Heimdall Radar Traffic Detector

Similar documents
Heimdall Radar Traffic Detector

Heimdall Radar Traffic Detector

Heimdall Radar Traffic Detector

METHOD STATEMENT. Process. Document Authorisation Role Name Function Signed Prepared by:

Performance Specification for Above Ground On- Crossing Pedestrian Detection Systems

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

600 Range Dialer Installation Manual. Version 1.0

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Networked Access Control Panel. Installation Guide

Public Safety DAS Annunciator Panel

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Operation and Maintenance Manual

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

AE Liter Tank with Pump Installation Guide

Installation and user manual for the BiWire / Conventional Repeater Panel

Installation, Operating and Servicing Instructions. Opus 800 Electric Cook & Hold Salamander OE8306

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

Interface Modules for SENTRI

New Silent Alert Fire Safe System

IRIS Touch 200 Range Dialler Installation Manual. Version 1.4

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Silent Alert Fire Safe System

D-Tect 2 GJD300 Quad PIR Movement Detector

T-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION / INSTALLATION

Installing a Fast Oven Upgrade Kit

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Safety Photo Beam UL MONITORED DEVICE

TPM Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal

Intelligent Security & Fire Ltd

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

SecuriSens LIST Product Catalogue 2015

RTD TEMPERATURE SENSING SYSTEM

Installation and Operation Manual Low Power (LP) DC Power System

5000 INSTALLATION GUIDE

METEOROLOGICAL INSTRUMENTS

Specification for Rising Bollards Control System

Engineering Guideline. pac- Carriers Type Universal

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

CW9000 Wireless Fire System. Installation Manual

THINLINE TL2 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

RS485 MODBUS Module 8AI

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

SERVICE INSTRUCTIONS FOR. Fire Alarm System MINI-2000

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

Operating instructions Page 12

AGA TOTAL CONTROL. Model No s: TC3 & TC5 (ROOM VENT OPTION)

M2500 Engine Controller Installation Manual

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Fire Control Panel FS4000

FIRERAY 5000 range USER GUIDE

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for vented systems.

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections.

Flostop TS D7E and A8E. Operation Manual

DM60-xxx Antennas. 1. Assembly. Installation Instruction for CMAX Antennas

Replacing GWR Sensor Electronics

Greentrol Automation, Inc.

Installation Instruction Manual ILS-S

Operating Instructions

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Installation Datasheet

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Maintenance Manual ALARM SHELF 19D902821P1 & P2. ericssonz LBI-38496C. TABLE OF CONTENTS (Vendor Documentation)

Door Release Power Supply

21-light Remote Annunciator. Owner s Manual

Fratech Multipath-IP

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

METEOROLOGICAL INSTRUMENTS

FlexZone SIX STEPS TO AFFORDABLE PERIMETER PROTECTION EASY TO INSTALL LOW TOTAL COST OF OWNERSHIP HASSLE-FREE OPERATION & MAINTENANCE HOW-TO GUIDE

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

RMS/RPX Reader. User Manual

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

Introduction... 1 System Overview... 1 System Diagram... 2

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Installation, Operating and Servicing Instructions

Ethernet General Purpose

MC-100V & BC-100V Operation / Installation Manual

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

LeakSafe. solutions. WaterSwitch2. Installation Instructions

Application, Installation, Operation & Maintenance Manual

ITS specification Over-height vehicle detection (ITS-08-02)

Ax60+ Multi-Gas. Service Manual

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

Ax60 Carbon Dioxide Detector

Movement Detector GJD 300

ACCURATE ELECTRONICS INC

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

Transcription:

Heimdall Radar Traffic Detector Selectable Speed Detector Installation Guide Document Authorisation Role Name Function Signed Prepared by: R. Martin Project Support Manager Reviewed by: A. Rhodes Lead Product Engineer Reviewed by: A. White Product Design Manager Authorised by: C. Whipps Technical Support Manager Document record Issue Date Comment/Revision Details Number 1 04/04/08 Initial Release 2 15/07/11 Document Updated 3 23/09/11 Document Updated This document is electronically held. This is an unpublished work, the copyright of which vests in Siemens Plc. All rights reserved. The information contained herein is the property of Siemens Plc. and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied. Part Number: 667/HB/31900/320 Issue 3 Page 1 of 11

Contents 1 General...3 1.1 Part number...3 1.2 Tooling requirements...3 1.3 Performance Details...3 1.4 Electrical Details...4 2 Detector Installation...5 2.1 Electrical Connections...5 2.1.1 9-Pin Buccaneer connector...5 2.1.2 Output Cable (Standard)...6 2.1.3 Output Cable (with SiTOS)...6 2.1.4 Output Cable (with isolated 2 nd detector O/P)...6 2.2 DIP Switch Settings...7 2.3 Detector mounting methods...8 2.4 Detector alignment...9 Installation Quick Reference Guide...10 Part Number: 667/HB/31900/320 Issue 3 Page 2 of 11

1 General The Heimdall Above Ground Vehicle Detectors have been developed to provide the complete range of detection systems used in a modern traffic/pedestrian control installation. They incorporate state of the art radar antenna designs tailored to the specific requirements for each detector type. All detectors are housed within the same style of enclosure and are of minimal size to reduce the eye clutter associated with older types of equipment. All detectors can be readily installed onto both new and existing traffic signal control poles. Detectors come supplied with a standard interface cable together with the HA specified Bulgin Buccaneer connector. Existing sites can easily be upgraded with the Heimdall detector as the detector is compatible with existing above ground units. 1.1 Part number Part Number 667/1/31900/02x Description Selectable Speed Detector Note: In the above table x relates to the particular option installed, thus: 0 Basic Detector 1 Basic Detector with RS485 Interface (SiTOS) 2 Basic Detector with Wireless Interface 3 Basic Detector with 2 nd Output 4 Basic Detector with 2 nd Output + Wireless Interface 1.2 Tooling requirements As well as a standard Installers tool kit, the following are required when installing or maintaining a Heimdall Detector: 1. 2mm Allen key for side access door and lid 2. T-8 Torx driver alternative tool for side access door and lid. 3. 13mm Socket spanner - for angular adjustment and installation of detector. 4. 19mm Ring spanner - for cable gland (DE only). 5. Small flat bladed screwdriver for DIP switch adjustment. 1.3 Performance Details Operating Range: At least 10m to 35m from the Stop Line Lane Width: Typically 7.0m Vehicle Approach Speed Range: 8Km/Hr (5 MPH) to greater than 112Km/Hr (70 MPH). 8Km/Hr (5 MPH) to 112Km/Hr (70 MPH) by simple DIP Speed Threshold Settings: switch settings. Can be configured from 8Km/hr to 150Km/hr in 1 Km/hr increments via the serial terminal facility. Detector Location: Can be located on either the nearside primary signal pole or the off-side primary signal pole. Detector Mounting Height Range: Various Pole heights (above the ground) can be accommodated from 3.3m to 4.0m Part Number: 667/HB/31900/320 Issue 3 Page 3 of 11

1.4 Electrical Details The Heimdall detector is capable of being powered from either: (a) 24V AC ± 20% (48 to 63 Hz), or (b) 10.8V to 24.8V DC (c) 24V Full wave rectified ± 20%. From Siemens ELV controller For information relating to the following: 1. Power consumption requirements of this model. 2. 24V AC & DC power supply options. 3. Permissible detector supply cable lengths. 4. Calculating 24V AC & DC supply cable feeds. 5. Cable length look up tables. Please refer to the Heimdall General Handbook (667/HB/31900/000). Part Number: 667/HB/31900/320 Issue 3 Page 4 of 11

2 Detector Installation 2.1 Electrical Connections Important Notes: a) When connecting this detector to a 24V AC source, please ensure that the 24V AC source is derived from an earthed secondary transformer (as used in standard traffic installations). b) Particular attention should be paid to the correct termination of the power supply wires. The RED wire should be used for the 24V AC/DC supply feed and the Black wire for the EARTHED supply return. c) When using a 24V AC supply, only use battery powered interface equipment (e.g. laptop, PDA). Do not connect mains powered/connected equipment to the Heimdall series of detectors, as this will cause the detectors to fail. d) When installing this detector with a Siemens ELV controller or a Siemens ELV controller additional supply, please ensure the RED wire of the interface cable is connected to the POSITIVE (common) connector, the BLACK wire is connected to the NEGATIVE (-24VDC) source and the GREEN (screen) is connected to the POSITIVE (common) connector. Figure 2-1 Connection of Heimdall detector to Siemens ELV controller 2.1.1 9-Pin Buccaneer connector All Heimdall detectors are equipped with a captive lead and a standard 9 pin Buccaneer connector (see Figure 2-2, below). The pin out for this connector is as specified in the Highways Agency Specifications: TR2505, TR2506 & TR2507. The Heimdall series of detectors provide additional facilities, to that specified in the HA documents, using the spare connections within the 9 way connector. These are outlined in the sections below. 3 4 5 2 9 6 1 8 7 Figure 2-2 Buccaneer Bulkhead Connector (front view) Part Number: 667/HB/31900/320 Issue 3 Page 5 of 11

For the Helios Signal Head the Heimdall bulkhead connector cable is generally fitted to the topmost indent on the red Aspect (either side). The hole should be drilled using the rear drill start point. For other signal head suppliers, please refer to the relevant documentation supplied with their products. The wires from this connector should be terminated in accordance with the details shown in the sections below. 2.1.2 Output Cable (Standard) Table 1: Output Cable (Standard) configuration for variants: 667/1/31900/xx0 & /xx2. Connector Pin No. Comment Colour Code 1 Detector Supply (24V AC/DC) Red 2 Detector Supply Common (0v) Black 3 Screen Green 4 Detector O/P #1&2 (Common) White 5 Detector O/P #1 (Normally Open)* Yellow 6 Detector O/P #1 (Normally Closed)* Blue 7 Not Used Violet 8 Not Used Orange 9 Not Used Brown Note: * This signal condition refers to the state when the detector is un-powered (detect state). 2.1.3 Output Cable (with SiTOS) Table 2: Output Cable (with SiTOS) configuration for variant: 667/1/31900/xx1. Connector Pin No. Comment Colour Code 1 Detector Supply (24V AC/DC) Red 2 Detector Supply Common (0v) Black 3 Screen/ RS485 Ground Green 4 Detector O/P #1&2 (Common) White 5 Detector O/P #1 (Normally Open)* Yellow 6 Detector O/P #1 (Normally Closed)* Blue 7 Detector O/P #2 (Normally Open)* Violet 8 SiTOS RS485 (Terminal A) Orange 9 SiTOS RS485 (Terminal B) Brown Note: * This signal condition refers to the state when the detector is un-powered (detect state). 2.1.4 Output Cable (with isolated 2 nd detector O/P) Table 3: Output Cable (with isolated 2 nd detector O/P) configuration for variants: 667/1/31900/xx3 & /xx4) Connector Pin No. Comment Colour Code 1 Detector Supply (24V AC/DC) Red 2 Detector Supply Common (0v) Black 3 Screen Green 4 Detector O/P #1 (Common) White 5 Detector O/P #1(Normally Open *) Yellow 6 Detector O/P #1(Normally Closed *) Blue 7 Detector O/P #2 (Common) Violet 8 Detector O/P #2 (Normally Open *) Orange 9 Detector O/P #2 (Normally Closed *) Brown Note: * This signal condition refers to the state when the detector is un-powered (detect state). Part Number: 667/HB/31900/320 Issue 3 Page 6 of 11

2.2 DIP Switch Settings All Heimdall detectors are equipped with switches that enable the unit to be installed, for the majority of applications, without the need for any special terminal (handset) equipment. Access to these switches is gained by removal of the side cover. Before removal, note the cover s orientation and ensure it is replaced the same way round. The switches on the first PCB (Digital Processor) control the basic functions of this detector and are as listed in the following table: Note: Default settings are with all DIP switches set to 0 / OFF. DIP Switch Number 1 2 3 4 5 6 7 8 SW 1,2,3 & 4: Speed Threshold: Km/H (Mph) 0,0,0,0 = 8 (5) 1,0,0,0 = 72 (45) 0,0,0,1 = 16 (10) 1,0,0,1 = 80 (50) 0,0,1,0 = 24 (15) 1,0,1,0 = 89 (55) 0,0,1,1 = 32 (20) 1,0,1,1 = 97 (60) 0,1,0,0 = 40 (25) 1,1,0,0 = 105 (65) 0,1,0,1 = 48 (30) 1,1,0,1 = 113 (70) 0,1,1,0 = 56 (35) 1,1,1,0 = 121 (75) 0,1,1,1 = 64 (40) 1,1,1,1 = Speed set by Eng. Terminal SW 5: O/P Hold Time 0 = Standard hold time of 1000mS applies. 1 = Terminal applied hold time applies. SW 6: Detection Range 0 = Full 1 = Reduced SW 7: DFM 0 = Default monitor time (20hours inactive) 1 = fault monitor time is set by the Engineer s Terminal SW 8: Remote Configuration 0 = Disabled 1 = Enabled Key: 0 OFF 1 ON * Unidirectional detection ** Bidirectional detection Note: The switches provided on the second PCB (Special I/O) control the operation of the Siemens Serial Interface (SiTOS) and detail of these settings can be found in the Heimdall General Handbook (667/HB/31900/000). Part Number: 667/HB/31900/320 Issue 3 Page 7 of 11

2.3 Detector mounting methods 1. When mounting to a Siemens Helios Signal Head, the Heimdall Above Ground Detector can be mounted in the slot on the top bracket, as shown in Figure 2-3, below. Figure 2-3 2. Alternatively, a side mounting bracket can be fitted on top of the head fixing bracket, thus providing a slot and two holes for attaching the detector to, as shown in Figure 2-4, below. Figure 2-4 3. Existing signal heads from a range of manufacturers may employ a mounting position which causes the detector to be masked by the head s backing board. In this situation a Heimdall Spacer Bracket Kit (667/1/31942/000) must be used. A typical installation of this kind is shown in Figure 3, below. Figure 2-5 Part Number: 667/HB/31900/320 Issue 3 Page 8 of 11

2.4 Detector alignment When aligning the detector always ensure the following: 1. There is a good line of site between the detector and point of detection with no obstructions such as signs, trees, etc. 2. There is sufficient strain relief and no risk of entrapment or pinching of the detector cables when installing or aligning the detector on a pole. 3. The detector is located on a suitable mounting pole located alongside the detection zone 4. The detector is aimed at a position approximately 25 metres from the mounting pole. Figure 2-6 Typical Detection Zone Part Number: 667/HB/31900/320 Issue 3 Page 9 of 11

Installation Quick Reference Guide Electrical Connections Important Notes: a) When connecting this detector to a 24V AC source, please ensure that the 24V AC source is derived from an earthed secondary transformer (as used in standard traffic installations). b) Particular attention should be paid to the correct termination of the power supply wires. The RED wire should be used for the 24V AC/DC supply feed and the Black wire for the EARTHED supply return. c) When using a 24V AC supply, only use battery powered interface equipment (e.g. laptop, PDA). Do not connect mains powered/connected equipment to the Heimdall series of detectors, as this will cause the detectors to fail. All Heimdall detectors are equipped with a captive lead and a standard 9 pin Buccaneer connector. The pin out for this connector is as specified in the Highways Agency Specifications: TR2505, TR2506 & TR2507. The Heimdall series of detectors provide additional facilities, to that specified in the HA documents, using the spare connections within the 9 way connector. For the Helios Signal Head the Heimdall bulkhead connector cable is generally fitted to the topmost indent on the red Aspect (either side). The hole should be drilled using the rear drill start point. For other signal head suppliers, please refer to the relevant documentation supplied with their products. The wires from this connector should be terminated in accordance with the details shown in the table below. Output Cable (Standard) Output Cable (Standard) configuration for variants: 667/1/31900/xx0 & /xx2. Connector Pin No. Comment Colour Code 1 Detector Supply (24V AC/DC) Red 2 Detector Supply Common (0v) Black 3 Screen Green 4 Detector O/P #1&2 (Common) White 5 Detector O/P #1 (Normally Open)* Yellow 6 Detector O/P #1 (Normally Closed)* Blue 7 Not Used Violet 8 Not Used Orange 9 Not Used Brown Note: * This signal condition refers to the state when the detector is un-powered (detect state). For pinout and wiring details of the output cable for either the SiTOS or 2 nd output detector options, please refer to section 2.1.3 & 2.1.4 of this installation guide. DIP Switch Settings All Heimdall detectors are equipped with switches that enable the unit to be installed, for the majority of applications, without the need for any special terminal (handset) equipment. Access to these switches is gained by removal of the side cover. Before removal, note the cover s orientation and ensure it is replaced the same way round. The switches on the first PCB (Digital Processor) control the basic functions of this detector and are as listed in the following table: Note: Default settings are with all DIP switches set to 0 / OFF. DIP Switch Number 1 2 3 4 5 6 7 8 SW 1,2,3 & 4: Speed Threshold: Km/H (Mph) 0,0,0,0 = 8 (5) 1,0,0,0 = 72 (45) 0,0,0,1 = 16 (10) 1,0,0,1 = 80 (50) 0,0,1,0 = 24 (15) 1,0,1,0 = 89 (55) 0,0,1,1 = 32 (20) 1,0,1,1 = 97 (60) 0,1,0,0 = 40 (25) 1,1,0,0 = 105 (65) 0,1,0,1 = 48 (30) 1,1,0,1 = 113 (70) 0,1,1,0 = 56 (35) 1,1,1,0 = 121 (75) 0,1,1,1 = 64 (40) 1,1,1,1 = Speed set by Eng. Terminal SW 5: O/P Hold Time 0 = Standard hold time of 1000mS applies. 1 = Terminal applied hold time applies. SW 6: Detection Range 0 = Full 1 = Reduced SW 7: DFM 0 = Default monitor time (20hours inactive) 1 = fault monitor time is set by the Engineer s Terminal SW 8: Remote Configuration 0 = Disabled 1 = Enabled Key: 0 OFF 1 ON * Unidirectional detection ** Bidirectional detection Note: The switches provided on the second PCB (Special I/O) control the operation of the Siemens Serial Interface (SiTOS) and detail of these settings can be found in the Heimdall General Handbook (667/HB/31900/010). Part Number: 667/HB/31900/320 Issue 3 Page 10 of 11

Detector Mounting Methods 1. When mounting to a Siemens Helios Signal Head, the Heimdall Above Ground Detector can be mounted in the slot on the top bracket, as shown in Figure 1, below. 2. Alternatively, a side mounting bracket can be fitted on top of the head fixing bracket, thus providing a slot and two holes for attaching the detector to, as shown in Figure 2, below. 3. Existing signal heads from a range of manufacturers may employ a mounting position which causes the detector to be masked by the head s backing board. In this situation a Heimdall Spacer Bracket Kit (667/1/31942/000) must be used. A typical installation of this kind is shown in Figure 3, below. Figure 1 Figure 2 Figure 3 Detector Alignment When aligning the detector always ensure the following: 1. There is a good line of site between the detector and point of detection with no obstructions such as signs, trees, etc. 2. There is sufficient strain relief and no risk of entrapment or pinching of the detector cables when installing or aligning the detector on a pole. 3. The detector is located on a suitable mounting pole located alongside the detection zone. 4. The detector is aimed at a position approximately 25 metres from the mounting pole. Part Number: 667/HB/31900/320 Issue 3 Page 11 of 11