Ventilation Requirements

Similar documents
UK Experience with HTM-03 and Preventing Bio-contamination in Hospital OTs. Richard Knight CEng, MCIBSE, FIHEEM

HORNE 15 and 20 thermostatic mixing valve specification manual 2009

HEALTH TECHNICAL MEMORANDUM PART A. Specialist ventilation for healthcare premises, Part A: Design, installation, validation and verification

Company Portfolio. Issue 2

Quality Products AHU Repair, Refurbishment and Replacement

ELECTRICAL SAFETY IN HEALTHCARE FACITILIES

Washer-Disinfectors - Effectiveness and Quality Assurance. T. Miorini Institute for Applied Hygiene / ÖGSV

Getinge 9100E Cart Washer-Disinfector. Your safe, efficient and sustainable cleaning solution

Corporate. Laundry SOP. Document Control Summary

Theatre Classification and Air Particle Count Is that Surveillance?

ENDOSCOPE DECONTAMINATION : Where are we now!

Electrical Safety Policy

Newcastle Hospital NHS Foundation Trust Control of Infection Committee Water Coolers and Ice-Making Machines Policy

HVAC 101: Residential Typical system components & cleaning techniques

WHTM Welsh Health Technical Memorandum. Firecode Fire safety in the NHS. Part H: Reducing false alarms in healthcare premises

Fire Safety Awareness Workbook

DIGITAL HOT WATER SOLUTIONS

Integrated Ozone technology based solution For Hospital

DHS Design guidelines for hospitals and day procedure centres. Part E- Building Services and Environmental Design

Prescriptions for Critical Healthcare Cx. John D. Villani, P.E. Associate Grumman/Butkus Associates

Environmental Cleaning Tool Kit

Ultraclean ventilation. The shape of canopies to come.

Guidance on Environmental Requirements for Minor Surgery in General Practice

Guidance note: for the Verification of Ventilation Systems

Description of the property and water systems:

Ventilation in Healthcare Facilities Peter Hoffman, Public Health England A Webber Training Teleclass

Uniclass L725111:D4 EPIC H32. CI/SfB 4 (53.9) X. thermostatic tap specification manual OPTITHERM

MVHR - Practical experience of managing ventilation and air quality for resident well being

Circuit balancing: A key to improving HVAC system operation and control

INFECTION PREVENTION AND CONTROL ON LINEN AND LAUNDRY MANAGEMENT. ROSAFE E. PERALTA, RN, MAN Chief Nurse MARYMOUNT HOSPITAL

PROFESSIONAL KITCHEN CLEANING. New Kitchen Ventilation Systems supplied and fitted at competitive rates

FIRE SAFETY POLICY June 2014

Fire Safety Report & Audit

Mediclean Complanate Ultra Clean Ventilation

The Do's and Don ts in the Instrument Sterilisation Process

Guidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai

CPX RIGID PENDANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Chilled Water system

Risk Assessment and Control Measures for Household Hot Water Systems

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

Ventilation for Healthcare Facilities

Ventilation for Healthcare Facilities. Topics to be Covered

Interim Life Safety Assessments and Infection Prevention Assessments

In-line thermostatic mixing valves

CORRECT ENDOSCOPE REPROCESSING

The Latest Innovations in Hand Washing Technology

Healthcare Solutions. Water, faucets, and the fight against healthcare-associated infections (HAIs)

Accurately With HSE COP PT 1 5

DOMESTIC WATER RECORDS

FIRE SAFETY MANAGEMENT PROTOCOL FIRE DOORS & FIRE DOOR ASSEMBLIES

METHOD STATEMENT INFORMATION REQUIRED

Five London Hospital Fires: Report by Philip Gibbs, LFB. For internal training use only.

SAFETY ACTION NOTICE By arrangement with NSS Health Facilities Scotland

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

Theatre Control Panels

SAFETY ACTION NOTICE By arrangement with the NHSScotland Property and Environment Forum

HELENA PUBLIC SCHOOLS FRONT STREET LEARNING CENTER CLEANING OUTCOMES ASSESSMENT. May 2013

The Safety Valve Specialist TMV2. Thermostatic Mixing Valves. Engineered to a high specification, designed for safety and comfort

Solution: Problem: How can the air, and surfaces, be cleaned to lower the risk from the usual suspects? OR PACKAGE

DHF Introduction DHF 2

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer

The Plant Health Propagation Scheme (PHPS) is a voluntary scheme run by The Food and Environment Research Agency (Fera)

Glass Condensate Traps

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

AQUABLENDTM esqx ELECTRONIC TOUCH FREE POINT OF USE THERMOSTATIC MIXERS

Growing media and peat

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

Equipment Projector Screen Flipchart and Pens Cable Covers. Duration 1 hour

For Building Managers: outsourcing the maintenance of fire safety and security systems

Leaders in health, safety & environmental consultancy & training

Fire Engineering in High Rise 15 November 2013

The Cleaning Professional s Skills Suite

The Principles, The Process, and The Results:

Dangerous Assumptions

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

INTRODUCING CLINICAL WASTE SOLUTIONS LTD

Electrical Safety Policy and Management System

technical specification smoke venting systems

CONSIDERATIONS ON FACILITY AND ENGINEERING CONTROLS IN THE WAKE OF USP <800>

The Role of Air Handling Units in Combating the Spread of Infectious Disease

ASHRAE Standard 62 Ventilation Report Technical Assignment #1. Calvert Memorial Hospital Prince Frederick, MD

FP-PGN-14 Part of NTW(O)41 Fire Policy

Model LIND30-EVO. Model. Model LIND24-EVO LIND24-EVO-2PM

Professional Air Decontamination

FIRE SAFETY POLICY April 2011

A. Product Data: Include rated capacities, furnished specialties and accessories.

CONTRACTOR WHS HAZARD STANDARD LASER SAFETY EXTERNAL USE ONLY

Mechanical Systems Thesis Proposal: Calvert Memorial Hospital Prince Frederick, MD Holly Mawritz

Technical Report 1. ASHRAE Standards 62.1, 170, and 90.1 Evaluation. Morton Hospital Expansion

IAQ VENTILATORS. FRESH AIR REQUIREMENTS. Applications ASHRAE 62.1, 90.1 & School / university / day care.

Australasian Health Facility Guidelines. Part D - Infection Prevention and Control D Physical Environment

Hospital ventilation & infection prevention

Cost Savings. Waste disposal Occupational health Environmental impact Warehousing

Domestic fire sprinkler systems

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

Fire Safety Policy SH HS 06. Version: 4. Summary:

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

Washer disinfectors. > Small - Medium range. devoted to hygiene. For the Environmentally conscious

Transcription:

Ventilation Requirements Paul Wilkings C.Eng. MIMechE. FIHEEM. Principal Engineer(Mechanical)

Documentation Ventilation in Healthcare Premises Health Technical Memorandum 2025 Design considerations Management policy Operational management Validation and verification

Documentation HTM 2025 will shortly be replaced by HTM03 Ventilation Systems. According to the DOH, this document is now expected to go to the publishers in the next few weeks and be available before the end of 2007. **It is important that all HTM s HBN s etc. are accessed from the WHE website, (www.wales.nhs.uk/whe) as there could be changes within the Welsh Document from the standard DOH document.**

Definitions Ventilation Ventilation is a means of removing and replacing the air in a space. In its simplest form this may be achieved by opening windows and doors. Mechanical ventilation systems provide a more controllable method. Basic systems consist of a fan and a collection of distribution ductwork; more complex systems may include the ability to heat and filter the air passing through them. Ventilating equipment may be required in order to remove smells, dilute contaminants and ensure that a supply of fresh air enters a space. Air-conditioning Air-conditioning is the ability to heat, cool, humidify, dehumidify and filter air. This means that the climate within a space being supplied by an air conditioning plant can be maintained at a specific level regardless of changes in the outside air conditions or the activities within the space. Air-conditioning equipment may be required in order to provide comfort conditions within a space.

Ventilation Requirements The following departments will usually have specialist ventilation requirements, either for a single room or throughout a suite: a. an operating suite; b. a laser surgery unit; c. an intensive treatment unit; d. an infectious diseases isolation unit; e. a manufacturing pharmacy and cytotoxic drug units; f. a specialist X-ray and scanning unit; g. pathology; h. a mortuary and dissection suites; j. research laboratories and associated animal houses; k. sterilizing and disinfecting unit (SDU).

Ventilation Requirements of an SSD Health Building Note 13 Sterile Services Department, requires the following :- The Inspection and Packing Room (IAP Room) is a Class 8 clean-room as defined in BS EN ISO 14644. It should have a nominal 20 air changes per hour with a positive pressure differential of not less than 10 Pa between it and adjoining rooms. The Changing Room, should have a positive pressure differential of not less than 10Pa between it and the adjoining corridor. This equates to the IAP Room being at least 20Pa higher than the corridor, as access to the IAP Room is through the Changing Room.

Problems and Consequences Ventilation plant itself has not been shown to pose a high risk to health, but it does have the ability to transfer a hazard, originating from another source, to a large number of people, without them becoming immediately aware of it. Ventilation systems that can be shown to be inappropriate, inadequate or ineffective and that give rise to proven failures can result in a civil suit by the patient against the operators, or even prosecution by a Government body. (Barrow in Furness outbreak in 2002. The prosecution of Barrow-in-Furness Council and Gillian Beckingham. Seven people died and hundreds of others were infected by a legionella outbreak that resulted from the cancellation of a contract to ensure that necessary tests were carried out on an air conditioning unit.)

Responsibilities Management has a general responsibility to ensure that ventilation systems are operated at a standard suitable for the purpose for which they were installed. When new ventilation systems are accepted for use, full information, proving the designed mode of operation has been achieved, together with recommended maintenance procedures should be provided as part of the handover procedure.

Air Handling Unit plant room showing debris and water ponding on plant room floor. Any stagnant water is a breeding ground for legionella etc.

Instrument traceability equipment showing buildup of dirt and dust.

Build-up of flies inside Air Handling Unit

Incorrect choice of AHU equipment. Finned frost coil fitted instead of tubular type. Because pre filter is downstream of this coil fins have blocked up with dirt, debris and insects. Blocked coils reduce air flow to the spaces served, the result is that the air pressure regime is lost and hence the invisible barriers to infection are also lost.

Example of what can happen when things go really wrong! Photo shows a bird s nest inside an Air Handling Unit. This AHU was supplying an opthalmic theatre. It was shut down immediately, when we showed the Theatre Manager.

WHE recently undertook a survey of all the Operating Theatres in Wales, a few of the results showed the following;

Summary In conclusion there is a need to be aware of the ventilation/air conditioning requirements of individual departments they are not all the same. Air flows and pressure regimes for individual departments are extremely important, they set the invisible barriers to infection and are the first line of containment. Be aware of all new documentation; but access all documents from the WHE website, as there could be differences appertaining to the Welsh versions from the standard DOH documents. (www.wales.nhs.uk/whe)

One of the UK wide changes that we know is going to happen, is that split cassette type air conditioners and fan coil units are not going to be recommended for use in critical areas, such as ITU s, Cardiac Units, Renal Units etc. due to the high risk of infection that is associated with them. There have been a lot of these incorporated in recent designs. These may prove to be a problem in the future. While it is true that Trust Management is responsible for the correct day to day operation of equipment, it is also true that key project personnel such as project managers, planners, designers, contractors etc. are responsible for providing them with buildings and departments that are compliant to current documentation and legislation and proven to be fit for purpose, prior to occupation.

Thank You