CHEAT SHEET: SPECTRA V2.1 Zone mapping Device connected To which input? NO ATZ WITH ATZ CONTROL PANEL INPUT 1= ZONE 1 ZONE 1 & 6 INPUT 2= ZONE 2 ZONE 2 & 7 INPUT 3= ZONE 3 ZONE 3 & 8 INPUT 4= ZONE 4 ZONE 4 & 9 INPUT 5= ZONE 5 ZONE 5 & 10 INPUT 6= N/A N/A INPUT 7= N/A N/A KEYPAD ZONE 1= ZONE 6 ZONE 11 ZONE 2= ZONE 7 ZONE 12 ATZ = Zone Doubling The Zone doubling feature allows you to install two devices per hardwired input terminal. Each detection device will have its own zone, display its own zone status on the keypad and send separate alarm codes for each zone. Each zone is differentiated by a different resistor value. EXPANSION INPUT 1= ZONE 8 ZONE 13 INPUT 2= ZONE 9 ZONE 14 INPUT 3= ZONE 10 ZONE 15 INPUT 4= ZONE 11 ZONE 16 INPUT 5= ZONE 12 N/A INPUT 6= ZONE 13 N/A INPUT 7= ZONE 14 N/A INPUT 8= ZONE 15 N/A *A location is referred to as a section. *Value or data is referred to as an option. How to enter programming: PRESS THE ENTER KEY ENTER THE INSTALLER CODE (DEFAULT: 0000). ENTER LIGHT WILL FLASH (INDICATING THAT A SECTION NUMBER MUST BE ENTERED) ENTER 3 DIGIT SECTION. ENTER LIGHT WILL TURN ON SOLID (INDICATING THAT YOU ARE AT A SECTION NUMBER) ENTER DATA AS REQUIRED * PRESS CLEAR ONCE STEP BACK ENTER LIGHT FLASHING 1
How to program zones: GET IN PROG. MODE: ENTER SECTION NUMBER (e.g: 001 = Zone 1) ENTER ONE DIGIT FROM THE ZONE DEFINITION TABLE (i.e. instant, follow (handover), entry) ENTER ONE DIGIT FROM THE PARTITION ASSIGNMENT TABLE (you are assigning hat zone to an area/partition) STEP 5: SELECT ONE OR MORE OPTIONS FROM THE ZONE OPTIONS TABLE (This table is a toggle ON/OFF feature.) I.e. if key 2 is on = Bypassable zone, this means it is enabled. If you want to disable it, press key 2, and the led will turn off. This disables that option. STEP 6: PRESS ENTER SAVE *PANEL AUMATICALLY JUMPS NEXT ADDRESS IN ZONE PROGRAMMING System timers: 069 ENTRY DELAY 1 *45 SECS 071 EXIT DELAY 1 *30 SECS 078 NUMBER OF RINGS *DISABLED 087 AU TEST REPORT DAYS *DISABLED 110 AU TEST REPORT TIME *DISABLED *Bold is default setting Programmable outputs. EVENT GROUP SUB-GROUP PARTITION 120 ACTIVATION EVENT 02 04 99 PULSED OR STEADY ALARM 121 DEACTIVATION EVENT 02 09 99 PARTITION STATUS DISARM Activation event is when you want the PGM (programmable output) to turn on. Deactivation event is when you would like the PGM to turn off. *The PGM provides a negative when turned on. AUX POSITIVE POS + (STROBE) PGM - *The programming example given above is for a strobe activation. 2
System option: The features within these sections are enabled/disabled by toggling the key options on/off. SECTION 127: 1 PARTITIONING *DISABLED SECTION 130: 1 ONE UCH ARMING *DISABLED 2 ONE UCH STAY ARMING *DISABLED 3 ONE UCH FORCE ARMING *DISABLED 4 ONE UCH BYPASS *DISABLED SECTION 131: 1 REPORT DISARMING *ONLY AFTER ALARM SECTION 132: 4 END OF LINE RESISRS *NO EOL 5 ZONE DOUBLING (1728) SECTION 135 : 3 REPORTING (DIALER) *DISABLED SECTION 136: 3 CONTACT ID REPORT CODES *ALL CODES AU SECTION 140: REPORTING FORMATS FOR TEL 1/ TEL 2 *5= CONTACT ID 6= PAGER FORMAT (USED FOR PERSONAL DIALLING) SECTION 143/144: ACCOUNT NUMBERS FOR PARTITION 1 & 2 SECTION 151/152: TEL NUMBER 1 & 2 FOR CENTRAL STATION OR PERSONAL DIALLING *Bold is default setting PROGRAMMING ACCESS CODES: STEP 5: SECTION 302: MASTER CODE 1 SECTION 303: MASTER CODE 2 SECTION 304 : USER CODE 4 SECTION 348: USER CODE 48 *Refer to page 18 of programming guide PRESS ENTER KEY IN MASTER CODE KEY IN 3 DIGIT USER LOCATIONS KEY IN NEW CODE ENTER LIGHT WILL FLASH, WAITING FOR NEW USER LOCATION (STEP 3). END, PRESS CLEAR. PROGRAM IN USER CODE OPTIONS 3
SECTION 281: INSTALLER CODE Wireless devices: PIR s and transmitters PIR s & Detectors: GET IN PROGRAMMING MODE KEY IN 3 DIGIT SECTION NUMBER (Refer to page 24 of prog. Guide) ENTER IN SERIAL NUMBER OF PIR OR TRANSMITTER For Example: SECTION 601 SERIAL NUMBER = EXPANSION INPUT 1 SECTION 602 SERIAL NUMBER = EXPANSION INPUT 2 SECTION 608 SERIAL NUMBER = EXPANSION INPUT 8 (The serial number is found on the PCB of the device.) ENABLE ZONE THAT RELATES THAT EXPANSION INPUT (Refer to zone mapping table) WIRELESS DEVICES: REMOTE CONTROLS ASSIGN REMOTE CONTROL 3 DIGIT USER LOCATION Ie. SECTION 701: _/_/_ REMOTE CONTROL 1 SECTION 702: _/_/_ REMOTE CONTROL 2 SECTION 708: _/_/_ REMOTE CONTROL 8 *REFER PAGE 26 OF PROGRAMMING GUIDE ASSIGN FEATURE OPTIONS YOUR BUTNS Ie SECTION 711: 1 / 5 / _ / _ / _ / _ / _ / _ / BUTN- A B C D A+B C+D A+C B+D FOR REMOTE CONTROL 1 SECTION 712: REMOTE CONTROL No 2 OPTIONS SECTION 718: REMOTE CONTROL No 8 OPTIONS Programmed here is: (example only) Button A to operate as Regular Arm = 1 Button B is to operate as Disarm = 5. If you want to only use button A and B, then press enter once you have added the options you require. PROGRAM IN THE REMOTES Ie SECTION 731: FOR REMOTE CONTROL 1. PRESS BUTN A TWICE (a confirmation beep will be heard). SECTION 732: FOR REMOTE CONTROL 2 SECTION 738: FOR REMOTE CONTROL 8 4
ZONE EXPANSION MODULES: ZX-4 OR ZX-8: ENTER PROGRAM MODE SECTION 650: OPTION 1 IS ENABLE END OF LINE SECTION 651: OPTION 1 IS ENABLE EXPANSION INPUT 1 OPTION 2 IS ENABLE EXPANSION INPUT 2 OPTION 8 IS ENABLE EXPANSION INPUT 8 (*OPTION 650 AND 651 IS A GGLE ON/OFF SECTION) ENABLE EXPANSION INPUT ZONES (REFER ZONE MAPPING TABLE) PERSONAL DIALLING: SECTION 135: ENABLE OPTION 3 REPORTING SECTION 136: DISABLE OPTION 3 CONTACT ID CODES SECTION 140: 6 / 6 PAGER FORMAT SECTION 143: 1234 PARTITION 1 ACCOUNT NUMBER STEP 5: SECTION 151 & 152: PROGRAM TELEPHONE NUMBER FOLLOWED BY TROUBLE 1 2 3 TROUBLE 1 2 3 STEP 6: SECTION 160 213: PROGRAM IN A 1 / 1 IN APPROPRIATE REPORTING CODE (*Page 16 of programming guide) STEP 7: SECTION 080: SET APPROPRIATE MAX. DIALING ATTEMPTS 5