LARGE CAPACITY HEATERS

Similar documents
MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS

ADF/ADFH 300 and 500

FEATURES AND BENEFITS

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air

Gas-Fired Indoor and Outdoor Duct Furnaces

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

Heating & Ventilation Product Line

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

Indirect Gas-Fired Make-Up Air

Direct Fired Heater Model AD Specification

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

THE RIGHT SPEC. RIGHT NOW.

Direct Gas-Fired Make-Up Air

Gas-Fired Indoor and Outdoor Duct Furnaces

Heating & Ventilation Product Line

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

Modular Heating & Ventilating Unit Model IGX-HV

LIGHT COMMERCIAL. Packaged Units and Split Systems APPLICATIONS: OFFICES RETAIL STORES RESTAURANTS CLINICS

SUBMITTAL SCHEDULE & DATA

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Submittal Data Performance Data Electrical Data

GLOBAL FINISHING SOLUTIONS

VariCool VAV Engineering Guide

Product Catalog Gas Heating Products: Indoor and Outdoor Units

CATALOG: HVAC - Gas Space Unit Heating

DOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

bring value to your space

True performance and rugged durability. TU, LF and LD Models

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

The H Series. Pure and Simple Solutions. HTLV Space Heating

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

GARAGE / WORKSHOP INFRARED HEATERS

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

PACKAGED HVAC EQUIPMENT CATALOG

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Cooling & Ventilation Product Line

Gil Rossmiller. In the construction industry for over 30 years. ICC IRC Plumbing & Mechanical Code Development Committee

Make-Up Air Systems. Performance. Model DGK, DG, DGX

AND WORRY-FREE PERFORMANCE

48TM GAS HEATING/ELECTRIC COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

SKYPAK II, 3 Ton Series, gives you a

Air-Handling System Cooling Options

HVAC Equipment Access Equipment Location

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

HVAC HEATING PRODUCTS

HIGH-EFFICIENCY FURNACES

HIGH EFFICIENCY FURNACES Built Exclusively for Manufactured Housing

Inspection Checklist Mechanical Rough in

62DA,DB,DC,DD,DE,DF07-38

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

VENTING VENTING OF INDIRECT GAS FIRED AND OIL FIRED HEATING APPLIANCES INDOOR GRAVITY VENTED UNIT HEATERS AND PACKAGED SYSTEMS

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

8+* Bulletin No November 1997

HVAC EQUIPMENT for Residential, Industrial & Commercial Applications GACP-22

SKYPAK II, 3 Ton Series, gives you a

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Energy Recovery with Cooling and Heating Model ERCH

Owner s Information Manual

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

SKYPAK II Heating & Cooling Self Contained Packages

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Energy Recovery with Cooling and Heating

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

GARCIA GALUSKA DESOUSA Consulting Engineers

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Air-Handling System Cooling Options

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

REPLACEMENT PARTS LIST

Job Name Control Systems Description Date

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

KIC Air Curtains. Technical Guide

PROVIDING HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Counterflo CF BASIC COUNTERFLO HEATER RCF CURB MOUNTED ROOFTOP HEATER CFDF COUNTERFLO DUCT FURNACE INDIRECT-FIRED INDUSTRIAL HEATERS

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

Make-Up Air March 2012

TECHNICAL SPECIFICATIONS

Transcription:

250 1,000 Capacities 7.5-12,850 150,000 CFM 200 MBH 250-7,500 MBH - - Tons APPLICATIONS Heating/Cooling/Makeup Air WAREHOUSES / FACTORIES SCHOOLS / UNIVERSITIES COMMERCIAL / RETAIL INDUSTRIAL GYMNASIUMS / FITNESS CENTERS CHURCHES / MEETING HALLS COMMUNITY CENTERS ARENAS LARGE CAPACITY HEATERS ReznorHVAC.com

1,000-150,000 CFM Air Handlers Large capacity applications can be very specialized. Many manufacturers offer only one type of large air volume unit. Don t fit your project around the HVAC equipment. With Reznor HVAC equipment, you get your choice: Direct or indirect fired Indoor or outdoor installation Vertical or horizontal discharge air Vertical or horizontal cabinetry Air turnover equipment Reznor high air volume equipment is pre-engineered and cataloged. This gives you quick performance, submittal and specification information at your fingertips. The range and features of Reznor high air capacity units make them ideally suited for space conditioning, makeup air or process applications such as: Agriculture curing, heating and ventilating Kitchen and laboratory makeup air Paint booths makeup air and drying Industrial process heating SELECTION GUIDE Air Volume (CFM) Heating Capacity (MBH) Indoor / Heating with Evaporative with Chilled Separated Model Outdoor Only with DX Cooling Cooling Water Cooling Direct Fired Indirect Fired Combustion RPBL Outdoor 3,300-14,000 4,000-8,000 4,000-8,000 4,000-8,000-400 - 1,200 - SSCBL Indoor 3,300-13,500 4,000-8,000 4,000-8,000 4,000-8,000 - - 400-1,200 RDF Indoor/Outdoor 1,000-28,000 - - - 400-3,000 - - ADF Indoor/Outdoor 2,000-15,500-2,000-15,500-500 - 1,250 - - ADFH Indoor/Outdoor 2,000-15,500-2,000-15,500-500 - 1,250 - - DFC Indoor/Outdoor 20,000-90,000 20,000-90,000 20,000-90,000 20,000-90,000 4,000-12,800 - - AEB Indoor/Outdoor 3,250-150,000 3,250-150,000-3,250-150,000-250 - 7,500 - PCD Indoor/Outdoor 1,700-110,000 1,684-110,000 1,684-110,000 1,684-110,000-250 - 7,500 - HPCD Indoor/Outdoor 3,100-140,000 3,086-140,000 3,086-140,000 3,086-140,000-250 - 7,500 - Value Reznor high capacity air handlers are engineered to provide the best value per cfm. This is evident by the number of national and international corporations that have chosen Reznor equipment for their factories and office buildings. Our customers include internationally known automobile manufacturers, aerospace manufacturers, electronics manufacturers, food and medicine producers.

Indoor/Outdoor Custom Equipment Model DFCH Model AEB TECHNICAL DATA The Reznor line offers a complete package of ultra high volume air handlers for vertical and horizontal applications. 100% outside air Mixed air control Space heating Air turnover Features & Options Natural gas, propane, electric, steam, hot water or fuel oil 208-230V/1, 208-230V/3, 460V/3, 575V/3 8 different makeup air, space and discharge air controls 14 or 16 gauge cabinet construction Standard or high density insulation Multiple configurations for inlets and discharge with dampers Inlet louvers and filters 5-75 hp motors Variable frequency drive Vibration isolation Cooling - DX, chilled water or evaporative cooling Stainless steel heat exchanger Disconnects Roof curbs Remote console Cooling Types Heating Fuels Heating DX Evaporative Chilled Natural Steam / Model Arrangement Source CFM (MBH) Cooling Cooling Water Gas Propane Hot Water Electric Fuel Oil DFCH Horizontal Direct Fired 20,000-90,000 1,400-12,830 P P P P P DFCV Vertical Direct Fired 20,000-90,000 1,400-12,830 P P P P P PCDH Horizontal Power Burner 1,700-110,000 250-7,500 P P P P P P P PCDV Vertical Power Burner 1,700-110,000 250-7,500 P P P P P P P HPCDH Horizontal Power Burner 3,100-140,000 250-7,500 P P P P P P P HPCDV Vertical Power Burner 3,100-140,000 250-7,500 P P P P P P P AEB Vertical Air Turnover 3,250-150,000 250-7,500 P P P P P P P Horizontal Arrangements Air Flow Configurations Some jobs are constrained by the air flow and duct work. Reznor air handlers make it easy to apply the units, even in the most difficult of applications. Units can be floor mounted for easy access. If floor space is at a premium, most units can be suspended, mounted on the roof, or pad mounted outside the building with discharge air ducted inside. See configurations at right. Vertical Arrangements

Indirect Fired Reznor indirect fired air handlers provide heating/cooling for comfort; makeup air for exhaust; or ventilation air for improved indoor air quality (IAQ). This makes these units ideal for Factories Animal shelters Schools Retail stores Locker rooms Indoor Mounted Units Indoor indirect fired units give you the right amount of heat just where you need it. All units can be floor or ceiling mounted. Model SSCBL is a separated combustion unit. Up to 130 F temperature rise Over 2 external static pressure 80% thermally efficient Custom DX & chilled water coils The Advantages of Separated Combustion Model RPBL units are specifically designed for outdoor applications. They can deliver up to 100% outside air for make-up air or space conditioning. The weatherproof cabinet gives you worry-free performance. An air intake hood includes moisture elimination louvres. The robust indirect fired burner design allows the units to be used for general ventilation applications for occupied spaces. Up to 120 F temperature rise Over 2 external static pressure 80% thermally efficient Custom DX & chilled water coils Reznor separated combustion system technology eliminates common open flame combustion problems such as contaminants in the indoor air and negative building air pressure. Outdoor Mounted Units Air for combustion is taken from outside the building, preventing dirt, lint, dust or other contaminants in the indoor atmosphere from being burned. The combustion air flow is unaffected by negative building pressure or wind which can cause nuisance shutdown. Only one building penetration, horizontal or vertical (see the illustration at right).

Features & Options ANSI Z83.8 CSA 2.6 Model RPBL Features Natural gas or propane Aluminized steel heat exchanger Power vented Intermittent spark pilot Twin centrifugal blowers Gas control safeties Motor starter Curb cap base Suspension hangers (Model SSCBL only) 208-230V/1, 208-230V/3, 460V/3, 575V/3 voltage Downturn plenum (Model RPBL only) Filter rack with 2 filters Options 409 stainless steel heat exchanger 409 stainless drip pan Heat Controls (makeup air/discharge air) 6 stages Modulation, 2:1 through 12:1 Thermostat control Single or double wall insulated construction Intermittent spark pilot with timed lockout Horizontal or vertical discharge Discharge dampers Horizontal and/or vertical Inlets Multiple damper control options Open dripproof or TEFC motor (motors meet EISA specifications for efficiency) Variable frequency drives High and low gas pressure switch Firestat and freezestat high ambient cutoff Convenience outlet Cooling cabinet with DX or chilled water coil (16-50 tons) Evaporative cooling module Disconnect switch - UL Listed Outside air hood (Model RPBL only) Roof curbs (Model RPBL only) TECHNICAL DATA Heating Only Heating & Capacity (MBH) Separated Model CFM Cooling CFM Installation 400 500 600 700 800 1050 1200 Combustion SSCBL 3,300-14,000 4,000-8,068 Indoor P P P P P P P P RPBL 3,300-14,000 4,000-8,068 Outdoor P P P P P P P Advantages of Indirect Fired Units Proven and robust Thermocore heat exchanger - over 1.5 million units installed since 1963 80% thermally efficient Heated air without the carbon monoxide or other flue gases in the air stream Allows up to 6 stages of control or up to 12:1 modulation for demanding applications Thermocore Heat Exchanger

Indoor/Outdoor Air Handlers - Direct Fired Models ADF, ADFH and RDF are specifically designed to deliver up to 100% outside air for process make-up air or general ventilation. The robust direct fired burner units are an economical way to meet the heating needs of your applications. Up to 130 F temperature rise Maintain 160 F discharge air Over 2 external static pressure 92% thermal efficient Model RDF allows up to 75% recirculation air Model ADF Features Natural gas or propane Hot surface ignition system Motor starter Curb cap base with suspension hangers 208-230V/1, 208-230V/3, 460V/3, 575V/3 Insulated cabinet construction Options CSA 3.7 ANSI Z83.4 Non-Recirculating Double wall insulated construction Control options for makeup air & discharge air Thermostat control Horizontal or vertical discharge Discharge dampers Single-stage, two-stage or electronic modulation gas control Multiple damper control options Open dripproof or TEFC motor (motors meet EISA specifications for efficiency) Variable frequency drives High and/or low gas pressure switches Firestat and freezestat high ambient cutoff Convenience outlet Makeup air controls/dampers Evaporative cooling module Exhaust fan overhead door interlock Roof curb Outside air hood with filters Filter rack for 2 filters Disconnect switch - UL Listed Industrial Air Heaters ANSI Z83.18 Recirculating Industrial Air Heaters Air Volume Maximum Maximum Discharge Maximum Heating Capacity (MBH) by Size Model Range (CFM) Temp. Rise ( F) Air Temp ( F) 1-20 1-40 1-50 1-65 2-80 2-120 2-180 3-260 RDF 1,000-28,000 120 120 400 600 750 750 1500 1500 2500 3000 Air Volume Maximum Maximum Discharge Maximum Heating Capacity (MBH) by Size Model Range (CFM) Temp. Rise ( F) Air Temp ( F) 300 500 700 1200 ADF 2,000-15,500 130 120 500 750 1250 1250 ADFH 2,000-15,500 130 160 500 750 1250 1250 Advantages of Direct Fired Heating Equipment When you need a heating solution for large volumes of ventilation air, then direct fired units may be the right solution. Direct fired heating equipment offers: Good heat-to-air volume value High thermal efficiencies approaching 92% Excellent temperature control with 25:1 modulation capabilities No venting or flue piping required

Cooling Condensing Units for DX Cooling Coils Reznor Model MASA condensing unit is designed to match the cooling capacities for Reznor air handling units. Environmentally conscious Energy saving - allows three capacity stages to match changes in load demand Sustainable - up to 12.3 EER Ozone friendly - R410A refrigerant Easy installation and service Dependable Safety certified Capacity modulation INTERTEK CM Model MASA C L I S T E D UL1995 CSA 22.2 US Evaporative Cooling Are you dealing with an area containing equipment or a process that constantly creates excessive heat? How about an area requiring makeup air during the hot summer months? Then you know that, unfortunately, making these areas comfortable with traditional mechanical cooling can be an expensive proposition. So you re stuck with a tough choice - mechanical cooling or no cooling at all...unless you decide on a Reznor evaporative cooling system. Using evaporative cooling is also comfortable to the people paying the monthly energy bill. Evaporative Cooling Module Evaporative cooling is ideal for: Factories / industrial applications Agricultural buildings Garages / welding shops Commercial kitchens Foundries Laundromats / dry cleaners How Evaporative Cooling Works Ever notice how your body cools off when you first step out of a pool? This is caused by water evaporating off your skin. When water changes from a liquid to a vapor, it absorbs energy - heat energy. So when it evaporates, it takes heat away from your body. You re left feeling cool. This is very much like what happens in a Reznor evaporative cooling system. Adiabatic cooling using high tech media pads can be 80% efficient. If the difference between dry bulb and wet bulb temperatures is 12 F, there will be a 10 F drop in the sensible temperature. Blowing this cooled air over people makes them feel more comfortable.

Solutions No matter if your job is very large or just large, there s a Reznor high capacity air handler that can meet your need. Reznor furnaces, air handlers and split systems can provide many solutions for your demanding applications. The photos on this page illustrate just some of the places where Reznor equipment has been installed. Why Reznor HVAC Air Handlers? Reznor HVAC equipment is manufactured in a half dozen facilities around the world. You get global support from a company with the most models and options available. With over 125 years of innovation and technological advancements, you can trust Reznor HVAC equipment to help you solve your HVAC challenges. For complete catalog information including submittals, energy calculations, dimension drawings, and more go to ReznorHVAC.com or call 800-695-1901. Specifications & illustrations subject to change without notice or incurring obligations. Nortek Global HVAC, LLC 2018. All rights reserved. Reznor is a registered trademark of Nortek Global HVAC, LLC. Note: In keeping with our policy of continuous product improvement, we reserve the right to alter, at any time, the design, construction, dimensions, weights, etc., of equipment information shown here. 235F-0718 (Replaces MC-LCH-0614 Version A.1)