Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Similar documents
SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

MODELS K2EU060A, K4EU090A, & K3EU120A

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

INSTALLATION MANUAL (AIR COOLED) SPLIT-SYSTEM AIR CONDITIONER MODEL: LA120 NOTES, CAUTIONS AND WARNINGS SAVE THIS MANUAL B-0203

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 10, 16, 26, 36 & 72

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 60 HZ MODELS: EF-10 & FF-10

ACCESSORY KIT INSTALLATION INSTRUCTIONS

SPLIT-SYSTEM EVAPORATOR BLOWER (AIR COOLED) INSTALLATION INSTRUCTION Supersedes: Nothing N4C-0500

INSTALLATION INSTRUCTION

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

ACCESSORY KIT INSTALLATION INSTRUCTIONS

TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM HEAT PUMP FOUR PIPE SYSTEM DESCRIPTION E*FB180 & 240 F*EH180 & & 20 NOMINAL TONS INDOOR UNIT

Models PF1A PF1B PACKAGED AIR-HANDLING UNITS. 6to10Tons. Form No. PDS PF1A.72.1 FEATURES/BENEFITS

Product Data FEATURES/BENEFITS. 524J PACKAGED AIR -HANDLING UNITS WITH PURONr REFRIGERANT SIZES 07, 08, 12, 14, 16. Indoor air quality features

MODELS B1PA024, 030 AND 036

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

BAC / BHC SERIES 7-1/2 to 20 Ton Air Handlers

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

INSTALLATION INSTRUCTION-50 Hz

VertiCool Aurora Engineering Guide

Product Data FEATURES/BENEFITS 524J***H 6 TO 20 TON DIRECT EXPANSION PACKAGED HEAT PUMP AIR -HANDLING UNIT. Indoor air quality features 524J-H 07-12

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

C13-Series Engineering Guide

INSTALLATION MANUAL AFFINITY SERIES SINGLE PACKAGE AIR CONDITIONERS ELECTRIC/ELECTRIC, AIR-COOLED. MODELS: D1EB036 thru Thru 5 Ton (10 SEER)

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features

INSTALLATION INSTRUCTION

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

COMMERCIAL AIR HANDLER

INSTALLATION INSTRUCTION

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

MODELS B3CH 048 AND 060 (WORLD 50 HZ)

SUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES

COMMERCIAL AIR HANDLER

Supersedes: N2Y (498) N2Y (799) MODELS B1HH018 THRU THRU 5 TON (12 SEER)

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

VariCool VAV Engineering Guide

technical guide Water-Cooled Self-Contained Units

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

SUNLINE 2000 ELECTRIC / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: N7Y (993) 530.

KAP Horizontal Product Coolers

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

Water-Cooled Self-Contained Units

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

SUNLINE SERIES SINGLE PACKAGE AIR CONDITIONERS. INSTALLATION INSTRUCTION Supersedes: Nothing N3Y (394) MODELS D*SC360 & 480 INSPECTION

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

INSTALLATION INSTRUCTIONS FAS/FHS Series, Package Air Handling Units 6 to 25 Ton Air Conditioners 6to20TonHeatPump

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Installation, Start-Up and Service Instructions

R-410A. NJ-10 thru -20, 4-Pipe Ton, 60 Hertz TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & YTG-A-0506

Split System Heat Pumps

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

R-410A AFFINITY SERIES DEX DEY Ton

CWA4 Chilled & Hot Water Fan Coil

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

40 RM/RMS Packaged Air-Handling Units

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

INSTALLATION MANUAL SUNLINE 2000 SINGLE PACKAGE HEAT PUMP BCH 036, 048 & 060

INSTALLATION INSTRUCTION

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

Supersedes: N2W (398) N2Z (1298) MODELS BCCB 090 & 120, MODELS BECB090 & 120 (9 EER) 208/230/460 VOLT MODELS ONLY

PACKAGE AIR CONDITIONER

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

INSTALLATION INSTRUCTION

CoolSpot Engineering Guide

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Transcription:

Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes and aluminum fins, expansion valve(s), distributor(s), throwaway filters, a centrifugal blower, a blower motor, an adjustable belt drive, a blower motor contactor and a small holding charge of Refrigerant-22. The unit is manufactured under ISO 9002 Quality System Certification. The unit is shipped in the vertical position ready for field installation. It can be installed for horizontal operation by reversing the position of the solid bottom panel with the return air duct flange on the front of the unit. ACCESSORIES FIELD INSTALLED SUPPLY AIR PLENUMS A fully insulated plenum is available for free standing units located within the conditioned space, are shipped knocked-down for easy field assembly, are finished to match the exterior of the basic unit, and have double deflection grills that can be adjusted to vary the throw, spread and drop of the supply air. RETURN AIR GRILL An expanded metal grille is available for free standing units located within the conditioned space. It is finished to match the exterior of the basic unit and is shipped in one piece for easy installation. BASES A base is available to raise vertical units above the floor. Outdoor air may be introduced through the base by cutting an access opening to accommodate the outdoor air duct connection. The base is finished to match the exterior of the basic unit. It may have to be insulated in the field for certain applications. THREE-PHASE ELECTRIC HEATERS Electric heaters are available in five capacities to provide maximum flexibility. Both the air conditioning unit and the heater can be selected to precisely match the cooling and heating requirements of the conditioned space. These heaters are designed for easy field-installation over the supply air opening of the unit. Every heater is fully protected against excessive current and temperature by fuses and two high limit thermostats. Units with electric heat require only one power supply for both the heating elements and the supply air blower motor. The power wiring can be protected by either dual element/time delay fuses or an inverse time circuit breaker. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

TABLE OF CONTENTS DESCRIPTION................................... 1 ACCESSORIES FIELD INSTALLED................ 1 NOMENCLATURE................................ 3 LIST OF FIGURES Fig. # Pg. # 1 VERTICAL AND HORIZONTAL APPLICATION KEU180.................................... 3 2 UNIT DIMENSIONS AND CLEARANCES......... 8 3 STEAM COIL................................ 9 4 HOT WATER COIL........................... 9 5 ACCESSORY DIMENSIONS.................. 11 LIST OF TABLES Tbl. # Pg. # 1 HEATING CAPACITY - ELECTRIC HEAT ACCESSORY............................... 4 2 STEAM COIL CAPACITY, KW @ 14 KPA/MBH @ 2 PSIG...................................... 4 3 HOT WATER COIL CAPACITY, KW/MBH......... 4 4 PRESSURE DROP VS. L/S / GPM.............. 4 5 CAPACITY CORRECTION VS. L/S / GPM........ 4 6 BLOWER PERFORMANCE.................... 5 7 ACCESSORY STATIC RESISTANCE (IWG)....... 5 8 SUPPLY AIR PLENUM PERFORMANCE DATA, M 3 /S...................................... 6 9 SUPPLY AIR PLENUM PERFORMANCE DATA, CFM...................................... 6 10 BLOWER MOTOR AND DRIVE DATA............ 6 11 PHYSICAL DATA............................ 7 12 ELECTRIC HEATER DIMENSIONS KEU180..... 11 13 ELECTRICAL DATA......................... 11 14 ELECTRICAL DATA WITH ELECTRIC HEAT..... 11 2 Unitary Products Group

NOMENCLATURE K4 EU 180 A 50 Product Categor y K = Split System Evaporator Blower Voltage Code 50 = 380/415-3-50 Product Generation 4 = Design Level Refrigerant Line Connections A = Cooling Only Product Identifier EU = Evaporator Blower Unit Nominal Cooling Capacity - MBH 180 = 180 MBH (52.7 kw) ACCESSORIES-FIELD INSTALLED (CONT.) HOT WATER COILS This drainable coil has two rows of 13mm (1/2 in.) copper tubes, eight aluminum fins per 25mm (1 in.), a casing that is finished to match the exterior of the basic unit, but no water control valve. The coil slides out of the casing for easy field installation. It should be mounted between the unit coil and blower section. STEAM COILS The non-freeze coil has one row of 25mm (1 in.) copper tubes, a 16mm (5/8 in.) copper tube inside each 25mm (1 in.) tube to distribute the steam evenly across the entire length of the coil, eight aluminum fins per 25mm (1 in.), a casing finished to match the exterior of the basic unit, but no steam control valve. The coil slides out of the casing for easy field installation and is pitched in the casing to facilitate condensate drainage. It should be mounted between the unit coil and blower sections. SUSPENSION KIT Suspension kit 1HH0451 is available for units installed horizontally. The accessory includes two channel iron supports and the hardware to secure them to the top of the unit. The hanger rods must be supplied by the field. THERMOSTATS Wall-mounted thermostats and subbases (24volt) with system and fan switches are available to control the operation of these split system air conditioners. (VERTICAL POSITION) (HORIZONTAL POSITION) FIGURE 1 - VERTICAL AND HORIZONTAL APPLICATION KEU180 This unit has two distinct modules, a blower module and al coil module. The unit is always shipped in the vertical position with a vertical air discharge as shown in illustration (a). The blower module can be repositioned in the field as shown in illustration (b) or (c) for maximum flexibility. The Supply air Plenum, Return Air Grille and Base accessories can be applied on arrangment (a). The Return Air Grille and Base accessories can be applied on arrangement (b). The Supply Air Plenum, Return Air Grille and Suspension accessories can be applied on arrangement (c). Unitary Products Group 3

TABLE 1: HEATING CAPACITY - ELECTRIC HEAT ACCESSORY NOMINAL RATINGS 1 CAPACITY 1 HEATER MODEL VOLTAGE TEST PER STAGE 1 PER STAGE 2 KW MBH KW MBH KW MBH 2HS04501050 415 7.5 25.6 7.5 25.6 - - 2HS04501650 415 12.0 40.9 7.5 25.6 4.5 15.3 2HS04502650 415 19.4 66.5 12.0 40.9 7.5 25.6 2HS04503650 415 26.9 91.9 12.0 40.9 15.0 51.1 1. Capacity Ratings do not include the heat generated by the air blower motor. 2. For 380 volts, multiply the mbh and kw values by (380/415) 2 or 0.838. TABLE 2: STEAM COIL CAPACITY 1, kw @ 14 kpa/mbh @ 2 psig 2 STEAM COIL MODEL BLOWER MODEL USED ON 1NF0452 180 DRY BULB TEMPERATURE OF AIR ENTERING COIL, C/ F m 3 /s / CFM -12 / 10-1 / 30 10 / 50 21 / 70 2.3 / 4800 298.2 / 1018 268.4 / 916 236.7 / 808 211.5 / 722 2.8 / 6000 329.1 / 1124 297.0 / 1014 265.6 / 907 234.1 / 799 3.4 / 7200 356.4 / 1216 321.8 / 1099 287.9 / 983 254.0 / 867 1. These capacities do not include any blower motor heat. 2. Multiply these capacities by the following factors to correct for higher steam pressures. Steam Pressure, psig 35 / 5 70 / 10 105 / 15 140 / 20 210 / 25 Capacity correction factor 1.06 1.12 1.19 1.25 1.30 NOTE: Steam rate (kg/hr) = 0.66 x kw, (lb./hr.) = 1.025 x MBH CAUTION: Do NOT operate a motor above its nominal HP rating when a unit is equipped with a steam coil accessory. TABLE 3: HOT WATER COIL CAPACITY 1, kw/mbh WATER COIL MODEL BLOWER MODEL USED ON l/s / GPM 1HW0451 180 0.95 / 15 ENTERING WATER TEMP. MINUS ENTERING AIR TEMP., C/ F m 3 /s / CFM 21 / 70 32 / 90 43 / 110 54 / 130 66 / 150 2.3 / 4800 135.5 / 463 175.1 / 598 215.8 / 737 257.4 / 879 294.1 / 1004 2.8 / 6000 150.0 / 512 195.0 / 666 240.3 / 820 285.9 / 976 326.6 / 1115 3.4 / 7200 162.4 / 554 210.8 / 720 260.4 / 889 309.8 / 1058 354.3 / 1210 1. These capacities do no include any blower motor heat. NOTE: Water Temperature Drop, C = 16.71 x kw / l/s, F = 2 x MBH / GPM CAUTION: Do NOT operate a motor above its nominal HP rating when a unit is equipped with a hot water coil accessory. TABLE 4: PRESSURE DROP VS. L/S / GPM TABLE 5: CAPACITY CORRECTION VS. L/S / GPM 1HW0450 l/s / GPM 0.63 / 10 1.26 / 20 1.90 / 30 Pressure Drop, kpa / psig 0.7 /.10 2.2 / 0.32 4.7 / 0.67 1HW0450 l/s / GPM 1.26 / 20 1.90 / 30 Capacity Correction 1.12 1.15 1HW0451 l/s / GPM 0.95 / 15 1.90 / 30 2.83 / 45 Pressure Drop, kpa / psig 1.2 / 0.17 4.0 / 0.58 8.5 / 1.22 1HW0451 l/s / GPM 1.90 / 30 2.83 / 45 Capacity Correction 1.11 1.15 Meters (H 2 O) = 45,942 x kpa Feet (H 2 O) = 2031 x psig 4 Unitary Products Group

TABLE 6: BLOWER PERFORMANCE SUPPLY AIR BLOWER PERFORMANCE 1 - (m 3 /s) BLOWER SPEED RPM (Pa) (Pa) (Pa) AIRFLOW 1. Unit resistance is based on a wet evaporator coil and clean filters. 2. Available static pressure in IWG (Pa) to overcome the resistance of the duct system and any accessories added to the unit. Refer to Table 7 for the resistance of these accessories and to Table 10 for additional motor and drive data. NOTE: Motors can be selected to operate into the service factor because they are located in the moving air stream, upstream of any heating device. (Pa) (Pa) 2.26 m 3 /s 2.55 m 3 /s 2.83 m 3 /s 3.11 m 3 /s 3.40 m 3 /s 600 114 1.07 1.34 74 1.25 1.56 27 1.46 1.80 - - - - - - 615 136 1.15 1.43 99 1.33 1.64 55 1.55 1.90 3 1.08 2.20 - - - 700 208 1.36 1.68 174 1.58 1.94 134 1.81 2.22 89 2.06 2.54 30 2.32 2.82 800 312 1.77 2.17 285 2.01 2.47 248 2.26 2.74 206 2.51 3.05 154 2.79-900 422 2.20 2.68 404 2.46 2.99 311 2.73 - - - - - - - SUPPLY AIR BLOWER PERFORMANCE 1 - (CFM) BLOWER SPEED RPM (IWG) (BHP) (IWG) (BHP) (IWG) AIRFLOW (BHP) (IWG) (BHP) (IWG) (BHP) 4800 CFM 5400 CFM 6000 CFM 6600 CFM 7200 CFM 600 0.46 1.44 1.34 0.30 1.68 1.56 0.11 1.96 1.80 - - - - - - 615 0.55 1.54 1.43 0.40 1.79 1.64 0.22 2.08 1.90 0.01 2.41 2.20 - - - 700 0.84 1.83 1.68 0.70 2.12 1.94 0.54 2.43 2.22 0.36 2.77 2.54 0.12 3.12 2.82 800 1.26 2.38 2.17 1.15 2.70 2.47 1.00 3.03 2.74 0.83 3.37 3.05 0.62 3.75-900 1.70 2.95 2.68 1.63 3.30 2.99 1.52 3.67 - - - - - - - RPM range for standard factory-mounted drive components. Exceeds the output limitation of the standard factory-mounted blower motor. TABLE 7: ACCESSORY STATIC RESISTANCE (IWG)/(Pa) EXTERNAL STATIC PRESSURE DROP RESISTANCE ACCESSORY IWG (Pa) BLOWER CFM / m 3 /s 4800 / 2.26 5400 / 2.55 6000 / 2.83 6600 / 3.11 7200 / 3.40 10kW 0.04 / 10 0.05 / 12 0.06 / 15 0.08 / 20 0.10 / 25 Electric Heat 16kW 0.07 / 18 0.09 / 21 0.11 / 27 0.14 / 35 0.17 / 42 26kW 0.13 / 32 0.16 / 40 0.20 / 50 0.24 / 60 0.29 / 72 36kW 0.20 / 50 0.24 / 60 0.29 / 72 0.35 / 87 0.42 / 106 Supply Air Plenum 0.03 / 8 0.04 / 10 0.05 / 12 0.06 / 15 0.07 / 18 Return Air Grille 0.04 / 10 0.05 / 12 0.06 / 15 0.07 / 18 0.08 / 20 Hot Water Coil 0.18 / 45 0.22 / 55 0.26 / 64 0.30 / 74 0.34 / 84 Steam Coil 0.15 / 37 0.18 / 45 0.22 / 55 0.26 / 64 0.30 / 74 Unitary Products Group 5

TABLE 8: SUPPLY AIR PLENUM PERFORMANCE DATA, M 3 /S m 3 /s Face Velocity (FPM) Sound Power db (10) 12 Watts 0 Throw (Meters) 3 Vertical Louvers 1 (Plan Spread (Meters) 3 Horizontal Louvers 2 (Elevation 0 22-1/2 Throw (Meters) 3 Angle of Deflection Vertical Louvers 1 (Plan Spread (Meters) 3 18 0 Horizontal Louvers 2 (Elevation Throw (Meters) 3 Vertical Louvers 1 (Plan Spread (Meters) 3 Horizontal Louvers 2 (Elevation Min. Max. Min. Max Drop (Meters) 4 Min. Max Min. Max Drop (Meters) 4 Min. Max. Min. Max. Drop (Meters) 4 2.26 268 26 25.5 40.1 9.7 14.6 7.0 3.6 18.5 28.9 11.6 17.0 6.4 3.3 14.0 22.0 22.2 34.0 3.6 1.8 2.55 304 28 28.9 45.3 10.9 16.4 7.3 3.6 20.7 32.5 12.8 19.2 6.7 3.3 15.8 24.6 24.6 37.7 3.6 1.8 2.83 337 30 32.2 50.1 11.9 18.0 7.6 4.0 23.1 36.2 14.0 21.0 7.0 3.6 17.3 27.0 27.4 42.0 4.0 2.1 3.11 371 33 35.3 55.3 13.1 20.0 7.9 4.0 25.5 40.0 15.2 23.1 7.0 3.6 19.2 29.8 30.1 46.2 4.0 2.1 3.40 404 36 38.3 60.5 14.0 21.3 8.2 4.3 28.0 43.5 16.7 25.2 7.3 3.6 20.7 32.5 33.1 50.5 4.3 2.1 45 18 0 1. Adjusting the vertical louvers will vary the throw, the spread and the drop. 2. Adjusting the horizontal louvers will only vary the drop. 3. The velocity of the air will be 38.1m/min. at the minimum distance and 24.38m./min. at the maximum distance. 4. The velocity of the conditioned air at the bottom of the drop will be 15.24m./min. Drafts will occur if the drop extends into the occupied level of the conditioned space. TABLE 9: SUPPLY AIR PLENUM PERFORMANCE DATA, CFM Angle of Deflection 18 CFM Face Velocity (FPM) Sound Power db (10) 12 Watts 0 Throw (Feet) 3 Vertical Louvers 1 (Plan Spread (Feet) 3 Horizontal Louvers 2 (Elevation 0 22-1/2 Throw (Feet) 3 Vertical Louvers 1 (Plan Spread (Feet) 3 Horizontal Louvers 2 (Elevation Throw (Feet) 3 Vertical Louvers 1 (Plan Spread (Feet) 3 Horizontal Louvers 2 (Elevation Min. Max. Min. Max Drop (Feet) 4 Min. Max Min. Max Drop (Feet) 4 Min. Max. Min. Max. Drop (Feet) 4 4800 880 26 84 132 32 48 23 12 61 95 38 56 21 11 46 72 73 112 12 6 5400 1000 28 95 149 36 54 24 12 68 107 42 63 22 11 52 81 81 124 12 6 6000 1110 30 106 165 39 59 25 13 76 119 46 69 23 12 57 89 90 138 13 7 6600 1220 33 116 182 43 65 26 13 84 131 50 76 23 12 63 98 99 152 13 7 7200 1330 36 126 199 46 70 27 14 92 143 55 83 24 12 68 107 109 166 14 7 45 1. Adjusting the vertical louvers will vary the throw, the spread and the drop. 2. Adjusting the horizontal louvers will only vary the drop. 3. The velocity of the air will be 38.1m/min. at the minimum distance and 24.38m./min. at the maximum distance. 4. The velocity of the conditioned air at the bottom of the drop will be 15.24m./min. Drafts will occur if the drop extends into the occupied level of the conditioned space. TABLE 10: BLOWER MOTOR AND DRIVE DATA MOTOR (kw/hp) BLOWER RANGE (RPM) 18 0 18 0 ADJUSTABLE MOTOR PULLEY FIXED BLOWER PULLEY BELT PITCH DIA. (MM/IN.) BORE (MM/IN.) PITCH DIA. (MM/IN.) BORE (MM/IN.) DESIGNATION PITCH LENGTH (MM/IN.) 2.2 / 3 615 / 810 86-112 / 3.4-4.4 22.2 / 7/8 203 / 8.0 25 / 1 A54 1405 / 55.3 18 6 Unitary Products Group

TABLE 11:PHYSICAL DATA Evaporator Coil Centrifugal Blowers Blower Motor 1 Filters (Throwaway) (6 Req d) Component 1. Refer to data in Table 10 for complete motor specifications. Description Rows Deep 3 Rows High 32 Finned Length (mm/in.) 1372 (54) Fins per 25mm (1 in.) 13 Tube O.D. (mm/in.) 9.5 (3/8) Face Area m 2 (sq. ft.) 1.15 (12.4) Wheel Dia. x Width (in./mm) 457 x 457 (18 x 18) kw (HP) 2.2 (3) Size mm (in.) 180 508 x 508 x 25 (20 x 20 x 1) Face Area m 2 (sq. ft.) 1.55 (16.7) Operating Charge Refrigerant 22 kg. (lbs.) 2.5 / 5.5 Drainable, Hot Water Coil Accessory Non-Freeze, Steam Distributing Coil Accessory Electric Heater Elements Weight (Lbs/kg) Accessory Operating Weight kg (lbs)) Rows Deep 2 Fins per 25mm (1 in.) 8 Tube O.D. (mm/in.) 12.7 (1/2) Face Area m 2 (sq. ft.) 0.63 (6.8) Supply/Return (Copper) OD mm (in.) 34.9 (1-3/8) Rows Deep 1 Fins per 25mm (1 in.) 8 Tube O.D. (mm/in.) x ID mm (in.) 25 (1) x 15.9 (5/8) Face Area m 2 (sq. ft.) 0.94 (10.1) Inlet/Outlet (Brass NPTE mm (in.) 38.1 (1-1/2) % Nickel 59.2 % Chromium 16 Watt Density, watts / sq. in. 59 Face Area m 2 (sq. ft.) 0.28 (3.0) Shipping 218 (480) Operating 193 (425) Supply Air Plenum 52 (115) Base 29 (65) Return Air Grille 9 (20) Steam Coil 66 (145) Hot Water Coil 61 (135) 10 kw 30 (66) Electric Heaters 16 kw 32 (70) 26 kw 34 (74) 36 kw 35 (77) Unitary Products Group 7

(492) 19-3/8 (556) 21-7/8 AIR OUT (1543) 60-3/4 (149) (140) 5-7/8 5-1/2 (43.6) 1-23/32" KNOCKOUT (Used only with Electric Heat Accessory) (22.2) 7/8" KNOCKOUT FOR CONTROL WIRING (54) 2-1/8 (22.2) 7/8" KNOCKOUT FOR CONTROL WIRING (184) 7-1/4 (419) 16-1/2 (22) 7/8 (152) 6 (480) 18-7/8 (822) 32-3/8 BLOWER MOTOR AND DRIVE ACCESS PANEL (Always nearest wiring connection side of unit) Located on opposite side ONLY when the blower section has been rotated 180 degrees from position shown. BLOWER SECTION (79) (483) 3-1/8 19 (31.7) 1-1/4" KNOCKOUT FOR LIQUID CONNECTION* ALTERNATE (66.6) 2-5/8" KNOCKOUT * (702) 27-5/8 (159) 6-1/4 (254) 10 (66.6) 2-5/8" KNOCKOUT FOR SUCTION CONNECTION* COIL SECTION (79) 3-1/8 (79) 3-1/8 (1591) 62-5/8 (60) 2-3/8 (56) 2-3/16 AIR IN (31.7) 1-1/4 " KNOCKOUT (22.2) 7/8" O.D. DRAIN CONNECTION* (Must be trapped) (1432) 56-3/8 (25) 1 (803) 31-5/8 FILTER ACCESS PANEL Filters can be removed through either side of the unit. *Refer to INSTALLING REFRIGERANT MAINS when piping through the opposite side of the unit. (56) 2-3/16 All dimensions are in millimeters and inches. They are subject to change without notice. Certified dimensions will be provided upon request. FIGURE 2 - UNIT DIMENSIONS AND CLEARANCES ACCESSORIES ELECTRIC HEATER - Add 381mm (15 ) to unit height when using 10, 16, 26 or 36kW heater. SUPPLY AIR PLENUM - Add 686mm (27 ) to unit height when used. BASE - Add 610mm (24 ) to unit height when used. MINIMUM CLEARANCES (mm/in.) Side with RETURN AIR opening 610/24 Side with SUPPLY AIR opening 1 610/24 Side with PIPING CONNECTIONS 2 1549/61 Side opposite with PIPING CONNECTIONS 3 660/26 Bottom 4-1. Overall dimensions of the unit will vary if an electric heater, a supply air plenum or a base is used. 2. This dimension is required for removal of the DX coil. Only 660mm (26 ) is required for normal service. 3. If the DX coil has to be removed, this dimension is required to loosen screws that secure the coil to the unit frame. This dimension will also be required for blower motor access if the piping connections are made on the opposite side of the unit. 4. Allow enough clearance to trap the condensate drain line. 8 Unitary Products Group

C B 38mm (1-1/2 ) NPTE CONN S. F Coil 1NF0452 1 Unit 180 Steam Coil Dimensions mm (in.) A B C D E F 1543 (60-3/4) 819 (32-1/4) 152 (6) 76 (3) 89 (3-1/2) 1. Installs between the coil and blower section of the unit. 445 (17-1/2) A E D 51mm (2 ) FIGURE 3 - STEAM COIL C B A F 2 34.9mm (1-3/8 ) COPPER CONN S. E G Coil 1HW0452 1 Unit 180 Hot Water Coil Dimensions mm (in.) A B C D E F G 1543 (60-3/4) 819 (32-1/4) 152 (6) 58 (2-5/32) 84 (3-5/16) 1. Installs between the coil and blower section of the unit. 98 170 (3-27/32) (6-11/16) D 502 2 FIGURE 4 - HOT WATER COIL Unitary Products Group 9

G E K C K F L 76 (3 ) 292 (11-1/2 ) H D A 1SP0452 H B 1SP 0452 38 (1-1/2 ) KNOCKOUT POWER FOR WIRING WITH ELECTRIC HEAT - Remove this 64mm (2-1/2 ) knockout and one of the 22.2mm (7/8 ) knockouts from the rear panel of the plenum. Remove the 43.7mm (1-23/32 ) knockout and one of the 22.2mm (7/8 ) knockouts from the top panel of the basic unit. Install a 12.7mm (1/2 ) squeeze connector in both of the 22.2mm (7/8 ) openings. Route the power wiring conduit through the 64mm (2-1/2 ) opening and connect it to the field-supplied fitting on the electric heat accessory. Connect the power wiring to the fuse block in the heater control box. Route the control wires through the 22.2mm (7/8 ) openings and connect them to the terminals on block TB1. Secure them with the 12.7mm (1/2 ) squeeze connectors. WITHOUT ELECTRIC HEAT - Remove both 22.2mm (7/8 ) knockouts from the rear panel of the plenum and both 22.2mm (7/8 ) knockouts from the top panel of the basic unit. Install a 12.7mm (1/2 ) squeeze connector in one of the plenum openings and both of the unit openings. Install a 12.7mm (1/2 ) conduit fitting in the other opening of the plenum. Connect the power wiring conduit to the fitting on the plenum. Route the power wiring through the conduit, one of the squeeze connectors on the unit, and the field-supplied squeeze connector on the blower motor contactor. Route the control wires through the remaining plenum and unit openings and connect them to the terminals on block 4TB. Secure them with the 12.7mm (1/2 ) squeeze connectors. Accessory Unit 1SP0452 180 Plenum Dimensions mm (in.) A B C D E F G H K L 1543 (60-3/4) 787 (31) 686 (27) 1695 (66-3/4) 505 (19-7/8) 156 (6-1/8) 25 (1) 64 (2-1/2) 495 (19-1/2) 44 (1-3/4) 10 Unitary Products Group

1 D L E F C 19 (3/4 ) HEATER ELEMENT CHAMBER A H B K G M ACCESS OPENING FOR POWER SUPPLY WIRING 10 kw thru 36kW - Add 32mm (1-1/2 ) conduit fitting to the 43.7mm (1-23/32 ) hole for wire sizes up through #1 AWG. Remove the knockout ring and add a 38mm (1-1/2 ) conduit fitting to the 50mm (1-31/32 ) hole for wire sizes up through #0 AWG. WIRING H ARNESS L OCATION This opening in the bottom of the heater control box is used for the wiring harness that connects the heater accessory to the basic unit. It is provided with a squeeze connector for securing the wiring harness, and its location corresponds to the location of the 43.7mm (1-23/32 ) knockout in the top panel of the basic unit. 13 (1/2 ) FIGURE 5 - ACCESSORY DIMENSIONS TABLE 12: ELECTRIC HEATER DIMENSIONS KEU180 Heater Nom. kw Heater Dimensions (inches) A B C D E F G H K L M 2HS04501050 2HS04501650 2HS04502650 2HS04503650 10 16 26 36 692 (27-1/4) 641 (25-1/4) 362 (14-1/4) 25 (1) 102 (4) 13 (1/2) 140 (5-1/2) 38 (1-1/2) 25 (1) 565 (22-1/4) 489 (19-1/4) 3 TABLE 13:ELECTRICAL DATA Blower Motor HP/kW Power Supply FLA MCA Max. Fuse 1 / Breaker 2 Size (Amps) 2.2 / 3 380/415-3-50 5.2 6.5 10 1. Dual element, time delay fuses. 2. HACR type per NEC. 3 TABLE 14:ELECTRICAL DATA WITH ELECTRIC HEAT Heater Nominal Heat Volt Heat FLA Motor FLA MCA Max. Fuse 1 / Breaker 2 Size (Amps) 10 kw 7.5 415 10.4 5.2 19.5 20 16 kw 12.0 415 16.6 5.2 27.3 30 26 kw 19.4 415 27.0 5.2 40.3 45 36 kw 26.9 415 37.4 5.2 53.3 60 1. Dual element, time delay type. 2. HACR type per NEC. Unitary Products Group 11

Subject to change without notice. Printed in U.S.A. Copyright by Unitary Products Group 2007. All rights reserved. Unitary Products Group 5005 York Drive 293759-XTG-A-0307 Supersedes: 262986/550.39-TG5YI (0601) Norman OK 73069