ESAC ebacgw Siemens. Date: Oct 15,2008. Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3. Product Description:

Similar documents
ESAC ebacgw Meteo. Date: Nov 25,2008. Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3. Product Description:

ESAC ebacgw Tecnoalarm

Delta ORCAview 3.40 BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT

Enterprise Buildings Integrator R500 Protocol Implementation

Document Introduction Annex A - Protocol Implementation Conformance Statement (Normative) Product Description... 4

C5 controller Bacnet

MRMS Multi-Room Monitoring Station

CS-RS. Remote Sensor User Manual

DESCRIPTION OF CONTROL

EBI R410 BACnet Direct Protocol Implementation Conformance Statement (PICS)

B. This Section includes DDC controls for Lighting system installed on the same operator interface as the HVAC controls.

TC Compact Series. Features. Description. Technical Specification Sheet Document No December 2, 2009

IMC BACnet Module. Service Literature. Table of Contents. General. Field Connections. Physical

PXC Modular Series for BACnet Networks

Compact Series Unitary Equipment Controller

FS20 / FS720 BACnet Protocol Implementation Conformance Statement (PICS) System Description

IAQPoint MONITEUR DE QUALITÉ DE L AIR INTÉRIEUR INDOOR AIR QUALITY MONITOR. Manuel d utilisateur User Manual

Houston Independent School District Design Guidelines Version 3.0 Revised August 2015 SECTION DIRECT DIGITAL CONTROLS

PIR Ready VT76xx Series Programmable & Non-Programmable Thermostats For Commercial HVAC Applications. BACnet Integration Manual September 1, 2010

Daikin Loop Water Manager Protocol Information

Fan Coil Controller. EFCB Series BACnet Communication Module User Guide. EFCB-BACnet Guide-EUA

BACnet Integration Manual ITG-VH72xx-BAC-E00 ( _R0 Issue Date: October 21, 2008)

IntesisBox BACnet/IP Server - Notifier ID3000 series

BACnet PTEC Controller VAV 0 to 10V Series Fan and 3- Stage Electric Heat, Application 6657

SECTION INTEGRATED AUTOMATION FACILITY CONTROLS

Design Standards Brief Section 9 Building Automation System and Automatic Controls

Manual for the integration in BMS/GTC

Table of Contents. i-vu CCN Standard 4.2

FieldServer Driver - Serial FS SBT-FSI (Siemens Building Technologies Foreign Systems Interface)

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

MicroTech III Applied Air Handling Unit Controller Protocol Information

MEPF SPECIFICATIONS SECTION ELECTRICAL GENERAL PROVISIONS SECTION BASIC MATERIALS AND METHODS. MFE MEPF Specification Index Index - 1

Introduction. Introduction

RESPONSES TO BIDDERS QUESTIONS:

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

FS Mircom FX2000 Fire Alarm Panel

CONSTRUCTION SYSTEMS AND ASSEMBLIES

SECTION INSTRUMENTATION AND CONTROLS FOR HVAC

Metasys System Extended Architecture Fire System Integration Using the IFC BACnet Gateway

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

MicroTech III Rooftop and Self Contained Unit Controller Protocol Information

Niagara4 Technical Certification Program Student Guide DAY 1 DAY 2

ONYXWORKS AND FIRSTVISION. Version 4

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls

UNC100 Integra Manual

CONTROL OF HVAC

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

Document # R01

Multistate Alarm. Introduction

Building Automation System (BAS) Design Criteria

SAUTER ecos504/505. The modular room controller for demand-controlled, integral room automation.

SEQUENCE OF OPERATIONS

Scotch Plains, New Jersey SECTION DIRECT DIGITAL CONTROL (DDC) SYSTEM FOR HVAC

I/O ZONE 560/583 USERS GUIDE

Alarm Handling Subsystem (AHS) Requirements Specification. Enterprise Building Management System (EBMS)

Product Datasheet MM8000 MP3.10 Management Station

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

Building Management System

Alarm module for leak detection with webserver

Platform Services BACnet Alarm Management

opti-visor ultra-efficient chiller plant automation Typical specification

F Technical Bulletin SC 370 SMART Modbus Interface

Introduction. What is the W2W Open controller?

Carbon Monoxide Transmitter

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

D-Link Central Management System

Liebert SiteScan Web. Modbus and BACnet Protocols. Installer/User Guide

Building Technologies

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Lift Station Level Controller

COCB_ Circuit Breaker (2 state inputs/ 2 control inputs)

Added password for IP setup page : Password must be in IP format!

Automation System TROVIS 5400 Ventilation Controller TROVIS Mounting and Operating Instructions EB 5477 EN. Electronics from SAMSON

Call stations and extensions

Avigilon Control Center System Integration Guide

CATALOG NUMBER. Features. Description

i-vu CCN 4.0 Owner s Guide

FlameGard 5 UV/IR HART

SECTION DIRECT-DIGITAL CONTROL SYSTEM FOR HVAC

GMS GRAPHICAL MANAGEMENT SYSTEM

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

NETWORKING AND INTEGRATION

Avigilon Control Center System Integration Guide

DUVAL COUNTY PUBLIC SCHOOLS ENERGY MANAGEMENT CONTROL SYSTEMS (EMCS) PART 1 - GENERAL 1.1 SCOPE OF WORK

HEGA Ethernet Gateway Browser Interface Guide

BUILDING AUTOMATION CONTROLS SYSTEM

ICC INDUSTRIAL CONTROL COMMUNICATIONS, INC.

FieldServer Driver - Serial FS McQuay Microtech Open Protocol

RPM1600 Series Room Pressure Monitors

Integrated Security Solutions

(Formerly SECTION BACNET BUILDING AUTOMATION SYSTEM DIRECT DIGITAL CONTROLS GUIDE SPECIFICATION) CONTENTS

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Model A1700 Series Annunciator

V10 Controller - BACnet lnterface Supplement 1

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

Universal Monitoring System. TrapServer Description

ETSI TS V8.2.0 ( ) Technical Specification

C-TRAC3 COMMUNICATION MANUAL FOR. BACnet NOVEMBER 2010 TO JANUARY 2014 USA HEAD OFFICE AND FACTORY

Transcription:

Date: Oct 15,2008 Vendor Name: ESAC srl Product Name: ebacgw-siemens Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3 Product Description: ebacgw is a BACnet gateway to Siemens WSM thermal energy meters; based on a high reliability 32 bit architecture, automatic configuration detection allows the device to operate with minimal user effort for configuration. The following items of each meter can be controlled via BACnet: operating hours outlet temperature inlet temperature thermal gradient flow volume energy power BACnet Standardized Device Profile (Annex L): BACnet Operator Workstation (B-OWS) BACnet Building Controller (B-BC) (except DM-DOB-A) BACnet Advanced Application Controller (B-AAC) BACnet Application Specific Controller (B-ASC) BACnet Smart Sensor (B-SS) BACnet Smart Actuator (B-SA) Oct,15 2008 (rev 1.0) SUBJECT TO CHANGE page 1 of 6

s Supported (Annex K): Data Sharing Data Sharing-ReadProperty-A (DS-RP-A) Data Sharing-ReadProperty-B (DS-RP-B) Data Sharing-ReadPropertyMultiple-A (DS-RPM-A) Data Sharing-ReadPropertyMultiple-B (DS-RPM-B) Data Sharing-ReadPropertyConditional-A (DS-RPC-A) Data Sharing-ReadPropertyConditional-B (DS-RPC-B) Data Sharing-WriteProperty-A (DS-WP-A) Data Sharing-WriteProperty-B (DS-WP-B) Data Sharing-WritePropertyMultiple-A (DS-WPM-A) Data Sharing-WritePropertyMultiple-B (DS-WPM-B) Data Sharing-COV-A (DS-COV-A) Data Sharing-COV-B (DS-COV-B) Data Sharing-COVP-A (DS-COVP-A) Data Sharing-COVP-B (DS-COVP-B) Data Sharing-COV-Unsolicited-A (DS-COVU-A) Data Sharing-COV-Unsolicited-B (DS-COVU-B) Scheduling Scheduling-A (SCHED-A) Scheduling-Internal-B (SCHED-I-B) Scheduling-External-A (SCHED-E-B) Trending Trending-Viewing and Modifying Trends-A (T-VMT-A) Trending-Viewing and Modifying Trends-Internal-B (T-VMT-I-B) Trending-Viewing and Modifying Trends-External-B (T-VMT-E-B) Trending-Automated Trend Retrieval-A (T-ATR-A) Trending-Automated Trend Retrieval-B (T-ATR-B) Network Management Network Management-Connection Establishment-A (NM-CE-A) Network Management-Connection Establishment-B (NM-CE-B) Network Management-Router Configuration-A (NM-RC-A) Supported Oct,15 2008 (rev 1.0) SUBJECT TO CHANGE page 2 of 6

Network Management-Router Configuration-B (NM-RC-B) Alarm and Event Management Alarm and Event-Notification-A (AE-N-A) Alarm and Event-Notification Internal-B (AE-N-I-B) Alarm and Event-Notification External-A (AE-N-E-B) Alarm and Event-ACK-A (AE-ACK-A) Alarm and Event-ACK-B (AE-ACK-B) Alarm and Event-Alarm Summary-A (AE-ASUM-A) Alarm and Event-Alarm Summary-B (AE-ASUM-B) Alarm and Event-Enrollment Summary-A (AE-ESUM-A) Alarm and Event-Enrollment Summary-B (AE-ESUM-B) Alarm and Event-Information-A (AE-INFO-A) Alarm and Event-Information-B (AE-INFO-B) Alarm and Event-LifeSafety-A (AE-LS-A) Alarm and Event-LifeSafety-B (AE-LS-B) Device Management Device Management-Dynamic Device Binding-A (DM-DDB-A) Device Management-Dynamic Device Binding-B (DM-DDB-B) Device Management-Dynamic Object Binding-A (DM-DOB-A) Device Management-Dynamic Object Binding-B (DM-DOB-B) Device Management-DeviceCommunicationControl-A (DM-DCC-A) Device Management-DeviceCommunicationControl-B (DM-DCC-B) Device Management-Private Transfer-A (DM-PT-A) Device Management-Private Transfer-B (DM-PT-B) Device Management-Text Message-A (DM-TM-A) Device Management-Text Message-B (DM-TM-B) Device Management-TimeSynchronization-A (DM-TS-A) Device Management-TimeSynchronization-B (DM-TS-B) Device Management-UTCTimeSynchronization-A (DM-UTC-A) Device Management-UTCTimeSynchronization-B (DM-UTC-B) Device Management-ReinitializeDevice-A (DM-RD-A) Device Management-ReinitializeDevice-B (DM-RD-B) Supported Oct,15 2008 (rev 1.0) SUBJECT TO CHANGE page 3 of 6

Device Management-Backup and Restore-A (DM-BR-A) Device Management-Backup and Restore-B (DM-BR-B) Device Management-List Manipulation-A (DM-LM-A) Device Management-List Manipulation-B (DM-LM-B) Device Management-Object Creation and Deletion-A (DM-OCD-A) Device Management-Object Creation and Deletion-B (DM-OCD-B) Device Management-Virtual Terminal-A (DM-VT-A) Device Management-Virtual Terminal-B (DM-VT-B) Supported Segmentation Capability: Segmented Requests Supported Window Size: - Segmented Responses Supported Window Size: 1 Standard Object Types Supported: Object-Type Supported Optional Properties Supported Writable Properties Analog Input Analog Output Analog Value Description,Reliability, Priority Array, Relinquish Default, Notification Class, High Limit, Low Limit, Deadband, Limit Enable, Event Enable, Notify Type, Time Delay Averaging Binary Input Binary Output Binary Value Description, Reliability Active Text, Inactive Text, Priority Array, Relinquish Default, Time Delay, Notification Class, Alarm Value, Event Enable, Notify Type Object Name, Description, Reliability, Out of Service,Notification Class, High Limit, Low Limit, Deadband, Limit Enable, Event Enable,Notify Type, Time Delay, Relinquish Default, Priority Array Object Name, Description, Present Value, Reliability, Active Text, Inactive Text, Pririty Array, Relinquish Default, Time Delay, Event Enable, Notify Type Oct,15 2008 (rev 1.0) SUBJECT TO CHANGE page 4 of 6

Calendar Commad Device YES Description, Location, APDU Seg Timeout, Local Time, Local Date Status Object Name, Description, Location, Local Time, Local Date Event Enrollment File Group Life Safety Point Life Safety Zone Loop Multi-state Input Multi-state Output Multi-state Value Notification Class Description Object Name Description Priority Recipient List Program Schedule Trend Log Data Link Layer Options: BACnet IP, (Annex J) BACnet IP, (Annex J), Foreign Device ISO 8802-3, Ethernet (Clause 7) (10Base2, 10Base5, 10BaseT, Fiber) ANSI/ATA 878.1, 2.5 Mb. ARCNET (Clause 8) ANSI/ATA 878.1, RS-485 ARCNET (Clause 8), baud rate(s): MS/TP master (Clause 9), baud rate(s): 9600, 19200, 38400, 76800 MS/TP slave (Clause 9), baud rate(s): Point-To-Point, EIA 232 (Clause 10), baud rate(s): 9600, 19200, 38400 Point-To-Point, modem, (Clause 10), baud rate(s): 9600, 19200, 38400 LonTalk, (Clause 11), medium: Other: Intelli-Net (Coax) Device Address Binding: Is static device binding supported? Yes No (Necessary for two-way communication with MS/TP slaves and certain other devices.) Oct,15 2008 (rev 1.0) SUBJECT TO CHANGE page 5 of 6

Networking Options: Router Annex H, BACnet Tunnelling BACnet/IP Broadcast Management Device (BBMD) Does the BBMD support registrations by Foreign Devices? Character Sets Supported: Indicating support for multiple character sets does not imply that they can all be supported simultaneously. ANSI X3.4 IBM/Microsoft DBCS JIS C 6226 ISO 10646 (ICS-4) ISO 10646 (UCS2) ISO 8859-1 If this product is a communication gateway, describe the types of non-bacnet equipment/networks(s) that the gateway supports: This gateway fully supports the m-bus protocol used by Siemens WSM meters Oct,15 2008 (rev 1.0) SUBJECT TO CHANGE page 6 of 6