DESIGN GUIDE B U I L T- I N S E R I E S F L U S IN S E T O V E R L A Y EFFECTIVE 1/4/2017
TA B L E O F C O N T E N T S 3 B U I L T- I N R E F R I G E R A T I O N F L U S I N S E T O V E R L AY I N S TA L L AT I O N SUB-ZERO ARRANTIES Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3.
Built-In Refrigeration Sub-Zero designers and engineers continue to perfect the built-in line. The addition of LED lighting throughout and several new models with internal water dispensers, along with the same advanced food preservation technology Sub-Zero is known for, make the built-in line nothing short of revolutionary. BUILT-IN MODELS ICBBI-36R ICBBI-36F ICBBI-36UID ICBBI-36S ICBBI-42S ICBBI-4S ICBBI-4SID ICBBI-4SD 3
Overall Dimensions ALL REFRIGERATOR ALL FREEZER OVER-AND-UNDER 914 665 914 665 173 2134 129 2134 54 EIGT DIMENSIONS ± 13 102 606 EIGT DIMENSIONS ± 13 102 606 606 606 359 359 946 600 946 60 60 Model ICBBI-36R, ICBBI-36F. Model ICBBI-36UID. Overall dimensions are based on stainless steel models. For flush inset applications, add minimum 13 to door clearance dimensions. 4
Overall Dimensions SIDE-BY-SIDE 914 665 1067 665 2134 2134 173 173 EIGT DIMENSIONS ± 13 102 606 EIGT DIMENSIONS ± 13 102 606 606 606 14 222 191 264 565 66 60 60 Model ICBBI-36S. Model ICBBI-42S 5
Overall Dimensions SIDE-BY-SIDE 1219 173 2134 665 Specifications INTERIOR CAPACITY ALL REFRIGERATOR ALL FREEZER R (L)* F (L)* ICBBI-36R 613 ICBBI-36F 612 OVER-AND-UNDER R (L) F (L) ICBBI-36UID 367 143 ICBBI-36UFDID 357 144 ICBBI-42UFDID 420 220 SIDE-BY-SIDE R (L) F (L) ICBBI-36S 32 225 ICBBI-42S 430 220 ICBBI-42SD 40 194 ICBBI-4S 500 264 ICBBI-4SID 491 244 ICBBI-4SD 47 244 *Useable volume based on ISO 15502 EIGT DIMENSIONS ± 13 102 606 213 295 606 762 60 Model ICBBI-4S, ICBBI-4SID, ICBBI-4SD. 6
Flush Inset Overlay Panels overlay application. FLUS INSET PANEL SPACER PANEL BACKER PANEL PANEL REQUIREMENTS PANEL EIGT ICBBI-36R/O, ICBBI-36F/O MAX 34 kg 19 typical 3 6 All Other Models 23 kg Grille Panel 6 kg PANEL TICKNESS MIN All Panels 16 7
Opening Dimensions FLUS INSET OVERLAY INSTALLATION 675 FLUS INSET DEPT 56 FINISED CLEATS* TOP VIE 6 32 2134 FLUS INSET EIGT FLUS INSET IDT 32 102 76 * TYPICAL 56 SIDE VIE FRONT VIE *76 typical depth. Shaded areas will be visible and should be finished to match cabinetry. NOTE: Shaded line represents profile of unit with19 panel. FLUS INSET OVERLAY IDT ICBBI-36R/O, ICBBI-36F/O ICBBI-36UID/O, ICBBI-36S/O ICBBI-42S/O ICBBI-4S/O, ICBBI-4SID/O, ICBBI-4SD/O 965 965 111 1270 Dimensions assume a 19 panel thickness. If two units are installed side by side, refer to page 1 for dual flush inset installations.
Planning information DIRECTION. Ensure water connection is ½ BSP male 1. 1. FRONT VIE 17 E 2,200 minimum FROM FLOOR pressure limiting valve 6 flexi hose & tape to wall & floor. pressure limiting valve 6 flexi hose & tape to wall & floor. 2. 2. 191 FROM FLOOR 152 9
Custom Panels FLUS INSET OVERLAY PANELS The flush inset application is an overlay model with flush inset panels. It is not a separate model. The flush inset design allows custom panels to be installed flush with adjacent cabinets. Similar to overlay, flush inset panels are typically created by combining a 19 custom panel, a 3 spacer panel and a 6 backer panel. Refer to the illustrations for overlay panels. Panels must be fixed together prior to installation. ICE ATER DISPENSER For model ICBBI 4SD/O, the refrigerator door panel must include a cut-out to accoodate the external dispenser. The thickness of the panel in this area can range from 6 to a maximum of 29. Refer to the illustrations below. For flush inset panels thicker than 19, a 90 door stop may be required to prevent interference with adjacent cabinets. Refer to the full-scale templates at the end of this guide. 16 160 2 hen installing two units side by side, refer to page 1 for dual flush inset installations. 3 RADIUS 51 ANDLE GLASSELL 327 25 Dispenser dimensions. andle placement. 10
Flush Inset Overlay Panel Dimensions ICBBI-36R/O, ICBBI-36F/O ICBBI-36UID/O MODEL ICBBI-36R/O, ICBBI-36F/O REFRIGERATOR FREEZER Flush Inset Panel 940 1772 Spacer Panel 92 1751 Backer Panel 90 1767 GRILLE Flush Inset Panel 940 235 Spacer Panel 92 211 Backer Panel 90 227 MODEL ICBBI-36UID/O REFRIGERATOR Flush Inset Panel 940 1273 Spacer Panel 92 1253 Backer Panel 90 126 FREEZER Flush Inset Panel 940 43 Spacer Panel 92 459 Backer Panel 90 475 GRILLE Flush Inset Panel 940 235 Spacer Panel 92 211 Backer Panel 90 227 11
Flush Inset Overlay Panel Dimensions A B ICBBI-36S/O, ICBBI-42S/O, ICBBI-4S/O, ICBBI-4SID/O ICBBI-4SD/O MODEL ICBBI-36S/O REFRIGERATOR Flush Inset Panel 522 1772 Spacer Panel 47 1751 Backer Panel 503 1767 FREEZER Flush Inset Panel 411 1772 Spacer Panel 376 1751 Backer Panel 392 1767 GRILLE Flush Inset Panel 940 235 Spacer Panel 92 211 Backer Panel 90 227 MODEL ICBBI-42S/O REFRIGERATOR Flush Inset Panel 649 1772 Spacer Panel 614 1751 Backer Panel 630 1767 FREEZER Flush Inset Panel 437 1772 Spacer Panel 402 1751 Backer Panel 41 1767 MODEL ICBBI-4S/O, ICBBI-4SID/O, ICBBI-4SD/O REFRIGERATOR Flush Inset Panel 743 1772 Spacer Panel 70 1751 Backer Panel 724 1767 FREEZER Flush Inset Panel 495 1772 Spacer Panel 460 1751 Backer Panel 476 1767 GRILLE Flush Inset Panel 1245 235 Spacer Panel 1197 211 Backer Panel 1213 227 DISPENSER (ICBBI-4SD/O) Cut-Out 149 316 Cut-Out Location 51 732 Grille panel dimensions are for standard 2134 overall unit height. A B GRILLE Flush Inset Panel 1092 235 Spacer Panel 1045 211 Backer Panel 1060 227 12
Flush Inset Overlay Panels PANEL OFFSET TOP VIE TOP VIE The illustrations provide panel offsets and reveals for built-in models in a flush inset application. Refer to the chart below for reference to the illustrations. PANEL OFFSET DOOR / DRAER / GRILLE BACKER SPACER CABINETRY DOOR DOOR ALL REFRIGERATOR ALL FREEZER Door Grille Sides Grille Top Grille Bottom Door Top Door Bottom ILLUS A C D F FLUS INSET PANEL 13 16 3 6 REVEAL OVER-AND-UNDER Door Drawer Grille Sides Grille Top Grille Bottom Door Top Door Bottom Drawer Top Drawer Bottom SIDE-BY-SIDE Doors (hinge) Grille Sides Doors (handle) Sides Grille Top Grille Bottom Door Top Door Bottom ILLUS A C D E F ILLUS A B C D F Illus. A CABINETRY GRILLE 3 13 Illus. B GRILLE DOOR 4 2 13 SIDE VIE SIDE VIE Illus. C Illus. D DOOR 2 DOOR / DRAER 16 DRAER 4 SIDE VIE SIDE VIE 2 Illus. E Illus. F 13
Dual Installation If two units are installed side by side, a dual installation kit may be required. Installations without a custom filler strip require a dual installation kit. If a dual installation kit is not specified, a 51 filler strip is recoended between units. A custom filler strip is required when installing two French door or side-by-side models. Dual installations without a filler strip can only be accomplished using two units with opposite hinges. Refer to the illustrations below. Dual installation kits are available through an authorized Sub-Zero dealer. For questions regarding the installation, contact your authorized Sub-Zero dealer. ITOUT FILLER STRIP FILLER STRIP Opposite hinges. Same side hinges. 14
Opening Dimensions DUAL FLUS INSET OVERLAY INSTALLATION 675 FLUS INSET DEPT 56 FINISED CLEATS* TOP VIE 6 32 2134 FLUS INSET EIGT FLUS INSET IDT 32 102 76 * TYPICAL 56 SIDE VIE FRONT VIE *76 typical depth. Shaded areas will be visible and should be finished to match cabinetry. NOTE: Shaded line represents profile of unit with19 panel. FLUS INSET IDT Two 914 Models 16 Dimensions assume a 19 panel thickness. A dual installation kit will be required for this installation in a handle to handle situation only. here a dual installation kit is not used or the installation is a handle to hinge or hinge to hinge, a 51 spacer panel is required between the refrigerators. 15
Dual Flush Inset Overlay Panel Dimensions ICBBI-36R/O, ICBBI-36F/O ICBBI-36UID/O MODEL ICBBI-36R/O, ICBBI-36F/O REFRIGERATOR FREEZER Flush Inset Panel 927 1772 Spacer Panel 92 1751 Backer Panel 90 1767 GRILLE Flush Inset Panel 927 235 Spacer Panel 92 211 Backer Panel 90 227 MODEL ICBBI-36UID/O REFRIGERATOR Flush Inset Panel 927 1273 Spacer Panel 92 1253 Backer Panel 90 126 FREEZER Flush Inset Panel 927 43 Spacer Panel 92 459 Backer Panel 90 475 GRILLE Flush Inset Panel 927 235 Spacer Panel 92 211 Backer Panel 90 227 Grille panel dimensions are for standard 2134 overall unit height. For dual wide grilles, refer to page 21. 16
Dual Installation DUAL FLUS INSET OVERLAY PANEL OFFSET TOP VIE TOP VIE The illustrations provide panel offsets and reveals for built-in models in a dual flush inset application. Refer to the chart below for reference to the illustrations. PANEL OFFSET DOOR / DRAER / GRILLE BACKER SPACER CABINETRY DOOR DUAL TRIM DOOR ALL REFRIGERATOR ALL FREEZER Door (hinge) Grille Sides Door (handle) Sides Grille Top Grille Bottom Door Top Door Bottom OVER-AND-UNDER Door (hinge) Drawer Grille Sides Door (handle) Sides Grille Top Grille Bottom Door Top Door Bottom Drawer Top Drawer Bottom ILLUS A B C D F ILLUS A B C D E F FLUS INSET PANEL Illus. A CABINETRY GRILLE 13 16 3 13 3 Illus. B GRILLE 6 REVEAL 4 13 DOOR 2 SIDE VIE SIDE VIE Illus. C Illus. D DOOR 2 DOOR / DRAER 16 DRAER 4 SIDE VIE SIDE VIE 2 Illus. E Illus. F 17
Dual Installation DUAL IDE GRILLE A dual wide grille spans the entire width of both units in a dual installation and is a part of a dual installation kit. For flush inset panel dimensions for the dual wide grille, refer to the charts below. Dimensions listed are for a standard 2134 finished height. DUAL IDE GRILLE FLUS INSET OVERLAY TO 914 MODELS Flush Inset Panel 161 235 Spacer Panel 113 211 Backer Panel 129 227 1
Overlay Flush Inset Panels FULL-SCALE TEMPLATE Overlay and flush inset panels must be a minimum of 16 thick to support mounting the handle. Panel thickness does not include backer and spacer panel. Mount handle close to the opening edge of the door. DEPT OF TUBULAR AND PRO ANDLES 25 51 76 32 PANEL 25 PANEL 19 PANEL 3 SPACER PANEL 6 BACKER PANEL DOOR Overlay and flush inset panel thickness. 19
Flush Inset Overlay Application FULL-SCALE TEMPLATE For panels thicker than 19, a 90 door stop may be required to prevent interference with adjacent cabinets. 610 TO BACK ALL 32 56 ASSUMES 19 FLUS INSET PANEL TICKNESS 25 TICK PANEL 19 TICK FLUS INSET PANEL (TYPICAL) 6 BACKER PANEL 0 25 SCALE 110 door opening (top view). 20
FILLER STRIP 3 13 PROFILE OF 19 FLUS INSET PANEL AND TUBULAR ANDLE DOOR CLOSED Dual Flush Inset Overlay Installation FULL-SCALE TEMPLATE DOOR OPEN 110 Typical flush inset dual installation with filler strip at maximum 110 door opening. Panel thickness may require a 90 door stop. 0 25 SCALE Dual flush inset installation (top view). 21
Sub-Zero International Limited arranty FOR RESIDENTIAL USE FULL TO YEAR ARRANTY* For two years from the date of original installation, this Sub-Zero product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Sub-Zero under the above warranty must be performed by Sub-Zero factory certified service, unless otherwise specified by Sub-Zero, Inc. Service will be provided during normal business hours. FULL FIVE YEAR SEALED SYSTEM ARRANTY For five years from the date of original installation, this Sub-Zero product warranty covers all parts and labor to repair or replace, under normal residential use, these parts that prove to be defective in materials or workmanship: compressor, condenser, evaporator, drier and all connecting tubing. All service provided by Sub-Zero under the above warranty must be performed by Sub-Zero factory certified service, unless otherwise specified by Sub-Zero, Inc. Service will be provided during normal business hours. For more information regarding your Sub-Zero product warranty, contact your authorized Sub-Zero dealer. arranties must comply to all country, state, city, local and or ordinance. *Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited 60-day parts and labor warranty for cosmetic defects. *Replacement water filters and air purification cartridges are not covered by the product warranty. Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowflake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, olf, olf & Design, olf Gourmet, & Design, red colored knobs, Cove, and Cove & Design, are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries. All other trademarks are property of their respective owners in the United States and other countries. 22
Bank ouse, 11 19 Bank Place. Melbourne Victoria Australia 3000 Telephone 03 9600 221 enquiries@subzero.com SUBZERO-OLF.COM.AU V2