CHEAT SHEET: SPECTRA V2.1

Similar documents
SPECTRA 1728, 1738 CHEAT SHEET:

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

Sentry 4 Zone Alarm Panel User Manual

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

DSC PowerSeries NEO Quick Start Guide

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Control/Communicator Installation Manual

EVO192 v3.0 Fire and Burglary What s New

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

Property of Monitronics Inc

HILLS Series LED Code Pad User Manual

System Programming Guide

CC488. Quick Reference Guide Solution Ultima 880

8-zone Expansion Module

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

Power Wave Zone Alarm Panel V8.5. Installation Manual

CC408. Quick Reference Guide Solution 880

System Introduction. 1.1 Specifications S E C T I O N 1

Digiplex Control Panel (DGP-848) - V4.0

3 User s settings. 3.3 Internal clock setting

4-PGM Expansion Module

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

System Introduction. 1.1 Specifications

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

Contents. Glossary

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Quick Programmer s Manual

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

Solution Ultima 862 Operators Manual ISSUE 1.10

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1


JA-63 Profi User manual

Solution Ultima Series Operators Manual ISSUE 1.00

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

VAP304 PRO INSTALLATION & OPERATION MANUAL

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Installation & Programming Guide

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10

QUICK USER MANUAL. Alarm Control Panel. The full user manual and other manuals are available on

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Summit 3208GLD USER MANUAL. Electronics Line

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

All-In-One Wireless Security System V1.0. Model # MG Programming Guide

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

(31/03/05) Version p1. INNER RANGE IQ. Programmer s Manual. Programmer s Manual Inner Range Pty. Ltd. Part Number:

ELT-KLED EliteSuite LED Keypad Installation Manual

AXI LED USER MANUAL (REV. 1.0)

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

X64 Wireless Training

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

Installation Manual Premier 412/816/832. Issue 10

MG5000 MG5050 SP5500 SP6000 SP7000. User Guide

Training Manual Multi-Language with Wireless

Elite Version. 8 Zone Control Communicator. Installation & Programming Guide. Proudly Designed and Manufactured in New Zealand

ITI Caretaker Basic Commands

All-In-One Wireless Security System V1.0. Model #: MG-6060

Solution 862 Installation Manual ISSUE 1.30

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

User s Information Guide R2A

LCD and 16-Zone LED Keypads. User s Manual

Version 1.03 January-2002 USER S MANUAL

(Updated Defaults) (Covers Ver: 8.64 and above)

16 ( Ver: Installation & Programming Guide. Power Wave 16 Zone Control Communicator. Crow Electronic Engineering (Australia) Pty Ltd

Watchguard WGAP864 User Manual

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Solution 844 Operators Manual ISSUE 1.10

NetworX Series NX-4V2 Control Panel Installation and Startup

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

DYGIZONE GJD910 Lighting Controller & Enunciator

Property of Monitronics Inc

IDS816 User Manual H Issued January 2009

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

INSTALLATION MANUAL PC56O. Version 1.OA

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

GEM-P800. Control Panel/Communicator. Installation Instructions

SMS8 Alarm Control Panel

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

10-Zone Spectra LED Keypads

Installation & Programming Guide

Transcription:

CHEAT SHEET: SPECTRA V2.1 Zone mapping Device connected To which input? NO ATZ WITH ATZ CONTROL PANEL INPUT 1= ZONE 1 ZONE 1 & 6 INPUT 2= ZONE 2 ZONE 2 & 7 INPUT 3= ZONE 3 ZONE 3 & 8 INPUT 4= ZONE 4 ZONE 4 & 9 INPUT 5= ZONE 5 ZONE 5 & 10 INPUT 6= N/A N/A INPUT 7= N/A N/A KEYPAD ZONE 1= ZONE 6 ZONE 11 ZONE 2= ZONE 7 ZONE 12 ATZ = Zone Doubling The Zone doubling feature allows you to install two devices per hardwired input terminal. Each detection device will have its own zone, display its own zone status on the keypad and send separate alarm codes for each zone. Each zone is differentiated by a different resistor value. EXPANSION INPUT 1= ZONE 8 ZONE 13 INPUT 2= ZONE 9 ZONE 14 INPUT 3= ZONE 10 ZONE 15 INPUT 4= ZONE 11 ZONE 16 INPUT 5= ZONE 12 N/A INPUT 6= ZONE 13 N/A INPUT 7= ZONE 14 N/A INPUT 8= ZONE 15 N/A *A location is referred to as a section. *Value or data is referred to as an option. How to enter programming: PRESS THE ENTER KEY ENTER THE INSTALLER CODE (DEFAULT: 0000). ENTER LIGHT WILL FLASH (INDICATING THAT A SECTION NUMBER MUST BE ENTERED) ENTER 3 DIGIT SECTION. ENTER LIGHT WILL TURN ON SOLID (INDICATING THAT YOU ARE AT A SECTION NUMBER) ENTER DATA AS REQUIRED * PRESS CLEAR ONCE STEP BACK ENTER LIGHT FLASHING 1

How to program zones: GET IN PROG. MODE: ENTER SECTION NUMBER (e.g: 001 = Zone 1) ENTER ONE DIGIT FROM THE ZONE DEFINITION TABLE (i.e. instant, follow (handover), entry) ENTER ONE DIGIT FROM THE PARTITION ASSIGNMENT TABLE (you are assigning hat zone to an area/partition) STEP 5: SELECT ONE OR MORE OPTIONS FROM THE ZONE OPTIONS TABLE (This table is a toggle ON/OFF feature.) I.e. if key 2 is on = Bypassable zone, this means it is enabled. If you want to disable it, press key 2, and the led will turn off. This disables that option. STEP 6: PRESS ENTER SAVE *PANEL AUMATICALLY JUMPS NEXT ADDRESS IN ZONE PROGRAMMING System timers: 069 ENTRY DELAY 1 *45 SECS 071 EXIT DELAY 1 *30 SECS 078 NUMBER OF RINGS *DISABLED 087 AU TEST REPORT DAYS *DISABLED 110 AU TEST REPORT TIME *DISABLED *Bold is default setting Programmable outputs. EVENT GROUP SUB-GROUP PARTITION 120 ACTIVATION EVENT 02 04 99 PULSED OR STEADY ALARM 121 DEACTIVATION EVENT 02 09 99 PARTITION STATUS DISARM Activation event is when you want the PGM (programmable output) to turn on. Deactivation event is when you would like the PGM to turn off. *The PGM provides a negative when turned on. AUX POSITIVE POS + (STROBE) PGM - *The programming example given above is for a strobe activation. 2

System option: The features within these sections are enabled/disabled by toggling the key options on/off. SECTION 127: 1 PARTITIONING *DISABLED SECTION 130: 1 ONE UCH ARMING *DISABLED 2 ONE UCH STAY ARMING *DISABLED 3 ONE UCH FORCE ARMING *DISABLED 4 ONE UCH BYPASS *DISABLED SECTION 131: 1 REPORT DISARMING *ONLY AFTER ALARM SECTION 132: 4 END OF LINE RESISRS *NO EOL 5 ZONE DOUBLING (1728) SECTION 135 : 3 REPORTING (DIALER) *DISABLED SECTION 136: 3 CONTACT ID REPORT CODES *ALL CODES AU SECTION 140: REPORTING FORMATS FOR TEL 1/ TEL 2 *5= CONTACT ID 6= PAGER FORMAT (USED FOR PERSONAL DIALLING) SECTION 143/144: ACCOUNT NUMBERS FOR PARTITION 1 & 2 SECTION 151/152: TEL NUMBER 1 & 2 FOR CENTRAL STATION OR PERSONAL DIALLING *Bold is default setting PROGRAMMING ACCESS CODES: STEP 5: SECTION 302: MASTER CODE 1 SECTION 303: MASTER CODE 2 SECTION 304 : USER CODE 4 SECTION 348: USER CODE 48 *Refer to page 18 of programming guide PRESS ENTER KEY IN MASTER CODE KEY IN 3 DIGIT USER LOCATIONS KEY IN NEW CODE ENTER LIGHT WILL FLASH, WAITING FOR NEW USER LOCATION (STEP 3). END, PRESS CLEAR. PROGRAM IN USER CODE OPTIONS 3

SECTION 281: INSTALLER CODE Wireless devices: PIR s and transmitters PIR s & Detectors: GET IN PROGRAMMING MODE KEY IN 3 DIGIT SECTION NUMBER (Refer to page 24 of prog. Guide) ENTER IN SERIAL NUMBER OF PIR OR TRANSMITTER For Example: SECTION 601 SERIAL NUMBER = EXPANSION INPUT 1 SECTION 602 SERIAL NUMBER = EXPANSION INPUT 2 SECTION 608 SERIAL NUMBER = EXPANSION INPUT 8 (The serial number is found on the PCB of the device.) ENABLE ZONE THAT RELATES THAT EXPANSION INPUT (Refer to zone mapping table) WIRELESS DEVICES: REMOTE CONTROLS ASSIGN REMOTE CONTROL 3 DIGIT USER LOCATION Ie. SECTION 701: _/_/_ REMOTE CONTROL 1 SECTION 702: _/_/_ REMOTE CONTROL 2 SECTION 708: _/_/_ REMOTE CONTROL 8 *REFER PAGE 26 OF PROGRAMMING GUIDE ASSIGN FEATURE OPTIONS YOUR BUTNS Ie SECTION 711: 1 / 5 / _ / _ / _ / _ / _ / _ / BUTN- A B C D A+B C+D A+C B+D FOR REMOTE CONTROL 1 SECTION 712: REMOTE CONTROL No 2 OPTIONS SECTION 718: REMOTE CONTROL No 8 OPTIONS Programmed here is: (example only) Button A to operate as Regular Arm = 1 Button B is to operate as Disarm = 5. If you want to only use button A and B, then press enter once you have added the options you require. PROGRAM IN THE REMOTES Ie SECTION 731: FOR REMOTE CONTROL 1. PRESS BUTN A TWICE (a confirmation beep will be heard). SECTION 732: FOR REMOTE CONTROL 2 SECTION 738: FOR REMOTE CONTROL 8 4

ZONE EXPANSION MODULES: ZX-4 OR ZX-8: ENTER PROGRAM MODE SECTION 650: OPTION 1 IS ENABLE END OF LINE SECTION 651: OPTION 1 IS ENABLE EXPANSION INPUT 1 OPTION 2 IS ENABLE EXPANSION INPUT 2 OPTION 8 IS ENABLE EXPANSION INPUT 8 (*OPTION 650 AND 651 IS A GGLE ON/OFF SECTION) ENABLE EXPANSION INPUT ZONES (REFER ZONE MAPPING TABLE) PERSONAL DIALLING: SECTION 135: ENABLE OPTION 3 REPORTING SECTION 136: DISABLE OPTION 3 CONTACT ID CODES SECTION 140: 6 / 6 PAGER FORMAT SECTION 143: 1234 PARTITION 1 ACCOUNT NUMBER STEP 5: SECTION 151 & 152: PROGRAM TELEPHONE NUMBER FOLLOWED BY TROUBLE 1 2 3 TROUBLE 1 2 3 STEP 6: SECTION 160 213: PROGRAM IN A 1 / 1 IN APPROPRIATE REPORTING CODE (*Page 16 of programming guide) STEP 7: SECTION 080: SET APPROPRIATE MAX. DIALING ATTEMPTS 5