REFRIGERATED CONDIMENT RAIL

Similar documents
HOT FOOD HUMIDITY CABINET

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 2M-Z3755 Rev. J 10/26/11 175CBA.

ELECTRIC GRIDDLES TMGE24, TMGE36, TMGE48. Installation and Operation Instructions 2M-Z12971 Rev. - Oct. 1, 2009 MODEL TMGE36 IL1880

Electric Cruise Line Single Broiler w/ Cabinet Base CLB V CLB V

OPERATIONS MANUAL INCLUDES INSTALLATION, USE, CARE, SERVICE AND DIAGRAMS.

Electric Cruise Line Double Broiler w/ Oven Base CLB36S-2-440V CL36B2OLF440

ULTRA-MAX GAS RADIANT CHARBROILER. ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBB, 8036CBB, 8048CBB, 8060CBB, and 8072CBB

IRCS2-SBD Conveyor Toasters

STANDARD FRYERS COUNTERTOP MODELS F-14 F-49 F-55 F-67 F-85 F-1725 OPERATION MANUAL. Includes INSTALLATION USE & CARE

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 175CBA. 2M-Z3755 Rev. L 10/01/2015.

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

CONVEYOR TOASTER MODEL QCS QCS Installation and Operation Instructions 2M-HG0657 Rev. D 6/13/05

OPERATION MANUAL COUNTERTOP ELECTRIC CHAR BROILERS. for. Models: B-40 B-44 B-50. includes: INSTALLATION, USE and CARE

Operators and Service Manual

STAR-MAX PROPANE GAS GRIDDLE

HOT FOOD HUMIDITY CABINET

DRAWER ROLL/ BUN WARMER

Hot Plate-Style Decanter Warmer

Product Identification

OWNER S MANUAL MODELS AP8, AP8B, AP8C, AP8D DUMP STATION HEATER

011D OWNERS MANUAL. BUILT-IN ROUND WELL WARMERS (Insulated & Non-Insulated) with THERMOSTAT CONTROL

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

HOT FOOD HUMIDITY CABINET

RW1HD RW2HD RW3HD RWN1 RWN2 RWN3

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 2M-Z3755 Rev. J 10/4/06 175CBA.

WELLS COUNTERTOP 6411 & LL Series SOUP COOKERS and COOK N HOLD WARMERS

Outdoor Beverage Center

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

CRISP N HOLD FRIED FOOD HOLDING CABINET MODELS: CNH14, CNH18, CNH28, CNH40 OWNERS / OPERATORS MANUAL

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

012D SS4, SS4D SS8, SS8D SS10, SS10D OWNERS MANUAL. DROP-IN ROUND-WELL WARMERS with INFINITE SWITCH CONTROL MODELS

CNH12LP CNH28 CNH40 CNH28LPC

Installation, Operation, Maintenance, & Troubleshooting Model: CLS36-440V Electric Cruise Line Salamander Serial:

Hot Dog Hutch. Models HDH-3, HDH-3DR, & HDH-4 owner s manual. Manufacturing Numbers:

SERVICE MANUAL Undercounter Refrigerator Drawer Units

INSTALLATION & OPERATION MANUAL

Owner s Manual WARMER DRAWER. (Without Water Tray) Models WD-20, WD21A, & WD-35A. WD-20 Shown MANUFACTURING NUMBERS: P/N Rev.

INSTALLATION & OPERATION MANUAL

OWNERS MANUAL. WELLS COUNTERTOP WARMERS with THERMOSTAT CONTROL MODELS SMPT, SMPTD SMPT27, SMPTD27 SW10T TMPT, TMPTD

Drop-In Induction Range

INSTALLATION & OPERATION MANUAL

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

MANUFACTURING NUMBERS: CORN CAROUSEL. Model CC-19 Series P/N /99. Owner s Manual

OPERATING INSTRUCTIONS

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Insta-Therm Series Service, Installation and Operation Manual

INSTALLATION & OPERATION MANUAL

OWNER S MANUAL MODEL BW4B SLICER WARMER

HOT FOOD HUMIDITY CABINET

Service Manual Models CPH2 & CPH3

WELLS BUILT-IN HW-Series COOK N HOLD WARMERS with THERMOSTAT CONTROL

INSTALLATION & OPERATION MANUAL

Instruction Manual. Bottle Cooler. Models HBC-50 (-S) HBC-65 (-S) HBC-80 (-S) HBC-95 (-S) hoshizakiamerica.com. Issued: Revised:

INSTALLATION & OPERATION MANUAL

User Manual. Commercial School Milk Cooler User s Manual. Commercial School Milk Coolers: MC34, MC49, MC58

SERIES NAV S Display Merchandisers

User Manual. Wine Cellar

012B OWNERS MANUAL. DROP-IN and BOTTOM-MOUNT UNSHROUDED WARMERS with INFINITE SWITCH CONTROL MODELS SS206(D) SS206E(D) SS206ER(D)

Instruction Manual Item No.: V~, 60Hz

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

Hot Water Dispensers HWD2, HWD3, HWD5. Table of Contents

Operation Manual and Parts Directory

InstructIon Manual KrEs EQuIPMEnt stands

User s Manual Warm N Cozy

B.I.C.A Built-In Coffee Appliance

INSTALLATION & OPERATION MANUAL

INSTRUCTIONS. Installation, operation and care of HD SERIES HOT DELI DISPLAY CASES. MODEL HD5 Full-Service IMPORTANT READ BEFORE USING DISPLAY CASE

User Manual. Commercial Refrigerator And Freezer User s Manual

OWNER'S MANUAL. FRY Holding Unit (FHU) MODELS FHU1 FHU2. Duke Manufacturing Company

MODEL 721 ELECTRICAL DATA: FEATURES: ACCESSORIES: DIMENSIONS: SHIPPING INFORMATION: CONVECTION OVEN 1/2 SIZE PAN

DIGITAL QUARTZ INFRARED HEATER. Model No.: SPP1500SBH

BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions

BOTTLE COOLERS SLIDE TOP INSTALLATION AND OPERATION INSTRUCTION MANUAL MODEL SERIES BC24- BC36- BC48- BC72- BC96-

Use and Care Manual. For Beverage Cooler RU

Condiment Warmer. Instruction Manual Models #2252EX & #2253EX. Cincinnati, OH USA. Model #2252EX. Model #2253EX

HEAT-XPRESS FINISHING CABINET OWNER/OPERATOR MANUAL

OWNERS MANUAL for HOT WATER DISPENSER FOR EXPORT 2 GALLON MODELS: G-230V 5 GALLON MODELS: G-230V. Includes:

OWNER S MANUAL REFRIGERATED MERCHANDISER INSTALLATION AND OPERATION ENGLISH RFM HG-ADA RFM HG RFM HG RFM HG

STAR-MAX GAS GRIDDLES MODELS 615MA 624MA 636MA 648MA 615TA 624TA 636TA 648TA 624TSPA 636TSPA 648TSPA

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

INSTALLATION & OPERATION MANUAL

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Outdoor Beverage Center

HT-MOSEL-51D PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THE WINE CHILLER

Technical Manual and Replacement Parts List. Cream Dispenser

WV-FG SERIES OWNERS MANUAL. GRIDDLE / FRYER COOKTOP with UNIVERSAL HOOD MODELS WV-FG WV-FGRW

COMBINATION HOT DOG STEAMER & BUN WARMER

HA SERIES. CVap Holding Cabinet Owner s Manual

VERTICAL CONTACT TOASTER

STANDARD FRYERS COUNTERTOP MODELS F14 F49 F55 F67 F85 F1725 OWNERS MANUAL. Includes INSTALLATION USE & CARE EXPLODED VIEW PARTS LIST WIRING DIAGRAM

SOUP COOKER/WARMER 120V, 240V MODEL 6423 INSTRUCTIONS. Installation Operation Maintenance

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

DOUBLE DOOR COMPACT REFRIGERATOR. User Manual MODEL:KSTRC312BW KSTRC312BB

12,000 BTU Evaporative Portable Air Conditioner

Thermal Electric Wine & Beverage Chiller Model: WC-2463W. Instruction Manual

INFRARED ZONE HEATING SYSTEM

INSTALLATION & OPERATION MANUAL

Installation and User's Manual for Refrigerator Model SCR33

Transcription:

REFRIGERATED CONDIMENT RAIL MODEL RCR-4 Installation and Operation Instructions 2M-Z19984 Rev. - 2/13/15 RCR-4

SAFETY SYMBOL These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance. RETAIN THIS MANUAL FOR FUTURE REFERENCE NOTICE Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability. Star reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment. Due to periodic changes in designs, methods, procedures, policies and regulations, the specifications contained in this sheet are subject to change without notice. While Star International Holdings Inc., Company exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications. By using the information provided, the user assumes all risks in connection with such use. MAINTENANCE AND REPAIRS Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when you call to ensure a faster service. Model No. Serial No. Voltage Purchase Date Authorized Service Agent Listing Reference the listing provided with the unit or for an updated listing go to: Website: E-mail www.star-mfg.com Service@star-mfg.com Service Help Desk Business 8:00 am to 4:30 p.m. Central Standard Time Hours: Telephone: (314) 678-6303 Fax: (314) 781-2714 E-mail Website: Parts@star-mfg.com Service@star-mfg.com Warranty@star-mfg.com www.star-mfg.com Mailing Address: Star International Holdings Inc., Company 10 Sunnen Drive St. Louis, MO 63143 U.S.A

ELECTRICAL SPECIFICATIONS Model No Voltage Watts HP Amps Ph Power Supply Refrigerant RCR-4 120V 240 1/6 2 1 NEMA 5-15P 134A GENERAL INSTALLATION INSTRUCTIONS This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. Before using your new equipment, read and understand all the instructions & labels associated with the unit prior to putting it into operation. Make sure all people associated with its use understand the units operation & safety before they use the unit. All shipping containers should be checked for freight damage both visible and concealed. This unit has been tested and carefully packaged to insure delivery of your unit in perfect condition. If equipment is received in damaged condition, either apparent or concealed, a claim must be made with the delivering carrier. Concealed damage or loss - if damage or loss is not apparent until after equipment is unpacked, a request for inspection of concealed damage must be made with carrier within 15 days. Be certain to retain all contents plus external and internal packaging materials for inspection. The carrier will make an inspection and will supply necessary claim forms. Any procedure which requires the use of tools must be performed by a qualified technician. These refrigerated condiment rails are equipped for the voltage and wattage indicated on the nameplate. These units are designed to operate on alternating current (AC) only. DO NOT CONNECT TO DIRECT CURRENT (DC). AGENCY LISTING INFORMATION This appliance is U Listed under UL File SA12649 for 120VAC 60Hz only. WARNING All servicing requiring access to non-insulated electrical components must be performed by a factory authorized technician. DO NOT open any access panel which requires the use of tools. Failure to follow this warning can result in severe electrical shock. 1

FEATURES & BENIFITS NAMEPLATE ON/OFF SWITCH POWER CORD REAR VIEW 15.125 (4) 1/6 PANS (INCLUDED) 1/6 1/6 25.5 S/S PAN DIVIDER (INCLUDED) 1/6 1/6 12 OPN'G CLEARANCE 1 SIDE & REAR TOP VIEW FRONT VIEW 10.5 SIDE VIEW 1/3 1/3 1/6 1/6 1/9 1/9 1/9 2/3 1/3 1/6 1/6 1/9 1/9 1/9 1/9 1/9 1/9 VARIOUS OTHER PAN ARRANGEMENTS (PANS BY OTHERS) OPTIONAL S/S NIGHT COVER IL2877 2

INSTALLATION UNPACKING & INSPECTION Carefully remove the appliance from the carton. Remove all protective plastic film, packing materials and accessories from the Appliance before connecting electrical power or otherwise performing any installation procedure. Carefully read all instructions in this manual and the Installation Instruction Sheet packed with the appliance before starting any installation. Read and understand all labels and diagrams attached to the appliance. Carefully account for all components and accessories before discarding packing materials. Store all accessories in a convenient place for later use. IMPORTANT This unit should NEVER be positioned upside down or on its side. If the unit arrived or was stored in any position other that THIS END UP as marked on the shipping container, then allow the unit to set upright 24 hours before applying power or turning on the unit. Failure to do this will cause the unit to function incorrectly. The unit will not be able to cool to the desired temperature. COMPONENTS 4 ea 1/6 PANS SET-UP NOTES 1. Setup the appliance only on a firm, level, non-combustible surface. Verify local codes for requirements. Concrete, tile, terrazzo or metal surfaces are recommended. Metal over combustible material may not meet code for non-combustible surfaces. 2. The adjustable legs come installed from the factory, with a spirit level, check that the appliance is level front-to-back and side-to-side. Verify that the unit sits firmly ON ALL FOUR LEGS. 3. The lower portions of the legs are adjustable by turning; adjust as required to level the appliance. All four legs must be adjusted to firmly contact the counter. 4. Avoid storing flammable or combustible materials in, on or near the appliance. ELECTRICAL HOOK-UP 1. Refer to the nameplate. Verify the electrical service power. Voltage and phase must match the nameplate specifications. Plugging the warmer into the wrong voltage can severely damage the unit or cause noticeable decreased performance. 2. Your unit is equipped with a grounded electrical cord. This cord must be plugging into a properly grounded electrical receptacle. Installation procedures must be performed by a qualified technician with full knowledge of all applicable electrical and plumbing codes. Failure can result in personal injury and property damage. WARNING This appliance must be plugged into a properly grounded receptacle. Contact a licensed electrician to install and connect a proper receptacle. Damage due to being connected to the wrong voltage or phase is NOT covered by warranty. 3

OPERATION SUGGESTIONS: Inspect each pan insert for thorough cleaning. Additional hand cleaning may be necessary to insure complete food removal. If detergent is used, items must be rinsed with clean water prior to use. PRE-CHILLING THE SERVER 1. Turn power switch on. 2. Place desired pan(s) or inset(s) with appropriate adapter top on server. 3. Allow unit to run for approximately 30 minutes OPERATION 1. Always use an inset. DO NOT place food directly into the server. 2. DO NOT use metal tools, steel wool, or caustic or abrasive cleanser to any metal surface on the unit. DO NOT put water or ice in the well of the server. CLEANING INSTRUCTIONS PREPARATION Turn power switch OFF Unplug from electrical power Remove Removable Pans FREQUENCY Daily, or as needed TOOLS Bottle Brush, Soft Bristle Brush Soft Cloth or Sponge CLEANING 1. Turn power switch OFF and unplug unit. 2. Remove (optional) cover., clean using warm water and mild detergent. 3. Remove pans and pan support, clean using warm water and mild detergent. 4. Clean the stainless steel using mild detergent, warm water and soft cloth or sponge. Dry using a clean cloth. DO NOT use any abrasive pads or wire brushes. Procedure is complete. WARNING Turn power switch OFF and disconnect unit from electric power before cleaning. NEVER use any corrosive cleaners, use only cleaners approved for stainless steel. 4

TEMPERATURE ADJUSTMENT TEMPERATURE ADJUSTMENT RCR-4 1. The temperature has been preset at the factory to meet most applications. 2. If temperature adjustments are required, the pressure switch, located on the condensing unit, is adjustable. Temperature adjustment must be performed by a qualified refrigeration personnel only. 3. Normal temperature setting would be 28ºF. LCD READOUT SET KEY KEY (INCREASE) The LCD Display provides a readout of the KEY (DECREASE) sensor temperature during normal operation. Use the following to change the set-point temperature: 1. To start programming, press SET key once. This will access the Fahrenheit/ Celsius mode. The readout will show the current status, either F (degrees Fahrenheit) or C (degrees Celsius). Press either up arrow (é) or down arrow (ê) to toggle between F and C designation. IL2878 2. Press SET again to access the set-point. The LCD will display the current set-point, and the S1 annunciator will blink off and on to indicate that control is in the set-point mode. Press either up arrow (é) to increase the set-point, or down arrow (ê) to decrease the setpoint to the desired temperature. Factory set-point is 21ºF. DO NOT adjust the differential settings of the refrigeration system. Field adjustments of the differential settings must be made by qualified refrigeration personnel only. Unauthorized adjustment of the differential settings will void the warranty. The temperature setting of the NSF-7 Refrigerated Cold Pan has been pre-set at the factory to meet most applications. An electronic temperature control maintains food temperature between 33ºF and 44ºF. 3. Press the SET key again to access the differential. The LCD will display the current differential, and the DIF1 annunciator will blink off and on to indicate that control is in the differential mode. DO NOT adjust the differential settings of the refrigeration system. Field adjustments of the differential settings must be made by qualified refrigeration personnel only. Unauthorized adjustment of the differential settings will void the warranty. Press either up arrow (é) to increase the differential, or down arrow (ê) to decrease the differential to the desired setting. Factory differential is 3ºF. 4. Press the SET key again to access the Heating / Cooling mode. The LCD will display the current mode. Either C1 for cooling or H1 for heating. The control must be set to C1 for proper operation of the cold pan. 5. Press the SET key again to complete programming. Programming ends automatically if no keys are pressed for 30 seconds. Any settings that have been input to the control will be accepted at that time. 5

TEMPERATURE ADJUSTMENT continued 6. Control settings are stored in non-volatile memory. Loss of power to the unit will not require reprogramming. DO NOT adjust the differential settings of the refrigeration system. Field adjustments of the differential settings must be made by qualified refrigeration personnel only. Unauthorized adjustment of the differential settings will void the warranty. NOTE: The controller has both heating and cooling modes. Heating mode is not used on the RCTS-series units. The control must be set to cooling (C1) for proper operation of the cold pan. TROUBLESHOOTING SYMPTOM PROBABLE CAUSE SUGGESTED REMEDY No power to unit Unit unplugged or circuit breaker tripped Plug unit into appropriate receptacle Reset circuit breaker Power switch off Turn switch ON Unit will not run Damaged power cord Replace power cord Damaged power switch Replace switch Damaged motor Replace motor 6