NASA Plans for Dosimetry in Support of Manned Spaceflight

Similar documents
Update on the NASA Plans for Dosimetry in Support of Manned Spaceflight

Heavy Ion Beam Characteristics of ICCHIBAN 7 and 8 Experiments and Brief Summary of the ICCHIBAN Experiments

Radiation Environment on ISS in April 2013 According the Data from Liulin-5 Particle Telescope

Portable Survey Instruments NISP-RP-01

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Example Solar Proton Event Data

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

Identify the following features and specifications for the ESP1

COMPLEX SATELLITE SYSTEMS EVERY SATELLITE IS BORN SOMEWHERE

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions

G4 Pulsed Fiber Laser

Radiation Monitoring Systems

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

Section PERIMETER SECURITY SYSTEMS

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Alpha Spectroscopy. Vacuum Light. Important things to know before you load your samples:

The European Commission s science and knowledge service. Building on core components of Technical Reachback

Radiation Monitoring System RMS

Nanotechnology-Based Gas Sensors

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

Pico Envirotec Inc., CA & ENVINET a.s., CZ NEW APPROACH TO GLOBAL MONITORING OF THE RADIOLOGICAL SITUATION; INDUSTRIAL, ENVIRONMENTAL & EMERGENCY

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

HEALTH AND SAFETY MANUAL

C-NRPP Quality Assurance Guidance for Radon Test Devices

Status Report of Active Space Radiation Detector, A-DREAMS-2 at NIRS

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

American Nuclear Society (ANS)

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

Measurement Devices. Topic 5 - Audio 56

EU Diagnostics: Recent progress & near-term opportunities. Frederic Le Guern on behalf of Glenn F. Counsell Programme Manager. 18 th September 2018

Ramon 2.2 Radon-Monitor

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Alpha Attenuation Due to Dust Loading. Amber E. Dailey Francis Marion University Savannah River Site

Developments Towards a Spacebased Wind Lidar for the International Space Station

List-mode Data Acquisition a New IEC Standard

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

BOP Ram Sensing and Interface Concept Rationale Intelligent BOP RAM Actuation Sensor System

MicroMED: the Dust Particle Analyser of the ExoMars 2020 Dust Suite

Fiber Optic Cable Qualification Update

ALPHA Radiation Safety Manual

TESTS OF ADSIL COATING

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

PM-200 Power Module Operating Instructions

FUNCTIONAL SAFETY MANUAL

Carnegie Mellon University Radiation Safety Committee

Radiation Safety issues for the PF-AR in KEK

ISO INTERNATIONAL STANDARD. Coating powders Part 13: Particle size analysis by laser diffraction

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

WM 00 Conference, February 27 March 2, 2000, Tucson, AZ RELEASE SURVEYING OF SCRAP METALS WITH THE IONSENS CONVEYOR A CASE STUDY

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

ß-Aerosolmonitor FHT 59 C

Speed and Frequency Seite 1 von 7

DEVELOPMENT OF LARGE AREA PLASTIC SCINTILLATION DETECTOR FOR RADIOACTIVE CONTAMINATION MONITOR

THE REPUBLIC OF UGANDA ATOMIC ENERGY ACT, 2008 SCHEDULE 1 FORM 2A

Equipment Required. WaveRunner Zi series Oscilloscope 10:1 High impedance passive probe. 3. Turn off channel 2.

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

Nuclear Associates

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

SENSITIVE ENOUGH TO DETECT RUNOFF CHANGES IN GROUNDWATER TRITIUM PLUMES

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

Ultraviolet radiation detector to obtain the rate of particles at different heights

Introducing the DRX-Plus Wireless, Portable DR Panel

Radiation Emitting Devices Research X-ray Safety Program

Summary. Assessment Methodology

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Chem-Bio Protection Without Chem- Bio Sensors:

Minnesota Rules, Chapter 4732 X-Ray Revision

AGENDA UNIVERSITY OF NEW HAMPSHIRE RADIATION SAFETY COMMITTEE 4th Quarter Meeting 2016 December 8, :30-2:30 pm Rudman G04

FLIM/FFS and Nanoimaging Upgrade of Olympus confocal microscopes

ND280 Construction Status Report

AERIAL RADIATION DETECTORS

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (Amends In Its Entirety)

COMPACT RADIOACTIVE AEROSOL MONITORING DEVICE FOR EARLY WARNING NETWORKS

Performance Requirements for Monitoring Pulsed, Mixed Radiation Fields Around High-Energy Accelerators

Sensors for Cell Phones

FEE Diagnostics and Commissioning. June 17, 2008

Dosimeters/Survey meters

Smoke Detection in Low Gravity Results from the Smoke Aerosol Measurement Experiments (SAME) Conducted on the International Space Station

User s Guide GPL 750

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

Simplex Panel Interface Guide

Communications. Sensing. Instrumentation. Delivering tomorrow s optical and photonic solutions today. BREAKTHROUGH PHOTONIC PRODUCTS

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

GLAST Large Area Telescope: Collaboration Meeting. AntiCoincidence Detector: From Rome 2003 to SLAC September 28-30, 2004

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

RAM GENE / RAM GENE-1

Battery-operated, hand-held alarm and measuring instruments for radiation protection

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl

MetRad1 Handheld Metal/Gamma Detection Unit. Operation Manual. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 BNC

Instruction Manual WARNING

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price.

Passive infrared ceiling sensor

Transcription:

NASA Plans for Dosimetry in Support of Manned Spaceflight Expedition 40 Lands - Three crew members from the International Space Station returned to Earth Wednesday after 169 days E. J. Semones, A. A. Bahadori, D. Fry, K. Lee, M. Kroupa, N. Stoffle, L. Pinsky, C. Amberboy, R.Gaza, R. Rios, M. Leitgab, K. Beard, and John Flores-McLaughlin

NASA Programs ISS Program Support to sustain/develop systems to ensure radiation health of ISS crews ISS-TEPC/IV-TEPC, ISS-RAD, Passive Detectors (1 year mission requires new effort) Advanced Exploration Systems (AES) NASA's Advanced Exploration Systems (AES) program is pioneering new approaches for rapidly developing prototype systems, demonstrating key capabilities, and validating operational concepts for future human missions beyond Earth orbit. AES activities are uniquely related to crew safety and mission operations in deep space, and are strongly coupled to future vehicle development. ISS-REM, BIRD, HERA, ANS (we call team developing these the REM team) Partnership with AMS 02 (Alpha Magnetic Spectrometer- state of the art particle physics detector). AMS02 data is available. Contract with University of Hawaii to deliver particle flux of protons and He.

Tissue Equivalent Proportional Counters ISS-TEPC Current on-orbit unit functioning nominally (since 2007) Version first flown in 2000, developed in late 1990s. Hardware exceeding design life, no indication of degradation IV-TEPC project initiated to Support ISS operations to 2020/24 Part of new NASA monitoring suite, that will also include ISS RAD First time 2 TEPCs operating simultaneously on ISS Flight Model (FM) 1 had flash memory card failure, replaced by Flight Model (FM) 2 FM-2 IV-TEPC will be surveying ISS after checkout and comparison with current TEPC

IV-TEPC ISS IV-TEPC FM-1 unpackaged and placed on SM panel 327 on April 23, 2012 Operated successfully until October 09, 2013 New IV-TEPC (Flight Model 2) delivered to ISS on Orb-2. Deployed on July 28, 2014 at SM P328.

IV-TEPC Flight Model 2 Status

Timeline of Events Jul 18 Jul 21 Jul 22 Jul 23 Jul 24 Jul 25 Crew successfully assembled / deployed onto SM Panel 328. At ~30 minutes of operation, Dose Rate and Dose Equivalent Rate telemetry from the Large Detector (installed on Channel 1) went to 0.000. BME dumped all available science/engineering data, syslog files, and performed a BIT (extended cyclic) dump. The data was passed to Engineering and SRAG for analysis. BME switched the device into and out of Standby mode, and then performed a soft system reset. This had no effect on the data from Channel 1. During evening DPC (~1:45CST), the crew was instructed to perform a hard reset of the instrument. No effect on the data from Channel 1. BME dumped all science/engineering data (contained the results of three Pulser Tests) and all configuration files. MER-CHeCS drafted a Chit for crew to remove the Large Detector from Channel 1, inspect it for obvious signs of damage, then return it to Channel 1 if no damaged noted. BME performed another soft system reset in order to trigger a fourth Pulser Test. All science/engineering data files and all syslog files were also downlinked. Discussed the forward plan for IV-TEPC troubleshooting. Chit submitted to perform the Large Detector Inspection; separate activity to move the Large Detector to Channel 2 should not be pursued until photo analysis is completed.

Channel 1 Summary Spectrometer IV 1 failed at 30 minutes IV1 Dose was appropriate before the failure The failure developed over 2 to 3 minutes 3 power supply currents exhibited abnormal behavior coincident with the failure. Relation to failure not understood Pulser Tests Initial pulser test on start-up: normal After failure: No pulser counts registered in first test Subsequent tests: 2 counts, 438 counts (Normal: 3900 counts) Failure to register pulser counts is indicative of: Fault in the processing circuit (Detector might be OK) Fault in Pulser 1 (Detector might be OK) Fault in the Detector (interfering with pulser tests)

Channel 2 Summary Spectrometer IV2 Dose rates All evidence supports FLT2 IV2 as operating properly Pulser Tests First two pulser tests: normal Second two tests: Appears that Pulser 2 attenuator is always enabled (altering the pulse magnitudes sent) Abnormal pulse count rate Abnormal state is understood and acceptable for conducting pulser tests Channel 2 electronics are operationally normal

Next Steps Crew activity to inspect and photo document the Large Detector and Spectrometer Interface for damage completed no damage was observed, reinstall Large Detector onto Channel 1. Currently assessing whether to proceed with next troubleshooting step to swap the detectors large detector to be placed on Channel 2

IV-TEPC Plans Complete checkout of FM-2 Possibly use only single Large Detector until FM-1 (on ground) can be prepared for launch Resume survey of ISS with IV-TEPC, relocating every ~ 4 weeks ISS-TEPC will operate until failure no plans to refurbish at this point

IV-TEPC latest data

ISS RAD ISS RAD - CPD Fast Neutron Detector (FND) MSL RAD Gd Shield

ISS-RAD Status Major Accomplishments Flight Unit Fabrication Completion - 3/28/14 Certification and Science Testing Performed to date: Vibration & Thermal (at SwRI) 1553 Data and Commanding (at JSC) EMI (at JSC) Science Testing and Calibration (3 runs at NSRL, 1 run at PTB) Cyclotron Testing (8/4-6, at Indiana University) Power Quality (this past week, at JSC) FND Rework completed. Delivered to JSC 7/14. Post FND Repair Testing at SwRI: Repeat Burn-In (24hr) Repeat Thermal Cycle (x2) on Rad Detector New tailored Random Vibration (FND002 only) Certification and Science Testing Remaining: Touch Temperature (TBD, at JSC) 1553 RT Validation (TBD, at JSC) SSC Interface (TBD, at JSC) Science and Calibration (10/6-10, PTB Germany)

ISS-RAD Plans ISS-RAD manifest on Orb-4 scheduled ~ 4/15 ISS-RAD to be delivered for launch ~ 12/14 Long term plan is to have continuous measurement campaign in USOS until 2024. ISS-RAD will be relocated several times per year but not as frequent as IV-TEPC

AES Development Path: putting new sensor technology into operational detector system ISS REM BIRD (EFT-1) EM-1,2 HERA EM-3+ HERA Proof-of-concept Demonstrates feasibility of Timepix space dosimetry Intermediate step Stand-alone data acquisition Off-line data processing Springboard Significant progress towards operational active area monitoring Operational active radiation area monitoring for Orion MPCV Use of large portable instruments (i.e. TEPC) not possible for MPCV

ISS REM BIRD HERA Continue to collect/analyze data Web server data display and analysis First quarterly report Deploy REM units in BEAM Collaboration with LaRC on model comparisons, PI Martha Clowdsley Possible increase of number of units +3-5 units Flight hardware in JSC bond Tested S/N 1002 at NSRL Ship to KSC on or before EFT-1 flight Successfully completed SRR PTRS baseline imminent Design is progressing FY14 REM Accomplishments REM Plans Table-top review to be held September 30 Possible Tech Demo of HERA prototype on ISS

REM Data for Modeling Data starts midnight GMT Nov 16, 2013 and ends just before midnight GMT Nov 25, 2013 The REM SN 1005 was located in the US Lab approximately 2 inches from the border between racks 3 & 4 overhead Data covers 240 hours minus 2 weekly reboots of ~ 8.5 hrs each Total data covers ~223 hrs, with ~187,000 points (~4 sec average interval between data points) REM Dosimeter location

ISS CAD Model Updates - LaRC The CAD model included updated US Lab, Node 1 & 2, and Columbus models (overlapping parts fixed, parts modeled as surfaces removed/fixed, masses correct at the rack or structure level). Remaining modules and structures were not updated, but uniform densities were assigned to parts in each module to ensure that total module masses agree with those on the JSC ISS Mass Properties Group website.

Updated Modules-LaRC High Fidelity models in LaRC Test assembly

HERA Instrument Summary HERA: Hybrid Electronic Radiation Assessor Measures absorbed dose in real-time Time-resolved absorbed dose rate and flux Provide Caution and Warning signaling and display (EM-2) Provides in-flight binning of particle charge and energy Stores/downlinks raw data for detailed analysis Data usage Operational radiation protection decisions Risk Assessment MPCV interfaces Connected to Orion PDU RS-422 data bus 120 VDC input Real-time status telemetry Periodic full data download

HERA HSU and HPU HERA Sensor Unit (HSU) CAD Representation HERA Power Unit (HPU) CAD Representation

HERA Instrument Summary HERA: Hybrid Electronic Radiation Assessor Measures absorbed dose in real-time Time-resolved absorbed dose rate and flux Provide Caution and Warning signaling and display (EM-2) Provides in-flight binning of particle charge and energy Stores/downlinks raw data for detailed analysis Data usage Operational radiation protection decisions Risk Assessment MPCV interfaces Connected to Orion PDU RS-422 data bus 120 VDC input Real-time status telemetry Periodic full data download

HERA Physical/Functional HERA system: 1 HERA Power Unit (HPU) Up to 3 HERA Sensor Units (HSU) per HPU EM-1: detection and recording Will rely on vehicle power Will store all data on the HSU and HPU Capability to be powered on/off by PDU. EM-2: same as EM-1 plus will be tied into Caution & Warning system to alert crew to shelter

HERA Year in Review - Interface Diagram

Advanced Neutron Spectrometer (ANS) Mark Christl at MSFC Objectives A compact low-power neutron monitor for future precursor/long duration manned missions Neutrons are generated from steady rate GCR and transient solar event particle fluxes (protons) Habitats and Planetary Surfaces are important sources of secondary neutrons Focus on developing a neutron detector that distinguishes neutrons in mixed radiation fields of charged particles (light and heavy nuclei, secondary particles) and neutral particles (neutrons, gamma rays) Measure a broad spectrum of neutrons in a fluctuating particle background Alarming capability for SPEs In FY14 develop a second generation prototype of the ANS, measure key performance parameters and demonstrate measurement performance

Gate and Capture Technique for neutrons Thermal Neutron

FY14 ANS Accomplishments Completed second generation ANS design and fabrication System level functional testing completed; long term testing continues Calibrated signal response of the photomultplier tubes using pulsed laser and 200 MeV primary protons Measured and simulated collection efficiency and response uniformity for the composite scintillator Exposed ANS to mixed field radiation environment at IUCF using 100 MeV protons incident on a aluminum target to produce neutrons, gamma, and other radiation components Developed spectral un-folding technique and compared with incident beam Supporting neutron measurements at Oak Ridge with tagged neutron source for assessment of detector efficiency and response simulations Preliminary environmental testing: vibration and radiation Achieved key performance parameters: Mass 2.3 kg; Power 5.3 W; Energy range: 0.5<E<50 MeV

FY14 ANS Hardware development Li-6 doped glass scintillating fiber array (>5000 fibers 120 microns diameter) Fiber array cast in plastic scintillator detector (1 liter), machined and polished surfaces Electronics and Data Acquisition 28

FY14 ANS GEN-II Instrument ANS GEN-II (3U CubeSat formfactor) Acquiring neutron data from radioactive AmBe source FY14 HQ Milestone: Conduct benchtop demonstration of ANS September 29, 2014 29

ANS Development Plans Phase-I Technology Advancement (2012-2014) Develop an advanced neutron detector design for measuring neutrons in mixed radiation fields Verify critical measurement features Compare performance to state-of-the-art Advance TRL to full-size proto-type Achieve key performance parameters Environmental test and qualification of detector Document measurement performance and data analysis Phase-II Spaceflight Demonstration (2015-2017) Develop plan and schedule for ISS test flight (will compare to ISS-RAD FND) Identify ISS interfaces: mechanical, power and telemetry Design and fabricate ISS version of ANS Complete environmental testing Phase-III Operational (2018+) Develop operational and technical requirements to support manned exploration mission

FY14 ANS Accelerator exposure ANS Testing Proton particle beam and aluminum target ANS GEN-II

AMS-02

AMS-02 Data Plans Through collaboration with University of Hawaii Dr. Bindi developing long term collaboration with AMS-02 team to provide to elemental flux to help GCR model development for operation use at NASA: BO-2013 Model updates Data will be made available for protons and He in the coming year

Summary ISS dosimetry remains robust and configuration includes 2 TEPCs (3 separate detectors) ISS-RAD charged particle and neutron spectrometer At least 5 REM units (hopefully more) Continued full use of RAMs and CPDs, 1 year mission will use mid-year swapout ANS demonstration for supplemental neutron data MPCV BIRD will provide data critical on MCPV CAD model-trapped radiation HERA project in full swing HERA will be able adapt to improvement in Timepix detectors NASA fully committed to developing systems based on Timepix technology to support future exploration missions

NASA switch to solid state detectors for operational dosimetry requires long lead time to develop analysis tools and use experience. We still have long way to go.