South Carolina Department of Labor, Licensing and Regulation Division of Labor Office of Occupational Safety and Health Columbia, South Carolina 29211

Similar documents
National Electrical Code

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Portable Generator Safety

UNOFFICIAL COPY OF HOUSE BILL 1406 A BILL ENTITLED

UNOFFICIAL COPY OF HOUSE BILL 1202 EMERGENCY BILL 5lr2923

UNOFFICIAL COPY OF SENATE BILL 464 A BILL ENTITLED

Notice That Particular Low Voltage or Extra-low Voltage Fittings or Appliances are Declared Medium Risk Articles

2011 and 2014 National Electrical Code Changes Residential Only

An Urgent Bulletin from CSA Group

SENATE, No STATE OF NEW JERSEY. 214th LEGISLATURE INTRODUCED DECEMBER 9, 2010

CHAPTER 14 ELECTRICAL CODE

[Third Reprint] ASSEMBLY, No. 516 STATE OF NEW JERSEY. 211th LEGISLATURE PRE-FILED FOR INTRODUCTION IN THE 2004 SESSION

Issue Update: Revised Recommended Language for Verification Contracts and Statements for Recycling Appliances and Vehicles

Installation and Operation of Model CS X-ray Cabinet. 11 Emery Avenue Randolph, NJ Tel.:

An Urgent Bulletin from CSA Group

ll. Consistency Questions

A WORD ABOUT PORTABLE ELECTRIC GENERATORS

Deemed to Comply Standards

NORTH CAROLINA. Downloaded (l) For each nursing unit, or fraction thereof on each floor, the following shall be provided:

ENERGY STAR Program Requirements. Freezers

California State University Bakersfield Radiation Safety Program Revised November 2017

SOUTH AFRICAN NATIONAL STANDARD

COMMISSION DELEGATED REGULATION (EU) /... of XXX

Luminaires Part 2-4: Particular requirements Portable general purpose luminaires

10606 Bloomfield Ave Santa Fe Springs, CA USA

VOLUNTARY PROCESSING STANDARD FOR RECYCLERS OF MAJOR APPLIANCES PS01

ELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED

Exhibit A. Mechnical, Plumbing, and Electrical Plan Check and Inspection Fees. Total Cost Per Unit FEE TYPES MECHANICAL PERMIT FEES

SUBCHAPTER 6L - BARBER SHOPS

ABSTRACT. State adoption is not required, See Paragraph V. Directorate of Compliance Programs. 200 Constitution Avenue, NW Washington, DC 20210

PROVINCE OF BRITISH COLUMBIA ORDER OF THE LIEUTENANT GOVERNOR IN COUNCIL

GENERAL ASSEMBLY OF NORTH CAROLINA SESSION 2007 SESSION LAW SENATE BILL 1924

Options for addressing City of Edmonds Alternatives to Ecology s Required Changes addressing Edmonds Marsh Buffers and Setbacks.

CENTRAL KITSAP SCHOOL DISTRICT BOARD PROCEDURE


1 of 1 DOCUMENT. NEW JERSEY REGISTER Copyright 2009 by the New Jersey Office of Administrative Law

SUBSIDIARY LEGISLATION STEAM AND HOT WATER BOILERS REGULATIONS

SUBJECT: Effective Date: Procedure Number:

TOM BURNS, PLANNING DIRECTOR

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

Fire Prevention Plan for Xavier Armory 3908 Winding Way

Laboratory Authorization Certificate

Bulletin An application for inspection not required Rule 2-005

CONTINUING EDUCATION FOR OREGON ELECTRICIANS. AMERICAN ELECTRICAL INSTITUTE PO Box Spokane, WA

Information Bulletin

ACKNOWLEDGEMENT. IIAR expresses its deepest appreciation to these authors for their contributions for the betterment of the industry.

DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL

CONTROLLED GOODS AND THE APPLICABLE SAFETY STANDARDS PART I DOMESTIC OR HOUSEHOLD APPLIANCES AND SIMILAR ELECTRICAL APPLIANCES

Electrical Hazards and NFPA-70E: Protecting Your Employees

AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND SINGLE-SPLIT

City of San Ramon. Zoning Ordinance. Adopted: October 27, Latest Revisions Effective: March 28, 2018

COMMISSION REGULATION (EU) / of

ON A POSSIBLE COMMISSION REGULATION AMENDING COMMISSION REGULATION (EC)

UPDATED: DECEMBER 28, 2018 U.S. DEPARTMENT OF ENERGY (DOE) WALK IN COOLER & FREEZER ENERGY EFFICIENCY RULEMAKING SUMMARY & FREQUENTLY ASKED QUESTIONS

U.S. DEPARTMENT OF ENERGY (DOE) WALK-IN COOLER & FREEZER ENERGY EFFICIENCY RULEMAKING SUMMARY & FREQUENTLY ASKED QUESTIONS. Rulemaking History

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

An Urgent Bulletin from CSA Group

WIRING AND PROTECTION

Emergency Generator Safety

Guidelines accompanying:

2009 ELECTRICAL CODE REQUIREMENTS

TABLE 3A BUILDING PERMIT AND PLAN REVIEW FEES

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

INVITATION TO QUOTE. Page 1 of 7. Fire & Emergency Safety Plan Control Number: 2018-CFS-003 Issue Date: March 7, Purpose

Title: Electrical Safety Effective Date: 11/28/2014 Control Number: THG_0038 Revision Number: 1 Date: 10/22/2015 Annual Review Completed: 5/13/2015

Fire Prevention Plan for Alumni Center 1507 Dana Avenue

IOWA STATE FIRE MARSHAL DIVISION Attn: Licensing Administrator

Safety requirements for voltage testing instruments

INTERNATIONAL STANDARD

BRAMPTON FLOWERTOWN SECONDARY PLAN Area 6

1. A fire certificate is issued under Section 76 of the Occupational, Safety and Health ActNo. 28 of 2005.

CLASSIFIED PERSONNEL POSITION AVAILABLE POSTED: NOVEMBER 28, 2017 OPEN: UNTIL FILLED HVAC TECHNICIAN

COMMERCIAL PERMIT APPLICATION AND CHECKLIST. Depending on the scope of your project, the following submittal requirements will apply:

Requirements for ships carrying hydrogen and compressed natural gas vehicles

For more information on the MARR program or any questions on the product list, please refer to or contact MARR at

INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH

INTERNATIONAL STANDARD

ENCLOSURE COOLING. Glossary

INTERNATIONAL STANDARD

Building & Safety PERMIT APPLICATION

SECTION CENTRIFUGAL WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

Notes From the Commish

Iowa Electrical Examining Board Division of the State Fire Marshal s Office

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015

ENERGY CONTROL LOCKOUT/TAGOUT PROGRAM PLAN

Copy of marking plate:

LANDSCAPE MAINTENANCE WORKER I LANDSCAPE MAINTENANCE WORKER II

42 USC NB: This unofficial compilation of the U.S. Code is current as of Jan. 4, 2012 (see

Energy Audits. Central Wisconsin Electric Cooperative.

FACTORIES ORDINANCE (CAP.

The U.S. Appliance Standards Program. Building Technologies Office Energy Efficiency and Renewable Energy United States Department of Energy

PROVINCE OF BRITISH COLUMBIA ORDER OF THE LIEUTENANT GOVERNOR IN COUNCIL

Energy Efficiency Labelling

INTERNATIONAL STANDARD

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

Your Personal Energy Audit Data Table, completed (handwritten is acceptable) A typed paragraph or two addressing each of the following topics.

22 (Second Section) OFFICIAL JOURNAL Friday, September 10th, 2010 MINISTRY OF ENERGY

Please make yourselves familiar with the changes and start implementing them immediately so you can be better prepared for June 30 th, 2018.

This is a preview - click here to buy the full publication

Transcription:

South Carolina Department of Labor, Licensing and Regulation Division of Labor Office of Occupational Safety and Health Columbia, South Carolina 29211 OSH Program Directive Number 89-1910.304/1926.404-1/1 Subject: Clarification of Subarticle 6, Sections 1910.304 (f) (4) and (f) (5) (v) (c) and Subarticle 7, Sections 1926.404 (f) (6) and (f) (7) (iv) (c), Rules and Regulations, Commissioner of Labor, State of South Carolina. Cross Reference to Federal Standards: 29 CFR 1910.304 (f) (4) and (f) (5) (v) (c) and 29 CFR 1926.404 (f) (6) and (f) (7) (iv) (c). Background: This directive clarifies and provides additional information for citing under Subarticle 6, Sections 1910.304 (f) (4) and (f) (5) (v) (c) and Subarticle 7, Sections 1926.404 (f) (6) and (f) (7) (iv) (c). This directive replaces OSH Program Directive number 81-1910.304/1926.404-1/1, dated June 12, 1981. Several professional electrical engineers were contacted in regards to these sections, and the opinions expressed by them were unanimous in agreement with the interpretations set forth in this program directive. a. Sections 1910.304 (f) (4) and 1926.404 (f) (6): Both of these sections are identical and read as follows: Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous. b. Sections 1910.304 (f) (5) (v) (c) and 1926.404 (f) (7)(iv) (c): 1. Section 1910.304 (f) (5) (v) (c) reads as follows: (c) If the equipment is of the following types: (1) Refrigerators, freezers and air-conditioners; (2) Clothes-washing, clothes-drying and dishwashing machines, sump pumps, and electrical aquarium equipment; (3) Hand-held motor-operated tools;

(4) Motor operated appliances of the following types: Hedge clippers, lawn mowers, snow blowers, and wet scrubbers; (5) Cord- and plug-connected appliances used in damp or wet locations or by employees standing on the ground or on metal floors or working inside metal tanks or boilers; (6) Portable and mobile X-ray and associated equipment; (7) Tools likely to be used in wet and conductive locations; and (8) Portable head lamps. Tools likely to be used in wet and conductive locations need not be grounded if supplied through an isolating transformer with an ungrounded secondary of not over 50 volts. Listed or labeled portable tools and appliances protected by an approved system of double insulation, or its equivalent, need not be grounded. If such a system is employed, the equipment shall be distinctively marked to indicate that the tool or appliance utilizes an approved system of double insulation. 2. Section 1926.404 (f) (7) (iv) (c) reads as follows: (c) If the equipment is one of the types listed in paragraphs (f) (7) (iv) (c) (1) through (f) (7) (iv) (c) (5) of this section. However, even though the equipment may be one of these types, it need not be grounded if it is exempted by paragraph (f) (7) (iv) (c) (6). (1) Hand held motor-operated tools; (2) Cord- and plug-connected equipment used in damp or wet locations or by employees standing on the ground or on metal floors or working inside of metal tanks or boilers; (3) Portable and mobile X-ray and associated equipment; (4) Tools likely to be used in wet and/or conductive locations; and (5) Portable heat lamps.

(6) Tools likely to be used in wet and/or conductive locations need not be grounded if supplied through an isolating transformer with an ungrounded secondary of not over 50 volts. Listed or labeled portable tools and appliances protected by a system of double insulation, or its equivalent, need not be grounded. If such a system is employed, the equipment shall be distinctively marked to indicate that the tool or appliance utilizes a system of double insulation. Interpretation: a. Sections 1910.304 (f) (4) and 1926.404 (f) (6) are identical and are not to be used to determine which pieces of cord-and plugconnected electrical equipment is required to be grounded, nor was it intended to do so. Their purpose is to ensure compliance with the conditions stated and are to be cited only for such conditions. Three examples that are to be cited under either of these sections are (1) the use of an ungrounded extension cord to supply power to a tool or appliance required to be grounded: (2) a two-wire receptacle that is supplying a tool or appliance required to be grounded; and (3) a three-wire receptacle without a ground that is supplying a tool or appliance required to be grounded. b. Sections 1910.304 (f) (5) (v) (c) and 1926.404 (f) (6) (iv) (c) must be used in conjunction with Sections 1910.304 (f) (5) (v) and 1926.404 (f) (7) (iv), respectively, which, in general, states that under the conditions described in Sections 1910.304 (f) (5) (v) (c) and 1926.404 (f) (7) (iv) (c), exposed noncurrentcarrying metal ports of cord-and plug-connected equipment which may become energized shall be ground. c. Section 1910.304 (f) (5) (v) (c) (1) refers specifically to pieces of electrical equipment containing refrigeration or compressor units that must be grounded. This requirement pertains not only to household type refrigerators, but to water cooler refrigerators, horizontal type drink cooler refrigerators and vertical type drink or food refrigerators. All types of cord- and plug-connected freezers and air-conditioners can also be cited under this section. d. Sections 1910.304 (f) (5) (v) (c) (2) also refers to five (5) specific pieces of electrical equipment that must be grounded. This requirement is self-explanatory.

e. Section 1910.304 (f) (5) (v) (c) (3) and 1926.404 (f) (7) (iv) (c) (1) refers to hand-held, motor-operated tools that are required to be grounded. Each tool must be motor-operated tools that are required to be grounded. Each tool must be motor-operated and held in or by the hand. Hand-held applies to any type of motor-operated tool that is hand-held for guiding purposes as well as those that can be held in the hand. f. Section 1910.304 (f) (5) (v) (c) (4) refers to specific pieces of electrical equipment that must be grounded. This requirement is self-explanatory. g. Sections 1910.304 (f) (5) (v) (c) (5) and 1926.404 (f) (7) (iv) (c) (2) refers to cord- and plug-connected appliances and to cord- and plug-connected equipment, respectively, used in four (4) specific types of conductive locations that must be grounded. This is the only general reference to appliances in Section 1910.403 (f) (5) (v) (c) and to equipment in 1926.404 (f) (7) (iv) (c). Unless the appliance or the equipment is one of the specific types stated in other paragraphs of Sections 1910.304 (f) (5) (v) (c) or 1926.404 (f) (7) (iv) (c), respectively, then Sections 1910.304 (f) (5) (v) (c) (5) and 1926.404 (f) (7) (iv) (c) (2) are the only citable sections for cord- and plug-connected appliances and equipment, respectively and only if they are located in one of the specific conductive locations stated. For example, if the appliance or equipment body and motor housing is made of plastic and the only metal parts are screws holding the housing together, and such screws are recessed so that they are not normally exposed to the hands during normal operation, then the appliance or equipment body is not likely to become energized and, therefore, it is not citable. Also, the grounding of the plastic housing of the motor would be impracticable. h. Sections 1910.304 (f) (5) (v) (c) (6) and 1926.404 (f) (7) (iv) (c) (3) refers specifically to any portable and mobile X-ray and its associated equipment. This requirement is self-explanatory. i. Sections 1910.304 (f) (5) (v) (c) (7) and 1926.404 (f) (7) (iv) (c) (4) refers to the grounding of tools likely to be used in both wet and conductive locations that would not be specifically covered under Sections 1910.304 (f) (5) (v) (c) (5) and 1926.404 (f) (7) (iv) (c) (2). There are several reasonable explanations for interpreting the phrase in wet and conductive locations in Section 1910.304 (f) (5) (v) (c) (7) to mean both wet and conductive locations. One reason is that this phrase is

written in the concept that it covers two conditions, a wet location and a conductive location, for there are numerous more conductive locations that are an electrical hazard which are not wet. All wet locations are normally considered to be conductive locations. Secondly, when the construction electrical standards were revised, Section 1926.404 (f) (7) (iv) (c) (4) was changed to read wet and/or conductive locations, making it very plain that the intent is to cover both wet locations and conductive locations. j. Sections 1910.304 (f) (5) (v) (c) (5) and 1926.404 (f) (7) (iv) (c) (5) refers to portable handlamps that must be grounded. This requirement is self-explanatory. k. The last paragraph of Section 1910.304(f) (5) (v) (c) and Section 1926.404 (f) (7) (iv) (c) (6) both allow tools used in wet and conductive locations that are supplied through an isolating transformer with an unground secondary of not over 50 volts or double insulated listed tools and listed portable appliances which are distinctively marked as such, not to be grounded. Effective Date: This instruction is effective upon receipt and will remain in effect until cancelled or superseded by amendments to the Rules and Regulations. William M. Lybrand, Director January 5, 1990