Economic Analysis Based on Energy and Water Consumptions between Air-Cooling and Water-Cooling

Similar documents
Optimization of Cooler Networks Considering Different Types of Cooling

Shortcut Model for Predicting Refrigeration Cycle Performance

A New Graphical Approach for Heat Exchanger Network Retrofit Considering Capital and Utility Costs

Identification of the Most Effective Heat Exchanger for Waste Heat Recovery

Modelling of divided wall column

Evaluation of Sorbents at Elevated Temperatures for Downhole Application

A Novel Freeze Drying Process by Using Self-Heat Recuperation Technology

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Modelling of End-use Electricity Consumption and Saving Potential in Household Sector in Northern Thailand

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Best Row Number Ratio Study of Surface Air Coolers for Segmented Handling Air-conditioning System

Minimising Energy Use in Milk Powder Production using Process Integration Techniques

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Performance analysis of a liquid desiccant evaporative cooling airconditioning system powered by solar energy

CFD Analysis of Fire Characteristics on Subway Junction Station

Brown Hills College of Engineering & Technology

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

The Energy Consumption Investigation of the Hotel Central. Air-conditioning System and the Research of Energy Saving Measures

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

State Grid Zhejiang Electric Power Corporation Electric Power Research Institute, Hangzhou, , China

Limiting Distances for Flame Merging of Multiple n-heptane and Di-tert-Butyl Peroxide Pool Fires

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger


A Method for Fire Detecting by Volume and Surface Area Concentration Based on Dual Wavelengths

The Effect of Quantity of Salt on the Drying Characteristics of Fresh Noodles

Influences of temperature of vapour-condenser and pressure in the vacuum chamber on the cooling rate during vacuum cooling

Design and Development of Water Cooled Condenser for Domestic Refrigerator

ScienceDirect. Development progress of critical equipment in the CSNS cryogenic hydrogen system

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Study on the North China Rural Water Supply Project O&M Cost Standard Rating

Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel

A TRNSYS Simulation Case Study on Utilization of Heat Pump For both Heating and Cooling

Compendium DES July 2016, CARN

Evaluation and Development of Air-conditioners using Low GWP Refrigerant

Experimental Research of Air Source Heat Pump Frosting and Defrosting in a. Double Stage-Coupling Heat Pump

New Design for Energy Saving Water Dispensers

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

European Researcher, 2014, Vol.(75), 5-2

Numerical Analysis of Heat Transfer in Radiant Section of Fired Heater with Realistic Imperfect Geometry of Tube Coil

COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal

Efficient adsorption refrigerators integrated with heat pipes

Global Journal of Engineering Science and Research Management

Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products

Development of Small-diameter Tube Heat Exchanger: Circuit Design and Performance Simulation

Development of Bionic Air Cooler Used in High Temperature Coal Mine

Structure Improvement and Flow Field Analysis of Condenser in Freeze drying Equipment

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

A study of Transient Performance of A Cascade Heat Pump System

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

A New Dedicated Outdoor Air System with Exhaust Air heat recovery

Enhancement of COP in Vapour Compression Refrigeration System

Influence of Feed Water Heaters on the Performance of Coal Fired Power Plants

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER

Research on the Monitor and Control System of Granary Temperature and Humidity Based on ARM

Cooperation of a Steam Condenser with a Low-pressure Part of a Steam Turbine in Off-design Conditions

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Recent Advances in Energy, Environment and Economic Development

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates

Heat transfer and heating rate of food stuffs in commercial shop ovens

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Innovative Hybrid Heat Pump for Dryer Process Integration

Experimental Study on the Effects of Compression Parameters on Molding Quality of Dried Fish Floss

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

Available online Journal of Scientific and Engineering Research, 2018, 5(11): Research Article

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Modeling and Simulation on Temperature Control System of Farm Products Baking Equipment. Liu Jun, Jia Zhenwei, Guo Rongxing

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Design of Multi-Sensors Cooperation Control System for Intelligent Building

Temperature and humidity controller system based on single chip microcomputer

Application of the VRV Air-Conditioning System Heat Recovery Series in. Interior Zone and Analysis of its Energy Saving

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Lin Mo, Dihua Li Graduate school of Landscape Architecture, Peking University

STUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER

Study on an environmental simulation system of low/high temperature. for great space

Key Words: Microalgae; Solar Dryer; Exergy Analysis; Energy Analysis;

Experimental Study of Initial Process of Frost on Heat Exchanger Surface of Refrigerated Transport Vehicle

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

Capillary Tube and Thermostatic Expansion Valve Comparative Analysis in Water Chiller Air Conditioning

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Direct and indirect evaporative cooling

PERFORMANCE IMPROVEMENT OF SPLIT AIR CONDITIONER USING EVAPORATIVE COOLING METHOD IN THE CLIMATIC CONDITION OF GUWAHATI, ASSAM

EFFICIENT ADSORPTION REFRIGERATORS INTEGRATED WITH HEAT PIPES

Tube-in-tube heat exchanger Type HE

Transcription:

367 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 61, 2017 Guest Editors: Petar S Varbanov, Rongxin Su, Hon Loong Lam, Xia Liu, Jiří J Klemeš Copyright 2017, AIDIC Servizi S.r.l. ISBN 978-88-95608-51-8; ISSN 2283-9216 The Italian Association of Chemical Engineering Online at www.aidic.it/cet DOI: 10.3303/CET1761059 Economic Analysis Based on Energy and Water Consumptions between Air-Cooling and Water-Cooling Haitian Zhang a, Xiao Feng a*, Yufei Wang b a School of Chemical Engineering & Technology, Xi'an Jiaotong University, Xi'an, Shaanxi, P.R. China b School of Chemical Engineering, China University of Petroleum, Beijing, P.R. China xfeng@mail.xjtu.edu.cn Cooling process is one of the most common processes in industries. There are two basic types of cooling systems, including air-cooling and water-cooling systems. Whichever is adopted, obviously energy and water consumptions should be needed. With the rapid development of social economy in China, energy-saving and emission-reduction, as well as process water conservation, become focus issues. Considering performance and economy of energy and water has reference value for reasonable choice of cooling type. In this paper, the cooling range from 95 o C to 35 o C is considered. For dry air cooler, spray type air cooler, evaporative air cooler, and open style circulating water cooling systems, energy and water consumptions are calculated and compared under different dry bulb temperature and relative humidity conditions. Besides, under different price radio of fresh water and industrial electricity, economic analysis is performed to determine the reasonable cooling type. 1. Introduction Heat transfer is one of the most common processes in industries. The first consideration of the whole heat exchanger network should be heat recovery, and its remaining heat will be cooled by coolers. Cooler can be classified into two categories: air cooling and water cooling. Comparison between air cooling and water cooling is one of key issues of related researches. Shapiro et al. (1982) evaluated water-cooled and air-cooled devices, but limited to the condition of high dry bulb temperature and high relative humidity. Alhazmy et al. (2006) discussed evaporate cooling systems and direct mechanical cooling, without concern for other cooling methods. Bolotin et al. (2015) made a comparative study of typical evaporative air cooler and regenerative evaporative air cooler. Recently, energy-saving and industrial water conservation have been the focus of research. In this paper, for dry air cooler, spray type air cooler, evaporative air cooler, and circulating cooling water systems, energy and water consumptions are calculated and compared under different dry bulb temperature and relative humidity conditions. Moreover, economic analysis is performed to select the reasonable cooling type in different price radio of fresh water and industrial electricity. This work is valuable for reasonable choice of cooling method. 2. Energy and Water Consumption of Air Cooler 2.1 Energy and Water Consumption of Dry Air Cooler The calculation of a dry air cooler is based on ASPEN EDR. Select the module of air cooler, and then enter flows, physical property data, and chilling temperature. Choose air under different relative humidity as cooling medium, leading to data through simulation, such as static pressure drop, air outlet temperature. The energy consumption of dry air cooler is mainly fan power, which can be computed as follows. 2 ρ b V 2.778 10 Δp + V 0.98604+ 0.01435 10 H + 2.495 10 H 2 2 900πD f N= η η η -7-2 -9 2 L st L 1 2 3 (1) where N is motor power, kw; Δpst is total static pressure drop, Pa; ρb is air density, kg m -3 ;V is actual wind flowrate, m 3 h; Df is fan impeller diameter, m; η1 is fan efficiency, whose value is taken as 0.75 in this paper; Please cite this article as: Zhang H., Feng X., Wang Y., 2017, Economic analysis based on energy and water consumptions between aircooling and water-cooling, Chemical Engineering Transactions, 61, 367-372 DOI:10.3303/CET1761059

368 η2 is transmission efficiency, whose value is taken as 0.92 in this paper; η3 is motor efficiency, whose value is taken as 0.9 in this paper; HL, altitude, m. Dry air cooler has no water consumption. 2.2 Energy and Water Consumption of Wet Style Air Cooler For wet style air coolers, heat transfer is enhanced in some ways, including humidifying and spraying. According to jetting modes, it comes in several varieties: spray type air cooler, evaporative air cooler, etc. This paper chooses spray type and evaporative air cooler to calculate and analyse. Energy consumption of a wet style air cooler comes mainly from the fan and spray water pump. In this paper, for a spray type air cooler, the head of delivery of its spray water pump is taken as 20 m, while its pump efficiency is taken as 48.5 %; for an evaporative air cooler, the head of delivery of its spray water pump is taken as 25 m, while its pump efficiency is taken as 45.5 %. When air flowrate is about 100,000 kg/h, the film heat transfer coefficient of the shell side can be calculated. h = 90.7φ G B θ (2) 0.05+0.08N P 0.77-0.35N P -0.35 o θ F S where ho is film heat transfer coefficient of the shell side, W m -2 oc -1 ; GF is air mass flowrate on the windward side, kg m -2 s -1 ; φθ is fin height influence coefficient, whose value is 1; BS is spraying intensity, kg m -2 h -1 ; θ is temperature coefficient. For a spray type air cooler, the calculation can be carried out in subsequent process after the inlet air is humidified. The outlet air temperature can be formulated as Eq(3). 3600Q t g2 = t g1 + 2.55 + 0.15NP φθbs θ WC a pa -0.54 0.35 (3) where tg1 and tg2 are inlet and outlet air temperature of wet style air cooler respectively, o C; Wa is air flowrate of the wet style air cooler, kg s -1 ; Cpa is specific heat of air, kj kg -1 oc -1. The calculating formulas of fan power is the same as Eq(1), while motor power of the spray water pump is calculated as follows. 1.25WAgH P N = 3600η (4) where PN is motor power of the spray water pump, kw; WA is water flowrate, m 3 h -1 ; g is acceleration of gravity, m s -2 ; H is head of delivery, m; η is pump efficiency. Ignoring heat loss, for an evaporative air cooler, heat transferred of the hot fluid is the sum of heat absorbed by air and spray water, while its inlet air is equivalent to the ambient air. Other computational processes can refer the spray type air cooler. For a wet style air cooler, the water consumption is the sum of evaporated water and blowdown, which accounts for 30 % of the evaporated water. The evaporated water is showed as Eq(5). e A 2 1 W =W X - X (5) where We is water evaporation quantity, kg h -1 ; X1 and X2 are absolute humidity of inlet and outlet air, respectively, kg (steam) kg (dry air) -1. 3. Energy and Water Consumption of Open Type Circulating Water Cooling System A circulating cooling water system can be divided into two classes: open type circulating water cooling system and full-closed circulating cooling water system. Open type is chosen to analyse because of wide using. 3.1 Energy Consumption of Open Type Circulating Water Cooling System Circulating water pump is the basis cause of energy consumption, which can be calculated with Eq(3). In this paper, its head of delivery is taken as 15 m, while its pump efficiency is taken as 72.9 %. 3.2 Water Consumption of Open Type Circulating Water Cooling System Water consumption of an open type circulating water cooling system mainly consists of evaporation loss, windage loss and blowdown loss, which can be formulated as follows. N W -9 2-8 -5 m = -2.7778 10 Tw - 3.5714 10 T w + 2.0635 10 T w + 0.001 ΔtWr N -1 (6) where Δt is temperature difference of cooling water between inlet and outlet, o C; Wr is circulating water volume, m 3 h -1 ; N is design cycles of concentration; Wm is water consumption, m 3 h -1 ; Tw is wet bulb temperature, o C.

369 4. Analysis of Energy and Water Consumption During Cooling Process 4.1 Analysis of Energy Consumption During Cooling Process Figure 1 and 2 demonstrate energy consumption of cooling methods under different relative humidity. Figure 1: Relationship between Tw and energy Figure 2: Relationship between Tw and energy consumption when relative humidity is 0.4 consumption when relative humidity is 0.6 As is shown in Figure 1, when the dry bulb temperature is below 12 o C, the open type circulating water cooling system has the lowest energy consumption; when the dry bulb temperature is above 12 o C, the spray type air cooler has the lowest. In this case, the dry air cooler has the highest energy consumption. Figure 2 shows that the energy consumption of spray type air cooler is the lowest one, followed by the open type circulating water cooling system and evaporative air cooler; that of the dry air cooler is also the highest. Since the specific heat of air is much smaller than that of water, dry air cooler needs more air, under the same cooling duty, leading to higher energy consumption caused by fan. Compared with spray type air cooler, evaporative air cooler needs less spray water and more air, while fan power occupies a larger proportion in energy consumption than power of spray water pump, so it requires more energy consumption. The inlet air temperature can be reduced to about its wet bulb temperature by wet style air cooler. Under lower relative humidity, energy consumption of a spray type air cooler is close to that of an open type circulating water cooling system. Under certain relative humidity, the higher the dry bulb temperature is, the smaller the difference in temperature between dry bulb and wet bulb is, so that the cooling capacity of a spray type air cooler is lower, with higher energy consumption, and vice versa. Under higher relative humidity, the difference in temperature between dry bulb and wet bulb is relatively small, so a spray type air cooler has lower cooling capacity than an open type circulating water cooling system, while its energy consumption is higher. 4.2 Analysis of Water Consumption During Cooling Process Under different relative humidity, water consumption of these cooling methods can be seen in Figure 3 and 4. Figure 3: Relationship between Tw and water Figure 4: Relationship between Tw and water consumption when relative humidity is 0.4 consumption when relative humidity is 0.6

370 Figure 3 and 4 show that an open type circulating water cooling system has the highest water consumption; water consumption of a spray type air cooler is higher than that of an evaporative air cooler. This is because open type circulating water cooling system needs much water for cooling due to evaporation loss, windage loss and blowdown loss; a spray type air cooler requires more spray water than an evaporative air cooler, causing higher water consumption. 5. Economic Analysis of Cooling Process To a great extent, economic analysis of cooling processes depends on price of fresh water and industrial electricity. The price in different important industrial cities of China is given in Table 1, obtained from China Statistical Yearbook 2015. The price radio of fresh water and industrial electricity is set as the variable, the scattering plots curves of price radio and annual total cost are drawn, and then the curves are fitted to analyse. ASPEN EDR and the Economics module in ASPEN PLUS are used to determine the cost of those cooling methods. Depreciation for plant assets adopts double-declining-balance method. Table 1: Price of fresh water and industrial electricity in different cities of China and its radio City Price of electricity (CNY/kWh) Price of fresh water (CNY/m 3 ) Price radio (kwh/m 3 ) Nanchang 0.66 2.37 3.60 Wuhan 0.63 2.35 3.70 Harbin 0.59 2.40 4.05 Chengdu 0.60 2.70 4.50 Fuzhou 0.62 3.00 4.82 Yinchuan 0.48 2.60 5.43 Nanjing 0.66 3.60 5.45 Shanghai 0.73 5.00 6.89 Urumqi 0.38 2.70 7.07 Hangzhou 0.45 3.90 8.69 Shijiazhuang 0.59 5.33 9.10 Jinan 0.65 5.95 9.19 Chifeng 0.51 4.90 9.61 Lanzhou 0.25 2.53 9.96 Xi'an 0.57 5.80 10.17 Average 0.56 3.68 6.59 5.1 Economic Analysis of Water Cooling Process in 5 o C The relationship between the price radio and annual total cost at 5 o C is shown in Figure 5 and 6, when the relative humidity has a value of 0.4 and 0.6. Figure 5: Relationship between price radio and annual Figure 6: Relationship between price radio and annual total cost at 5 o C when relative humidity is 0.4 total cost at 5 o C when relative humidity is 0.6

Under lower relative humidity, according to Figure 5, the open type circulating water cooling system has the lowest annual total cost. Under higher relative humidity, from Figure 6, when the price radio is lower than 6.5, the annual total cost of the open type circulating water cooling system is also the lowest; when the price radio is higher than 6.5, that of the evaporative air cooler is the lowest, because its energy consumption is lower than that of the dry air cooler, while its water consumption is lower than that of the evaporative air cooler. 5.2 Economic Analysis of Water Cooling Process in 15 o C Figure 7 and 8 represent the relationship between the price radio and annual total cost at 15 o C, under the condition that the value of relative humidity is 0.4 and 0.6. 371 Figure 7: Relationship between price radio and annual Figure 8: Relationship between price radio and annual total cost at 15 o C when relative humidity is 0.4 total cost at 15 o C when relative humidity is 0.6 As is shown in Figure 7, under the condition that the value of relative humidity is 0.4, when the price radio is lower than 10.4, the annual total cost of the open type circulating water cooling system is the lowest; when the price radio is higher than 10.4, that of evaporative air cooler is the lowest. From Figure 8, under the condition that the value of relative humidity is 0.6, when the price radio is lower than 6.2, the open type circulating water cooling system has the lowest annual total cost; when price radio is higher than 6.2, the evaporative air cooler is the best choice. There is no doubt that in terms of economic performance, water cooling is more advantageous. Additionally, since, to some extent, the evaporative air cooler has advantages of water cooling and air cooling, it has the lowest annual total cost when relative humidity is comparatively higher. 5.3 Economic Analysis of Water Cooling Process in 25 o C When the value of relative humidity is 0.4 and 0.6, Figure 9 and 10 demonstrate the relationship between the price radio and annual total cost at 25 o C. Figure 9: Relationship between price radio and annual Figure 10: Relationship between price radio and total cost at 25 o C when relative humidity is 0.4 annual total cost at 25 o C when relative humidity is 0.6

372 According to Figure 9, under lower relative humidity, when the price radio is lower than 10, the open type circulating water cooling system has the lowest annual total cost; when the price radio is higher than 10, so does dry air cooler. As is shown in Figure 10, under higher relative humidity, when the price radio is lower than 6.5, the annual total cost of the open type circulating water cooling system is the lowest; when price radio is between 6.5 and 10.2, that of the evaporative air cooler is the lowest; when price radio is higher than 10.2, the dry air cooler is the best choice. Water cooling is favourable with a lower price radio, and a higher price radio leads to lower annual total cost of air cooler. Besides, the evaporative air cooler combines advantages of both water cooling and air cooling, which is dominant when price radio is in the middle. 6. Conclusions In this paper, dry air cooler, spray type air cooler, evaporative air cooler and open style circulating water cooling system are calculated and compared. Among these cooling methods, a dry air cooler has the highest energy consumption. Energy consumption of an open type circulating water cooling system is the lowest under the condition of lower dry bulb temperature and relative humidity. When the dry bulb temperature is higher and relative humidity is lower, or when the relative humidity is higher, a spray type air cooler has the lowest energy consumption. A dry air cooler has no water consumption, while an open type circulating water cooling system has the highest water consumption. Furthermore, water consumption of an evaporative air cooler is lower than that of a spray type air cooler. The price radio of fresh water and industrial electricity exerts tremendous influence on economy of cooling methods. The dry air cooler is the best choice where the price radio is higher, while the open type circulating water cooling system should be chosen where the price radio is lower. Additionally, where the price radio is in the middle, the evaporative air cooler has the lowest annual total cost under the condition of higher dry bulb temperature. Restricted to the cooling medium, the dry air cooler might not cool hot fluid into lower temperature, which can be solved in the way of following by water cooling. Acknowledgments Financial supports provided by the National Natural Science Foundation of China (21476256) are gratefully acknowledged. References Alhazmy M.M., Jassim R.K., Zaki G.M., 2006, Performance Enhancement of Gas Turbines by Inlet Air-Cooling in Hot and Humid Climates, International Journal of Energy Research, 30, 777-797. Bolotin S., Vager B., Vasilijev V., 2015, Comparative Analysis of the Cross-Flow Indirect Evaporative Air Coolers, International Journal of Heat & Mass Transfer, 88, 224-235. Cheng Q., 2011, The Temperature Measurements of Evaporation Air Cooler in Rain Zone and Program Develop. ME Dissertation, HUST, Wuhan, China. Lai Z.P., Zhang R.K. (Ed.), 2009, Air Cooled Heat Exchanger, Beijing, China, 509 p, ISBN: 978-7-80229-977-1. Manske K.A., Reindl D.T., Klein S.A., 2001, Evaporative Condenser Control in Industrial Refrigeration Systems, International Journal of Refrigeration, 24, 676-691. Martinez-Patino J., Nunez M.P., Hernandez-Figueroa M.A., Martinez A.P., 2014, Flexible Operation of Cooling System for Reducing Energy Consumption, Chemical Engineering Transactions, 39, 289 294. National Bureau of Statistics of China, 2015, China Statistical Yearbook 2015, Beijing, China. ISBN: 978-7- 5037-7638-0. Shapiro Y., Pandolf K.B., Sawka M.N., Toner M.M., Winsmann F.R., Goldman R.F., 1982, Auxiliary Cooling: Comparison of Air-Cooled vs. Water-Cooled Vests in Hot-Dry and Hot-Wet Environments, Aviation Space & Environment Medicine, 53, 785-789. Serth R.W., Lestina T.G., 2014, Process Heat Transfer: Principles, Applications and Rules of Thumb (2nd Edition), Elsevier/Academic Press, USA, 609 ps. ISBN: 978-0-12-397195-1. Sun L.Y., Ma Z.H., Wang Z.G., Zhang J.C.(Ed.), 2015, Thermal Design of Heat Exchangers, Beijing, China, 386 p, ISBN: 978-7-5114-3225-4. Wu Z.Y., 2013, Design of Industrial Circulating Cooling Water System, Industrial Water & Wastewater, 44, 60-61.