Downdraft Raised Vent

Similar documents
Integrated Ventilation System

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

Installation Instructions Remote Blowers

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

Installation Instructions Preference Wall Mount Range Hood

ERV3015, ERV3615. Renaissance 30, 36 Wide, High Extension Slim Raised Vents. Top cap with vent down

ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER, PRV30, PRV36, PRV48

Installation Instructions Built-In Wine Coolers, Beverage Centers

Installation Instructions Induction Cooktop

Installation Instructions Outdoor Refrigerator

Integrated Hood Liner

Integrated Hood Liner

Installation Instructions. Discovery Wall Oven. EO, MOH and MOV Series. Part No Rev. M

Installation Instructions Preference. Cooktop. Models: SGM304, SGM365, SGM466. Part No Rev. K

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Modernist Warming Drawer

Installation Instructions. Warming Drawer

Installation Instructions Distinctive. Series Cooktop. Models DCT305, DCT365. Part No Rev. L

Installation Instructions. Warming Drawer

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

Installation Instructions. Discovery Wall Oven. Preliminary - For Review Only No Scheduled Release Date. For use with models EO, MO and PO

Installation Instructions Epicure. Cooktop. Models: ESG366, ESG486. Part No Rev. K

Installation Instructions Wall Ovens

Installation Instructions

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365

Cooktop Chimney Ventilation Hoods

Installation Instructions

Installation Instructions. Warming Drawer. Models: EWD24, EWD27, EWD30, EWD36, IWD24, IWD27, IWD30, MWDV27, MWDH27, MWDV30, MWDH30 PWD27, PWD30

Downdraft Ventilation

Ins t a l l a t i o n In s t r u c t i o n s Wa r m i n g Ov e n For use with models: EW, EWO MW, MWO PW, PWO IWO, IOWO

Installation Instructions. Warming Drawer. Preliminary - For Review Only

Installation Instructions. Discovery Wall Oven. Preliminary - For Review Only No Scheduled Release Date. For use with models: EO, MO and PO

Installation Instructions. Discovery Gas Cooktop. Models DYCT304G, DYCT365G. Part No Rev. A

Installation Instructions Dual Fuel Ranges

Installation Instructions Millennia Cooktops

CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

READ AND SAVE THESE INSTRUCTIONS

Multi-Function Cooktop

Installation Instructions Renaissance Integrated Hood Liner

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

Use and Care Manual Downdraft Raised Vent

GAS COOKTOP INSTALLATION INSTRUCTIONS


Use and Care Manual Downdraft Raised Vent

Distinctive Series Cooktop

Installation Instructions Renaissance Built-in Dishwasher

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Distinctive TM Electric Cooktop

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

user manual Model #: BLZ-WVH-42

Use, Care, and Installation Guide

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

Operating and Installation Instructions

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

INSTALLATION GUIDE Dual Fuel Ranges

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

READ AND SAVE THESE INSTRUCTIONS Page 1

user manual Model #: BLZ-HOOD

READ AND SAVE THESE INSTRUCTIONS

Installation. Professional Built-in Hoods

Installation Instructions

Installation Instructions Renaissance. Rangetop. Models: EG366, EG486

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind Professional Series Liners

Installation Instructions

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed

DESIGN CLASS FUNCTION

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Installation Electric Dryers Instructions 01

Installation Guide. 15 W. Undercounter/Freestanding Nugget Ice Machine U L. Viking Range, LLC. 111 Front Street

user manual Model #: BLZ-WVH-42

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

Installation Instructions

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Guide. 15 W./24 W. Undercounter Refrigeration

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Installation Instructions

Installation Guide. 15 W./24 W. Undercounter Refrigeration U L. Viking Range Corporation. 111 Front Street. Greenwood, Mississippi USA

Installation Instructions

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Installation instructions for the T 9820 Gas Dryer

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Installation. 15 W. Undercounter/Freestanding Ice Machine FGIM515 / CFGIM515 FPIM515 / CFPIM515

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION GUIDE Induction Cooktops

INSTALLATION INSTRUCTIONS CARE AND USE MANUAL FOR: ISLAND RANGE HOODS Models covered by this instructions: SU900, SUT900, SUE900, SU901, SU902, SU903

IVI WARNINGS: Must be followed carefully to avoid personal injury. [VL

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Transcription:

Downdraft Raised Vent Model ERV3615 Installation Instructions Use these downdraft raised vents only with approved Dacor appliances. See the installation instructions for the particular appliance model being installed to determine suitability. Part No. 107000 Rev. A

Important Safety Instructions... 1 Important Information About Safety Instructions... 1 Safety Symbols and Labels... 1 General Safety Precautions... 2 Product Specifications... 3 Product Dimensions... 3 Installation Specifications... 4 Electrical Specifications... 4 Planning the Installation... 4 Planning the Duct Work... 6 Important: Table of Contents Before You Begin... Installation Instructions... 8 Installation Preparation... 8 Installation... 8 Verifying Proper Operation... 12 Installation Checklist... 12 Wiring Diagram... 13 Installer: In the interest of safety and to minimize problems, read these installation instructions completely and carefully before you begin the installation process. Leave these installation instructions with the customer. Customer: Keep these installation instructions for future reference and the local electrical inspector s use. If You Need Help... Customer Service Information If you have questions or problems with installation, contact your Dacor dealer or the Dacor Customer Service Team. For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line. Whenever you call, have the model and serial number of the appliance ready. The model and serial number are printed on the product data label on the front of the unit. The product data label also specifies the power supply requirements. Dacor Customer Service Phone: (800) 793-0093 (U.S.A. and Canada) Monday - Friday 6:00 a.m. to 5:00 p.m. Pacific Time Web site: www.dacor.com Dacor Distinctive Service (for repairs under warranty only) Phone: (877) 337-3226 (U.S.A. and Canada) Monday - Friday 6:00 a.m. to 4:00 p.m. Pacific Time Tested in accordance with the latest edition of UL 507 and CSA C22.2 standards on approved Dacor appliances. All specifications subject to change without notice. Dacor assumes no liability for changes to specifications. 2011 Dacor, all rights reserved.

Important Information About Safety Instructions Important Safety Instructions The Important Safety Instructions and s in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. Always contact the Dacor Customer Service Team about problems and conditions that you don t understand. See Customer Service Information. Safety Symbols and Labels DANGER Immediate hazards that WILL result in severe personal injury or death. Hazards or unsafe practices that COULD result in severe personal injury or death. caution Hazards or unsafe practices that COULD result in minor personal injury or property damage. DANGER IMPORTANT: Do not store or use combustible, flammable or explosive vapors and liquids (such as gasoline) inside or in the vicinity of this or any other appliance. Also keep items that could explode, such as aerosol cans, away from the cooking appliance. Do not store flammable or explosive materials in adjacent cabinets or areas. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. b) Sufficient air is needed for proper combustion and exhausting of gases through the flue(chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. d) Ducted fans must always be vented to the outdoors. READ AND SAVE THESE INSTRUCTIONS 1

General Safety Precautions Important Safety Instructions To reduce the risk of fire, electric shock, serious injury or death when using your appliance, follow basic safety precautions, including the following: Warning Do not install or operate a damaged appliance. If you receive a damaged appliance, contact your dealer or builder. Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Use this raised vent only for its intended purpose as outlined in the use and care manual. This appliance is not intended for commercial use. The customer should not install, repair or replace any part of this unit unless specifically recommended in the literature accompanying it. A qualified service technician should perform all other service. Contact the Dacor Customer Service Team for examination, repair or adjustment. Keep all packaging materials away from children. Plastic bags can cause suffocation. For proper operation, this unit must be installed with a remote or in-line blower. Use only one of the models specified. Only one blower shall be installed. Install or locate this appliance only in accordance with these installation instructions, the Dacor cooking appliance installation instructions and the remote or in-line blower installation instructions. Improper installation, adjustment, alteration, service or maintenance can cause serious personal injury or property damage. Before installing or servicing the raised vent, disconnect the power plug from the electrical outlet. The installer must show the customer the location of the electrical outlet so that the customer knows where and how to disconnect power. Read the use and care manual completely before operating this appliance. Do not tamper with the controls. Never allow the filters or vent openings to become blocked or clogged. Do not allow foreign objects, such as cigarettes or napkins, to be sucked into the vent holes. Clean the filters and all grease-laden surfaces often to prevent grease fires and maintain performance. Clean this appliance only as specified in the use and care manual. Do not leave children or pets alone or unattended in the area around the cooking appliance when it is in use. Never allow children to sit or stand on an appliance. Do not let children play with a cooking appliance or the raised vent. Do not store items of interest to children above or around the appliance. This appliance is equipped with a three prong grounding plug for your protection against possible electric shock hazards. It must be plugged into a dedicated, grounded electrical outlet. Where a standard two prong electrical outlet is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a dedicated, properly grounded three prong electrical outlet. Do not under any circumstances: Cut or remove the third (ground) prong from the power cord. Use an adapter plug. Use an extension cord. Use a power cord that is frayed or damaged. Use of a ground fault interrupter (GFI) is not recommended. Three prong grounding plug Grounding type electrical outlet 2

Product Dimensions Product Specifications 5/16 (8 mm) thick stiffener across back 2 3/16 (5.6 cm) 2 1/8 (5.4 cm) Top cap with vent down Tolerances: ±1/16" (±1.6 mm) unless otherwise stated A - Top Cap Width B - Chassis Width 36 (91.4 cm) 33 3/8" (84.8 cm) 3 (7.6 cm) 1 15/16 (4.9 cm) 3/16 (5 mm) 9/16 (1.4 cm) 3/8 (1.0 cm) 2 1/8 (5.4 cm) Top cap - side view 2 9/16 (6.5 cm) A Vent shown in raised position 15" (38.1 cm) 20 (50.8 cm) 3 3/4 (9.5 cm) 1 1/8 (2.9 cm) 30 1/4 (76.8 cm) to 37 1/4 (94.6 cm) 30" (76.2 cm) B 6 (15.2 cm) Motor cover Front of unit Product data label 28" 3 prong grounded power cord See page 6 for exhaust locations and dimensions. * Maximum height of raised vent must not exceed maximum specified counter height for cooking appliance. See installation instructions for cooking appliance. Adjustable anchor legs 3

Electrical Specifications Installation Specifications The electric outlet for the raised vent should be installed only by a licensed electrician. The raised vent is supplied with a 28 (71 cm) power cord with a three prong plug. Plug it directly into a three prong electrical outlet meeting the requirements below. Do not use an extension cord. The correct voltage, frequency and amperage must be supplied as specified below. The circuit must be protected by a properly sized circuit breaker or time-delay fuse. Electrical Supply Requirements A three prong electrical outlet connected to a 120 Vac, 60 Hz, 15 Amp. grounded, dedicated, single phase circuit is required. The above specifications are for reference only. If the power supply requirements shown above do not agree with those listed on the product data label, use the ratings on the label. The customer must supply 3 conductor wiring/conduit with minimum current carrying capacity of 8 Amps. to supply power to the remote or in-line blower from the raised vent. See General System Layout and Planning the Duct Work for further details. It is the owner s responsibility to ensure that electrical outlet is installed by a licensed electrician. The electrical installation must comply with the latest revision of the National Electric Code ANSI/NFPA 70* (latest revision) and local codes and ordinances. *A copy of this standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101 Locate the electrical outlet in an accessible location, so that the power plug can be disconnected for service without removing the cooking appliance or raised vent from the cabinet. Planning the Installation General System Layout The vent system consists of the raised vent itself and a single Dacor approved remote or in-line blower (see page 6). Failure to install an approved remote or in-line blower or proper duct work will result in a back draft and/or the insufficient venting of smoke and fumes. To reduce the risk of personal injury caused by reaching over a hot appliance, cabinet storage space located directly above the cooking appliance should be avoided. Follow the instructions and diagrams for minimum safe clearances and installation location in these instructions, the appliance installation instructions and the remote or in-line blower installation instructions. Failure to do so may result in a fire or safety hazard. Install the raised vent and cooking appliance so that they can be removed if service is required. Refer to the cooking appliance installation instructions for the minimum cutout dimensions specific to the particular raised vent model being installed. Plan the installation so that all minimum dimensions are met or exceeded. All contact surfaces between the raised vent and any cabinets or walls must be solid and at right angles. The raised vent exhaust may be configured to vent through the back, the bottom or through one of the sides. Allow room for the exhaust duct coming out of the unit. See Planning the Duct Work for further details. The maximum allowable duct run must be taken into consideration when determining the layout. See Planning the Duct Work for further details. The raised vent is equipped with adjustable anchor legs to accommodate various cabinet heights. Wire the remote or in-line blower to turn on when the raised vent is turned on. Run the blower wiring/conduit parallel to the duct work, connecting it to the raised vent on one end and the blower on the other. There are 7/8 access holes in the bottom and side of the raised vent for connecting the conduit/strain relief. Front of unit Blower wiring access hole in bottom Electrical Access Hole Locations Blower wiring access hole in side 4

Installation Specifications Backsplash Countertop overhang Vertical non-combustible surface rear wall Notches required for some rasied vent installations, see cooktop installation instructions See the cooktop installation instructions for exact countertop and cabinet dimensions Flush with back side of cabinet front Cooktop Cabinet/Countertop Cutout - Top View REMP series remote blower 3 ¼ X 10 to round transition and 45 adjustable elbow Wall board Duct work between raised vent and remote blower Backsplash Cooktop Cabinet back Outside wall Raised vent Cooktop Raised vent Raised vent configured for rear exhaust Raised vent configured for bottom exhaust 3 ¼ X 10 to round transition Floor Wall cap on outside wall Floor Wiring/conduit from raised vent to remote blower Wiring/conduit from raised vent to in-line blower Duct work Duct work ILHSF series in-line blower Example of Layout with Cooktop and Rear Exhaust Example of Layout with Cooktop and Bottom Exhaust 5

Planning the Duct Work Installation Specifications To reduce the risk of fire and to properly exhaust air, be sure to duct air outside the house or building. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages. Tape all duct joints securely to prevent combustion by-products, smoke or odors from entering the home. Doing so will also improve system efficiency. TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK. DO NOT install more than one blower to increase the length of the duct run. Even small differences between blower air flow rates can greatly reduce the air draw by the raised vent. You must install one of the Dacor remote or in-line blower models listed below for the raised vent to operate properly. See the blower installation instructions for directions. Only one blower shall be installed. APPROVED DACOR BLOWERS FOR USE WITH ERV3615 Model Number REMP3 REMP16 ILHSF8 ILHSF10 Rating* 600 CFM 1000 CFM 600 CFM 1100 CFM * Nominal rating at zero inches static pressure. See blower installation instructions for actual ratings. The raised vent can be configured to exhaust through the back, the bottom or either side by removing the appropriate exhaust knock out shown below. When connecting the duct work to the back of the unit, the customer must supply a 3 ¼ X 10 rectangular transition to make the connection. For side and bottom exhaust connections, use the supplied ATD2 transition to connect the duct work to the unit. It transitions between the 1 ⅝ X 16 exhaust outlet on the unit and a 3 ¼ X 10 rectangular duct connection. On bottom exhaust installations cut a hole in the floor to allow the transition and/or duct work to pass through the floor (see page 8). 5" (12.7 cm) 2 X 16, connects to side or bottom exhaust on raised vent 1 1/8 (2.9 cm) C L 6 1/2 (16.5 cm) Rear Exhaust Knock Out (3 ¼ X 10 ) Vertical center line of rear exhaust knock out lines up with vertical center line of chassis Bottom Exhaust Knock Out (1 ⅝ X 16 ) The vertical center line of bottom knock out is offset 3 Side Exhaust Knock Outs (1 ⅝ X 16 ) Front of unit C L Motor cover 3 C L 26" (66.0 cm) 1" (2.5 cm) 3 ¼ X 10 to duct work ADT2 Transition All duct work materials (including screws and duct tape) must be purchased separately by the customer. When planning new duct work, always look for the shortest, most direct route to the outside. See page 5 for examples. You can increase the duct size over the duct run if desired. To prevent a back draft, never decrease the duct size over the run. Do not rely on duct tape alone to seal duct joints. Fasten all connections with sheet metal screws and tape all joints with certified silver tape or duct tape. Use sheet metal screws as required to support the duct weight. To prevent back-drafts, a damper at the duct outlet may also be required. 6

Installation Specifications On side exhaust installations, allow five inches of space on the side for the ADT2 exhaust transition plus additional space for the duct attached to it (X). Make sure duct work does not interfere with floor joists or wall studs. With concrete slab construction, box-in the duct work and blower wiring to prevent collapsing or other damage when the wet concrete is poured. Cross-drafts or air currents from adjacent open windows or doors, heating/air conditioning outlets, ceiling fans and recessed ceiling lights reduce vent efficiency. ATD2 5 X Duct Work Design Tips Wherever possible, reduce the number of transitions and turns to as few sharp angles as possible. Two staggered 45 angles are better than one 90. Keep turns as far away from the hood exhaust as possible, with as much space between each bend as possible. For best performance, use round duct instead of rectangular when possible, especially when elbows are required. If multiple elbows are used, try to keep a minimum of 24 of straight duct between them. Avoid S or back to back configurations of adjacent elbows. Do not use flexible metal duct. Calculating the Maximum Duct Run Length Do not use duct work that is smaller in cross-sectional area than the required duct sizes in the table to the right. For best performance, keep the duct run as short as possible and never exceed the maximums stated at the right. The maximum straight duct length for the raised vent system depends on the model of remote or in-line blower used with the vent system and the number of elbows and transitions used. The Equivalent Number of Feet for each elbow and transition (see table) must be subtracted from the maximum straight length to compensate for wind resistance. To determine the maximum allowable length of the duct work, subtract all of the equivalent lengths of the elbows and transitions listed at the right from the Blower Maximum Duct Straight Length. For example, for a raised vent system using 3 ¼ X 10 rectangular duct, two (2) 3 ¼ X 10 90 elbows, a 3 ¼ X 10 rectangular to 10 round transition, and a REMP16 remote blower: From the Blower Maximum Duct Straight Length table below, the maximum length without transitions and elbows is 60 feet. The equivalent length of each 90 elbow is 15 feet. The equivalent length of 45 elbow is 2 feet. The equivalent length of the transition is 4 feet. The total equivalent length of the above components is: 15 feet + 15 feet + 4 feet + 2 feet = 36 feet. The maximum amount of straight duct that can be used with a REMP16 and the above components is: 60 feet - 34 feet = 24 feet. 45 elbow 8 Inch 45 elbow 10 Inch 90 elbow 8 Inch 90 elbow 10 Inch 90 3 ¼ X 10 to 8 round transition Equivalent Number of Feet - Duct Elbows and Transitions 3 feet 2 feet 7 feet 5 feet 25 feet 3 ¼ X 10 45 elbow 3 ¼ X 10 90 elbow 3 ¼ X 10 90 flat elbow 3 ¼ X 10 to 8 round transition 3 ¼ X 10 to 10 round transition 7 feet 15 feet 20 feet 4 feet 4 feet Roof cap * Wall cap * * The equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVAC specialist. Duct Size Blower Maximum Duct Straight Length Used REMP3 Remote Blower REMP16 Remote Blower ILHSF8 In-line Blower ILHSF10 In-line Blower 8 Inch 50 feet (15.2 meters) 60 feet (18.3 meters) 50 feet (15.2 meters) 60 feet (18.3 meters) 10 Inch 40 feet (12.2 meters) 70 feet (21.3 meters) 40 feet (12.2 meters) 70 feet (21.3 meters) 3 ¼ X 10 40 feet (12.2 meters) 60 feet (18.3 meters) 40 feet (12.2 meters) 60 feet (18.3 meters) 7

Installation Preparation Verify Package Contents Product literature Anchoring legs 2 wood screws, #14 x 2 ½ (PN 83047) 3 wire nuts ADT2 duct transition 2 sheet metal screws, #10 x ½ (PN 83022) 2 keps nuts, ¼-20 (PN 83049) 2 flat washers, ¼-20 (PN 83203) Insulation foam Installation Installation Instructions 2. Cut and remove the foil material inside the knock-out hole. If you fail to remove the foil, the vent will not work. 3. If the unit will vent through the bottom or side: Attach the supplied ATD2 transition to exhaust location with the provided sheet metal screws. ADT2 side installation If the electrical service (electrical outlet) does not meet the Electrical Specifications on page 4, do not proceed with the installation. Call a licensed electrician and have an electrical outlet installed that meets the specifications. Install the vent only in a vertical orientation. Do not mount the vent on a slant or angle. Do not enlarge or modify the exhaust knock outs or cut an exhaust hole in a location on the chassis other than those shown. Doing so may cause an increase in noise and decrease performance. NOTE: The raised vent installs in the back of the cutout, separate from the cooking appliance. Install the raised vent before installing the cooking appliance. Installing the Raised Vent 1. Remove the appropriate side, back or bottom exhaust knockout, depending on the desired exhaust configuration, from the raised vent chassis by cutting the metal cross overs and removing the insert. Back of unit ADT2 bottom installation Attach sealing foam ADT2 Transition Installation For bottom installations cut a hole in the cabinet floor to allow the exhaust transition and/or the duct to pass through the floor. Top of vent resting on countertop Cut hole in floor to allow duct to pass through on bottom venting installations Side knock-out Side knock-out Floor Rear knock-out with metal cross overs shown 4. If the unit will exhaust air from the back, attach a 3 ¼ X 10 duct to the vent hole created by removing the knock-out on the back of the unit. Bottom knock-out Vent Knock-out Locations - Rear View 8

5. Gently slide the vent into the rear of the countertop cutout with the electrical access panel toward the front. Installation Instructions Top of vent resting on countertop Installing the Blower and Ducts 1. Install the remote or in-line blower according to the blower installation instructions. 2. Install the duct work according to the Installation Specifications section. Use sheet metal screws and duct tape to connect and seal all of the pieces. Support the duct weight as necessary to ensure sealed joints. Anchor leg Front of raised vent REMP series remote blower Attach to floor with wood screws Put nuts/ washers on studs Electrical access panel 3 ¼ X 10 to round transition and 45 adjustable elbow Floor 6. Loosely attach the anchoring legs to the studs on the left and right sides of the raised vent using the provided keps nuts and washers. 7. Adjust the anchoring leg height so that the end caps are gently resting on the counter, then tighten the hex nuts. 8. Secure the anchoring legs to the cabinet floor with the provided wood screws. Wall board Cooktop Duct work between raised vent and remote blower Backsplash Raised vent Raised vent configured for rear exhaust Wiring/conduit from raised vent to remote blower Floor Example of Installation with Rear Exhaust (Side View) 9

Installation Instructions Electrical Installation ELECTRIC SHOCK HAZARD - Do not connect the raised vent power plug to the electrical outlet until installation is complete. Failure to complete electrical connections properly may result in an electric shock hazard or a damaged or non-functional system. Follow the wiring diagrams carefully to ensure a proper installation. Do not change the factory wired terminal connections inside the electrical access panel for the raised vent or the blower. To avoid an electric shock hazard and to prevent damage route all wiring away from hot surfaces. 1. Run the wiring/conduit line used to supply power from the raised vent to the blower parallel to the duct work. 2. Make sure the raised vent power plug is disconnected from the electrical outlet. 3. Remove the cover from the raised vent electrical access panel. 4. Connect the wiring/conduit to the blower according to the wiring diagrams on this page, the facing page and local codes and ordinances. Make sure all terminal connections, including the factory wired connections, are tight. 5. Replace the electrical access panel. Match wire colors to terminals as shown. Wires to power plug. Pre-wired at factory. Do not modify. BLACK WHITE Blower Output Electrical access panel Ground Power Input GREEN Attach ground wire as shown To power wiring/conduit. Connect other end of wires to blower terminal block. Raised Vent Front View Raised Vent Electrical Access Panel 10

Installation Instructions REMP16 remote blower Connect wires/conduit according to remote blower installation instructions Raised vent Cooktop See Raised Vent Electrical Access Panel on facing page Floor Wiring/conduit from raised vent to remote blower Example of Installation with Bottom Exhaust (Side View) Cooking Appliance Installation Install the cooking appliance according to its installation instructions. 11

Verifying Proper Operation Read the raised vent use and care manual completely before operation. Install all of the front filters prior to operating the raised vent. Refer to the use and care manual for filter installation instructions. caution To prevent damage to the raised vent power cord, route it away from the surfaces of the cooking appliance before connecting it. 1. Make sure the power switch on the top of the raised vent is in the up position. 2. Plug the raised vent power plug into the electrical outlet. 3. Press the power switch once to raise the vent to its operating position. 4. Once in the up position the vent should begin to draw air. Turn the variable speed control switch in both directions to verify that the system is operating correctly. 5. Press the top cap up/down switch once to lower the vent. 6. Make sure that the top cap on the raised vent intake does not catch on the back edge of the cooking appliance when the intake is lowered. If interference occurs, adjust the position of the cooking appliance. Failure to eliminate any interference may result in permanent damage to the vent. If the raised vent is not operational after installation: Make sure that power is being supplied to the unit. Make sure that power is being supplied to the blower from the raised vent. If the vent will not raise properly or makes a scraping sound check for obstructions interfering with the raising of the unit. If the raised vent still does not function after performing the above checks, do not attempt to repair it yourself. Contact Dacor Distinctive Service at (877) 337-3226. Be sure to have all model and serial numbers from the product data labels for the raised vent and the blower available when you call. Dacor is not responsible for the cost of correcting problems caused by a faulty installation. Installation Instructions Installation Checklist Are the anchor legs extended down to make contact with the floor and tightened into place? Are the anchor legs fastened to the floor? Is the unit level? Is the duct work completely installed? Are all joints attached with sheet metal screws and wrapped with duct tape? Are both ends of the remote or in-line blower power cable connected (to the raised vent and to the blower itself?) Are the vent filters installed according to the use and care manual instructions? Is the power cord routed away from the hot surfaces of the cooking appliance. Is the unit connected to an electrical outlet that meets the electrical specifications in these instructions? Has proper operation been verified? Has the warranty been activated on-line or the warranty card been filled out completely and mailed? 12

Wiring Diagram DOWN LIMIT SWITCH COM UP LIMIT SWITCH COM SNORKEL SWITCH NO NC NC NO RED YEL COM NO RED BLUE NC BLK CHASSIS GROUND STUD BLUE WHT WHT YEL WHT RELAY REMOTE POT N L COM NO L2 N2 L1 N1 GND GND ORNG BLK SPEED CONTROL RED BLOWER OUTPUT POWER INPUT GROUND ORNG BLK 13

Dacor 600 Anton Blvd. Suite 1000 Costa Mesa, CA 92626 Phone: (800) 793-0093 Fax: (626) 403-3130 www.dacor.com