Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

Similar documents
Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

I. It shall be the responsibility of the department officers to implement this operating guideline.

Enactment Date: Rapid Intervention Team and RIT Officer

SUBJECT FIRE OPERATIONS GUIDELINE (F.O.G.) #F510 Issued: 1/2014 Last Revision: 1/2014 Pages: 9 By Order Of: J.S. Thompson, Fire Chief

ATTIC FIRES. Part 3 HEAVY SMOKE SHOWING

Travis County Emergency Services District #1 Standard Operating Guidelines

Rapid Intervention Team

Structural Firefighting Policy

ATTIC FIRES. Part 2 LIGHT SMOKE SHOWING

Essentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)

3330 N Clayton. C - Side Date: 11/18/2017 Time: 21:48 Incident Number: Address: 3330 N Clayton

Centers for Regional Excellence. Downriver Fire Authority. Organization Committee Objective. Operations Committee Report 2007

Field Operations Guide (FOG) Effective Date: December 1, 2003 Last Revision Date: November 1, 2015

Township Of Jackson, Fire District 3, Station 55 Standard Operating Guidelines FIRE GROUND STRATEGY

INTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

FIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES

SPEARFISH FIRE DEPARTMENT POLICIES AND PROCEDURES

ADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

House Fire IAP. Staffing Assumptions

San Joaquin County Office of Education Career & Technical Education Fire Fighter Technology CBEDS#: 5833

Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.

BROWNSVILLE VOLUNTEER FIRE DEPARTMENT

Rescues individuals in danger from fire, vehicle accidents, industrial accidents and other situation requiring extraction.

DCN: ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS

Additional Materials: Instructor s PowerPoint, Question Files

Required Materials For complete material(s) information, refer to

Westbury Fire Department: Hose Company 2 Drill 7/24/14 Thinking Beyond the Obvious or the Norm

Pro Board Assessment Methodology Matrices for NFPA 1001

Massachusetts FD Fire Fighter Task Survey Analysis Fire Fighter Essential Tasks: COMMONWEALTH OF MASSACHUSETTS FIRE FIGHTER TASK LIST

TITLE: Offensive and Defensive Operations

Carbon Monoxide Poisoning

RAMBLER PARK FIRE SAFETY INFORMATION

SOUTHERN AFRICAN EMERGENCY SERVICES INSTITUTE NPC Registration No. 2014/162285/08. Interior Industrial Fire Brigade Member- NFPA 1081, 2007

AMADOR FIRE PROTECTION DISTRICT

Skill Sheet 17-I-1. Suppress an interior structure fire Direct, indirect, or combination attack. (NFPA 1001, , )

COUNTY OF BERGEN DEPARTMENT OF PUBLIC SAFETY LAW AND PUBLIC SAFETY INSTITUTE POLICE, FIRE & EMS ACADEMIES 281 Campgaw Road Mahwah, N.J.

Truro Police Department. Fire Emergencies. Policy Number: OPS-9.02 Effective Date: June 1, 2000 REFERENCE:

VOLUNTEER FIRE FIGHTER Certification Training Record

TACTICAL GUIDELINES. To provide guidelines to aid the decision making process for personnel during emergency/nonemergency

To provide guidelines to aid the decision making process for personnel during emergency/non-emergency incidents.

Contra Costa County Fire District Station # 69. Battalion 7. November Your station responded to 129 Emergency Calls. Response breakdown

SOUTHERN AFRICAN EMERGENCY SERVICES INSTITUTE NPC Registration No. 2014/162285/08. Fire Fighter 1 - NFPA 1001, 2008

Standardized Curriculum Form Ontario, Canada

San Ramon Valley Fire Protection District GREEN SHEET

OAK GROVE SCHOOL DISTRICT SCHOOL SITE FIRE PREVENTION PLAN

FIRE PROTECTION BUREAU ACCREDITATION AND CERTIFICATION PO Box Olympia WA (360) FAX: (360) AIRPORT FIREFIGHTER

MASTER COURSE OUTLINE

Based on NFPA 1003: Standard for Airport Fire Fighter Professional Qualifications 2015 Edition

VOLUSIA COUNTY FIRE CHIEFS ASSOCIATION MODEL OPERATING GUIDELINE

Outline. Standards of Coverage. ICS Features 2/12/2016 ICS

Mission. Vision. To set the standard for excellence and innovation in public safety. Department Description

2012 SunTrust Center ERT Annual Review. 919 East Main St. Richmond, VA

EASTERN ARIZONA COLLEGE Fire Department Operations II

NFPA Fire Fighter I (Including Entry Level Fire Fighter) Task Book

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 High Rise On Scene Revised

Emergency Planning and Preparedness

DEPARTMENTAL GUIDELINES CHAPTER 6 TACTICAL OPERATIONS

IMPORTANCE of FIREGROUND VENTILATION PRACTICES and DYNAMICS IN FIREFIGHTING (PART I)

Travis County Emergency Services District #1 Standard Operating Guidelines

AMADOR FIRE PROTECTION DISTRICT

INCIPIENT FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

Guemes Island Fire Department

Mulch fires, trash can fires, or other fire outside a building should be reported by the following methods:

University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE FIRE MEDICAL EMERGENCY Anyone discovering excessive heat,

Length of Course: 32 Hours Lecture/Lab Breakdown: 14/18

Death in the line of duty

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

Whitestown Fire Department Standard Operating Procedure

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

Fire Department Orientation / Organization

MATRIX TO DETERMINE YOUR PRESENT POSITION IN MEETING N.F.P.A. 1720

Talking about NFPA History of NFPA NFPA Standard 1710: Organization and Deployment of Fire Suppression Operations, EMS

Elko County Human Resources Employment Opportunity Announcement

Fire Service Considerations A Primer for Building and System Designers. Society of Fire Protection Engineers Fire Service Committee

Death in the line of duty

SMALL TOOL REPLACEMENT PLAN

PATTERNS OF FIREFIGHTER FIREGROUND INJURIES

THESE ARE THE OPERATING PROCEDURES OF THE BRENTWOOD FIRE DEPARTMENT

Lassen Community College Course Outline

I. INTRODUCTION. A. Purpose: To provide procedures and guidelines for personnel responding to and operating at working structure fire incidents.

EASTERN ARIZONA COLLEGE Fire Department Operations I

Technician I Kyle Wilson Line of Duty Death April 16, Marsh Overlook Structure Fire Investigative Report

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 6 Utilities Electrical Emergencies Revised

Emergency Action Plan for

Excerpted from NFPA 1403 Standard on Live Fire Training Evolutions

CENTRAL CALAVERAS FIRE AND RESCUE TRAINING DIVISION CAREER TRAINING AND DEVELOPMENT FIREFIGHTER II STANDARDS

Career Fire Fighter Dies While Exiting Residential Basement Fire - New York

Smoke Management in High-Rise Structures

FEMS Board Executive Committee Agenda 3/2/2015

Public Safety Institute Fire & Rescue Course Fee Catalog

Instructor Guide. Title: Tactical Approach to Chimney Fires. Time Required: 2 hours. Materials: PowerPoint presentation AV equipment

1. DEPARTMENTAL POLICY SYSTEM (January 2014) I. POLICY CHECKLIST (N/A) DEFINITIONS VOLUME II, CHAPTER 1. STATION LOGBOOK

2010 Fire Log Fire Log. Annual Fire Safety Report

NATIONAL FIRE PROTECTION ASSOCIATION Fourth Survey of the Needs of the U. S. Fire Service

Dutchess Community College. Emergency Action Plan. Conklin Hall College Residence

Floor Warden Training. Thursday, May 27, 2015

Promotional Prep Fire Service Promotional Test Preparation 301 Claremont Ave. Suite 5 Montclair, NJ (201) or promotionalprep.

FRS 201. Firefighters Advanced Skills I. 45 clock hours 3 credit bouts

FL Specific Training for DOD Firefighter Equivalency

Transcription:

Standard Operating Guidelines Page: 1 of 6 15.07 Scope: Commercial properties shall include businesses, schools and shops with very limited special hazards. 15.0701 First engine placement: Positioning of the engine is the responsibility of the driver. The engine shall be positioned keeping the following factors in mind: Location of fire in building; Access to building; Keep the front of building open for the truck company. Generally on small to medium size commercial properties, the engine shall position just past the building, leaving the front of the building open for the truck company. Sprinklered property: Positions at Fire Department Connection and Driver/Operator anticipates connection of the standpipe/sprinkler system; however the engine does not connect until a Working Fire is confirmed. 15.0702 First engine to arrive (water supply): On smoke showing, visible fire or confirmed working fire, the first arriving engine shall forward lay a Large Diameter Hose (LDH) 5 inch supply line from the nearest fire hydrant prior to arriving at the fire building, OR position the first arriving engine company at the nearest fire hydrant prior to the fire building and allow the officer and fire team to investigate the condition of the reported fire building (hydrant person & driver/operator should stay with the engine) Positioning at the nearest fire hydrant shall only be done if the distance is 300 feet or less from the fire building. 15.0703 Catching the hydrant: The first arriving engine company should stop at the nearest fire hydrant prior to the reported building on fire. The Lead-Off firefighter with a portable radio shall remove the LDH, hydrant accessory bag and wrap the hydrant. Once the Lead-Off firefighter has secured the hose around the hydrant he/she shall signal the driver of the first arriving engine to proceed to the fire. The Lead-Off firefighter shall wait until the Driver signals to charge the LDH. After the line is charged, the Lead-Off person will proceed to the fire counting the sections of hose and checking the hose connections. 15.0703 Fire Brigade or Emergency Response Team: If the facility has a known Emergency Response Team, the first-in apparatus or officer shall meet a team representative at the pre-determined location and obtain a size-up of the situation.

Standard Operating Guidelines Page: 2 of 6 15.0704 Rescue: Life safety is the #1 priority. A primary search should be conducted immediately it is also imperative that a hose line be stretched to the seat of the fire by the first arriving engine in an attempt to stop the forward progress of the fire. This will facilitate the rescue effort and lessen the danger to the occupants. If the occupants are visible from the exterior of the building, an attempt should be made to rescue them with the use of ground ladders. Victims should be removed via the interior stairway if at all possible. Ladders should be used only if passage down the stairway is not possible. If staffing permits, the rescue should be carried out while a hose line is being advanced to the seat of the fire. Members advancing the hose line to the fire area can search that area as well as extinguishing or controlling the fire. Any emergency medical care should be provided to the occupants of the residence as soon as possible, such as cardiopulmonary resuscitation. Any working fire requires the presence of an EMS on location. 15.0705 Fire control: In order to establish a safe and an efficient fire ground operation, the Incident Commander shall appoint an Operation Section Chief. At least two (2) hose line shall be advanced to the seat of the fire. The line chosen shall never be less than 1-3/4 inches in diameter. In most cases the fire attack should be made from the unburned side of the building. In many cases, the line can be advanced through the front door of the building. From this point, access is usually available to all areas of the building. The number of lines to be used will be the choice of the Operation Section Chief and depend directly on the nature and size of the fire encountered. A Rapid Intervention Team is necessary to potentially rescue the fire attack team. 15.0706 Second arriving engine: Sprinklered properties: The second engine shall report to the first arriving engine at the Fire Department Connection and position itself to reverse lay LDH from the first engine to the water source. Non-sprinklered properties: The second arriving engine shall locate an alternative water source and stand-by for further instructions from the Incident Commander. The crew from the second arriving engine may be utilized for rescue, additional hand-line placement, fire suppression, truck operations or as the Operations section chief instructs them for the control or mitigation of the incident. 15.0707 Truck company positioning: The Truck Company will most often position in the front of the building. Positioning will normally be the responsibility of the truck company officer, if not assigned by the Operations section chief. Positioning of the Truck Company will also be based on the size of the building, location of the fire, access, etc. It may also be advantageous to position on a corner of the building in order to sweep two sides. On commercial properties, positioning shall be made with the following objectives in mind: A. Use of ladder for rescue B. Use of ladder to roof C. Building collapse D. Master stream operations

Standard Operating Guidelines Page: 3 of 6 15.0708 Truck company operations: After arriving on location, the truck company officer shall report to the Operation Section Chief for further instructions. It will be the responsibility of the Truck OIC, to prioritize the support activities to be performed according to the fire conditions presented. Although earlier arriving engine companies may have already implemented some of the duties, it will be the responsibility of the Truck OIC to coordinate the remaining activities to ensure they will be completed. The following are some of the activities or duties that must be addressed: rescue, ladders, forcible entry, salvage, ventilation, and utility control. Many of these duties can be carried out simultaneously with one another. DEFENSIVE WATER APPLICATION: Aerial apparatus water supply shall be provided by the second or third arriving engine using large diameter hose (LDH). Allow positioning to accommodate water supply set-up. 15.0709 Rescue company operations: After arriving on location, the rescue company officer shall report to the Operation Section Chief for further instructions it will be the responsibility of the Rescue OIC, to prioritize the support activities to be performed according to the fire conditions presented. Although earlier arriving engine companies and/or truck companies may have already implemented some of the duties, it will be the responsibility of the Rescue OIC to coordinate the remaining activities to ensure they will be completed. The following are some of the activities or duties that must be addressed: rescue, ladders, forcible entry, salvage, ventilation, RIT and utility control. Many of these duties can be carried out simultaneously with one another. 15.0710 Primary search: A primary search shall be performed at every fire situation, whether fire is showing or not. The only difference is the number of firefighters assigned this task by the operation section chief. In nothing showing situations, the primary search can be assigned to two firefighters, however, if a fire is located, more firefighters must be assigned to the task. The team performing search and rescue must be equipped with a portable radio to keep in constant communication. When conditions indicate there is a fire or the first arriving company reports a fire in their size-up, a primary search must be performed to locate and remove endangered occupants, or to verify that civilians have escaped the fire. The fire attack team can perform the primary search of the immediate fire area while the truck or rescue company personnel begin the primary search on the floor immediately above the fire. All searches must be made using a search pattern indicated in Section 15.0510. If time and staffing permits, the search and rescue teams operating above the fire should do so with the protection of a hand line. This will provide protection for the firefighters performing this task. Tagline/rescue rope should be used as a minimum protection device to lead search personnel to the way out of the building. This will provide protection for the firefighters performing this task. Firefighters performing the primary search must have forcible entry tools with them to force open locked doors or to aid the escape of the firefighter should he/she become trapped in a building or room. Victims are often overcome attempting to escape the fire. For this reason, firefighters performing the primary search will commonly find the victims next to doors and windows. Firefighters should pay close attention for signs of trapped or injured occupants. Coughing, moaning, or cries for help indicate people may have not escaped the fire. If occupants of victims are located, this should be communicated to the operation sections chief immediately. Victims should be removed via the interior stairway, if at all possible, or the closest exit point. Ladders should be used only if passage down the stairway is not possible.

Standard Operating Guidelines Page: 4 of 6 15.0711Ventilation: Ventilation should be one of the early priorities! Ventilation must be performed. Ventilation facilitates rescue, fire control and property conservation. Ventilation shall not occur until attack lines have been charged. If the location of the fire cannot be determined, the safety of the interior teams or victims may be compromised. The Operation Section Chief will determine the need for vertical or horizontal ventilation. This task will normally be conducted by the truck company but could be conducted by the second arriving engine team if necessary. Fire that extends to attics must be controlled quickly. Ventilation of the roof is essential. Venting of the roof should be performed directly over, or as close as SAFELY possible to the fire. In fires that are extremely smoky, roof ventilation should be performed over stairwells or hallways to clear these areas of smoke and toxic gases. When roof ventilation is performed, it shall be performed with a minimum number of two firefighters in full protective equipment, including SCBA. The following equipment shall be considered standard equipment to be taken to the roof at all times: A. Sledge Hammer B. Pike Poles (10 and/or 12 ) C. Power saws D. Rope E. Flashlights F. Roof Ladders(s) G. Radio H. Charged hose line for fire fighter protection only. Prior to roof ventilation activities, at least two ladders must be raised to the roof. Depending on access, the truck can be positioned to the roof and a ground ladder placed as a secondary means of egress. One large opening should be made rather than two smaller ones. Care shall be taken not to cut or damage the supporting roof support systems. If the roof shows conditions of collapse, (sagging, separation of roof and walls, large cracks or openings around ducts, chimneys, etc.), vent from the aerial device. Operation Section Chief must be notified at once. Once the opening(s) have been made, be sure to remove any ceilings to ensure ventilation is accomplished in the attic or upper most floors. Once ventilation is complete, retreat from the roof and report to Operation Section Chief that ventilation is complete. 15.0712 Rapid Intervention Team: When interior fire attack occurs within a structure, the Incident Commander shall assign a RIT team to the Operation Section Chief. The RIT team shall secure the necessary equipment needed to perform an effective and efficient removal of personnel should they experience trouble. It will be the responsibility of the RIT team leader to stay appraised with the probable location of all personnel who are operating within the structure. It will be critical to coordinate rapid intervention team activities with the Operation Section Chief along with the scene Safety Officer and the Accountability Director. For large operations as is the case with Industrial Properties, the Incident Commander or RIT team leader may request additional units to assist with Rapid Intervention Team assignments. The need for additional RIT personnel may be due to the size of the property or lack of sufficient manpower by the RIT team. In the event that more than one RIT team is operating on the scene, all personnel shall operate under the RIT team leader.

Standard Operating Guidelines Page: 5 of 6 15.0713 Secondary search: A secondary search must be started on the fire building as soon as or shortly after the primary search is completed. All areas should be checked thoroughly for anyone who may have survived the fire or for any victims who may have been missed during the primary search. The Truck OIC shall inform the Operation Section Chief that the secondary search has been complete. 15.0714 Forcible entry: Look for a KNOX BOX! The truck and/or rescue companies should be prepared to force open doors, locked gates, windows, removal of bars, etc. to provide for access to the building. Truck/Rescue company personnel shall carry with them forcible entry equipment such as axes, pike poles, pry bars, halligan bars, saws, etc. Entry shall be made in the quickest and most cost-effective manner. 15.0715 Utility control: The appropriate utility companies shall be notified. Truck company firefighter can secure the gas and electrical utilities. 15.0716 Property conservation: Property conservation measures should begin as soon as possible to reduce the property loss by fire, heat, and smoke. Property conservation efforts are to be performed by personnel when staffing levels and conditions permit salvage operations to begin. Salvage covers should be used to protect valuables and to prevent further damage by water and smoke. 15.0717 Overhaul: When the fire has been confined and/or declared under control, overhaul efforts should begin. At least one hose line shall remain in service during overhaul. Overhaul will be continued at the discretion of the Operation Section Chief. Truck company personnel will assist engine company personnel with the task of overhaul. Truck company personnel must pull walls and ceilings that have been exposed to fire to search for hidden fire prevent a rekindle. Use of a thermal imaging camera is essential during overhaul to spot hidden fire without having to open all the walls and ceilings within the structure. Consider starting the investigation before overhaul. This may limit the destruction of evidence during overhaul. 15.0718 Safety: The safety of fire department personnel is of the utmost concern. No member shall be permitted to take part in fire suppression activities unless that person is wearing full protective clothing including Self- Contained Breathing Apparatus (SCBA). SCBA(s) shall be worn at all times on the interior of the building during fire suppression activities--including during overhaul. SCBA(s) shall be worn until it can be determined that the level of carbon monoxide in the structure is at a safe level. At that time the Operation Section Chief can grant permission to the operating teams to remove their SCBA(s). All injuries to fire fighters requiring medical attention shall be reported immediately to Incident Commander.

Standard Operating Guidelines Page: 6 of 6 15.0719 Team Units: Teams are to stay together. If their Officer is assigned another detail, a team leader will be designated before the Officer is reassigned. It is imperative that units operate as teams at commercial property incidents. 15.0720 Greater Alarms: Depending on life hazards and the fire situation present, at a minimum an additional Engine and Truck company shall seriously be considered for staging.