Similar documents
SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

First Alert 1200C Installer Notes M. Leuck

VISTA-100 Commercial Fire & Burglary Partitioned System

Contact ID as of 11/28/2018

Contact ID as of 2/2/2015

INSTALLATION INSTRUCTIONS and OPERATING GUIDE


INSTALLATION INSTRUCTIONS

CC408. Quick Reference Guide Solution 880

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

CONTACT ID REPORT CODES

RE6100 Series Helix Security and Automation Platform

Independent Zone Control (I.Z.C.)

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

2000 Series. Program Entry Guide. Control Panels

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

NESS 5000 SERIES DIALLER

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

Release Notes for Version 7.05 January 2007

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

Safewatch Pro 3000 System Manual

Solution-8248 Installation Manual ISSUE 1.16

8-zone Expansion Module

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

CC488. Quick Reference Guide Solution Ultima 880

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

installation & operation manual

ADEMCO CONTACT ID REPORTING (revised )

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

ERS-3600B. PERS-3600B Personal Emergency Reporting System

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

Your Ademco. Fir&Burglar Alarm System. LogiCenter INTRODUCTION: ALARM DEVICE MANUFACTURING CO.

Property of Monitronics Inc

EVO192 v3.0 Fire and Burglary What s New

VISTA-128FB. Quick Start Guide. Commercial Fire & Burglary Partitioned Security System. with Scheduling.

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

Control/Communicator

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

XRSuper6. User s Guide

Programming Worksheets

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

Property of Monitronics Inc

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Solution 880 Operators Manual. Issue 1.00

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Digital Communication Standard - Ademco Contact ID Protocol - for Alarm System Communications

Commercial Fire and Burglary Partitioned Security System with Scheduling

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

VISTA-128B. Installation and Setup Guide. Commercial Burglary. Partitioned Security System. with Scheduling K3271 7/98

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

Solution 862 Installation Manual ISSUE 1.30

Area Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.

GEM-P801 Control Panel/Communicator For use with the GEM-RP8 or the GEM-K800 Keypads. Installation Instructions

All-In-One Wireless Security System V1.0. Model # MG Programming Guide

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

VISTA-50P VISTA-50PUL

Fire Command Center. XR2400F User s Guide

AdvisorOne Quick Operation Guide

INSTRUCTION MANUAL PC255O

Solution 6+6 Wireless - AE Operators Manual ISSUE 1.10

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual

Figure 1. These Installation Instructions -1- K4866 4/00 OmniProx Reader Model Series OP-10/20/30/40

External Wireless Sounder

INSTRUCTION MANUAL PC255O

System Programming Guide

How to Use Your Sentrol Security System

AXI LED USER MANUAL (REV. 1.0)

VISTA-40. Installation and Setup Guide. 2-Partition Security System N7001V4 7/98

User's Manual 5120XM N8031 6/96

Solution Ultima 862 Operators Manual ISSUE 1.10

Version 1.03 January-2002 USER S MANUAL

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

V2 1/13 Rev C

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

Security System. User Guide for the LED Command Center

GEM-P800. Control Panel/Communicator. Installation Instructions

Radionics D4112 Program Sheet

Condominium Security Management System

4-PGM Expansion Module

GV2 Series Control Panels

FBII Security System. Programming Guide. Version 2.X. N9967PRV3 4/04 Rev. A

Dear Tech-Man Subscriber:

How to Use Your Sentrol Security System

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Transcription:

ADDENDUM TO: RE: INSTALLATION INSTRUCTIONS FOR 5140XM CONTROL USE WITH ISSUE: N6019V1 Feature Changes and New Program Fields This addendum applies to 5140XM Controls which are shipped with firmware EPROM marked: WA5140XM-XX (where XX = 18 or higher) The EPROM is located beneath the main PC board shield cover. The following features are new for the 5140XM Control. 1. In accordance with revisions to UL864, Standard for Commercial Fire Alarms, the following system changes have been made. Silencing Console Sounds for Fire Supervisory Zone Type now requires security code + OFF To silence console sounds triggered by supervisory conditions on zones programmed for fire zone supervisory response (zone response type 18), you must enter the security code + OFF. Prior to this change, these console sounds could be silenced by pressing any key (no security code was needed). Keyswitch Mode 2 Operation (field *15) New fire or burglary alarm conditions occurring after a previous alarm was silenced using the keyswitch will now automatically re-activate the corresponding fire or burglary alarm bell circuits when keyswitch mode 2 operation is selected (field *15 set to 2). Prior to this change, alarm bell circuits remained silenced until the security code + OFF was entered at a console. Note that when keyswitch mode 2 operation is selected, operating the keyswitch will silence fire and burglary alarms only when a fire alarm condition is present (in accordance with the existing Installation Instructions). OFF-NORMAL Communicator Test Report (new program fields 3*53, 3*54) Off-normal conditions are fire alarm system related conditions existing at the time a normal test report is sent. These conditions include fire alarms, fire troubles or supervisories, and certain system troubles such as earth ground faults, AC failure, low system battery, or bell circuit faults. The 5140XM now transmits an "off-normal" communicator test report (programmed in field 3*53, 3*54) instead of the normal communicator test report (programmed in fields *81, *82) when fire alarm system offnormal conditions are present at the time of test report transmission. As shipped, both reports are disabled and must be enabled for installations that provide fire alarm central station service. The normal communicator test report is enabled as described in the Installation Instructions. The off-normal communicator test report is enabled as follows: Field 3*53 Field 3*54 First Digit Second Digit For Ademco High Speed and Ademco Contact ID report formats: Enter "01" in field 3*53. Ademco High Speed off-normal test reports use channel 3 =1 and status channel = 9 Contact ID sends code 608. For Low Speed Formats: Enter the first (event code) digit of the report in field 3*53 and the second (zone number) digit of the report in field 3*54. These fields require that two numbers be entered for each digit of the report (i.e. enter 00 if no digit is to be sent, enter 01 for "1", enter 10 for "A"..., enter 15 for "F"). Note: fields 3*53 and 3*54 can also be programmed by loading one of the four built-in communication defaults as follows: Communicator Default 3*53 Value 3*54 Value Low Speed (*94*80) 05 00 Ademco Express (*94*81) 15 00 Ademco High Speed (*94*82) 01 00 Ademco Contact ID (*94*83) 01 00

2. Fire Supervisory Response On Short Circuit Or Open Circuit Selection (new program field 3*13) Field 3*13 allows the installer to select whether a short circuit or open circuit fault will initiate a supervisory response on zones programmed for fire supervisory response (response type 18). 3*13 0 = trouble on open / supervisory on short; 1 = supervisory on open / supervisory on short When field 3*13 is set to "0" (default), zones programmed for fire supervisory response provide trouble on open / supervisory on short. When field 3*13 is set to "1", zones programmed for fire supervisory response provide supervisory on open / supervisory on short response. 3. Extended waterflow and fire supervisory delay (new program field 3*18) Field 3*18 allows the fire waterflow (response type 17) and fire supervisory (response type 18) zone delay programmed in field 3*16 to be extended. 3*18 0 = no extended delay; 1 = delay in 3*16 times 4 When field 3*18 is set to "0" (default), the delay programmed in field 3*16 applies. When field 3*18 is set to "1" the delay programmed in field 3*16 is multiplied by 4 (allowing delays up to 120 seconds). 4. Manual/Automatic fire Waterflow alarm silencing (new program field 3*14) Field 3*14 allows the installer to select whether zones programmed for fire waterflow response (response type 17) can be silenced manually (security code + OFF) or can be silenced automatically when waterflow ceases. 3*14 0 = manual silencing only; 1 = automatic silence when waterflow ceases When field 3*14 is set to "0" (default), waterflow zones can be silenced manually only, by entering the security code + OFF. When field 3*14 is set to "1", waterflow zones will silence automatically when waterflow ceases (provided that no other fire alarms are present). Note that if field 3*14 is set for "1", entering security + OFF will not silence waterflow alarms while water continues to flow. 5. Clarification of Duress Trigger Operation The Installation Instructions currently state that the silent panic/duress trigger goes HIGH when a silent panic or duress alarm occurs, and remains high until the security code + OFF is entered. This is true when a silent panic alarm is initiated via a hardwired or polling loop zone. However, if the duress alarm is initiated via console key depression, the silent panic/duress trigger remains high for about 2 seconds only, then returns to the low state. N6019V1XX 12/94 ALARM DEVICE MANUFACTURING CORPORATION A DIVISION OF PITTWAY CORPORATION 165 Eileen Way, Syosset, New York 11791 Copyright 1994 PITTWAY CORPORATION