioning must only be carried out by a competent person who is sufficiently qualified to observe all of the instructions that come with the product, to proceed in accordance with the current state of the art, and to comply with all applicable directives, standards, laws and other regulations.. Intended use There is a risk of injury or death to the user or others, or of damage to the product and other property in the event of improper use or use for which it is not intended. The product is intended as a heat generator for closed central heating installations and for hot water generation. The products referred to in these instructions must only be installed and operated in conjunction with the flue pipe accessories listed in other applicable documents. Exceptions: For C6 and P installation types, follow the specifications in these instructions. Intended use includes the following: observance of accompanying operating, installation and servicing instructions for the product and any other system components installing and fitting the product in accordance with the product and system approval compliance with all inspection and maintenance conditions listed in the instructions. Intended use also covers installation in accordance with the IP class. ny other use that is not specified in these instructions, or use beyond that specified in this document shall be considered improper use. ny direct commercial or industrial use is also deemed to be improper. Caution. Improper use of any kind is prohibited..4 General safety information.4. Risk of death from escaping gas What to do if you smell gas in the building: void rooms that smell of gas. If possible, open doors and windows fully and ensure adequate ventilation. Do not use naked flames (e.g. lighters, matches). Do not smoke. Do not use any electrical switches, mains plugs, doorbells, telephones or other communication systems in the building. If it is safe to do so, close the emergency control valve or the main isolator. If possible, close the gas isolator cock on the product. Warn other occupants in the building by yelling or banging on doors or walls. Leave the building immediately and ensure that others do not enter the building. Notify the gas supply company or National Grid Transco +44 (0) 800 999 by telephone from outside of the building..4. Risk of death from escaping flue gas If you operate the product with an empty condensate siphon, flue gas may escape into the room air. 4 Installation and maintenance instructions Ultimate 0000675_0

Safety In order to operate the product, ensure that the condensate siphon is always full..4. Risk of death due to blocked or leaking flue gas routes Installation errors, damage, tampering, unauthorised installation sites or similar can cause flue gas to escape and result in a risk of poisoning. What to do if you smell flue gas in the property: Open all accessible doors and windows fully to provide ventilation. Switch off the product. Check the flue gas routes in the product and the flue gas diversions..4.4 Risk of death due to explosive and flammable materials Do not use or store explosive or flammable materials (e.g. petrol, paper, paint) in the installation room of the product..4.5 Risk of death from electric shock There is a risk of death from electric shock if you touch live components. efore commencing work on the product: Unplug the mains plug. Or disconnect the product from the power supply by switching off all power supplies (electrical partition with a contact opening of at least mm, e.g. fuse or line protection switch). Secure against being switched back on again. Wait for at least minutes until the condensers have discharged..4.6 Risk of death due to lack of safety devices The schematic drawings included in this document do not show all safety devices required for correct installation. Install the necessary safety devices in the system. Observe the applicable national and international laws, standards and guidelines..4.7 Risk of poisoning and burns caused by escaping hot flue gases Only operate the product if the air/flue pipe has been completely installed. With the exception of short periods for testing purposes, only operate the product when the front casing is installed and closed..4.8 Risk of being burned or scalded by hot components Only carry out work on these components once they have cooled down..4.9 Risk of injury during transport due to a high product weight. Make sure that the product is transported by at least two people..4.0 Risk of corrosion damage due to unsuitable combustion and room air Sprays, solvents, chlorinated cleaning agents, paint, adhesives, ammonia compounds, dust or similar substances may lead to corrosion on the product and in the air/flue pipe. Ensure that the supply of combustion air is always free of fluorine, chlorine, sulphur, dust, etc. Ensure that no chemical substances are stored at the installation site. Ensure that the combustion air is not routed through chimneys which have previously been used with floor-standing oil-fired boilers, or with other boilers, which could cause soot to build up in the chimney. If you are installing the product in hairdressing salons, painter's or joiner's workshops, cleaning businesses or similar locations, choose a separate installation room in which a combustion air supply is ensured that is technically free of chemical substances..4. Risk of material damage caused by frost Do not install the product in rooms prone to frost. 0000675_0 Ultimate Installation and maintenance instructions 5

Safety.4. Risk of material damage caused by using an unsuitable tool Use the correct tool to tighten or loosen screw connections..5 Regulations (directives, laws, standards) Observe the national regulations, standards, guidelines and laws. 6 Installation and maintenance instructions Ultimate 0000675_0

Notes on the documentation Notes on the documentation. Observing other applicable documents You must observe all the operating and installation instructions included with the system components.. Storing documents Pass these instructions and all other applicable documents on to the system operator.. pplicability of the instructions These instructions apply only to: Product article number rticle number Gas Council Number ULTIMTE 0c 000064 47-09-5 ULTIMTE 5c 000065 47-09-6 These products are only designed for natural gas systems. Product description. Serial number Information on the identification plate Serial number Ultimate H, G0-0 mbar ( kpa) Cat. Condensing technology Type: Xx(x) PMS PMW V/Hz W IP Meaning For quality control purposes; rd and 4th digits = year of production For quality control purposes; 5th and 6th digits = week of production For identification purposes; 7th to 6th digits = product article number For quality control purposes; 7th to 0th digits = place of manufacture Product description Factory setting for type of gas and gas connection pressure pproved gas category Efficiency class of the boiler in accordance with EC Directive 9/4/EEC Permissible flue gas connections Maximum water pressure in heating mode Maximum water pressure in hot water handling mode Electric connection Max. electrical power consumption Level of protection Heating mode Hot water generation Pn P Qn Qnw T max. Nominal heat output range in heating mode Nominal heat output range in hot water handling mode Nominal heating load range in heating mode Nominal heating load range in hot water handling mode Max. flow temperature The serial number is located on the identification plate () and in the short operating instructions () ( Page 7). Stickers showing the serial number are on the back of the electronics box ().. Information on the identification plate The identification plate is mounted on the underside of the product in the factory. The identification plate keeps record of the country in which the product is to be installed. NOx Code (DSN) GC no. NOx class for the product Specific product code "CE label" section Read the instructions. "Recycling and disposal" section Gas council number Information on the identification plate Meaning arcode with serial number 0000675_0 Ultimate Installation and maintenance instructions 7

4 Installation. Functional elements: Combination unit 4 Installation 0 4. Transporting the unit Important: With regard to the regulations of 99 concerning the manual handling of loads, the unit exceeds the weight that can be lifted by a single person. 9 8 7 6 5 4 4 5 6 4.. General Hold the load as close as possible to your body. void rotational movements. Instead, reposition your feet. If the unit is being lifted by two persons, ensure your movements are coordinated during lifting. void bending your upper body do not lean forwards or to the side. Wear suitable non-slip protective gloves in order to protect your hands against sharp edges. Ensure that you are carrying the load securely. If required, get somebody to assist you in this. 4.. Unloading the box from the delivery van It is recommended that two people lift the unit together. Lift the box using the straps provided. Use safe lifting techniques keep your back straight and bend your legs at the knee. Hold the load as close as possible to your body. If the unit is being lifted by two persons, ensure your movements are coordinated during lifting. If required, get somebody to assist you in this. 0 9 8 7 4. Unpacking the product Electronics box Heating circuit expansion relief valve Plate heat exchanger 4 Condensate siphon 5 Pressure gauge 6 Flue pipe 7 Pressure sensor 8 Flue gas analysis point 9 Ignition transformer 0 Gas valve.4 CE label ir intake pipe Ignition electrode Fan 4 Primary heat exchanger 5 Heating expansion vessel 6 Volume flow sensor 7 Heating pump 8 ypass 9 -way valve 0 Filling cock. Remove the product from its box.. Remove the protective film from all of the product's components. 4. Checking the scope of delivery Check that the scope of delivery is complete. Quantity Description Heat generator ag with accessories ag with seals Condensate drain hose Drain spigot of the expansion relief valve Installation template Hanging bracket ag containing the hydraulic connections Enclosed documentation The CE label shows that the products comply with the basic requirements of the applicable directives as stated on the identification plate. The declaration of conformity can be viewed at the manufacturer's site. 8 Installation and maintenance instructions Ultimate 0000675_0

Installation 4 4.4 Dimensions 4.6 Clearance from combustible components It is not necessary to maintain a clearance between the product and components made of combustible materials. 4.7 Using the installation template Use the installation template to ascertain the locations at which you need to drill holes and make breakthroughs. 4.8 Wall-mounting the product. Check whether the wall has sufficient load-bearing capacity to bear the weight of the product under operating conditions (operational weight).. Wall-mount the product as described using the adapted fixing material provided on-site. Conditions: The load-bearing capacity of the wall is sufficient, The fixing material may be used for the wall C D Dimensions C D 740 mm 0 mm 00 mm 48 mm 4.5 Minimum clearances Wall-mount the product as described. Conditions: The load-bearing capacity of the wall is not sufficient Ensure that wall-mounting apparatus on-site has a sufficient load-bearing capacity. Use individual stands or primary walling, for example. Do not wall-mount the product if you cannot provide wall-mounting apparatus with a sufficient load-bearing capacity. D C Minimum clearances C D D 0 mm 00 mm 00 mm 600 mm 5 mm Note Cabinettype casing 0000675_0 Ultimate Installation and maintenance instructions 9

5 Installation 4.9 Removing/installing the front casing 4.9. Removing the front casing C C x D. Undo the two screws ().. Gently press the front casing backwards in the centre so that the latching lug is released.. Pull the front casing forwards at the bottom edge. 4. Lift the front casing upwards from the bracket. 4.9. Fitting the front panel Refit the components in the reverse order. 4.0 Removing/installing the side section 4.0. Removing the side section Caution. Risk of material damage caused by mechanical deformation. Removing both side sections may cause mechanical distortion in the product, which may cause damage to the piping, for example, and potentially result in leaks. lways remove only one side section never both side sections at the same time. Note If there is sufficient lateral clearance (at least 50 mm), you can remove the side section to facilitate maintenance or repair work.. Tilt the electronics box forward.. Hold on to the side section so that it cannot fall and unscrew both screws (), one from the top and one from the bottom.. Tilt the side section to the outside and move it downwards and out. 4.0. Installing the side section Refit the components in the reverse order. 5 Installation Danger! Risk of explosion or scalding caused by incorrect installation. Stresses in the supply line can cause leaks. Make sure there is no voltage in the supply lines when they are installed. Caution. Risk of damage caused by contaminated lines. Foreign bodies, such as welding remnants, sealing residue or dirt in the water pipes, may cause damage to the boiler. Flush the heating installation thoroughly prior to installation. 0 Installation and maintenance instructions Ultimate 0000675_0

Installation 5 5. Checking the gas meter Make sure that the existing gas meter is capable of passing the rate of gas supply required. 5. Gas and water connections 4 5 Caution. Risk of damage caused by incorrect gas connection installation. Excess test pressure or operating pressure may cause damage to the gas valve. Check the leak-tightness of the gas valve using a maximum pressure of. kpa (0 mbar). Caution. Risk of damage caused by corrosion. If non-diffusion-tight plastic pipes are used in the heating installation, this may cause air to enter the heating water and corrosion of the heat generation circuit and the boiler. If using non-diffusion-tight plastic pipes in the heating installation, separate the system by installing an external heat exchanger between the boiler and the heating installation. Heating flow connection, G/4 Hot water connection, G/4 Gas connection, G/ 4 Connection for the cold water supply line, G/4 5 Heating return connection, G/4. Connect the water and gas connections in accordance with the applicable standards.. Purge the gas line before start-up.. Check whether the connections ( Page 0) are leaktight. 5. Connecting the drain line for the expansion relief valve Caution. Risk of material damage due to heat transfer during soldering. Do not solder the connection pieces if the connection pieces are screwed to the service valves. Note We recommend that you provide the water pipes to the boiler outlet and to the system with thermal insulation. Preliminary work. Check that the system volume and the volumetric capacity of the expansion vessel are the same. If the volume of the expansion vessel is insufficient for the system. Install an additional expansion vessel in the heating return, as close to the product as possible. Install a non-return flap at the product's outlet (heating flow). Ensure that the pipeline is visible. The pipe must have a continuous fall and be routed to a position so that any discharge of water, possibly boiling, or steam cannot create any danger to persons, damage to property or external electrical components and wiring. The components must be set up in such a way that you can see the water flowing out.. Ensure that the system has the following components: stop cock in the cold water supply stop cock in the gas line filling and draining device in the heating installation 0000675_0 Ultimate Installation and maintenance instructions

5 Installation 5.4 Connecting the condensate drain pipework 5.5 Connecting the drain cock Follow the instructions listed here and observe any legal directives and local regulations on condensate discharge. Use PVC or another material that is suitable for draining the non-neutralised condensate. If you cannot guarantee that the materials from which the drain lines are made are suitable, install a system for neutralising the condensate. Ensure that the connection between the condensate drain pipework and the drain hose is not air-tight. Note The condensate drain pipework must have a continuous fall (45 mm per metre) and should whenever possible terminate at a suitable drain point within the heated envelope of the building that will remain frost free under long periods of low external temperatures. Connect the condensate siphon (). Use the supplied drain hose () for this. Connect condensate drain pipework (.5 mm, not included in the scope of delivery) () to the drain hose (). During installation remove all burs from inside of cut pipe work and avoid excessive adhesive which may trap small pockets of water close to the pipe wall which can freeze and build into a larger ice plug. s with other pipe work insulate the condensate discharge pipe to minimise any risk of freezing and beware when crossing cavities that the fall is maintained and the pipe sleeved. You can find further information in S 6789: "Specification for installing and maintaining gas-fired boilers with a nominal heat loading less than 70 kw". Connect a hose to the drain cock () and guide the free end of the hose to a suitable outflow location. 5.6 flue gas installation 5.6. Installing the air/flue pipe 5 % 50 mm/m Caution. Risk of poisoning due to escaping flue gas. Mineral-oil-based greases can damage the seals. Instead of grease, use only water or commercially available soft soap to aid installation.. Ensure that there is a minimum downward gradient of 5% between the elbow and the terminal on the air/flue pipe so that the condensate can flow back to the product.. Install the flue gas pipe in accordance with the installation instructions that are included in the scope of delivery for the air/flue pipe.. You can find out which air/flue pipes may be used by consulting the enclosed air/flue pipe installation manual. 4. Install the flue gas pipe in accordance with the installation instructions that are included in the scope of delivery for the air/flue pipe. Installation and maintenance instructions Ultimate 0000675_0

Installation 5 5.6. ir/flue gas system 5.6.. Horizontal air/flue gas system 5.6.. ir/flue gas system for header lines L The openings in an attachment for separate lines must lead to a 50 cm-sided square. For each additional 90 elbow (or two 45 elbows) that is required, the length (L) must be reduced by m. Length of the C type flue pipe ( Page 47) L 5.6.. Vertical air/flue gas system L The connections with the line are established using the accessory specially developed by the product manufacturer. boiler that is connected to a type C4 system must only be connected to natural draught chimneys. The condensate from header line systems must not drain into the boiler. For each additional 90 elbow (or two 45 elbows) that is required, the length (L) must be reduced by m. Length of the C4 type flue pipe ( Page 47) 5.7 Electrical installation The openings in an attachment for separate lines must lead to a 50 cm-sided square. For each additional 90 elbow (or two 45 elbows) that is required, the length (L) must be reduced by m. Length of the C type flue pipe ( Page 47) Danger! Risk of death from electric shock! The mains connection terminals L and N remain live even if the product is switched off: Switch off the power supply. Secure the power supply against being switched on again. 0000675_0 Ultimate Installation and maintenance instructions

5 Installation 5.7. Opening and closing the electronics box 5.7.4 Establishing the power supply. To open the electronics box, follow the instructions in the specified sequence.. To close the electronics box, follow the instructions in reverse order. 5.7. Cable route 0V. Observe all applicable regulations. The applicable regulations state that the connection must be made via an electrical partition with a contact opening of at least mm at each pole.. Make sure that the rated voltage of the mains is 0 V.. Provide one common electricity supply for the boiler and for the corresponding controller: Power supply: Single-phase, 0 V, 50 Hz Fuse protection: 4. Open the electronics box. 5. Observe the routing of the power supply cable () in the electronics box in order to guarantee the strain relief. 4V / eus 0 mm 4-V eus cable route L N RT X 0V~ 0-V eus cable route 5.7. Carrying out the wiring 0 mm max.. Shorten the connection cables to the appropriate lengths to prevent them from causing damage inside the electronics box.. Screw the plug to the connection cable.. Plug the plug into the slot provided on the PC. 6. Carry out the wiring. ( Page 4) 7. Close the electronics box. 8. Screw the supplied plug to a three-core mains connection cable that complies with the relevant standards. 9. Connect the plug for the mains connection cable. 4 Installation and maintenance instructions Ultimate 0000675_0

Operation 6 0. Make sure that access to the mains connection is always freely available and is not covered or blocked by an obstruction. 5.7.5 Connecting controllers to the electronic system 6 Operation 6. Using diagnostics codes You can use the parameters marked as in the table of diagnostics codes to adapt the product to the system and customer requirements. Overview of diagnostics codes ( Page 0) 6.. ctivating diagnostics codes.off urner off 4 V US. Press and hold the button for 7 seconds. RT US RT US 4V = - + X06 urner off 4V= RT + US is shown in the display.. Press the or button to set the value. X The access code (96) is reserved for the competent person. The access code (5) is reserved for the customer service.. Press the button to confirm. Safety thermostat for floor-standing heating 4 V controller X 4 X4 eus controller or radio receiver unit 4 Outside temperature sensor, wired. Open the electronics box.. Carry out the wiring. ( Page 4). Connect the individual components depending on the type of installation. Conditions: If installing a multi-circuit controller. Change the pump operating mode (d.8) from Eco (intermittent pump operating mode) to Comfort (continuous pump operating mode). Conditions: If you are connecting a controller (0 V). L N 0 mm RT X 0V~ Connect the controller to the main plug. Remove the bridge from the plug 4V=RT. 4. Close the electronics box. is shown in the display. 6.. Setting a diagnostics code. Press the or button to select the diagnostics code.. Press the button to confirm. The value and/or status of the diagnostics code is shown in the display.. Press the or button to set the value. 4. If you allow the value to flash for three seconds, the setting is automatically confirmed. is shown in the display for second. Note You can manually confirm the setting at any time by pressing and holding the button for less than seconds. 5. Proceed accordingly for all parameters that need to be changed. 6. Press and hold the button for seconds to finish configuring the diagnostics codes. The display switches to the basic display. 6. Displaying the status codes The status codes display the product's current operating status. Status codes Overview ( Page 4) 6.. ctivating the status codes display. Hold the button down for more than 7 seconds. S.XX is shown on the display, followed by the heating flow temperature, the internal system pressure and the cylinder temperature (depending on the version).. Press the button to exit this menu. 0000675_0 Ultimate Installation and maintenance instructions 5

7 Start-up The display switches to the basic display. 6. Using check programmes y activating various check programmes, you can trigger various special functions on the product. Check programmes Overview ( Page 0) 6.. Calling up the check programmes. Hold the button down for more than 5 seconds. ll symbols are shown in the display. is shown in the display.. Press and hold the button for five seconds. is shown in the display.. Press the or button to select the check programme. 4. Press the button to confirm. on is shown in the display and the programme starts. 5. Press the and buttons at the same time whilst running a check programme. The heating water temperature and the filling pressure for the heating installation are shown alternately in the display. 6. Press the button to return to the check programme. The display shows the check programme. 7. Press the button to finish the check programme. OFF is shown in the display. 8. Press and hold the button for seconds to finish the check programmes. End is shown in the display. The display switches to the basic display. Note If you do not press any button for 5 minutes, the current programme is automatically cancelled and the basic display is shown. 7 Start-up 7. Carrying out the initial start-up Initial start-up must be carried out by a customer service technician or an authorised competent person using the firstcommissioning-checklist. The first-commissioning-checklist in the appendix ( Page 4) of the installation instructions must be filled in and stored carefully along with the unit's documentation. Carry out the initial start-up using the first-commissioning-checklist in the appendix. Fill out and sign the first-commissioning-checklist. 7. Checking the factory setting Caution. Risk of material damage caused by making unauthorised settings. Never modify the factory setting of the gas pressure regulator of the gas valve. The product combustion is checked on-site and pre-set to the type of gas specified on the identification plate. Check the information about the type of gas indicated on the identification plate and compare this with the type of gas available at the installation location. Conditions: The product model is not compatible with the local gas type. Do not start up the product. Conditions: The product model is compatible with the local gas type. Proceed as described below. 7. Checking and treating the heating water/filling and supplementary water Caution. Risk of material damage due to poor-quality heating water Ensure that the heating water is of sufficient quality. 6.. Displaying the pressure and temperature of the heating during a check programme. Press the buttons simultaneously. Display the filling pressure in the heating installation. Display the heating flow temperature.. Press the button to display the check programme currently running. efore filling or topping up the system, check the quality of the heating water. Checking the quality of the heating water Remove a little water from the heating circuit. Check the appearance of the heating water. If you ascertain that it contains sedimentary materials, you must desludge the system. Use a magnetic rod to check whether it contains magnetite (iron oxide). If you ascertain that it contains magnetite, clean the system and apply suitable corrosion-protection measures, or fit a magnet filter. Check the ph value of the removed water at 5 C. If the value is below 6.5 or above 8.5, clean the system and treat the heating water. 6 Installation and maintenance instructions Ultimate 0000675_0

Start-up 7 Ensure that oxygen cannot get into the heating water. Ensure that oxygen cannot get into the heating water. ( Page 0) Checking the filling and supplementary water efore filling the system, measure the hardness of the filling and supplementary water. Treating the filling and supplementary water Observe all applicable national regulations and technical standards when treating the filling and supplementary water. Provided the national regulations and technical standards do not stipulate more stringent requirements, the following applies: You must treat the heating water in the following cases: If the entire filling and supplementary water quantity during the operating life of the system exceeds three times the nominal volume of the heating installation, or If the guideline values listed in the following table are not met, or if the ph value of the heating water is less than 6.5 or more than 8.5. Total heating output kw Water hardness at specific system volume ) 0 l/kw ppm CaCO₃ mol/m³ > 0 l/kw 50 l/kw ppm CaCO₃ mol/m³ > 50 l/kw ppm CaCO₃ mol/m³ < 50 < 00 < 00 0.0 > 50 to 00 > 00 to 600 00 50.5 0.0 50.5 0.0 0.0 > 600 0.0 0.0 0.0 ) Nominal capacity in litres/heating output; in the case of multiboiler systems, the smallest single heating output is to be used. Caution. The use of unsuitable heating water may cause aluminium corrosion and a resulting lack of leak-tightness. In contrast to steel, grey cast iron or copper, for example, aluminium reacts with alkaline heating water (ph value > 8.5) to produce substantial corrosion. When using aluminium, make sure that the ph value of the heating water is between 6.5 and a maximum of 8.5. Caution. Risk of material damage if the heating water is treated with unsuitable additives. Unsuitable additives may cause changes in the components, noises in heating mode and possibly subsequent damage. Do not use any unsuitable frost and corrosion protection agents, biocides or sealants. No incompatibility with our products has been detected to date with proper use of the following additives. When using additives, follow the manufacturer's instructions without exception. We accept no liability for the compatibility of any additive or its effectiveness in the rest of the heating system. dditives for cleaning measures (subsequent flushing required) Fernox F Sentinel X 00 Sentinel X 400 dditives intended to remain permanently in the system Fernox F Fernox F Sentinel X 00 Sentinel X 00 dditives for frost protection intended to remain permanently in the system Fernox ntifreeze lphi Sentinel X 500 If you have used the above-mentioned additives, inform the operator about the measures required. Inform the operator about the measures required for frost protection. 7.4 voiding danger arising from insufficient water pressure The filling pressure must be between 0.0 and 0.5 MPa (.0 and.5 bar). Note If the heating flow temperature is shown in the display, press and hold the and buttons at the same time for longer than five seconds, or temporarily deactivate heating mode in order to display the pressure. If the heating installation extends over several storeys, higher filling pressures may be required to avoid air entering the heating installation. If the water pressure falls below 0.05 MPa (0.5 bar), the value flashes in the display. If the water pressure falls below 0.0 MPa (0. bar), the product switches off. The display shows 0.0 MPa (0.0 bar). Fault F will be stored in the fault list. Top up the water in the heating installation to start up the product again. The pressure value flashes in the display until a pressure of 0.05 MPa (0.5 bar) or higher has been reached. 0000675_0 Ultimate Installation and maintenance instructions 7

7 Start-up 7.5 Switching on the product 7.7 Filling the condensate siphon Switch on the product via the main switch installed onsite. 7.6 Filling and purging the heating installation Preliminary work Flush the heating installation through. C. Check the silicone hose connection () between the pump's automatic air vent and the hydraulic console.. Remove the caps from the automatic air vents.. Fill with water until the required filling pressure is reached. Recommended filling pressure:.5 bar The heating and hot water functions cannot be activated. The pressure value flashes in the display until a pressure of 0.05 MPa (0.5 bar) or higher has been reached. n automatic air vent function is activated if the pressure exceeds 0.05 MPa (0.5 bar) for longer than 5 seconds. 4. Purge each radiator until the water escapes normally, and then retighten the system's purging valves. 5. Check that all connections are leak-tight. Conditions: If the noise persists in the boiler Purge the product again by activating check programme (P.07) and then (P.06). Check programmes Overview ( Page 0). Unclip the lower section of the siphon () from the upper section of the siphon ().. Remove the float ().. Fill the lower section of the siphon with water up to 0 mm below the upper edge of the condensate drain pipework. 4. Re-insert the float (). Note Check that the float is present in the condensate siphon. 5. Clip the lower section of the siphon () into the upper section of the siphon (). 7.8 Filling the hot water circuit. Open the water tap to fill the hot water circuit.. Close the water tap once the appropriate volume of water has flowed out. The hot water circuit is filled.. Check all connections and the entire system for leaktightness. 7.9 Checking and adjusting the gas settings Only a qualified competent person is authorised to implement the settings on the gas valve. Each destroyed seal must be restored. The CO adjusting screw must be sealed. Never modify the factory setting of the gas pressure regulator of the gas valve. 8 Installation and maintenance instructions Ultimate 0000675_0

Start-up 7 7.9. Checking the gas connection pressure (gas flow pressure). Ensure that the gas inlet working pressure can be obtained with all other gas appliances in the property working.. Close the gas isolator cock.. Undo the sealing screw on the measuring nipple (). 4. Connect a pressure gauge to the measuring nipple (). 5. Open the gas isolator cock. 6. Start up the product with check programme P.0. 7. In addition, ensure that maximum heat can be dissipated into the heating system by turning up the room thermostat. 8. With the boiler operating at full load check that the gas inlet working pressure at the reference test point () complies with the requirements. Permissible connection pressure Great ritain Natural gas G0.7 kpa (7.0 0 mbar) 9. Should the pressure recorded at the reference test point in the boiler be lower than indicated check if there is any blockage in the pipework or if the pipework is undersized. Conditions: Gas flow pressure not in the permissible range Caution. Risk of material damage and operating faults caused by incorrect gas connection pressure. If the gas connection pressure lies outside the permissible range, this can cause operating faults in and damage to the product. Do not make any adjustments to the product. Do not start up the product. If you cannot correct the failure, notify the gas supply company and proceed as follows: End check programme P.0. llow the boiler to cool down by allowing pump overrun to operate for a minimum of two minutes. Close the gas isolator cock. Remove the pressure gauge and retighten the sealing screw () for the measuring nipple. Open the gas isolator cock (). Check the measuring nipple for gas tightness. Close the gas isolator cock (). Fit the front panel. ( Page 0) Disconnect the product from the power mains. You must not start up the boiler. Conditions: Gas flow pressure in the permissible range End the check programme P.0. llow the boiler to cool down allowing pump overrun to operate for a minimum of two minutes. Close the gas isolator cock (). Remove the pressure gauge and retighten the sealing screw () for the measuring nipple. Open the gas isolator cock (). Check the measuring nipple for gas tightness. Fit the front panel. ( Page 0) Reset boiler controls for normal operation. Record the appliance gas inlet working pressure (kpa resp. mbar) in the enchmark gas boiler commissioning checklist. 7.9. Checking the leak-tightness of the flue gas system and for flue gas recirculation. Check that the flue gas system is intact, in accordance with ritish Gas T 00.. If the flue gas installation is longer than m, a flue gas recirculation test is strongly recommended. This test must be carried out in accordance with the instructions below.. Use the air analysis point () to check for flue gas recirculation. 4. Use the flue gas measuring instrument. 5. If you discover CO or CO in the fresh air, search for a leak in the flue gas system or for the flue gas recirculation. 6. Eliminate the damage. 7. Repeat the above-mentioned test to determine if the fresh air contains CO or CO. 8. If you cannot eliminate the damage, you must not start up the boiler. 7.9. Thoroughly flushing the heating installation ("hot"). Operate the appliance until the boiler and the heating system are up to temperature.. Check the heating system for leaks.. Connect a hose to the drain valve located at the lowest position of the heating system. 4. Shut off the boiler, open the drain valve and all purge valves on the radiators and allow the water to flow out of the heating system and the boiler quickly and fully. 5. Close the drain valve. 6. Fill and purge the heating installation. ( Page 8) 7. Re-fill the system until the system design pressure of 0, MPa (,0 bar) is attained. 0000675_0 Ultimate Installation and maintenance instructions 9

8 dapting the unit to the heating installation Note The actual reading on the digital pressure gauge should ideally be 0,05 MPa (0,5 bar) plus an additional pressure corresponding to the highest point of the system above the base of the boiler 0 m head equals an additional bar reading on the pressure gauge. The minimum pressure should not be less than 0, MPa ( bar) in any installation. If the system is to be treated with an inhibitor it should be applied at this stage in accordance with the manufacturer s instructions. Further information can be obtained from Sentinel, etz Dearborn Ltd., Tel: 05 40 9595, or Fernox, lpha Fry technologies. Tel: 0870 87006. 8. Fit the front panel. ( Page 0) 7.9.4 Checking the CO₂ content. Start up the product with the check programme (P.0) and set the value. Setting value for the programme P.0: 00 Check programmes Overview ( Page 0). Wait until the value that is read is stable. Waiting period for reading a stable value: 5 min 7.0 Checking function and leak-tightness efore you hand the product over to the operator: Check the gas line, the flue gas installation, the heating installation and the hot water pipes for leaks. Check that the air/flue pipe and condensate drain pipework have been installed correctly. Check that the front casing has been installed correctly. 7.0. Checking the heating mode. ctivate the heating mode on the user interface.. Turn all thermostatic radiator valves on the radiators until they are fully open.. llow the product to operate for at least 5 minutes. 4. Purge the heating installation. 5. ctivate the display for the current operating status. ( Page 5) Status codes Overview ( Page 4) If the product is working correctly, the display shows S.04. 7.0. Checking the hot water generation. ctivate the hot water handling mode on the user interface.. Open a hot water valve completely.. ctivate the display for the current operating status. ( Page 5) Status codes Overview ( Page 4) If the product is working correctly, the display shows S.4.. Unscrew the cover from the flue gas analysis point (). 4. Measure the CO₂ content at the flue gas analysis point (). 5. Compare the measured value with the corresponding value in the table. Checking the CO₂ content Great ritain Removed front casing/installed front casing Natural gas G0 9. ± % The value is OK. The value is not OK; you cannot start up the product. Inform Customer Service. 8 dapting the unit to the heating installation You can reset/change the system parameters (section "Using diagnostics codes"). Overview of diagnostics codes ( Page 0) 8. urner anti-cycling time To prevent frequent switching on and off of the burner and thus prevent energy losses, an electronic restart lockout is activated for a specific period each time the burner is switched off. The burner anti-cycling time is only active for the heating mode. Hot water handling mode during a burner anti-cycling time does not affect the time function element. 8.. Setting the maximum burner anti-cycling time. Set the diagnostics code. ( Page 5) Overview of diagnostics codes ( Page 0). If required, adjust the maximum burner anti-cycling time using the diagnostics code d.0. 0 Installation and maintenance instructions Ultimate 0000675_0

djusting the hot water temperature 9 8.. Resetting the remaining burner anti-cycling time Hold the button down for more than seconds. 8. Setting the bypass Conditions: Two-stage pump is shown in the display. 8. Setting the pump output Conditions: Two-stage pump If required, use diagnostics code d.9 to adjust the setting for the operating-mode-dependent pump speed. Set the diagnostics code. ( Page 5) Overview of diagnostics codes ( Page 0) Flow rate-pressure curves for 0 kw (pressure measured downstream of the valves) 70 60 50 40 0 0 0 0 500 000 500 Maximum speed (bypass closed) Maximum speed (default setting for the bypass) Minimum speed (default setting for the bypass) 4 Flow rate at maximum output (ΔT = 0K) Throughput in circuit (l/h) vailable pressure (kpa) Flow rate-pressure curves for 5 kw (pressure measured downstream of the valves) 70 60 50 40 0 0 0 0 500 000 500 4 4 Remove the front casing. ( Page 0) Regulate the pressure using the adjusting screw (). Fit the front panel. ( Page 0) Position of the adjusting screw Right-hand stop (screwed all the way in) Mid-position (six anticlockwise rotations) Five further anti-clockwise rotations starting from the mid-position Notes/application If the radiators do not heat up sufficiently at the default setting. In this case, you must set the pump to the maximum speed. Default setting If noises are produced in the radiators or radiator valves. 9 djusting the hot water temperature You can reset/change the system parameters ( section "Using diagnostics codes"). Overview of diagnostics codes ( Page 0) 9. Setting the hot water temperature Danger! Risk of death from Legionella. Legionella multiply at temperatures below 60 C. Ensure that the operator is familiar with all of the nti-legionella measures in order to comply with the applicable regulations regarding legionella prevention. Maximum speed (bypass closed) Maximum speed (default setting for the bypass) Minimum speed (default setting for the bypass) 4 Flow rate at maximum output (ΔT = 0K) Throughput in circuit (l/h) vailable pressure (kpa) Set the hot water temperature. Conditions: Water hardness: >.57 mol/m³ Hot water temperature: 50 0 Handing the product over to the operator When you have finished the installation, attach the sticker supplied (in the operator's language) to the product cover. 0000675_0 Ultimate Installation and maintenance instructions

Inspection and maintenance Explain to the operator how the safety devices work and where they are located. Inform the operator how to handle the product. In particular, draw attention to the safety information which the operator must follow. Inform the operator of the necessity to have the product maintained on a regular basis. Instruct the operator about measures taken to ensure the supply of combustion air and flue gas pipe. Inspection and maintenance. Observing inspection and maintenance intervals dhere to the minimum inspection and maintenance intervals. Depending on the results of the inspection, it may be necessary to bring maintenance work forward. Inspection and maintenance work Overview ( Page 40). Procuring spare parts The original components of the product were also certified as part of the declaration of conformity. If you do not use certified Glow-worm original spare parts for maintenance or repair work, this voids the conformity of the product. We therefore strongly recommend that you install Glow-worm original spare parts. Information about available Glow-worm original spare parts is available by contacting the contact address provided on the reverse of this document. If you require spare parts for maintenance or repair work, use only Glow-worm original spare parts.. Checking the CO₂ content. Start up the product with the check programme (P.0) and set the value. Setting value for the programme P.0: 00 Check programmes Overview ( Page 0). Wait until the value that is read is stable. Waiting period for reading a stable value: 5 min. Unscrew the cover from the flue gas analysis point (). 4. Measure the CO₂ content at the flue gas analysis point (). 5. Compare the measured value with the corresponding value in the table. Checking the CO₂ content Great ritain Removed front casing/installed front casing Natural gas G0 9. ± % The value is OK. The value is not OK; you cannot start up the product. Set the CO₂ content. ( Page ).4 Setting the CO₂ content Conditions: The CO₂ content must be adjusted Turn the screw () to set the CO₂ content (value with front casing removed). To increase the CO₂ content: Turn anti-clockwise To decrease the CO₂ content: Turn clockwise Only carry out the adjustment in increments of /8 turn and wait approximately minute after each adjustment until the value has stabilised. Compare the measured value with the corresponding value in the table. Setting the CO₂ value CO₂ at full load Set for Wobbe index W₀ O₂ at full load CO at full load Great ritain Removed front casing/installed front casing Natural gas G0 9. ±0. % 4.09 kw h/m³ 4.5 ±.8 vol. % 50 ppm CO/CO₂ 0.007 If the setting is not in the specified adjustment range, you must not start up the product. Installation and maintenance instructions Ultimate 0000675_0

Inspection and maintenance Inform Customer Service. Check whether the air-quality requirements with regard to carbon monoxide are fulfilled. Install the front casing. 6.5 Removing the gas-air mixture unit Note The gas-air mixture unit consists of three main components: D Ventilator Gas valve, urner cover C. Switch off the product via the main switch.. Close the gas isolator cock.. Remove the front casing. ( Page 0) 8. Remove the gas-air mixture unit (6). 7 7 8 9. Remove the burner seals (7) and the burner (8). 0. Check the burner and the heat exchanger for damage and dirt.. If necessary, clean or replace the components according to the following sections.. Install the two new burner seals. C.6 Cleaning the heat exchanger 4. Push the clip () upwards. 5. Remove the flue pipe (). 5 4. Protect the folded down electronics box against sprayed water.. Clean the ribs of the heat exchanger () with water. The water runs out into the condensate tray. 6. Remove the air intake pipe (). 7. Remove the plugs from the gas valve (4) and from the fan (5). 0000675_0 Ultimate Installation and maintenance instructions