HIGH performance exchanger

Similar documents
APPLICATION GUIDE FLATAIR FMC - H FIC - H FSC - H. Horizontal packaged air conditioners kw FLATAIR AGU-MSL E. lennoxemeia.

APPLICATION GUIDE DUCTABLE FANCOIL ARIA 2. 1,3-6,6 kw ARIA2-AGU-1610-E.

FLATAIR. E r P APPLICATION GUIDE kw HORIZONTAL PACKAGED AIR CONDITIONER. Cooling capacity : 6-34 kw. Heating capacity : 6-29 kw

Refrigerant Dryers DS Series

KOMFORT EC DB Suspended heat recovery air handling units

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

UNITES TERMINALES ET MINI CTA FIDJI

Adsorption Dryers for Compressed Air

Installation Instructions

CENTRALISED MECHANICAL EXTRACT RESIDENTIAL VENTILATION AND AIR PURIFICATION

Compressed Air Filtration Oil/water separator for compressed air condensate ultrafilter International UFA-AC

Dryer Systems Heatless Regenerating Adsorption Dryers

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

The ultimate in air handling units: directly and indirectly fired

<< >> Condensing technology at the service of oil. Controlling energy to save money

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

InspirAIR Home RESIDENTIAL AIR PURIFICATION

RECOVERY COILS AND ECODIRECTIVE 2018: CONTROL AND DEFROST

Dehumidifiers from Seibu Giken DST

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

G6RC Series TECHNICAL SPECIFICATIONS

Installation Instructions

DD12E DEHUMIDIFIER USER'S MANUAL CONTENTS. VOLTAGE: V~50Hz

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

CHINOOK WARM AIR GAS FURNACE DESIGNED, ENGINEERED AND MANUFACTURED IN CANADA INCLUDING COMPONENTS MADE IN THE USA

CHINOOK THE INDUSTRY S MOST COMPLETE LINE. WARM AIR GAS FURNACE DESIGNED, ENGINEERED, AND MANUFACTURED IN CANADA

INSTALLATION, OPERATING AND MAINTENANCE

SELECTION GUIDE AIR PURIFICATION AND CENTRALISED MECHANICAL EXHAUST VENTILATON

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

TOTAL SYSTEM EFFICIENCY: CONDENSING BOILER SYSTEM MYTH BUSTING. David Grassl PE Mechanical Engineer Principal

QUALITY CONTROL Passive House Checklist

Reciprocating Compressors AIRBOX / AIRBOX CENTER

Ventilation Unit Zehnder ComfoAir 350

INSTALLATION AND SERVICING INSTRUCTIONS TO BE LEFT WITH THE USER

Air-Drying Device. PROTEGO LA and LA/V. Function and Description LA/V. Figure 2 Figure 3

Glasswashers. The Benefi t Makers

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

EMI ENGINEERING SUBMITTAL

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

CONDOR. Supply air ceiling QUICK FACTS

VENTILATION & HEATING CATALOGUE.

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

TOTAL SYSTEM EFFICIENCY: CONTROL STRATEGIES & SYSTEM DISTRIBUTION. David Grassl PE Mechanical Engineer Principal

Dryer Systems. Breathing Air Units

A Waterless Trap from Des Champs Technologies LLC ELIMINATES NEED TO CONSTANTLY MONITOR DRAIN TRAPS FOR DRY OUT AND FREEZING

Z-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Tranquility Digital Quick Start Guide

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

EMI ENGINEERING SUBMITTAL

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

OIL FREE WATER INJECTED SCREW COMPRESSOR WIS 40-75

Operating Instructions

DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXG20LV1BW FTXG25LV1BW FTXG35LV1BW FTXG50LV1BW FTXG20LV1BS FTXG25LV1BS FTXG35LV1BS FTXG50LV1BS

DR AS 5389:2016 Space heating and cooling and ventilation systems Calculation of energy consumption. The physical testing

OPERATING AND MAINTENANCE MANUAL

Dryer Systems Heat Regenerating Adsorption Dryers

G Installation manual Solitude - dmev unit

CHINOOK WARM AIR GAS FURNACE DESIGNED, ENGINEERED AND MANUFACTURED IN CANADA INCLUDING COMPONENTS MADE IN THE USA

Dryer Systems Heat Regenerating Adsorption Dryers

PORTABLE AIR CONDITIONER (LOCAL)

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

MOBILE AIR CONDITIONER. User Manual PC15/20/26-BCB

PLATE HEAT EXCHANGERS ST

General Application Ductless Fume Hoods

Modular air-handling units

COMPACT VENTILATION UNITS DUPLEX R5

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

Stainless Steel Chimney Extractor

DXR 230 PREMIUM. dx system INSTALLATION AND MAINTENANCE INSTRUCTION (ENGLISH VERSION)

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

VarioDry SPN

APPLICATION GUIDE FLEXY FX. Rooftop packaged unit with heat recovery kw FLEXY FX-AGU-1112-E. lennoxemeia.com

DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL R32 MODELS FTXTM30M2V1B FTXTM40M2V1B

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Home Builder Product Selection Guide

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

Entrant: HJC Design Ltd. 192 Shoreham Street Sheffield, UK S1 4SQ Phone: Contact: Matthew Conley

NZ s home ventilation specialists

DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXS20LVMA FTXS25LVMA FTXS35LVMA FTXS46LVMA FTKS20LVMA FTKS25LVMA FTKS35LVMA FTKS46LVMA

OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE FUNCIONAMENTO

Tranquility Digital Quick Start Guide

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

Portable Air-conditioner Use and Care Manual

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

Commercial Gas Water Heaters

COMPRESSORS M100 MOBILAIR. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 6.4 to 10.2 m³/min ( cfm)

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

Glasswashers. The Benefi t Makers

Transcription:

Page 1/9 2014/07 Information and data can not be considered as contractual. Design and data changes may occur without notice during F2A s continuous product development. Dedicated to housing market, the patented air-to-air heat exchanger SB 3.66 is the perfect balance between heat recovery and low pressure loss. It has been designed to combine high energy performances and environmental effi ciency. SB 3.66 s aeraulic and acoustic performances have been tested and approved by independent laboratories, CETIAT & CTTM, according to the European standards. advantages High energy performances Reducing pressure losses by 50% High thermal effi ciency (87% at 120m 3 /h) Good mechanical resistance ( P = 2000 Pa) Optimizing drainage of condensed moisture nomenclature H300 T Range name construction Length x width (366 x 366 mm) Model (height in mm) 41 models: height from 100 to 500 mm (higher heights on request) Airfl ow: from 50 to 600 m 3 /h Exchanger technology Material Operating limits Miscellaneous Plates and caps Sides Assembly Posts, sides & caps Plates Fire classification 0 Voc certified Specific resistance Operating temperature Counterfl ow APET (glycol free) Rigid PVC (phthalates free) High environmental efficiency 0% Volatile Organic Compounds (VOC) Recyclable material Leakage rate < 0,4% Characteristics Hot melt adhesive (glue) with no VOC Welding Low pressure loss 21 pa at 120 m 3 /h C according to EN13501-1 standard Grease, oil, alcohol, salted atmosphere from -30 C to +50 C Handling strap Tongues in option (see p.6), for slide rail mounting 3 / Performances tested by independent laboratories With tongues (optional)

performances Efficiency and pressure loss (EN 308 standard) Test conditions: Supply inlet temperature: 5 C Exhaust inlet temperature: 25 C Exhaust inlet wet bulb temperature: 12,9 C Both of the circuits in underpressure Dry air (relative humidity < 30%) Equal supply and exhaust airfl ow rates model H100 H200 H300 H400 H500 Example: H300 Airflow = 120 m 3 /h Efficiency = 90,6% Pressure loss = 21,4 Pa 90 m 3 /h (25 l/s) η = 81,2% 62,3 Pa η = 85,4% 26,3 Pa η = 88,7% 15,1 Pa η = 91,3% 10,9 Pa 120 m 3 /h (33,3 l/s) η = 77,7% 95,2 Pa η = 82,8% 37,9 Pa η = 86,6% 21,4 Pa η = 89,8% 15,2 Pa η = 92,9% 11,9 Pa airflow m 3 /h (l/s) 220 m 3 /h (61,1 l/s) η = 71,5% 248,5 Pa η = 76,2% 87,4 Pa η = 80,3% 47 Pa η = 84,2% 32,2 Pa η = 87,7% 24,5 Pa 400 m 3 /h (111,1 l/s) η = 70,1% 217,5 Pa η = 74,7% 111 Pa η = 78,4% 72,8 Pa η = 82,4% 53,6 Pa 600 m 3 /h (166,6 l/s) η = 75,9% 132,7 Pa η = 79,23% 95,2 Pa Page 2/9

high performance exchanger sb 3.66 performances Tests carried out at equivalent supply and exhaust airflow rates. Efficiency (EN 308 standard) 100 heat exchanger 95 Page 3/9 Pressure loss in Pa (mm Water Column) Efficiency (%) 90 85 80 75 70 65 60 (51) 500 450 (40,8) 400 350 (30,6) 300 250 (20,4) 200 150 (10,2) 100 50 0 0 100 200 300 400 500 600 (27,7) (55,5) (83,3) (111,1) (138,8) (166,6) Airflow in m 3 /h (l/s) Pressure losses H100 0 100 200 300 400 500 600 (27,7) (55,5) (83,3) (111,1) (138,8) (166,6) Airflow in m 3 /h (l/s) H500 H400 H300 H200 H100 H200 H300 H400 H500

performances Leakage rate Nominal airfl ow = 349 m 3 /h at 50 Pa External leakage Internal leakage Mechanical resistance Pressure Leakage rate Leakage rate compared to nominal airflow -250 Pa 0,2 m 3 /h 0,1% +250 Pa 0,9 m 3 /h 0,3% -100 Pa 0,7 m 3 /h 0,2% +100 Pa 0,7 m 3 /h 0,2% Test carried out with a 500 mm height heat exchanger (SB 3.66 H500) Maximum pressure difference without damaging the heat exchanger = 2000 Pa Maximum operating pressure* = 1000 Pa * Maximum pressure difference between the two fl ows without affecting heat exchanger effi ciency and pressure loss EN308 requirement < 3% Page 4/9

acoustic The SB 3.66 heat exchanger has been tested in an independent laboratory according to ISO 7235 : 2009 standard. Tests under real conditions of use have been carried out on the heat exchanger in order to obtain performances that closely refl ect reality, Acoustic measures have been taken on both circuits independently: fresh air & return air. They show similar results. Page 5/9 Model: SB 3.66 H500 (500 mm height) Attenuations (db) Frequencies (Hz) 125 250 500 1000 2000 4000 8000 Insertion losses 17 12 11 8 7 13 4 Regenerations (db) Frequencies (Hz) Airflow 125 250 500 1000 2000 4000 8000 221 m 3 /h 28 16 14 16 18 23 30 398 m 3 /h 36 27 20 17 18 24 30 608 m 3 /h 43 35 31 26 21 24 30 Note: acoustic performances have been tested according to hereunder conditions

DImensIons Model Actual height (mm) Weight (Kg) 100 101,2 1,8 110 113 1,9 120 124,8 2,0 130 2,1 136,6 140 2,1 Page 5/8 Actual height from 100 to 501 +2 mm Width 366 +1 mm Tongue Side length 194 +1 mm Length without tongue 366 +1 mm 150 148,4 2,2 160 160,2 2,2 170 172 2,3 180 183,8 2,4 190 2,5 195,6 200 2,5 210 207,4 2,6 220 219,2 2,7 230 231 2,8 240 242,8 2,9 250 254,6 2,9 260 3,0 266,4 270 3,0 280 278,2 3,1 290 290 3,2 300 301,8 3,3 310 313,6 3,4 320 325,4 3,5 330 3,6 337,2 340 3,6 350 349 3,7 360 360,8 3,7 370 372,6 3,8 380 384,4 3,9 390 4,0 396,2 400 4,0 410 408 4,1 420 419,8 4,2 430 431,6 4,3 440 443,4 4,3 450 455,2 4,4 460 4,5 467 470 4,5 480 478,8 4,6 490 490,6 4,7 500 502,4 4,8 Overall length with tongues 386 mm Page 6/9

recommendations for InsTaLLaTIon Flow directions to be respected Page 7/9 Top Drainage of condensed moisture Flow directions indicated by arrows on top and bottom of the heat exchanger For horizontal or on-side mounting orientation, an angle of 1,72 (3%) minimum is required to ensure effi cient evacuation of condensed moisture as shown below: For horizontal orientation, F2A marking must be pointed upward. angle > 1,72 A standard mounting orientation (vertical) does not require any angle. We recommend to use 2 different syphons (winter and summer) at the outlet of the condensate drain pan. The syphons height needs to be at least twice higher than maximum pressure difference in the ventilation system. Reminder: 1 mm Water Column = 10 Pa 2 syphons: Winter Summer Bottom Example: Air Handling Unit s differential pressure = 200 Pa 200 Pa = 20 mm WC H1 = 20 mm x 2 = 40 mm H2 = 20 mm x 2 = 40 mm Syphons height must be 80 mm minimum. angle > 1,72

recommendations for InsTaLLaTIon: fan positions Exhaust air Fresh air Exhaust air Fresh air Exhaust air Fresh air Configuration n 1 Outdoor Configuration n 2 Configuration n 3 Outdoor Outdoor Indoor Indoor Indoor Fans positions Indoor acoustic Thermal performances (Winter) Supply air Supply air Return air Supply air Return air Supply air Return air Exhaust air recommended by f2a Optimum fl ow distribution leading to a better effi ciency Low pressure difference between plates reducing internal leakage Heat recovery from motor on supply-air side possible configuration Better acoustic attenuations than confi guration n 1 Reducing freezing risk but affecting the heat exchanger effi ciency High pressure difference between plates affecting internal leakage possible configuration High heat recovery from motors (in winter) Heat gain on exhaust-air side Supply-air side Exhaust-air side Efficiency Heat recovery from motor Configuration n 1 Inlet Outlet 0 + ++ + Configuration n 2 Outlet Outlet + + 0 + Configuration n 3 Inlet Inlet 0 0 + ++ Page 8/9

Page 9/9 LImITs of Use: freezing risk The exhaust air contains moisture which condenses in contact with cold exchanger plates (fresh-air side) and turns into water. This condensed moisture may freeze if exhaust air is below 0. A mechanism into the ventilation system is needed to avoid freezing, such as: Reducing intake airfl ow rate Bypassing the heat exchanger with or without post-heating mechanism Preheating by earth tubes or geothermal heating storage, Use and cleaning InsTrUcTIons Indoor storage, no sunlight Storage temperature: from -30 C to +50 C Operating temperature: from -30 C to +50 C Pressure difference between the two fl ows must not exceed 2000 Pa Use fi lters for exhaust and fresh air to keep the exchanger interior clean Do not cut the handling strap 1 Take the heat exchanger out by pulling the strap. Pay attention to its orientation into the ventilation system Download the SB 3.66 s 2D (DWG, DXF, PDF) & 3D (IGS, STEP) drawings by scanning this code 2 Remove the dust with a household vacuum cleaner freezing zone 3 Put the heat exchanger back in place by pushing it carefully