Liebert CSU3000 Chiller

Similar documents
SECTION ROTARY-SCREW WATER CHILLERS

MACH N-407 Heat Pump Air-Cooled Chiller

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

.2 Section Waste Management and Disposal.

MAC N-407 Air-Cooled Chiller

SECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

Call us today! (800)

Call us today! (800)

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

Product Chillers A P P L I C AT I O N S

PACKAGED AIR COOLED Product Data Catalog

AIR COOLED PACKAGED CHILLER

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Call us today! (800)

30GT FLOTRONIC AIR-COOLED CHILLERS

MAC-120HE-03 Air-Cooled Chiller

SECTION AIR COOLED WATER CHILLERS

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

SECTION ROTARY SCREW WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

UNIFIED FACILITIES GUIDE SPECIFICATIONS

30GN FLOTRONIC II AIR-COOLED CHILLERS

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

C. Samples for Initial Selection: For units with factory-applied color finishes.

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

SECTION CENTRIFUGAL WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

Liebert Deluxe System/3

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

OACS Outdoor Air-Cooled Central Chillers

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

SECTION ROTARY SCREW WATER CHILLERS. B. Removal of Existing Refrigerant in Existing Chiller:

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

SECTION CHILLERS

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Water-Cooled Dual Compressor Screw Chiller

CONTENTS. B. System Design and Performance Requirements

1.2 REFERENCES - comply with the following codes and standards:

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

APPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS

SECTION AIR COOLED WATER CHILLERS (LESS THAN 150 TONS)

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

SECTION AIR COOLED WATER CHILLER

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Commercial High-Efficiency Condensing Units

Construction Standards Page

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Liebert Air-Cooled, Direct-Drive Drycoolers Technical Design Manual 50 Hz & 60 Hz

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

SECTION DOMESTIC WATER HEATERS

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

MEDICAL CHILLER SYSTEMS

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

SpaceKeeper Console (SKC)

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Owner s Manual Therma-Stor II Heat Recovery System

water to water heat pumps

CENTRAL SPLIT UNIT UNIC

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

PDF Created with deskpdf PDF Writer - Trial ::

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

SECTION CENTRIFUGAL WATER CHILLERS

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Guide Specifications for InRow Direct Expansion

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Trouble Shooting Guide PWA, 3-phase (D10571)

SECTION COMPUTER-ROOM AIR-CONDITIONERS

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

Trouble Shooting Guide FAA, 3-phase (D3631)

Precise Temperature Control; Compact Footprint

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

Liebert CRV Warranty Inspection Check Sheet

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

AIR COOLED CONDENSING UNITS IMPORTANT DESIGN FEATURES

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

Liebert Air-Cooled Fin/Tube Condensers

Transcription:

CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model, self-contained, factory assembled system. Provide unit(s) with matching, dual refrigeration systems to provide both primary and redundant sources of chilled water to the main-frame computer system. This system shall be provided such that each chiller module can cool the main-frame computer; the second chiller module serves as a stand-by module. 1.2 CT MODELS The main-frame coolant supply unit shall be a Liebert Model, self-contained, factory assembled system. Provide unit(s) with matching, dual refrigeration units to provide primary source of chilled water to the main-frame computer system. A third refrigeration module shall be provided to provide redundant cooling capacity. The packaged coolant supply unit for each model shall have the following built-in components. 1.3 SUBMITTALS Submittals shall be provided with the proposal and shall include: Single-Line Diagrams; Dimensional, Electrical, and Capacity data; Piping and Electrical Connection Drawings. 1.4 WARRANTY The system shall be provided with a warranty against defects in material and workmanship for a period of one year from the start up date, not to exceed eighteen months from the date of shipment. 1.5 QUALITY ASSURANCE The specified system shall be factory-tested before shipment. Testing shall include, but shall not be limited to: Quality Control Checks, Hi-Pot Test (two times rated voltage plus 1000 volts, per UL requirements), and Metering Calibration Tests. The system shall be designed and manufactured according to world class quality standards. The manufacturer shall be ISO 9001 certified. (R 3/96) 1

Liebert CSU3000 2.0 2.1 STANDARD FEATURES / ALL SYSTEMS 2.1.1 Cabinet and Frame Construction The frame shall be constructed of heliarc-welded tubular steel. It shall be painted using the autophoretic coating process for maximum corrosion protection. The exterior panels shall be insulated with a minimum of 1", 1 1/2 lb. density fiber insulation. All panels shall have captive, 1/4 turn fasteners and shall be removable for service access. The main unit color shall be, and the accent panel color shall be. The exterior panels shall be powder coated. 2.1.2 Coolant Piping The internal coolant piping shall include: isolating valves for each module, an expansion tank, water fill connection, pressurization connection and liquid-level sight glass; a circulating pump which shall provide GPM at feet of water total head; and a discharge check valve to prevent back flow. The supply and return connections shall be 2 1/8" O.D. copper for connection to RR or ES header assemblies. 2.1.3 High Voltage Electric Panel Each chiller module shall have a separate, self-contained high voltage electric panel. Each shall include a non-automatic, molded case circuit breaker that can be operated with the panel cover closed. The disconnect shall include a decorative trim to match the exterior trim of the unit. Each electric panel shall include starters, contactors, relays, transformers and dual-element fuses that protect each high-voltage circuit in the system. The electric panel shall be wired with one common electrical line connection. 2.1.4 Solid-State Control System Each of the solid state control systems shall be powered from separate, non interconnecting 24 volt power sources. Each chiller module control system shall include the following: Start/Stop button, Silence button for the audible alarm; Manual reset circuit breakers; Back-lighted monitor panel (no message is visible until lit.) The monitor panel shall display operating modes (Pump On, Cooling On) in white and alarm conditions in red. Alarm messages remain lit until the malfunction is corrected but the audible alarm may be silenced. If a second alarm condition occurs, the audible alarm shall sound again. The alarm panel shall activate with the following conditions: No Water Flow Low Water Temperature High Water Temperature High Compressor Head Pressure Loss of Power 2 Guide Specifications

CS/CD/CT Models (7.5 to 37 Tons) The control system shall automatically energize the stand-by chiller module whenever any of the alert conditions exist and energize the Stand-by On Other Failed message on the monitor panel. The solid-state plug-in alarm module shall include a Push-to-Test circuit for testing all operating and alarm mode messages as well as the audible alarm. An individual Push-to-Test button shall be provided to test each alarm condition. This will verify the function of the audible alarm, the lights and the switchover to the stand-by module. A reset button shall reset a module after the malfunction has been corrected. The control system shall also include a set of non-powered, normally open contacts for a remote customer alarm and two custom alarm inputs and visual messages to be customer specified. 2.1.5 Semi-Hermetic Compressors The compressor shall be semi-hermetic with a suction-gas cooled motor, vibration isolators, thermal overloads, oil sight glass, manual reset high pressure switch, pump-down low pressure switch, suction line strainer, reversible oil pumps for forced feed lubrication and a maximum operating speed of 1750 RPM. The minimum EER for the compressor shall be at ARI rated conditions (130 F SCT, 45 F SST, 15 F subcooling). Compressors may be suitable for capacity modulation in addition to hot gas bypass systems. 2.1.6 Refrigeration System Each refrigeration system shall be direct expansion with separate, fully insulated shell and tube evaporator. The refrigeration circuit shall include a hot gas muffler, liquid line filter drier, refrigerant sight glass and moisture indicator, and adjustable externally equalized thermostatic expansion valve, liquid line solenoid valve, hot gas bypass solenoid and valve to control compressor capacity at reduced load. All components of the system shall be factory connected with type L refrigeration copper tubing. 2.2 STANDARD FEATURES/ INDIVIDUAL SYSTEMS 2.2.1 Air Cooled Condenser Each chiller module shall be provided with a Liebert manufactured, air cooled condenser. The low-profile, propeller fan condenser shall be designed for vertical air flow and include an integral electrical panel. The condenser shall balance the heat rejection requirements of each module at F. The copper-tube, aluminum-fin coil shall be housed in a corrosion-resistant aluminum cabinet. LEE-TEMP Winter Control System The LEE-TEMP winter control system shall allow start-up and provide positive head-pressure control at ambients as low as -30 F. The LEE-TEMP package includes factory insulated receivers, refrigerant sight glasses, pressure relief valves, 3-way head-pressure control valves and roto-lock valve for isolating the refrigerant charge. All necessary electrical components shall be factory installed, connected, and calibrated. Any components required to be installed by the installing contractor shall be done at no additional cost to the owner. (R 3/96) 3

Liebert CSU3000 2.2.2 Water Cooled Condenser The water cooled condensers shall be cleanable, counterflow shell and tube with removable heads. Condensers shall be A.S.M.E. stamped for maximum refrigerant pressure of 400 PSI at 300 F. The unit shall require GPM of F water and have a maximum pressure drop of PSI. Water Regulating Valve The water-cooled condenser shall be factory piped with a head-pressure actuated water regulating valve (2-way) and a hand operated isolation valve. 2.2.3 Glycol Cooled Condenser The glycol-cooled condensers shall be cleanable, counterflow shell and tube with removable heads. Condensers shall be A.S.M.E. stamped for maximum refrigerant pressure of 400 PSI at 300 F. The unit shall require GPM of F 40% glycol and have a maximum pressure drop of feet of water. Glycol Regulating Valve The glycol-cooled condenser shall be factory piped with a head-pressure actuated water regulating valve (2-way with bypass) and a hand-operated isolated valve. Drycooler Each chiller module shall be provided with a Liebert-manufactured drycooler. The low-profile, propeller fan drycooler shall be designed for vertical air flow and include an integral electrical panel that contains all the necessary electrical components for both drycooler fans and glycol circulating pump. The condenser shall be designed for an outdoor ambient of F. The copper-tube, aluminum-fin coil shall be housed in a corrosion-resistant aluminum cabinet. Glycol Pump Package Each module shall be provided with a centrifugal pump mounted in a weatherproof, vented enclosure that matches the finish of the drycooler 2.3 GLYCOOL SYSTEMS (CS/CD MODULES ONLY) 2.3.1 Glycool Module The glycool system shall be a basic glycol cooled system plus the necessary components to eliminate compressor operation during low ambient conditions automatically. The glycool system shall include a fully proportional 3-way mixing valve, and a solenoid valve to control glycol flow. All the control circuitry necessary to operate the system shall be factory installed, connected and calibrated. 4 Guide Specifications

CS/CD/CT Models (7.5 to 37 Tons) 2.4 ALTERNATE WATER SOURCE (CS/CD MODELS ONLY) 2.4.1 AWS3000 Module The AWS3000 module shall provide a cooling capacity of BTU/HR when cooling GPM of coolant water to F. A chilled water source of GPM at F entering water temperature shall be required at a pressure drop of feet of water. The module shall contain a circulating pump having a rating of GPM at feet of water total head and a fully proportional 3-way mixing valve to maintain a constant leaving water temperature. The shell and tube heat exchanger and piping shall be factory insulated. The system shall utilize a separate electrical panel and be integrated with the matching compressorized module. 2.5 OPTIONAL EQUIPMENT / ALL SYSTEMS 2.5.1 Liqui-Tect Sensors (Max. 2 Per Unit) Provide (quantity) solid-state water sensors under the raised floor. The field installed sensor shall activate a red water under floor indicator and the audible alarm. 2.5.2 Liqui-Tector Panel Provide a Liqui-Tector panel to be centrally located in the computer room. It shall be capable of monitoring up to 20 remote Liqui-Tect sensors and other system related functions. 2.5.3 Locking Disconnect Switch The non-automatic molded case circuit breaker shall be mounted in the high voltage section of each electric panel. The switch shall be accessible from the outside of the unit with the accent panel closed and prevent access to the high voltage electrical components until switched to the OFF position. 2.5.4 Dual Power Supply The CSU3000 shall be provided with dual power supplies to enable the two modules to be separately powered. (Not available on CT Models.) 2.5.5 Floorstand The floorstand shall be constructed of a heliarc welded tubular steel frame. It shall have adjustable legs with vibration isolating pads. The floorstand shall be inches high. 2.5.6 Header Kit The CSU3000 shall be provided with a field installed (RR) (ES) header kit for connection of (RR) (ES) hoses. 2.5.7 Quick-Connect Hose Kits Provide with the CSU3000 system a complete hose kit capable of connecting the system to the CDU on the computer mainframe. The hose kit shall consist of flexible hoses, each feet in length, insulated with Armaflex type FR insulation or equal. The hose kit shall contain barbed fittings for connections at the supply and return headers of the chiller and factory-made connections on the other end with the proper male and female fittings to connect directly to the Coolant Distribution Unit. (R 3/96) 5

Liebert CSU3000 2.5.8 Information Gathering Module Provide an Information Gathering Module for CSU3000 that permits communication with a Liebert Sitemaster Model 200 or a Liebert SiteScan. The 3-module systems shall be equipped with interconnecting cable. 2.5.9 Separate Pump Power Connection Provide one 3-phase power connection for all pumps and controls, and one 3-phase power connection for all other loads. Two locking disconnects shall be provided with this option on single module units. Four locking disconnects shall be provided on dual module units. Six on triple module units. 2.5.10 Crankcase Heater A crankcase heater shall be provided to prevent the migration of refrigerant to the compressor during off cycles. 2.6 OPTIONAL EQUIPMENT CS/CD/CT MODELS 2.6.1 Capacity Control Valves The semi-hermetic compressor shall be equipped with a capacity control valve that shall reduce compressor capacity by unloading on bank of compressor cylinders when activated by the capacity selector switch (except 37 ton unit). All control circuitry shall be factory installed and connected. 3.0 EXECUTION 3.1 INSTALLATION OF CHILLER UNIT 3.1.1 General Install unit in accordance with manufacturer s installation instructions. Install unit plumb and level, firmly anchored in location indicated, and maintain manufacturer s recommended clearances. 3.1.2 Electrical Wiring Install and connect electrical devices furnished by manufacturer but not specified to be factory mounted. Furnish copy of manufacturer s electrical connection diagram submittal to the electrical contractor. 3.1.3 Piping Connections Install and connect devices furnished by the manufacturer but not specified to be factory mounted. Furnish a copy of manufacturer s piping connection diagram submittal to the piping contractor. 3.2 FIELD QUALITY CONTROL 3.2.1 Start up Start up air conditioning unit in accordance with manufacturer s start up instructions. Test controls and demonstrate compliance with requirements. Included in tech data SL-11700 (R11/97) 6 Guide Specifications