Technical Committee on Portable Fire Extinguishers

Similar documents
First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

Change all instances of "flame resistant (hypobaric)" to "Limited-Combustible (material)" in all instances in the document.

Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Second Revision No. 3-NFPA [ Section No. 2.3 ]

12/21/2015 National Fire Protection Association Report

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ]

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference

TECHNICAL COMMITTEE ON SAFETY AT MOTORSPORTS VENUES. NFPA 610 First Draft Meeting. October 17-18, 2016

MEMORANDUM. NFPA 51 First Draft Technical Committee FINAL Ballot Results (A2017 Cycle)

PORTABLE FIRE EXTINGUISHERS

Technical Committee on Record Protection (REA-AAA)

Page 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Second Revision No. 1 NFPA [ Chapter 2 ]

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

Public Input No. 3-NFPA [ Chapter 2 ]

Public Comment No. 7-NFPA [ Section No. 2.3 ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

First Revision No. 1-NFPA [ Chapter 2 ]

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle)

Page 1 of 11. Public Input No. 1-NFPA 12A-2015 [ Chapter 2 ] Referenced Publications. 2.1 General.

Public Input No. 16-NFPA [ Section No ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Throughout standard remove references to the following and replace with the following:

WORKING DRAFT OF COMMITTEE MEETING OUTPUT

FIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES

UNIFIED FACILITIES GUIDE SPECIFICATIONS

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

June 2018 Safety Meeting Fire Extinguishers Part I

COUNTY OF ROCKLAND Department of General Services Purchasing Division


First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes


First Revision No. 1-NFPA 30A-2015 [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Model Policy On Portable Fire Extinguishers (Ontario Version)

Public Comment No. 1-NFPA [ Section No ]

Capital Projects Group Fire Extinguishers Specification

Remove the "Exception" text to be consistent with direction provided in the MOS.

Second Revision No. 2-NFPA [ Section No ]

Public Comment No. 13-NFPA [ Section No ]

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

I. Welcome and call to order by Chairman Kann. Review and accept minutes from the October 2012 meeting. V. Task Group report on NFPA 1003 work

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

4/18/2017. *2012 edition of NFPA 99 has gone through a major overhaul. *This document is now a Code.

TEXAS DEPARTMENT OF TRANSPORTATION PORTABLE FIRE EXTINGUISHER SERVICES ANNUAL INSPECTION MAINTENANCE, REPAIR, AND RECHARGING

Public Input No. 4-NFPA [ Section No. 4.2 ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

UFGS (June 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

First Draft Meeting (F2017) Agenda Friday, March 11 th, :30 AM 4:00 PM ET

Reference to the Smoke Damage Index (SDI) is needed as it is part of the test method.

Public Comment No. 22-NFPA [ New Section after 1.4 ] Statement of Problem and Substantiation for Public Comment

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

Committee Input No. 1-NFPA [ Chapter 2 ]

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector

NOTICE. (Formulated under the cognizance of the CTA R3 Audio Systems Committee.)

NFPA 550 ROP Meeting Minutes

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

Location of Requirements Listed Category I appliances Type B gas vent 12.7 Listed appliances equipped with. Chimney Single wall metal pipe 12.

Standard Compared 2012 Changes of the International Building Code and National Fire Protection Association- 101

National Fire Protection Association M E M O R A N D U M. Technical Committee on Testing and Maintenance of Fire Alarm and Signaling Systems

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector Permit

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

Airworthiness Directives; Kidde Aerospace Part Number (P/N) Hand-Held Halon Fire Extinguishers

COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Subject: BSR Uniform Mechanical Code, 2015 Edition: Appeal on Proposal #333

Hydrostatic Retest Requirements for ANSUL Pressure Vessels

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Technical Committee on Heliports (HHH-AAA)

Committee on 51A M E M O R A N D U M. NFPA Technical Committee on Industrial and Medical Gases

MEMORANDUM. Technical Committee on Emergency Power Supplies. NFPA 111 First Draft Technical Committee FINAL Ballot Results (A2018)

Australian/New Zealand Standard

OPTIONAL INFORMATION PORTABLE FIRE EXTINGUISHERS SELF INSPECTION CHECKLIST

ARKANSAS FIRE PROTECTION LICENSING BOARD ACT 743 OF 1977

Public Input No. 2-NFPA [Chapter F]

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement

SPECIFICATION: ARGONITE Engineered Fire Suppression System

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

Public Input No. 48-NFPA [ Section No ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Public Input No. 107-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

First Revision No. 20-NFPA [ Section No ]

First Revision No. 7-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

NFPA 37 Public Comment Responses Page 1 of 32

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ENGINEER AND THE TECHNICIAN DESIGNING FIRE PROTECTION SYSTEMS.

SC # /16/17/18/19/23/24 D#03-24

9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement

Transcription:

Technical Committee on Portable Fire Extinguishers DATE: February 29, 2016 TO: FROM: M E M O R A N D U M Principal and Alternate Members of the Technical Committee on Portable Fire Extinguishers Barry Chase, NFPA Staff Liaison Office: (617) 984-7259 Email: bchase@nfpa.org SUBJECT: AGENDA NFPA 10 and NFPA 408 Second Draft Meeting (Fall 2016) March 15-16, 2016, Four Points by Sheraton French Quarter, New Orleans, LA Lunch will be provided in the meeting room on March 15, starting at 11:30 am CT. Lunch on March 16 will be on your own. 1. Call to Order March 15, 2016, 1:00 pm CT 2. Introductions and Attendance 3. Chair s Comments and Agenda Review 4. NFPA Staff Liaison Presentation a. NFPA Standards Development Process b. Fall 2016 Revision Cycle Schedule c. NFPA Resources 5. Approval of Previous Meeting Minutes a. April 21-23, 2015 NFPA 10 & NFPA 408 First Draft Meeting (Orlando, FL) 6. NFPA 10 Second Draft a. Address Public Comments (8 submittals, ATTACHED) b. Task Group on Combustible Metals (Talbert) c. Presentation on the Global Harmonization System (GHS) by Gregg Ublacker (Director, Product Stewardship & Regulatory Affairs Tyco Fire Protection Products) d. Committee Revisions 7. NFPA 408 Second Draft a. Address Public Comments (0 submittals) b. Committee Revisions 8. Review NFPA 59 Committee Input No. 11 (ATTACHED) 9. Other Business 10. Next Meeting Please submit requests for additional agenda items to the chair at least seven days prior to the meeting, and notify the chair and staff liaison as soon as possible if you plan to introduce any committee revisions at the meeting. All NFPA Technical Committee meetings are open to the public. Please contact me for information on attending a meeting as a guest. Read NFPA's Regulations Governing the Development of NFPA Standards (Section 3.3.3.3) for further information. Page 1 of 2 Page 1 of 15

Technical Committee on Portable Fire Extinguishers (PFE-AAA) NFPA 10 and NFPA 408 Second Draft Meeting (Fall 2016) Tuesday, March 15 - Wednesday, March 16, 2016 Four Points by Sheraton French Quarter, New Orleans, LA Additional Meeting Information: See the Meeting Notice on the Document Information Page www.nfpa.org/10next or www.nfpa.org/408next for meeting location details. If you have any questions, please feel free to contact Kim Shea, Project Administrator at 617-984-7953 or by email kshea@nfpa.org. C. Standards Administration Page 2 of 2 Page 2 of 15

Public Comment No. 31-NFPA 10-2015 [ Section No. 2.3 ] 2.3 Other Publications. 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM D5391, Standard Test for Electrical Conductivity and Resistivity of a Flowing High Purity Water Sample, 2014. 2.3.2 ACA Publications. American Coatings Association, 1500 Rhode Island Avenue, NW, Washington, DC 20005. Hazardous Materials Identification System (HMIS), Implementational Manual,Fourth Edition. 2.3.3 CGA Publications. Compressed Gas Association, 14501 George Carter Way, Suite 103, Chantilly, VA 20151-1788. CGA C-1, Methods for Pressure Testing Compressed Gas Cylinders, 2009. CGA G-10.1, Commodity Specification for Nitrogen, 2008. 2.3.4 UL Publications. Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062-2096. UL 1093, Standard for Halogenated Agent Fire Extinguishers, 1995, Revised 2008. (Withdrawn) UL 1803, Standard for Factory Follow-Up on Third Party Certified Portable Fire Extinguishers, 2012. 2.3.5 ULC Publications. Underwriters Laboratories of Canada, 7 Underwriters Road, Toronto, Ontario M1R 3A9, Canada. CAN/ULC-S512, Standard for Halogenated Agent Hand and Wheeled Fire Extinguishers, 2005, reaffirmed 2007. 2.3.6 UL/ULC Publications. The following publications are bi-nationally harmonized standards for Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062-2096, and Underwriters' Laboratories of Canada, 7 Underwriters Road, Toronto, Ontario M1R 3A9, Canada. ANSI/UL 8, ULC CAN /ULC -S554, Water Based Agent Fire Extinguishers, 2011. ANSI/UL 154, ULC CAN /ULC -S503, Standard for Carbon-Dioxide Fire Extinguishers, 2014. ANSI/UL 299, ULC CAN /ULC -S504, Standard for Dry Chemical Fire Extinguishers, 2012. ANSI/UL 626, ULC CAN /ULC -S507, Standard for Water Fire Extinguishers, 2012. ANSI/UL 711, ULC CAN /ULC -S508, Standard for Rating and Fire Testing of Fire Extinguishers, 2013. ANSI/UL 2129, ULC CAN /ULC -S566, Standard for Halocarbon Clean Agent Fire Extinguishers, 2014. 2.3.7 UN Publications. United Nations, Publications Customer Service, PO Box 960, Herndon, VA 20172. GHS, Globally Harmonized System of Classification and Labeling of Chemicals, ST/SG/AC.10/30/Rev. 6, 2015. Page 3 of 15

2.3.8 U.S. Government Publications. U.S. Government Printing Publishing Office, 732 North Capitol Street, NW, Washington, DC 20402 20401-0001. Title 49, Code of Federal Regulations, Part 180.209, Requirements for Requalification of Specification Cylinders, 2015. Title 49, Code of Federal Regulations, Part 180.213, Requalification Markings, 2015. 2.3.9 Other Publications. Merriam-Webster's Collegiate Dictionary, 11th edition, Merriam-Webster, Inc., Springfield, MA, 2003. Referenced current GPO, name, and address. First Revision No. 1-NFPA 10-2015 [Section No. 2.2] Submitter Full Name: Aaron Adamczyk Organization: [ Not Specified ] Submittal Date: Tue Sep 29 00:22:56 EDT 2015 Page 4 of 15

Public Comment No. 56-NFPA 10-2015 [ Section No. 6.1.3.10.6 ] 6.1.3.10.6 Only surface mounted cabinets or fire-rated cabinets shall be installed in 1-hour and 2-hour fire-resistance-rated walls. Only surface mounted cabinets or fire-rated cabinets which are specially constructed with gypsum board installed on the sides, top, bottom, and back and are intended to be installed in any fire-resistance-rated walls. Cabinets that are not fire-rated should not be installed in these walls as they would make the entire fire-rated wall non-compliant. First Revision No. 31-NFPA 10-2015 [New Section after 6.1.3.10.5] Submitter Full Name: Mark Conroy Organization: Brooks Equipment Company Submittal Date: Tue Nov 10 14:57:11 EST 2015 Page 5 of 15

Public Comment No. 6-NFPA 10-2015 [ Section No. 7.2.1.2 [Excluding any Sub-Sections] ] Fire extinguishers and Class D extinguishing agents shall be inspected either manually or by means of an electronic monitoring device/system at intervals not exceeding 31 days. Replace existing text with: Fire extinguishers and Class D extinguishing agents shall be inspected either manually or by means of an electronic monitoring device/system at intervals no fewer than 20, and no greater than 40, days following the previous inspection. The current 31 day maximum interval is not practical in reality (given human elements, work schedules, holidays, illness, vacations, etc). I am certain the intent is for extinguishers to receive inspection once per month, at an interval that is neither too close to, nor too far from, the previous inspection. The 20 to 40 day range provides a reasonable, practical and achievable interval that, if followed, will reasonably ensure equipment reliability. If 20 days would be considered too soon, or 40 days too late, then adjust to what would be considered reasonable and practical...22 days and 38 days...24 days and 36 days. Practicality is the key. Public Input No. 186-NFPA 10-2014 [Section No. 7.2.1.2 [Excluding any Sub-Sections]] Submitter Full Name: THOMAS KRETZLER Organization: ALBANY FIRE EXTINGUISHER SALES & SERVICE, INC Submittal Date: Fri Aug 28 11:46:50 EDT 2015 Page 6 of 15

Public Comment No. 7-NFPA 10-2015 [ Sections 7.2.1.2, 7.2.1.3, 7.2.1.4 ] Sections 7.2.1.2, 7.2.1.3, 7.2.1.4 7.2.1.2* Fire extinguishers and Class D extinguishing agents shall be inspected either manually or by means of an electronic monitoring device/system at intervals not exceeding 31 days. 7.2.1.2.1 Fire extinguishers and Class D extinguishing agents shall be inspected at least once per calendar month. 7.2.1.3 In facilities where fire extinguisher inspections are scheduled and tracked via an electronic database the inspection interval shall not exceed 45 days,and in no case will the average time between inspections be allowed to exceed 31 days without regard to calendar months. 7.2.1.4 * Fire extinguishers and Class D extinguishing agents shall be manually inspected daily or weekly when conditions exist that indicate the need for more frequent inspections. 7.2.1.4 5 Extinguishers that are electronically monitored for location only, such as those monitored by means of a switch to indicate when the extinguisher is removed from its bracket or cabinet, shall be manually inspected in accordance with 7.2.2. NFPA 10 has long asserted that the intent of the code is to require 12 inspections with one inspection per month. At many smaller facilities where this inspection work is done by personnel during the normal course of their duties who work on site full time the current requirements are not onerous. However at large facilities that utilize outside contractors for these inspections the current requirements are untenable. This requirement is really only able to be fulfilled "to the letter" without changing the basic assumption of how many inspections need to be done by inspecting each extinguisher on the same calendar DAY of each month, otherwise inspections will have to be more frequent than 31 days until the shortened frequency eventually causes 13-14 inspections per year or more depending on scheduling. Our client currently owns approximately 5500 extinguishers including large numbers of extinguishers in clean rooms and other dangerous to access locations. These extinguishers are inspected on a 4 week rotation by trained dedicated inspectors. Each inspection has a window of time to be performed. These inspections are scheduled and tracked by a preventative maintenance system designed to FDA standards. Because of the access requirements etc the exact day that each extinguisher is inspected can vary within the inspection window. In order to fully comply with the code as written our client would in effect be forced to change to a 2 or 3 week inspection interval at significant expense to their operations. The calendar month requirement as far as I can work out appears to be biased to the idea that extinguishers still have monthly inspection tags and those tags need filled out. Our client's need both to eliminate paper in sensitive processing areas and to prevent well-meaning employees from inspecting extinguishers themselves (or calling every time one isn't updated on the first of the month) precludes the use of tags. I cannot see how anyone can argue that a company inspecting extinguishers 13 times a year is not meeting the intent of the code. Even using an aggressive scheduling window (much more aggressive than the client currently utilizes) such as 28 days apart, 9 days to complete (5 business days plus 2 weekends to ensure that no mater what day the scheduled start is you get a business week to complete which does not give any regard to holidays etc) you could see a deviation of up to 46 days between inspections. However if you inspected at the far ends of both windows you would ultimately end up with much shorter duration between them and the adjacent PMs. This also can cause months to be skipped even with 13 inspections per year. Trying to complete the inspection of 1300 plus extinguishers in one week every 4 weeks is a daunting task for the contractor. Page 7 of 15

While our client is not the norm, I am sure they are not the only one facing this issue. I believe our client to be at the forefront of fire protection compliance, and if they are having a hard time fulfilling a requirement I don't believe it's because of a lack of effort on their part. My only stake in this is as a code researcher for the client, our company does not handle fire extinguisher inspection. As a CFPS, and multiple NICET certificate holder I could not find a reasonable basis to defend the standard as written in the last 2 editions. Even if my change as written is not acceptable I believe the committee needs to strongly reconsider the direction the code has taken on this issue and provide a solution that is workable for owners in large scale facilities as well as volume service providers who I seriously doubt are working Sundays to make sure every month on the same calendar day that extinguishers are inspected. I believe the current writing does less to increase compliance and safety than it will to increase the number of code violation citations. Public Input No. 186-NFPA 10-2014 [Section No. 7.2.1.2 [Excluding any Sub-Sections]] Submitter Full Name: MIKE MOREY Organization: BMWC CONSTRUCTORS Submittal Date: Thu Sep 10 08:26:02 EDT 2015 Page 8 of 15

Public Comment No. 4-NFPA 10-2015 [ Section No. 7.3.4.1 [Excluding any Sub-Sections] ] Each fire extinguisher shall have a tag or label securely attached that indicates that maintenance was performed. Add: Any extinguisher due, or past due, for internal maintenance or hydrostatic testing shall not be tagged or labeled as having undergone maintenance until such internal maintenance or testing has been performed. Some service agents seem to have adopted a procedure in which they will tag extinguishers for annual maintenance year after year without ever addressing the required internal maintenance or hydrostatic testing. The result: Portable extinguishers giving the appearance to owners, AHJ's and others that they are current on all maintenance & testing requirements, when they are in fact out of compliance, potentially unsafe and more prone to malfunction. The language I have proposed will close the loophole which currently seems to be allowing service agents to tag non-compliant equipment. First Revision No. 40-NFPA 10-2015 [Section No. 7.3.4.3] Submitter Full Name: THOMAS KRETZLER Organization: ALBANY FIRE EXTING SALES SVC Submittal Date: Thu Aug 27 11:05:44 EDT 2015 Page 9 of 15

Public Comment No. 49-NFPA 10-2015 [ Section No. 7.3.6 ] 7.3.6 Six-Year Internal Examination of Certain Types of Extinguishers. Every 6 years, following the required 12-year hydrostatic test, stored-pressure fire extinguishers that require a 12-year hydrostatic test shall be emptied and subjected to the applicable internal and external examination procedures as detailed in the manufacturer's service manual and this standard. 7.3.6.1 When the applicable maintenance procedures are performed during periodic recharging or hydrostatic testing, the 6-year requirement shall begin from that date. 7.3.6.2 * The removal of agent from halon agent fire extinguishers shall only be done using a listed halon closed recovery system. 7.3.6.3 Nonrechargeable fire extinguishers shall not be required to have a 6-year internal examination and shall not be hydrostatically tested but shall be removed from service at a maximum interval years from the date of manufacture. 7.3.6.3.1 Nonrechargeable halon agent fire extinguishers shall be disposed of in accordance with 7.2.3.3. 7.3.6.4 Corrective Action. When an internal examination of any fire extinguisher reveals a deficiency, immediate corrective action shall be taken. 7.3.6.5 * Six-Year Internal Examination Label. Fire extinguishers that pass the applicable 6-year requirement of 7.3.6 shall have the maintenance information recorded on a durable weatherproof label that is a minimum of 2 in. 3 1 2 in. (51 mm 89 mm). 7.3.6.5.1 The new label shall be affixed to the shell by a heatless process, and any previous 6-year internal examination labels shall be removed. 7.3.6.5.2 These labels shall be of the self-destructive type when their removal from a fire extinguisher is attempted. 7.3.6.5.3 The 6-year internal examination label shall, as a minimum, identify the following: (1) Month and year the 6-year internal examination was performed (2) Person performing the work (3) Name of the agency performing the work The NFPA installed the requirement for six-year internal examination of fire extinguishers in 1985 as a manufactures recommendation. I understand at that time the extinguishers may have been being serviced with air. This created valve, stem and O-ring issues. Today extinguishers are serviced from the manufacture with nitrogen. Discharging a factory filled extinguisher that has no issues to prevent issues is illogical when measured against Public Input #141. NFPA 7.3.6.3 Nonrechargeable fire extinguishers shall not be required to have a 6 year internal examination and shall not be hydrostatically tested but shall be removed from service at a maximum interval years from the date of manufacture. Page 10 of 15

Related Public Comments for This Document Related Comment Relationship Public Comment No. 50-NFPA 10-2015 [Section No. 7.3.6] Public Input No. 141-NFPA 10-2014 [Section No. 7.3.6.3 [Excluding any Sub-Sections]] Submitter Full Name: DOUGLAS J BANKSTON Organization: FORT KNOX FIRE DEPT Submittal Date: Tue Oct 27 10:59:22 EDT 2015 Page 11 of 15

0 Public Comment No. 50-NFPA 10-2015 [ Section No. 7.3.6 ] 7.3.6 Six-Year Internal Examination of Certain Types of Extinguishers. Every 6 years, stored-pressure fire extinguishers that require a 12-year hydrostatic test shall be emptied and subjected to the applicable internal and external examination procedures as detailed in the manufacturer's service manual and this standard. 7.3.6.1 When the applicable maintenance procedures are performed during periodic recharging or hydrostatic testing, the 6-year requirement shall begin from that date. 7.3.6.2* The removal of agent from halon agent fire extinguishers shall only be done using a listed halon closed recovery system. 7.3.6.3 Nonrechargeable fire extinguishers shall not be required to have a 6-year internal examination and shall not be hydrostatically tested but shall be removed from service at a maximum interval years from the date of manufacture. 7.3.6.3.1 Nonrechargeable halon agent fire extinguishers shall be disposed of in accordance with 7.2.3.3. 7.3.6.4 Corrective Action. When an internal examination of any fire extinguisher reveals a deficiency, immediate corrective action shall be taken. 7.3.6.5* Six-Year Internal Examination Label. Fire extinguishers that pass the applicable 6-year requirement of 7.3.6 shall have the maintenance information recorded on a durable weatherproof label that is a minimum of 2 in. 3 1 2 in. (51 mm 89 mm). 7.3.6.5.1 The new label shall be affixed to the shell by a heatless process, and any previous 6-year internal examination labels shall be removed. 7.3.6.5.2 These labels shall be of the self-destructive type when their removal from a fire extinguisher is attempted. 7.3.6.5.3 The 6-year internal examination label shall, as a minimum, identify the following: (1) Month and year the 6-year internal examination was performed (2) Person performing the work (3) Name of the agency performing the work Six year maintenance of rechargeable extinguishers is an unnecessary cost to the consumer.the initial resolution is a substantial savings of tax payer dollars. Federal fire departments having adopted the NFPA have an obligation to adhere to the standards. The man hours alone on this installation are cost prohibitive. We house the largest government facility outside of the pentagon nearly 1M sq. ft. We are allotted zero funding for parts, labor or maintenance of the hundreds of extinguishers in this or the other 900 facilities on this installation. The major extinguisher manufactures now charge with nitrogen reducing the chance of caking and corrosion. There have been suggestions to remove extinguishers completely from facilities that are fully sprinkled, (of which I am not a Page 12 of 15

1 proponent). The fact that non-rechargeable extinguisher can remain in service for 12 years without service, yet a factory serviced rechargeable must undergo 6 year maintenance. Are there separate schools of thought as to the importance of extinguishers? If so why not re-evaluate this 30 year old requirement. If a six year inspection is to remain a requirement for rechargeable extinguishers then I propose it go into effect 6 years after the 12 year hydrostatic test. Related Public Comments for This Document Related Comment Public Comment No. 49-NFPA 10-2015 [Section No. 7.3.6] Public Input No. 114-NFPA 10-2013 [Section No. 5.1.2] Relationship Submitter Full Name: DOUGLAS J BANKSTON Organization: FORT KNOX FIRE DEPT Submittal Date: Tue Oct 27 12:42:39 EDT 2015 Page 13 of 15

2 Public Comment No. 54-NFPA 10-2015 [ Section No. K.1.2 ] K.1.2 K.1.2.1 Other Publications. ACA Publications. American Coatings Association, 1500 Rhode Island Avenue, NW, Washington, DC 20005. Hazardous Materials Identification System (HMIS) Implementational Manual, Fourth Edition. K.1.2.2 CGA Publications. Compressed Gas Association, 14501 George Carter Way, Suite 103, Chantilly, VA 20151-1788. CGA C-1, Methods for Pressure Testing Compressed Gas Cylinders, 2009. K.1.2.3 UL Publications. Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062-2096. UL 1093, Standard for Halogenated Agent Fire Extinguishers, 1995, revised 2008. (Withdrawn) K.1.2.4 ULC Publications. Underwriters Laboratories, 7 Underwriters Road, Toronto, Ontario M1R 3A9, Canada. ULC CAN /ULC -S512, Standard for Halogenated Agent Hand and Wheeled Fire Extinguishers, 2005, reaffirmed 2007. K.1.2.5 UL/ULC Publications. The following publications are binationally harmonized standards for Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062-2096, and Underwriters Laboratories of Canada, 7 Underwriters Road, Toronto, Ontario M1R 3A9, Canada. ANSI/ UL 299, ULC CAN /ULC -S504, Standard for Dry Chemical Fire Extinguishers, 2012. ANSI/ UL 711, ULC CAN /ULC -S508, Standard for Rating and Fire Testing of Fire Extinguishers, 2013. ANSI/ UL 2129, ULC CAN /ULC -S566, Standard for Halocarbon Clean Agent Fire Extinguishers, 2014. UL 1093 has been withdrawn. First Revision No. 11-NFPA 10-2015 [Section No. K.1.2] Submitter Full Name: Aaron Adamczyk Organization: [ Not Specified ] Submittal Date: Mon Nov 09 23:13:54 EST 2015 Page 14 of 15

of 1 http://submittals.nfpa.org/terraviewweb/formlaunch?id=/terraview/c... 2/29/2016 8:55 AM Committee Input No. 11-NFPA 59-2015 [ Section No. 13.5.1.1 ] 13.5.1.1 The minimum size portable dry chemical extinguisher for gas fires shall be 18 lb (8.2 kg) with a B:C rating rated 60-B:C. A.13.5.1.1 In areas containing common combustibles (Class A fires), a dry chemical extinguisher with a rating of 4-A:60-B:C would satisfy this requirement and could also satsfy the need for extinguishers for Class A fires. Submitter Full Name: Eric Nette Organization: [ Not Specified ] Submittal Date: Wed Oct 28 14:04:48 EDT 2015 Committee Statement and Meeting Notes Committee Statement: The committee would like to hold this open for the next draft meeting after receiving additional information on fire extinguishers to ensure that the extinguishers are equivalent. The committee recognizes that further discussion about fire extinguisher type or rating and the intention of this extinguisher needs to be addressed. Public Input No. 8-NFPA 59-2015 [Section No. 13.5.1.1] Ballot Results This item has not been balloted Page 15 of 15