SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

Similar documents
Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Ramsey Motion Monitoring Systems

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

DSD-3 DIFFERENTIAL SPEED DETECTOR

Carbon Monoxide Transmitter

Process Protection. MFA 4P Motion Failure Alarm

vibration switch

Software Version 2.01 LEVEL MONITOR MODEL 220

Pioneer-R16 Gas Monitor Operator s Manual

OVEN INDUSTRIES, INC.

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Belt Conveyor Safety Monitoring Devices

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

Tachometer/Hourmeter/Trip. Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

MT-374B/364B Operation User s Guide. The Anti-Sweat Energy Saving Controller user s manual

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Sitron s CF Line of Flow Switch Monitors

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

SCHMIDT LED Measured Value Display MD Instructions for Use

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Ammonia Leak Detector Manual

EXPERT TRI-STAR. Temperature controller. User s Manual

Cimco Series 21. Series 21 - Operator Instruction Manual INDEX. Description. Standard Instructions 2 to 4. Operating Control Panel 5

Installation Manual Tracker 221

Chlorine gas leak detector

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

M2 Rig Monitor Operator s Manual

Universal Gas Detector

Mark 25 Ultrapure Water Conductivity Analyzer

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Table of Contents SECTION PAGE

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Installation, Operating and Maintenance Manual

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

D-Tect 2 GJD300 Quad PIR Movement Detector

User manual and installation guide

Danfoss gas detection unit Type GD Heavy Duty

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

C106 Coded Access Keypad

Is your process protected?

PTE0705 Electric Fence Monitor

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Greentrol Automation, Inc.

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Gas Detection System TOX ALARM DG2000-Garage

DT968C C.T. BATH CONTROLLER

Centro-Matic Automated Lubrication Systems System Controls

Combustible Gas and Hydrogen Sulfide Beacon 200 Rig Monitor Operator s Manual

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Model 6495 Freezing Rain Sensor. User's Manual. All Weather Inc National Drive Sacramento, CA USA

T500 Elite - Hotbus Plant Wide Monitoring System for Bucket Elevators & Conveyors

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Watchdog Elite Watchdog Elite BRAIME Product Information Bucket Elevator & Conveyor Hazard Monitor

Product Manual SZ1145

Danfoss gas detection units

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

INSTALLATION/OPERATION MANUAL WDC3V46C. Revision 1.5 (CSA) January 2007 APPROVALS. The Watchdog Control Unit is approved for use in:

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Beacon 110 Gas Monitor Operator s Manual

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

ECO N DATE DESCRIPTION OF CHANGE CHG

FDF Foam Pump Controllers Features

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Instruction Manual August sitrans CU 02

D-TECT Dual Tech. GJD360 Triple Technology External Detector

FLOW CONTROLLER TYPE S/601

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

CTT8 TEMPERATURE MONITOR DEVICE

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Stand Alone DYNAGARD SP Operation Manual

UV Flame Supervision System

Beacon 800 Gas Monitor Operator s Manual

c0094 form 2. Project Identification Year: 2001 Project nº: 910

Product Manual SZ1144

M2000 Engine Controller

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Beacon 410A Gas Monitor Operator s Manual

LC1350 Level Controller

Transcription:

CALIB CONTINUOUS SPEED INDICATOR EVALUATION UNIT ALRM 1 ALRM 2 ALRM 3 PULSE DISPLAY MESSAGES INSTRUMENT START/RESTART OVERSPEED OCCURED > UNDERSPEED OCCURED < SPEED IS <20 APPROX SPEED DISPLAYED IN PPM(PULSE PER MINUTE) PROG 50/60 Hz CONTACTS SHOWN FOR ALARM IN FAILSAFE HIGH RELAY1 RELAY2 RELAY3 90-260V SENSOR L N E S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 INTERNAL VSUP = 18V DC 0.02 EXTERNAL = VSUP - 4 EXT. SUP. EXT. SUP. = 1K AT EXTERNAL SUPPLY = 24V Users Manual SMART-SSI Continuous Speed Indicator Comprehensive User s Manual. Introduction. General Description. Principle of Operation. Specifications. Connection Diagrams. Key, LED operation. Installation. Quick Calibration Chart. Quick Relay Configuration Chart 131, Palshikar Colony, Indore - 4, India Phone: +91-731-2475751/52/53 email: sales@sapcon.in web: www.sapconinstruments.com

CAUTION: This probe is highly magnetic. Keep it away from magnetosensitive materials such as computer discs and audio or video tapes.

Introduction, Features and Principle of Operation Introduction: SPEED-O-PILOT, MPSSI is an intelligent and versatile speed limit switch suitable for detecting an underspeed condition of rotating, reciprocating or conveying equipment. It can also detect a missing object amongst a series of continuously moving objects moving at a constant speed, such as, a missing bucket in a bucket elevator, a missing object on a conveyor belt etc. It can be used to monitor speed of conveyors and bucket elevators. Special sensor detects moving ferrous objects from 100mm distance. High temperature models up to 200 deg. C are available. The salient features of the instrument are given below. Two underspeed / overspeed alarms, each with an independent relay. An independent relay for missing object/bucket detection. The display latches after detecting underspeed A condition. The display can be reset without opening the enclosure with the help of a magnetic key. Accurate pulse rate (speed) evaluation with optimum response. Easy to install. Flashing LED in the pre-amplifier indicates that the moving target is within the sensing range and facilitates target to detector distance setting. Easy to calibrate. The instrument can be calibrated prior to mounting, if the speed (buckets per minute) of the system is known. Programming is user friendly and menu driven, accomplished by 5 push button keys. 5 digit LED display indicates the speed in ppm (objects per min) and aids in programming. Built-in start-up delay programmable up to 99 sec with provision for interlocking with controlled equipment. Programmable set point and switching hysteresis. Rugged motion detector probe, especially designed for heavy industrial application. Works reliably in dusty environment. 4 LED indicators provided. Green LED indicates receipt of input pulses (when flashing) and 3 red LED s indicate underspeed-a alarm, underspeed-b and missing object alarm. Non-volatile memory stores the program parameters and calibration data indefinitely without the necessity of battery back up.

Technical Specification: EVALUATION UNIT: Alarm mode Measuring range Start-up time delay Programmingvia Indication Relay output Cable entries Housing Operating temp. Power supply underspeed, zero speed, missing object (field selectable) 20 to 9999ppm (pulse per minute) programmable up to 99 sec 4 push button keys yellow LED for power-on, red LED's for alarm, green LED for pulse detection 3 relays, each with one set of potential free c.o. contact (rated at 6A, 230V,AC, 50Hz for non-inductive load), for underspeed, missing object & zero speed detection 3/4 nos. cast aluminium, weatherproof, stoving enamel painted, suitable for back panel/wall mounting -20 to +60 deg. C 90 to 265 VAC Power consumption 5 VA approx. Interlock Dimensions by potential free NO contact of contactor controlling the motor of the monitored equipment overall 180X180X85 mm ELECTRONIC INSERT: Housing plastic with built-in terminals Potting Operating temp. Supply Output PROBE: Probe head Mounting Target range epoxy compound -20 to +80 deg. C 15V DC at 15mA approx. derived from evaluation unit current pulses cast Al weatherproof cast Al flange adjustment by tri-clamp mechanism Max. detection range Target material Min. target area 100mm ferromagnetic 20X20 cm

PRINCIPLE OF OPERATION: The sensor works on the reluctance principle. Whenever the motion detector sensor detects a ferromagnetic target, a signal in the form of a pulse is given to the microprocessor (in the evaluation unit). The microprocessor evaluates the time between consecutive pulses & converts it into ppm. When the speed becomes lower than the programmed 'underspeed' value, underspeed relay changes state. Also, when no pulses are received for the programmed duration of time, zero speed relay changes state. When the system rotates at a constant speed, the time gap between two consecutive pulses remains constant. Now, if an object is missed (pulse is missed), this time gap increases. This is sensed by the microprocessor & it operates the missing object relay. The relay output contacts can in turn be used for signaling/controlling. SYSTEM DESCRIPTION: MOTION DETECTOR PROBE (MDP): It operates on the reluctance principle. The MDP is designed for temperatures up to 150 deg. C standard (200 deg. C special) & has a large sensing range of 100mm. It has SS casing with an Al mounting flange and a tri-clamp arrangement for easy adjustment of target distance. The target should be made up of ferromagnetic material. An electromagnetic shield covers the rear of the probe to minimize interference from stray electromagnetic fields. It is especially designed for heavy industrial applications and works reliably in dusty environments. ELECTRONIC INSERT: Electronic insert consists of an electronic circuitry enclosed in a plastic housing and potted with epoxy compound to render it immune to dust and moisture. It is housed in the cast Al probe head provided with a suitable cable gland, for running the cable. When MDP is suitably installed to sense the moving target, the electronic insert outputs pulses, whose frequency is proportional to the speed of the moving target. These pulses are transmitted to the evaluation unit. EVALUATION UNIT: This consists SMP, That convert 90 to 265 VAC to regulated power supply, that not only provides power to the evaluation unit circuitry but also to the electronic insert in the probe housing. A microcontroller with its firmware processes the signal (transmitted by the PA) intelligently and displays the evaluated speed in ppm (objects/min). A 5 digit 7-segment LED display and its driver circuitry along with 5 push button keys form a user-friendly interactive interface. Various program parameters and calibration data are stored in a non-volatile memory indefinitely without the necessity of battery back up. The stored data can be edited whenever required via the user interface. Adequate cable entries are provided for wiring.

Connection Diagram: Sensor and Power Supply MPILC SMART SSI ALARM 1 ALARM 2 ALARM 3 PULSE CONTINUOUS SPEED INDICATOR EVALUATION UNIT DISPLAY MESSAGES INSTRUMENT START/RESTART OVER-SPEED OCCURRED UNDER-SPEED OCCURRED SPEED IS <20 APPROX CALIB PROG INTERNAL VSUP = 18V DC EXTERNAL = VSUP - 4 0.02 EXT. SUP. 50/60 Hz CONTACTS SHOWN FOR ALARM IN FAILSAFE HIGH RELAY1 RELAY2 RELAY3 90-260V L N E EXT. SUP. = 1K AT EXTERNAL SUPPLY = 24V SENSOR S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 CONTACT Short both terminal when no any external contact 90 TO 265VAC 50/60Hz Always connect the Ground to the GND terminal of the Evalaution Unit. This is required for AC as well as DC supply. For length longer than 10 meters and also in electrically Noisy environments, Use Shielded Twisted Pair Cable SDI-351 Ground the Shield 141312 0 S + 1 2 3 4 5 6 TO COIL S. No. INST. PVT. LTD. 1 2 3 4 5 6 W-01

Connection Diagram: Combinations Internal Isolated DC Power Supply: MPILC Terminal PLC input Indicator input RL Internal Isolated Supply is Guaranteed to 18VDC (min) RLmax=700 Ohm While using the Internal Supply External DC Power Supply (RL to ): MPILC Terminal External DC Supply External Supply can be the same 24VDC supply which is used to power the MPILC. PLC input Indicator input RL RLmax=1K Ohm for External Supply=24VDC External DC Power Supply (RL to Negative): MPILC Terminal External DC Supply External Supply can be the same 24VDC supply which is used to power the MPILC. PLC input Indicator input RL RLmax=1K Ohm for External Supply=24VDC Loop Resistance = ( Loop Supply Voltage 4) 0.02 (Ohm) W-02

KEYS USED & THEIR OPERATION: CALIB Press and hold to enter in calibration menu till CALB not displayed. Press ENTER to change parameter or press CALIB key to exit from menu. PROG Press and hold to enter in relay setting till PROG not displayed. Press ENTER to change parameter or press PROG key to exit from menu. Request to instrument for change parameter or apply displayed command press ENTER key. To increment menu or data press UP key in programming mode. To decrement menu or data press DOWN key in programming mode. Note: Changed parameter save only when ENTER apply after change. LED & ALARM INDICATION: ALRM 1 ALRM 2 ALRM 3 PULSE Alarm-1 LED associated with Relay-1. Alarm-2 LED associated with Relay-2. Alarm-3 LED associated with Relay-3. Relay 1&2 program by user Relay -3 for missing object detection PULSE LED indicate the pulse detect when bucket passing near sensor Fail Safe High or Maximum Fail Safe Alarm Start:- Displayed value < Low Set value - Low hysteresis & Displayed value > High Set value - High hysteresis Alarm Stop:- Displayed value > Lower Set value Displayed value < High Set value Fail Safe Low or Minimum Fail Safe Alarm Start:- Displayed value > Low Set value - Low hysteresis & Displayed value < High Set value - High hysteresis Alarm Stop:- Displayed value < Lower Set value Displayed value > High Set value Relay-3 latch when any bucket found missing it will be disable through magnetic key at given place. During Alarm Relay is at NC (Normally Connected) Relay LED Glows (Red) During No Alarm Relay is at NO (Normally Open) Relay LED Turns Off NC NO POLE NC NO POLE

INSTALLATION: MOTION DETECTOR PROBE: Refer to the drawings for mounting details. The probe should be mounted, as close to the moving objects as is possible taking care that the moving objects do not strike the probe. When used on elevators it is preferable to mount the probe up at the driving wheel where the deflection of the chain is a minimum. The distance of the moving objects should not exceed the specified sensing range from the sensitive face of the probe. When the moving target is within the sensing range, a LED provided in the pre-amplifier starts flashing. Aluminium mounting flange and a tri-clamp arrangement, allow easy adjustment of target distance. SDI-351 TO COIL141312 0 S + 1 2 3 4 5 6 S. No. INST. PVT. LTD. 1 2 3 4 5 6 ELECTRONIC INSERT: For integral mounting, the electronic insert is already mounted in the probe head when shipped. It is fixed in the probe head by means of a single screw at the center of the electronic insert. For remote mounting, the electronic insert is mounted in a separate housing suitable for wall mounting when shipped. It is supplied with a PTFE screened cable of 1.5m length already connected to the electronic insert in a separate housing. The open end of the cable has to be connected with the terminals provided in the probe head. The remote housing should be installed as close to the probe as possible. The electronic insert in both types of installations should in no case be subjected to excessive heat due to hot environment or due to the direct impingement of sunrays. The temperature inside the electronic insert should not exceed 80 deg.c due to any reason. EVALUATION UNIT: The evaluation unit is suitable for back panel or wall mounting. Refer to the mounting details diagram for hole locations in the back panel and drill holes accordingly. Remove instrument cover by unscrewing the four screws provided on front cover. Box fixing holes will be clearly visible on the box bottom, above and below card. Mounting hardware consists of 4 nos. of M4 cheese head screws with rubber O rings, to render the box dust tight after fitting. After installation the cover should be re-fitted to avoid dust ingression. The housing is suitable for outdoor installation. However, in no case should the instrument be subjected to temperature exceeding 60 deg.c. Though the instrument can be installed outdoor, it should never be subjected to direct sunrays. Preferably a sunshade should be provided.

START-UP DISPLAY: Display init whenever instruments power on or restart. Startup time set on menu. SMART SSI ALARM 1 ALARM 2 ALARM 3 PULSE CONTINUOUS SPEED INDICATOR EVALUATION UNIT DISPLAY MESSAGES INSTRUMENT START/RESTART OVER-SPEED OCCURRED UNDER-SPEED OCCURRED SPEED IS <20 APPROX CALIB PROG INTERNAL VSUP = 18V DC EXTERNAL = VSUP - 4 0.02 EXT. SUP. 50/60 Hz CONTACTS SHOWN FOR ALARM IN FAILSAFE HIGH RELAY1 RELAY2 RELAY3 90-260V L N E EXT. SUP. = 1K AT EXTERNAL SUPPLY = 24V SENSOR S After startup its display current PPM (pulse per minute). Displayed value up to 9999. SMART SSI ALARM 1 ALARM 2 ALARM 3 PULSE CONTINUOUS SPEED INDICATOR EVALUATION UNIT DISPLAY MESSAGES INSTRUMENT START/RESTART OVER-SPEED OCCURRED UNDER-SPEED OCCURRED SPEED IS <20 APPROX CALIB PROG INTERNAL VSUP = 18V DC EXTERNAL = VSUP - 4 0.02 EXT. SUP. 50/60 Hz CONTACTS SHOWN FOR ALARM IN FAILSAFE HIGH RELAY1 RELAY2 RELAY3 90-260V L N E EXT. SUP. = 1K AT EXTERNAL SUPPLY = 24V SENSOR S

CALIBRATION: > It is Offline calibration CALIB > For enter in MAIN menu press and hold CALIB key till calb not displayed in screen.. > After displayed calb press enter key.. CALIB Press and hold Value Limit Startup delay User define the startup time to initializations of the system. Its displayed last saved value. 01-99 Pre-scalling Scaling the value from the no. Of bucket to know the RPM of gear. 01-99 Lower limit Higher limit Display Update Set the lower limit of value(bucket per minute) for 4 ma. It should be less than higher value. At a time only two digit change Set the Higher limit of value(bucket per minute) for 20 ma. It should be higher than lower value. At a time only two digit change Define the display update time on 7- segment. 01-9999 01-9999 0.5-3.0 Press Enter to save changed value Changed parameter saved press enter again Exit from menu. Display front view.

Value Limit RELAY PROGRAMMING: PROG Press and hold Blink digit 1 Select 1 or 2 through UP or DOWN key Set lowest value to generate alarm condition 01-9999 Set Higher value to generate alarm condition 01-9999 Hysterisys for lowest value to Normal alarm condition 00-99 Hysterisys for Higher value to Normal alarm condition 00-99 Set lowest value to generate alarm condition Press Enter to save changed value Changed parameter saved press enter again Exit from menu. Display front view.

CALIB CONTINUOUS SPEED INDICATOR SMART SSI EVALUATION UNIT ALARM 1 ALARM 2 ALARM 3 PULSE DISPLAY MESSAGES INSTRUMENT START/RESTART OVER-SPEED OCCURRED UNDER-SPEED OCCURRED SPEED IS <20 APPROX PROG 50/60 Hz CONTACTS SHOWN FOR ALARM IN FAILSAFE HIGH RELAY1 RELAY2 RELAY3 90-260V L N E SENSOR S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 INTERNAL VSUP = 18V DC 0.02 EXTERNAL = VSUP - 4 EXT. SUP. EXT. SUP. = 1K AT EXTERNAL SUPPLY = 24V Note:- There is three independent relay. Relay 1& 2 for user define lower and higher speed alarm indication Relay 1&2 is two point alarm condition. ALARM condition:- Displayed Value >Higher Value OR Displayed Value <Lower Value Both condition generate Alarm for relay 1&2. Normal Condition:- For Auto mode:- Displayed Value < Higher Value-Hysterisys And Displayed Value > Lower Value+ Hysterisys For Manual Mode:- User reset Alarm manually through restart evaluation Unit or through magnet at given point. Alarm 3: Indicated by relay 3. Its indicate the missing object (bucket) between two consecutive bucket. Fall from here Give Alarm through Relay 3 Note:- Alarm 3 use very carefully.

INSTALLATION:

INSTALLATION: