Unvented Roof Assemblies for All Climates by Chris Schumacher

Similar documents
Attic ventilation options can be confusing to roofing contractors

2006 Building Science Press All rights of reproduction in any form reserved.

WHAT S UNDER YOUR ROOF?

Unvented Roof Summary Article

Measurement of Attic Temperatures and Cooling Energy Use in Vented and Sealed Attics in Las Vegas, Nevada

Insulating Unvented Attics With Spray Foam

2006 Building Science Press All rights of reproduction in any form reserved.

Overview of Presentation. Airflow Control: Why. Air Barriers and Energy

Air Distribution Fan and Outside Air Damper Recycling Control

Attic Condensation. Presented by: Joan Maisonneuve Technical Services

The Art of Building Science

Basic Building Science insights for Spray Foam, HVAC and Moisture

Why Are Attics Insulated With Open-Cell Spray Foam So Damp? Martin Holladay Editor, Green Building Advisor

Moisture-Safe Unvented Wood Roof Systems

Understanding Ventilation in Hot Humid Climates by Joseph Lstiburek

Insight. Venting Vapor. By Joseph W. Lstiburek, Ph.D., P.Eng., Fellow ASHRAE

Gambrel or Mansard Roofs and Ice damming

Energy Effcient Home Construction

Joe Konopacki 10/26/2016. Attic & Crawlspace Ventilation. What results from poor ventilation? Attic & Crawlspace Ventilation. Overview Why ventilate?

Moisture Movement. By Ben Gromicko

about your house Attic Venting, Attic Moisture, and Ice Dams Figure 1 Typical attic floor insulations

Natural Ventilation for Poultry

Ice Dams: Formations and Fixes

Water Intrusion, Vapor Transport and Vapor Diffusion in Buildings. Mark Scott P.E. LEED ap Wiss Janney Elstner Associates

Systems Engineering Approach to Development of Advanced Residential Buildings

IAQ & Moisture. Outline of Presentation. Fungi & Buildings IAQ. Fungi.

Insight. No Sweat. Condensation on ductwork and boots in hothumid and mixed-humid climates. By Joseph W. Lstiburek, Ph.D., P.Eng.

Insight. Cool Hand Luke Meets Attics. What we ve got here is failure to communicate By Joseph W. Lstiburek, Ph.D., P.Eng.

Airflow Control: Why. Air Barriers & Vapour Barriers. Air Barriers. Airflow Control. Remember. Dr John Straube University of Waterloo

Overview. Case Study 2008 Building America Prototype ICI Showcase House. Daytona Beach, Florida. Project Team: ICI Homes, Building Science Corporation

Builder s Technical Sessions. Attic Ventilation. Presented by: Rob Kaethler. Presented in Partnership with: Insert your logo here

Design Methodology and Economic Evaluation of Central-Fan-Integrated Supply Ventilation Systems

Properly designed economical engineering controls reduce chemical migration outside the spray area reduce re-occupancy time to less than 24 hours

Results of Advanced Systems Research: Supplemental Humidity Control Systems

Effect of Moisture on Building Systems!

Principles of Cold Insulation

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

Principles of Attic Ventilation. Acomprehensive guide toplanning The BalancedSystem for attic ventilation

Energy Conservation Measures For the Town of Lakeville. Locations Town Hall Fire Department Police Department Council on Aging

Ice Dam Symptoms and Solutions for a Cold-Climate Roof

Air Distribution Systems in Conditioned Spaces i.e. Ducts in Unvented Attics

Moisture and Buildings. Moisture Damage

Good News at Home Hankey & Brown Inspection Service June 2013

Ventilation for New Low-Rise Residential Buildings July 20, 2015

Ventilation Standards

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

WHY IS BUILDING SCIENCE IMPORTANT?

4. A 2 X4 knee wall, if insulated, should be to what R value? 5. The clearance between insulation and a furnace vent should be:

WHOLE-HOUSE VENTILATION SYSTEMS

Indoor Environmental Quality

Getting in the Zone with Zonal Pressure Diagnostics

BEST PRACTICE FOR THE LOCATION OF THE AIR AND THERMAL BOUNDARIES IN SMALL COMMERCIAL BUILDINGS

University of Illinois at Urbana-Champaign Small Homes Council-Building Research Council COUNCIL NOTES. ::s >

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

FIREPRO SoftSeal System

DUCT SYSTEMS CHAPTER 6

Essential Basics of Better Housing. Juergen Korn, P.Eng. Yukon Housing Corporation

Residential Air Leakage (Blower Door) Testing for Florida Code Compliance

Tech to Tech May 07 HRV s & ERV s

Underfloor Air Systems. How It s Different: Overhead vs. Underfloor Air Systems

Air Barriers & Vapour Barriers. Water Vapour Pressure. The 4 phases of Water. Water Vapour in Air. Water Vapour Pressure

Featuring The Weather Stopper Roof Protection Program!

Energy problems in small apartment buildings

Bert Phillips, P.Eng., MBA

This publication will describe the causes of excess moisture, how condensation occurs, and methods used to correct moisture problems.

Home Performance Science

Moisture Condensation

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

1 Exam Prep Energy Efficient Building Construction in Florida 8th Edition Tabs and Highlights

HUMIDITY CONTROL AND THE BUILDING THERMAL ENVELOPE IN NATATORIUMS. (What you don t see might hurt you)

Siding Installation Guide

B.S. 101 (building science)

Start today and start saving!

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness

AT-G-SENSE Gas Sensing System

Building Science Basics

raft-r-mate Attic Rafter Vent with optional air stop/insulation block A SIMPLE, ECONOMICAL WAY TO REDUCE ENERGY WASTE AND PREVENT ROOF DAMAGE.

Home Energy Assessment Report

Gardian W51. Approvals

Building America Special Research Project: Space Conditioning Systems for High Performance Homes

TABLE OF CONTENTS. Part I Administrative... 1

RP, GP, XP Pro Series Installation Instructions

Up on the Roof Fire Prevention BY David Laks, P. Eng., CFPS, ARM, RRC

Clean/Dry Rooms for Lithium Ion Battery Manufacturing

V ENTILATION V IEWS. News, opinions, ideas and technical advice from the ventilation specialists at Air Vent

Home Maintenance Schedule

ENERGY STAR V2.5 & 3 Designed to Qualify AIA Annual Convention

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

Low-Impact Remodeling

Please Read and Save These Instructions.

While most maintenance is seasonal, there are some things you should do on a frequent basis year-round:

PHASE II Analytical Assessment of Field Data for Sealed Attics in Florida Climate Zones 1 and 2 Predicting Moisture Buildup in Roof Sheathing

HYGROTHERMAL PERFORMANCE BENEFITS OF THE CELLULOSE FIBRE THERMAL INSULATION STRUCTURES

Installation Guide Maibec Regular Siding

DUCT SYSTEMS CHAPTER 6

Using a Pressure Pan To Diagnose Duct Leakage

Overview. Case Study Coastal Habitats Case Study * Project Team: Coastal Habitats Building Science Corporation

Home Cooling Fact Sheet. Stay Cool, Comfortable, and Cut Costs.

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

IN020 Rev F Page 1 of 8

Transcription:

2007 Building Science Press All rights of reproduction in any form reserved. building science.com 2007 Building Science Press All rights of reproduction in any form reserved. Building Science Digest 149 Unvented Roof Assemblies for All Climates 2007-07-24 by Chris Schumacher Abstract: This digest reviews unvented roof assemblies, such as conditioned attics and unvented cathedral ceilings, are becoming common in North American construction. These assemblies are created by eliminating ventilation openings and moving the thermal, moisture and air control boundaries to the plane of the roof deck. Unvented roof assemblies, such as conditioned attics and unvented cathedral ceilings, are becoming common in North American construction. It is estimated that over 100,000 have been constructed since 1995. These assemblies are created by eliminating ventilation openings and moving the thermal, moisture and air control boundaries to the plane of the roof deck. Why Unvented Roof Assemblies? Unvented roof assemblies address a number of issues that are important to homeowners, designers, builders and society:

2 Building Science Digest 149 Health & Comfort In many houses air leakage between the living space and the attic is not properly controlled. Air-conditioning equipment, exhaust fans, ductwork, attic access hatches, recessed lighting and even plumbing & electrical penetrations create holes that connect the living space to the attic. Pressures created by the mechanical equipment, as well as wind and temperature differences, cause air to move between these spaces leading to great energy waste and occupant discomfort. This uncontrolled movement of air can also carry moisture to cold surfaces where it can condense. In hot humid climates outdoor air can condense on the airconditioning equipment and ductwork typically located in attic spaces; in cold climates warm indoor air leaking into the attic can condense against the underside of the roof sheathing. Contaminants (including volatile organic compounds or VOCs) resulting from premature building material degradation due to the uncontrolled movement of moisture laden air can migrate from the attic into the living space. In unvented roof assemblies the thermal, moisture and air control boundaries are moved to the roof deck so that the attic space is at the same condition as the living space and air movement between the two does not contribute to energy waste, occupant discomfort or contaminant problems. Energy When air-conditioning equipment and ductwork are located in conventional ventilated attics, they must be insulated and air sealed. This is often difficult to accomplish. Even when air sealing is done well, there remain large energy-wasting temperature differences (up to 150 F or 65 C) between the air in the ductwork and the air in the attic for hundreds to thousands of hours a year. It is not practical to sufficiently insulate the ductwork and equipment against this. If the thermal, moisture and air control boundaries are moved to the roof deck to create an unvented conditioned roof assembly, the load on the mechanical equipment is significantly reduced and ductwork leakage will occur to or from the conditioned living space. Durability Openings in the soffits, gables, mushroom and ridge vents allow more than just air to enter the attic. In cold northern climates snow can be blown in through these openings, accumulating, melting and causing damage to the ceiling or creating the potential premature structural failure or mold growth inside the roof assembly. In coastal climates wind driven rain can be blown in through these openings with similar results. In areas subject to wildfires, burning embers can be blown in through these openings, potentially starting roof fires.

Unvented Roof Assemblies for All Climates Unvented roof assemblies are not prone to these problems because the ventilation openings have been eliminated. Value Many homeowners see value in finished attics that can provide more living space and conditioned storage space. Additionally, designers are using increasingly complicated roof geometries and providing spaces with high cathedral ceilings. These create problems for conventional ventilated roof assemblies because the geometry makes it impossible to ensure airtightness at the ceiling plane. Furthermore, ventilation spaces become small and complex, making it difficult to ensure adequate flow rates or distribution of ventilation air inside the ventilated assemblies. The ventilation space can be eliminated and the construction greatly simplified by using an unvented roof assembly. Why use Closed-Cell Spray Polyurethane Foam (ccspf)? Closed-cell spray polyurethane foam can be used to create an unvented roof assembly that works in all climate zones. The design approach is the same for all climate zones. How ccspf Unvented Roofs Work There are currently two types of spray polyurethane foam (SPF) insulation used in North American residential construction: ccspf or closed-cell medium-density spray foam ( 2 pound or 2 pounds per cubic foot) and ocspf or open-cell low-density spray foam ( half pound or 0.5 pcf). When installed properly, both adhere to most construction surfaces and expand to fill voids and create an air seal. Closed-cell spray foam made with EPA-approved HFC blowing agents like, Honeywell Enovate 245fa, has a higher thermal resistance (e.g. is a better insulation) and lower vapor permeance than open-cell spray foam. Closed-cell spray foam acts as an air barrier (at 1 in. or 25 mm minimum thickness) and vapor retarder (at 2 in. or 50 mm minimum thickness*) and therefore does not need an additional vapor retarder in cold climates.)

4 Building Science Digest 149 Unvented roof assemblies with ccspf work well in all climate zones and serve several important functions: Controls Airflow ccspf is air impermeable, adheres well to almost all construction surfaces and expands to fill voids creating an air seal and eliminating air leakage. In cold climates it prevents warm, humid indoor air from reaching the back (underside) of roof sheathing where it can condense. In warm climates it prevents humid outside air that enters the roof due to natural and/or controlled ventilation from reaching the back of the roof sheathing, which can be cooled below the air temperature by night sky radiation (i.e. the effect that causes dew). Control Heat Flow Closed-cell spray foam has exceptional thermal performance relative to other insulations (i.e. the highest R-value per inch.) ccspf can be used to create a very compact roof assembly that meets or exceeds the code required thermal performance.

Unvented Roof Assemblies for All Climates Control Vapor Diffusion Closed-cell spray foam acts as a throttle to control the rate of vapor diffusion. The foam insulation resists the diffusion of water vapor so that the amount of water vapor is reduced as it moves through the thickness of the foam. By the time the water vapor reaches the back of the roof sheathing, there is not enough left to cause condensation problems. In cold climates the ccspf provides the first condensing plane. The ccspf should be installed directly to the face (i.e. back) of the roof sheathing in a layer thick enough to prevent condensation from forming on the inside face of the foam. In hot climates up to 5 in.* (125 mm) of ccspf can also be used. In this application the assembly can still dry to the inside during the daytime when roof temperatures are high (120-190 F or 50-90 C), the vapor pressure gradients are very large (5-35 kpa) and the foam is a vapor retarder and not a vapor barrier.

6 Building Science Digest 149 Controls Rain Leakage Closed-cell spray foam has negligible water permeability, minimal water absorption, and excellent adhesion allowing it to act as a secondary rainwater barrier to limit damage when primary roof assembly rainwater control membranes leak. Rainwater migration is severely limited due to the low water transmission and high adhesion ( waterproofing ) characteristics of the foam and damage is limited to the area immediately adjacent the hole in the primary rainwater control membrane. This tends to contain the damage, making it easier to identify the source and preventing it from spreading throughout the assembly and to interior finishes which can be costly to repair. What You Should Do Closed-cell medium-density spray polyurethane foam (ccspf) insulation can be used to create an unvented roof assembly for any climate zone. Be sure to: 1. Control rain In any roof assembly an underlayment (e.g. minimum of felt paper) should be installed as the primary water barrier under the roofing. The joints should be lapped properly and the underlayment must be integrated with flashings to direct water out and off of the roof assembly. Any roofing material can be used on an unvented roof assembly with ccspf. If wood shingles or shakes are used a layer of drainage mat (e.g. minimum _ in. or 6 mm vented airspace) should be installed between the roofing and the underlayment. 2. Control airflow Install at least 1 in. (25 mm) of ccspf against the underside of the roof deck to prevent air leakage through the roof assembly and to prevent moist indoor air from reaching the inside of the roof sheathing where it can condense. 3. Control heat flow Install additional insulation to meet the minimum code requirements or the goals of the project. This can be done by increasing the thickness of the ccspf installed. This can also be done using other insulations such as blown cellulose, BIBs, mineral wool batt or glass batt insulation in combination with ccspf. 4. Control vapor diffusion The inherent characteristics of the ccspf allow it to be used in all climate zones without requiring the installation of any additional vapor diffusion control (i.e. no additional vapor retarder layer or coating is required with ccspf installed to thicknesses greater than about 2 in. or 50mm*). 5. Control fire The indoor face of the unvented roof assembly may need to be finished with appropriate materials (such as thermal barriers and ignition barriers) to meet the fire requirements of local codes. In many residential applications no additional protection layer is required. Local codes should be consulted.

Unvented Roof Assemblies for All Climates * Consult the specific manufacturer s application instructions and technical data sheet for maximum allowable thickness and minimum thickness required to qualify as a suitable vapor retarder. Christopher Schumacher is a principal of Building Science Consulting. Chris is recognized as an expert in the field of building monitoring and building systems and enclosure testing. More information about Christopher Schumacher can be found at www.buildingscienceconsulting.com/about Direct all correspondence to: Christopher Schumacher, Building Science Consulting, 70 Main Street, Westford, MA 01886 Limits of Liability and Disclaimer of Warranty: Building Science Digests are information articles intended for professionals. The author and the publisher of this article have used their best efforts to provide accurate and authoritative information in regard to the subject matter covered. The author and publisher make no warranty of any kind, expressed or implied, with regard to the information contained in this article. The information presented in this article must be used with care by professionals who understand the implications of what they are doing. If professional advice or other expert assistance is required, the services of a competent professional shall be sought. The author and publisher shall not be liable in the event of incidental or consequential damages in connection with, or arising from, the use of the information contained within this Building Science Digest.