Updated: 8/16/ Facilities Profile

Similar documents
Updated: 5/6/16. Facility and Property Information Package

Master Facility Planning Update School Board Meeting May 26, 2016

Campus Middle School 4785 South Dayton Street Greenwood Village, Colorado 80111

Forest Hills Facilities Plan

Allisonville Elementary School Facilities Highlights Built: 1960 Last Major Renovation: 28 years ago Capacity: 650 Current Enrollment: 767

Adopted DEFP FY16 - Amendment. Broward County Public Schools. Amended to Incorporate Board Approved Changes

Chariho Regional School District Five-Year Capital Facilities Improvement Plan (2/10/15)

Cherry Hill Public Schools BUILDING A SOLID FUTURE

CAPITAL OUTLAY REQUEST - IDENTIFIED AND EMERGING PROJECTS - RANKED 3-Jun-14

2014 Bond District-wide Facility Repairs

2014 Bond District-wide Facility Repairs

Master Project List Report

VOTER BOND REFERENDUM 2018 SUMMARY OF WORK PROPOSED

5 Year Capital Improvement Plan Update

NYACK PUBLIC SCHOOLS CAPITAL IMPROVEMENT PLANNING PROCESS

School District of Milton 5- Year Capital Maintenance and Improvement Plan

Briar Crest Elementary

Tillamook High School Bond Projects

Oxford Hills School District Capital Renewal Plan Updated March 2017

New High School Concept

Warren County Schools Plant and Operations

Greenwood Elementary School 5550 South Holly Street Greenwood Village, Colorado 80111

3. 21st Century Learning A. Districtwide Flexible Learning - Allowance for Flexible Furniture $600,000 Subtotal $600,000

Sagebrush Elementary School East Temple Place Aurora, Colorado 80015

TIFT COUNTY SCHOOLS E-SPLOST HISTORY

REPORT CARD TO THE COMMUNITY MAY 15, 2018

ESUHSD Measure G Bond Program Update: November 1, Alterations to Student Services Building and Streetscape Building 1200 (Gym) Modernization

Proposed Bond Construction Projects

Meadow Point Elementary School East Grand Avenue Aurora, Colorado 80015

DEERFIELD SCHOOL DISTRICT REFERENDUM Committed to Excellence and Equity in Educating Our Students

29 Bella Fontaine Park

Community Response Buchanan Elementary. December 13, 2016

MARY CRAPO CENTER Miller Road, Swartz Creek, Michigan

FORT ERIE SECONDARY SCHOOL FACILITY INFORMATION. Lake Erie Corridor Secondary Schools Accommodation Review

2014 Bond Project Guide

Exhibit CC BALTIMORE COUNTY PUBLIC SCHOOLS

Design Review of Facility Improvement Projects

MOUNT PLEASANT MIDDLE SCHOOL HVAC. M-01 Heating Plant: M-02 Heating & Ventilating Systems: Livingston School District Mount Pleasant Middle School

Ichabod Crane Central School District 2018 Capital Project Preliminary Estimate

SITE FEASIBILITY TEST FIT LAYOUT NORTHERN AREA INTERNATIONAL SCHOOL DECEMBER 2016

e. Potential sources of air contaminants do not exist near the building. (e.g. chimneys, stacks, industrial plants, exhaust from nearby buildings)

Design Presentation. Chief Operations Officer Willie Burroughs

NAZARETH AREA SCHOOL DISTRICT MAINTENANCE DEPARTMENT 357 Tatamy Road, Nazareth, PA FAX

e. Potential sources of air contaminants do not exist near the building. (e.g. chimneys, stacks, industrial plants, exhaust from nearby buildings)

Ohlone College Measure G Project Scope Revisions

MUKWONAGO AREA SCHOOL DISTRICT CAPITAL IMPROVEMENT / MAINTENANCE STUDY

COVIDIEN SENECA, SOUTH CAROLINA

State College Area School District High School North Building EXISTING CONDITIONS ASSESSMENT

Downtown Redevelopment Project Update

Moreno Valley College: Conceptual Master Planning - Site Analysis Lasselle Street, Moreno Valley, CA 92551

Florence High School / Middle School Page 1 of 3 Florence, WI

MOUNTAIN VIEW ELEMENTARY SCHOOL SITE REDEVELOPMENT OPEN HOUSE. MacPherson Room, 10 am 5 pm

Ottawa Hills. Local Schools

Madeira City Schools Madeira, Ohio. HVAC Assessment. December 2011 (Revised February 2012)

Encumbered Balance (E-D) Branham HVAC Implementation Complete 100% 03/04/19 07/19/19 $765, $635, $635, $130, $0.

John Palmer Elementary School

Greater Albany Public Schools May 2017 Ballot Measure for School Repairs, Crowding and Job Training

Community Unit School District 200 Facilities

Status Report for Parks and Recreation Capital Projects

ALLEGHANY COUNTY PUBLIC SCHOOLS Maintenance Work Request Completion Analysis

REQUIRED CONTRACT DETAIL. $2, , Direct DC Fuel Cell Power System, Stationary PACE Power output < 40 kw

Oconomowoc Area School District Facility Construction Update August 25, 2017

Josefa Ortiz De Dominguez Elementary School

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

Facilities Management Services

e. Potential sources of air contaminants do not exist near the building. (e.g. chimneys, stacks, industrial plants, exhaust from nearby buildings)

Existing Facilities Assessment

498 E. Bellevue Avenue Reading, PA 19601

BALTIMORE COUNTY PUBLIC SCHOOLS

E-SPLOST V. Facts and Information. August 2018

Oscar DePriest Elementary School

MASTER PLAN DIAGRAMS DISTRICT CAMPUS OVERVIEW

2015 Building Condition Survey Summary Mosaic Associates Architects 02/19/16

Joseph Brennemann Elementary School

ALLISON ELEMENTARY SCHOOL 4315 Don Julio Blvd., North Highlands, CA 95660

The Legacy Project Former Hardee s Headquarters N. Church Street Rocky Mount, NC. Offered for Lease or Sale

Summary of Repairs and Deficiencies

Francis M McKay Elementary School

MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN

Ottawa Hills. Local Schools. Master Facili,es Plan Presenta,on

LAMPETER-STRASBURG SCHOOL DISTRICT Lampeter, Pennsylvania 17537

Avon Board of Education. Capital Improvement Plan Presentation to Board of Education October 17, 2017

For Sale/Lease th Street North, St. Cloud, MN ,250,000. Mark A. Williams

DCPS Execution report by funding year

Facility Improvements

Loudoun County Public Schools Continuity of Operations Plan (COOP) Facilities Assessment Study Related to Critical Systems

MEASURE A. Completed Bond Projects

CENTRAL GEORGIA TECHNICAL COLLEGE. Maintenance, Custodial & Operation Plan Facilities & Equipment

MUKWONAGO SCHOOL DISTRICT CAPITAL IMPROVEMENT / MAINTENANCE STUDY

FOR IMMEDIATE RELEASE DATE: FRIDAY, AUGUST 31, Road Commission of Kalamazoo County Weekly Project Updates HAVE YOU SIGNED UP?

FOR SALE OR LEASE ±12,600 SQ. FT. AUTO/TRUCK SERVICE FACILITY

ATTACHMENT 8: DETAILED PROJECT DESCRIPTION. The proposed buildings would be constructed in two phases, as follows:

Kerrville ISD has called for a bond election in the amount of $88,960,000 for November 6, 2018

Achieving a Vision. Master Plan 2009 Belknap Campus August 10 11, UofL Belknap Campus Master Plan Update

2 Main Office Building BLDG-955A Building Purpose Building Area Administration offices. Training room 7,610 SF Inspection Date August 16, 2016 Inspect

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

January 11, New benches installed. Paving of parking lot adjacent to piers and the canoe put-in. Near complete with clean up remaining.

Edward Jenner Elementary Academy of the Arts

Bonners Ferry. Welcome to. Size: 3,788 sq. ft. Style: Single Story Taxes: $1,839 (2012)

Agustin Lara Elementary Academy

Transcription:

Updated: 8/16/17 2017-2018 Facilities Profile

Purpose This package is put together to provide general information to District Administration, the School board and the public. The information contained is taken from facility prints, engineering data, historical archive data and site visits. It is the intention of the Operations Department to keep this file updated quarterly. Information about the data On each sheet there is a maximum and recommended school capacity. These maximum capacities are calculated by the number of actual classrooms at 21 students per classroom. The recommended capacity is 90% of that number in order to accommodate slight fluctuations in population. This number was used because it is our current mandated teacher-student ratio. It should be noted that classrooms are normally designed for 28 to 30 students. Current enrollment is taken from the 45 day report. There are pervious acreage s listed. This simply means the amount of property that the grounds crews must maintain. The remaining property would have buildings, paving and concrete. Considerations and are the opinions of the Director of Operation after discussions with our consulting engineers, and with District Operations Coordinators. Energy information is taken from the previous full year data. It is evident that each building component has a designed useful life expectancy. It is the recommendation of the Operations Department that as the life expectancy of a component approached the end that it be evaluated and scheduled for replacement before failure due to the fact that component failure would result in a loss of classroom time. To that end the Operations Department has compiled lists of major building components that include the date of installation and designed life time. Assistant Superintendent of Administration Marion Lawson Coordinator of Maintenance George Blake Energy Manager Greg Raines Grounds Coordinator Thomas Shirley Director of Operations Marion Thomas Projects Coordinator Steve Triplett HVAC Coordinator Brian Doty Custodial/Safety Coordinator Tim Huff

A. R. LEWIS OPPORTUNITY SCHOOL 1755 SHADY GROVE RD. PICKENS, SC, 29671 Grades: K-5 50,692 sf Number of Classrooms 22 Maximum Capacity 462 Recommended Capacity 416 Current Enrollment? Current % of recommended capacity?% Property is 18.33 acer parcel #4162-00-20-7277 Property is 10.99 acres pervious Original facility constructed in the 1950 s A 2 nd classroom wing addition was completed in the late 1980 s.the latest addition was completed in 2010 and included 5 additional classrooms and the gym. HVAC was replaced in the 50 s and 80 s wings in 2017. Facility has no emergency power generation capabilities. Fire Alarm system is manufactured by Notifier and was installed in 2009. The facility has no fire sprinkler system. The facility has 51 paved, lined parking spaces. Original building has a shingle roof installed 2006. Addition roof is membrane installed in 2009. LP Gas Facility energy stats: 13.47 kbtu s per sq. ft. @ $24,894 per year Blue Ridge Cooperative Blossman Six Mile Rural Septic System Paving and fencing needed. Upgrade to LED lighting fixtures

AMBLER ELEMENTARY SCHOOL 838 AMBLER SCHOOL RD. PICKENS, SC, 29671 Grades: K-5 42,331sf Number of Classrooms 20 Maximum Capacity 420 Recommended Capacity 378 Current Enrollment 358 Current % of recommended capacity 95% Property is 10.10 acer parcel #5104-00-10-2734 Property is 6.01 acres pervious Original facility constructed in the 1950 s A 2 nd classroom wing addition was completed in 1996 along with the installation of air to air electric heat pump HVAC systems for each classroom. The latest addition was completed in 2010 and included 5 additional classrooms and the media center. Facility has no emergency power generation capabilities. Fire Alarm system is manufactured by Notifier and was installed in 2009. The facility has no fire sprinkler system. Original bldg. roof is Metal standing seam roof installed 1996. Addition roof is membrane 2009. Facility energy consumption: 26.08 kbtu s per sq. ft. @ $ 45,331 per year Blue Ridge Cooperative Fort Hill Pickens City Septic System Facilities heat pumps are past the useful life expectancy. SCDOT traffic issues during drop off and pick up. Plan should be in place to fund needed component replacement. Replace HVAC units soon. There is a possibility that Fort Hill Natural Gas will be available soon. Paving additional parking needed. Upgrade to LED lighting fixtures.

HOLLY SPRINGS CENTER 120 HOLLY SPRINGS SCHOOL RD. PICKENS, SC, 29671 Grades: K-5 35,486 sf Number of Classrooms 19 Maximum Capacity 399 Recommended Capacity 359 Current Enrollment 0 Current % of recommended capacity 0% Property is 14.64 acer parcel #4174-00-46-6539 Property is 10.98 acres pervious Original facility constructed in the 1950 s A 2 nd classroom wing addition was completed in 1996 along with the installation of air to air electric heat pump HVAC systems for each classroom. The latest addition was completed in 2010 and included 5 additional classrooms, new kitchen and the media center. Facility has no emergency power generation capabilities. Fire Alarm system is manufactured by Notifier and was installed in 2009 The facility has no fire sprinkler system. Original bldg. roof is Metal standing seam roof installed 1996. Addition roof is membrane 2009. Facility energy consumption: 13.52 kbtu s per sq. ft. @ $ 19,525 per year Blue Ridge Cooperative Not currently available Pickens City Septic System Facilities heat pumps are past the useful life expectancy. SCDOT traffic issues during drop off and pick up. Plan should be in place to fund needed component replacement. Replace HVAC units soon.

PICKENS ELEMENTARY SCHOOL 567 HAMPTON AVE. PICKENS, SC, 29671 Grades: K-5 64,131 sf Number of Classrooms 34 Maximum Capacity 714 Recommended Capacity 642 Current Enrollment 503 Current % of recommended capacity 78% Property is 15.00 acer parcel #4191-17-00-3832 Property is 6.00 acres pervious Original facility constructed in the mid-1960 s A 2 nd classroom wing addition was completed in 1996 HVAC system is water source heat pumps installed in 2008. Facility has no emergency power generation capabilities. Fire Alarm system is manufactured by Notifier and was installed in 2008 The facility has no fire sprinkler system. Modified bitumen roof installed 2015 SCDOT traffic issues during drop off and pick up. Facility energy consumption: 30.07 kbtu s per sq. ft. @ $ 50,719 per year Duke Energy Fort Hill Pickens City Pickens City Pickens City. Evaluate HVAC systems in the 2027 timeframe. Evaluate roofing system in the 2035 timeframe.

HAGOOD ELEMENTARY SCHOOL 435 SPARKS LN. PICKENS, SC, 29671 Grades: K-5 55,266 sf Number of Classrooms 31 Maximum Capacity 651 Recommended Capacity 585 Current Enrollment 492 Current % of recommended capacity 84% Property is 22.63 acer parcel #4181-08-89-5195 Property is 13.42 acres pervious Original facility constructed in the 1980 A 5 classroom wing addition was completed in 2009 HVAC units are Gas/electric rooftop packaged units installed in 2017. Facility has no emergency power generation capabilities. Fire Alarm system is manufactured by Fire Lite and was installed in 2009. The facility has fire sprinkler system in 2009 addition only. Original bldg. has modified bitumen roof installed 2017. The addition roof is membrane installed 2009. Facility energy consumption: 33.38 kbtu s per sq. ft. @$47,743 per year Duke Energy Fort Hill Pickens City Pickens City Pickens City. Plan should be in place to fund needed component replacement. Replace original windows. Replace gym floor covering. Replace HVAC heat exchangers on or around 2027.

PICKENS MIDDLE SCHOOL 140 TORCH LN. PICKENS, SC, 29671 Grades: 6-8 146,941 sf Number of Classrooms 54 Maximum Capacity 1,134 Recommended Capacity 1,021 Current Enrollment 677 Current % of recommended capacity 66% Property is 23.23 acer parcel #4181-12-95-1775 Property is 10.84 acres pervious Original facility constructed in the mid-1950 s. The entire facility, with the exception of the Gym underwent an extensive renovation in 2013. HVAC system is water source heat pumps installed during the 2013 renovations. Gym HVAC is gas electric package units installed in 1999. Facility emergency power generation, 2013 Caterpillar diesel with 40 kw capacity. Fire Alarm system is manufactured by Notifier and was installed in 2008. Facility is fully fire sprinkled. Roofing is a combination of built-up, shingle, and metal. All were installed between 2012 and 2014 Facility energy consumption: 28.90 kbtu s per sq. ft. @ $117,221 per year Duke Energy Fort Hill Pickens City Pickens City Pickens City. HVAC units for the gym have reached the end of useful life. Replace Gym HVAC units as soon as possible. Failure is imminent Evaluate HVAC and roofing systems in the 2032 timeframe.

PICKENS HIGH SCHOOL 150 BLUE FLAME DR. PICKENS, SC 29671 Grades: 9-12 251,336 sf Number of Classrooms 81 Maximum Capacity 1701 Recommended Capacity 1,701 Current Enrollment 1,331 Current % of recommended capacity 82% Property is 138.86 acer parcel #4182-18-42-8377 Property is 93.76 acres pervious Facility was constructed in the 2011. The HVAC system is a 4 pipe system with vav s/electric reheat. Main Facility emergency power generation, 2011 Caterpillar diesel with 350 kw capacity. Stadium emergency power generation, 2011 Caterpillar diesel with 30 kw capacity. Fire Alarm system is manufactured by Notifier and was installed in 2011. The facility is fully fire sprinkled. Roof is built up and installed in 2011. Facility energy consumption: 35.47 kbtu s per sq. ft. @ $270,653. Sports Facilities $33,283 per year. Total $303,936 per year Blue Ridge Cooperative Fort Hill Pickens City Septic System Fund a reasonable grounds maintenance program. Evaluate HVAC and roofing systems in the 2031 timeframe. Evaluate artificial athletic surfaces 2021

DACUSVILLE ELEMENTARY SCHOOL 200 CHEROKEE TRAIL EASLEY, SC 29640 Grades: K-5 97,696 sf Number of Classrooms 41 Maximum Capacity 861 Recommended Capacity 775 Current Enrollment 650 Current % of recommended capacity 84% Property is 113.65 acer parcel #5132-04-74-5004 Property is 81.2 acres pervious Original facility constructed in the 2011 HVAC units are water source heat pumps installed in 2011. Facility emergency power generation, 2011 Caterpillar diesel with 40 kw capacity. Fire Alarm system is manufactured by Notifier and was installed in 2011. The facility has a full fire sprinkler system Modified bitumen built up roof installed 2011 Facility energy consumption: 30.64 kbtu s per sq. ft. @ $99,462 per year Blue Ridge Cooperative Fort Hill Dacusville-Cedar Rock District Septic system Evaluate HVAC and roofing systems in the 2032 timeframe. Setup and fund facility painting schedule. Convert cooking equipment to natural gas.

DACUSVILLE MIDDLE SCHOOL 899 THOMAS MILL RD. EASLEY, SC 29640 Grades: 6-8 73,316 sf Number of Classrooms 27 Maximum Capacity 567 Recommended Capacity 510 Current Enrollment 327 Current % of recommended capacity 64% Property is shared parcel with Dacusville Elem. Original facility constructed in the 1997 HVAC units are water source heat pumps installed in 1997. Facility does not have emergency power generation capabilities. Fire Alarm system is manufactured by Fire Lite and was installed in 2011. The facility has no fire sprinkler system. Roof is standing seam metal installed at construction in 1997. Facility energy consumption: 40.08 kbtu s per sq. ft. @ $91,440 per year Blue Ridge Cooperative Fort Hill Dacusville-Cedar Rock District Septic system HVAC system is approaching the end of useful life. The 2 cooling towers are in need of replacement. Funding for HVAC replacement should be planned. Need to add insulation above ceiling and add high efficiency boilers. Energy consumption at this facility is 20 to 25% above where it should be.

CROSSWELL ELEMENTARY SCHOOL 161 SCHOOL RD. EASLEY, SC29640 Grades: K-5 76,673 sf Number of Classrooms 38 Maximum Capacity 798 Recommended Capacity 718 Current Enrollment 470 Current % of recommended capacity 65% Property is 24.81 acer parcel #5140-17-21-0057 Property is 12.92 acres pervious Original facility constructed in the 1980 An 8 classroom wing addition was completed in 2004 A 2 classroom addition was completed in 2009 HVAC units are Gas/electric rooftop packaged units installed in 2016. Facility has no emergency power generation capabilities. Fire Alarm system is manufactured by Fire Lite and was installed in 2009. The facility has fire sprinkler system in 2004 and 2009 addition only. Original bldg. has modified bitumen roof installed 2016. The 2004 wing roof is a built-up/metal combination. The 2 class addition roof is membrane installed 2009 Evaluate trees on property. Facility energy consumption: 24.93 kbtu s per sq. ft. @ $71,072 per year Fort Hill Septic system Replace original windows. Replace ceiling grid and tile. Renovate restroom facilities. Replace boxing under all exterior windows. Replace HVAC heat exchangers on or around 2026.

EAST END ELEMENTARY SCHOOL 505 EAST SECOND AVE. EASLEY, SC 29640 Grades: K-5 80,306 sf Number of Classrooms 38 Maximum Capacity 798 Recommended Capacity 718 Current Enrollment 759 Current % of recommended capacity 106% Property is 7.2 acer parcel #5029-13-13-3545 Property is 1.89 acres pervious Original facility constructed in the 1950 s A major building program replaced most of the original facility in 2004 HVAC system is 2 pipe hydronic with unit ventilators installed in 2004. Facility has no emergency power generation capabilities. Fire Alarm system is manufactured by Fire Lite and was installed in 2004. The facility has fire sprinkler system in 2004 addition only. What is left of the original roof is architectural shingle installed in 2014. The 2004 buildings is a modified bitumen and Metal combination. Facility energy consumption: 34.24 kbtu s per sq. ft. @ $98,382 per year Fort Hill There are DOT and traffic flow issues, we have no property to correct. Evaluate Roof and HVAC systems in the 2024 timeframe. Setup and fund facility painting schedule.

FOREST ACRES ELEMENTARY SCHOOL 401 MCALISTER RD. EASLEY, SC 29640 Grades: K-5 86,096 sf Number of Classrooms 47 Maximum Capacity 987 Recommended Capacity 889 Current Enrollment 687 Current % of recommended capacity 77% Property is 19.8 acer parcel #5028-08-78-7895 Property is 7.92 acres pervious Original facility constructed in the 1960 s A major building addition was completed 2004 HVAC system was replaced with water source heat pump system in 2014. Facility has no emergency power generation capabilities. Fire Alarm is manufactured by Fire Lite and was installed in 2009. The facility has fire sprinkler system in 2004 addition only. The roofing was done in 2 phases and is modified bitumen. The original bldg. was re-roofed in 2014, the addition wings 2004. Facility energy consumption: 27.68 kbtu s per sq. ft. @ $89,770 per year Fort Hill The facilities paving is in poor condition. There are DOT and traffic flow issues. Funding should be planned soon to repave facility parking and drives. Setup and fund facility painting schedule.

MCKISSICK ELEMENTARY SCHOOL 156 MCKISSICK SCHOOL RD. EASLEY, SC 29640 Grades: K-5 74,225 sf Number of Classrooms 26 Maximum Capacity 546 Recommended Capacity 491 Current Enrollment 457 Current % of recommended capacity 93% Property is 34.8 acer parcel #5110-19-61-8294 Property is 19.20 acres pervious Original facility constructed in the 1973 A classroom wing addition and gym was completed in 2013 HVAC units are Gas/electric rooftop packaged units installed in 2015. Facility has no emergency power generation capabilities. Fire Alarm system is manufactured by Notifier and was installed in 2013. The facility has a full fire sprinkler system. Pod roofing is architectural shingle and modified bitumen roof installed 2013-2015. the addition is built-up installed in 2013. Facility energy consumption: 27.33 kbtu s per sq. ft. @ $72,201 per year Fort Hill Paving is starting to become an issue. Paving is in need of replacing. Setup and fund facility painting schedule.

WEST END ELEMENTARY SCHOOL 314 PELZER HWY. EASLEY, SC 29640 Grades: K-5 83,340 sf Number of Classrooms 48 Maximum Capacity 1,008 Recommended Capacity 907 Current Enrollment 681 Current % of recommended capacity 75% Property is 27.43 acer parcel #5018-12-85-6471 Property is 16.57 acres pervious Original facility constructed in 1982 A major building addition was completed 2004 The original building HVAC system was replaced with a 2 pipe hydronic system in 2000. The building addition HVAC system is 2 pipe hydronic with unit ventilators installed in 2004. Facility has no emergency power generation capabilities. Fire Alarm system is manufactured by Notifier and was installed in 2010. The facility has fire sprinkler system in 2004 addition only. The original Building is modified bitumen and was re-roofed in 2004. The 2004 addition is a modified bitumen and Metal combination. Facility energy consumption: 36.97 kbtu s per sq. ft. @ $99,127 per year Fort Hill There are ongoing issues with the installation of the underground domestic water piping. One of the fin tube boilers is exceeded its useful life and is in danger of failure. Have the underground piping re-engineered and replaced. Setup and fund facility painting schedule. Evaluate HVAC systems for replacement in the 2022 timeframe.

GETTYS MIDDLE SCHOOL 510 SOUTH PENDLETON ST. EASLEY, SC 29640 Grades: 6-8 208,618 sf Number of Classrooms 75 Maximum Capacity 1,575 Recommended Capacity 1,417 Current Enrollment 1,328 Current % of recommended capacity 94% Property is 21.71 acer parcel #5019-20-81-7779 Property is 6.93 acres pervious Original facility constructed in the 1939 A major building addition was completed 1978 adding the B building and Gym. 2013 the entire facility was renovated adding the C building and replacing the HVAC in the D building to a water source heat pump system. HVAC system in A and B buildings were replaced with a water source heat pump system in 2013. The gym is 4 pipe hydronic installed in 2013 Facility emergency power generation, 2013 Kohler diesel with 125 kw capacity. Fire Alarm system is manufactured by Notifier and was installed in 2013. The roofing for A bldg. is shingle 2013/poor install, B Facility energy consumption: 25.81 kbtu s per sq. ft. @ $184,444 per year Fort Hill Fencing for car loop is needed. Old storage building at football field should be replaced or removed. HVAC units for the gym have reached the end of useful life. Setup and fund facility painting schedule. Evaluate HVAC and roofing systems in the 2032 timeframe. Replace Gym HVAC units as soon as possible, Failure is imminent. Roof over gym locker rooms need to be replaced as soon as possible. D building needs attic insulation. Setup and fund facility painting schedule.

EASLEY HIGH SCHOOL 154 GREENWAVE BLVD. EASLEY, SC 29640 Grades: 9-12 266,117 sf Number of Classrooms 81 Maximum Capacity 1,701 Recommended Capacity 1,701 Current Enrollment 1,683 Current % of recommended capacity 99% Property is 162.85 acer parcel #5027-07-59-1812 Property is 112.35 acres pervious Facility was constructed in the 2012 The HVAC system is a 4 pipe system with vav s/electric reheat. Main Facility emergency power generation, 2012 Kohler diesel with 350 kw capacity. Stadium emergency power generation, 2012 Kohler diesel with 30 kw capacity. Fire Alarm system is manufactured by Notifier and was installed in 2012. The facility has a full fire sprinkler system Roof is built up and installed in 2012. Facility energy consumption: 36.65 kbtu s per sq. ft. @ $350,458. Sports Facilities $39,897 per year. Total 390,355 per year Fort Hill Construction site permit is still open. School request separate restroom facilities Baseball fields. Setup and fund facility painting schedule. Fund a reasonable grounds maintenance program. Evaluate HVAC and roofing systems in the 2032 timeframe. Evaluate artificial athletic surfaces 2022 Setup and fund facility painting schedule.

CENTRAL ELEMENTARY SCHOOL 608 JOHNSON RD. CENTRAL, SC 29630 Grades: K-5 59,409 sf Number of Classrooms 31 Maximum Capacity 651 Recommended Capacity 585 Current Enrollment 362 Current % of recommended capacity 62% Property is 19.47 acer parcel #4066-00-60-6942 Property is 7.78 acres pervious Original facility constructed in the 1980 An 8 classroom wing addition was completed in 2009 HVAC units are Gas/electric rooftop packaged units installed in 2015. Facility has no emergency power generation capabilities. Fire Alarm system is manufactured by Fire Lite and was installed in 2009. The facility has fire sprinkler system in 2009 addition only. Original bldg. has a modified bitumen roof installed 2015. The addition roof is Siplast installed in 2009. Facility energy consumption: 23.96 kbtu s per sq. ft. @ $38,874 per year Duke Energy Fort Hill City of Central City of Central City of Central Replace original windows. Replace ceiling grid and tile. Renovate restroom facilities. Replace boxing under all exterior windows. Replace HVAC heat exchangers on or around 2025.

CLEMSON ELEMENTARY SCHOOL 581 BERKELY DR. CLEMSON, SC 29631 Grades: K-5 119,000 sf Number of Classrooms 48 Maximum Capacity 1,008 Recommended Capacity 907 Current Enrollment 865 Current % of recommended capacity 95% Property is 36.4 acer parcel #4064-13-03-3473 Property is 18.19 acres pervious Original facility constructed in the 2001 HVAC units are Geothermal-water source heat pumps installed in 2001. Facility emergency power generation, 2000 Caterpillar natural gas with 30kW capacity. Fire Alarm system is manufactured by Notifier and was installed in 2015. The facility has no fire sprinkler system. Standing seam metal installed in 2001. Facility energy consumption: 27.41 kbtu s per sq. ft. @ $97,726 per year Duke Energy Fort Hill City of Clemson City of Clemson Republic Service Co. HVAC system will reach its useful life expectancy within the next 5 years. Plans should start be made for funding HVAC replacement in 2021. Additional parking needed. Setup and fund facility painting schedule. Parking loop lights belong to Duke Energy

SIX MILE ELEMENTARY SCHOOL 777 NORTH MAIN ST. SIX MILE, SC 29682 Grades: K-5 65,946 sf Number of Classrooms 27 Maximum Capacity 567 Recommended Capacity 510 Current Enrollment 507 Current % of recommended capacity 99% Property is 28.88 acer parcel #4059-00-61-1836 Property is 17.23 acres pervious Original facility constructed in the 1990 HVAC units are water source heat pumps installed in 2014. Facility has no emergency power generation capabilities. Fire Alarm system is manufactured by Fire Lite and was installed in 2012. The facility has no fire sprinkler system. Roofing is Architectural Shingle installed in 2011 Bus loop asphalt is in very poor condition. Facility energy consumption: 33.77 kbtu s per sq. ft. @ $66,328 per year Duke Energy Fort Hill Six Mile District Septic System Republic Service Co. Plans should be made for funding bus loop paving need. Setup and fund facility painting schedule. Parking loop lights belong to Duke Energy

EDWARDS MIDDLE SCHOOL 1157 MADDEN BRIDGE RD. CENTRAL, SC 29630 Grades: 6-8 115,390 sf Number of Classrooms 47 Maximum Capacity 987 Recommended Capacity 888 Current Enrollment 812 Current % of recommended capacity 91% Property is 30.00 acer parcel #4055-06-38-5649 Property is 12.00 acres pervious Original facility constructed in the 1971. with 2 classroom wing additions and the office wing constructed in 2013. Original bldg. HVAC system a modified 4 pipe with vav s installed in 2000. Gym units are gas/electric rooftop packaged units installed in 2000. The 3 new wings have gas/electric rooftop packaged units installed in 2013. Facility emergency power generation, 2013 Caterpillar diesel with 125 kw capacity. Fire Alarm system is manufactured by Notifier and was installed in 2013. The facility has a full fire sprinkler system. Original bldg. was re-roofed in 2014 and is build-up type. The additions roofing was installed in 2013. Facility energy consumption: 28.36 kbtu s per sq. ft. @ $94,885 per year Blue Ridge Cooperative Fort Hill Six Mile District Town of Central HVAC units for the gym have reached the end of useful life. Replace Gym HVAC units as soon as possible, Failure is imminent Evaluate HVAC and roofing systems in the 2028 timeframe.

DANIEL HIGH SCHOOL 140 BLUE AND GOLD BLVD. CENTRAL, SC 29630 Grades: 9-12 225,990 sf Number of Classrooms 59 Maximum Capacity 1,239 Recommended Capacity 1,239 Current Enrollment 1,097 Current % of recommended capacity 89% Property is 92.86 acer parcel #4046-20-91-3518 Property is 65.01 acres pervious Facility was constructed in the 2012. The HVAC system is a 4 pipe system with vav s/electric reheat. Main Facility emergency power generation, 2013 Kohler diesel with 350 kw capacity. Stadium emergency power generation, 2012 Kohler diesel with 40 kw capacity. Fire Alarm system is manufactured by Notifier and was installed in 2013. The facility has a full fire sprinkler system Roof is built up and installed in 2012. Facility energy consumption: 40.39 kbtu s per sq. ft. @ $276,026. Sports Facilities $41,269 per year. Total $317,295 per year Blue Ridge Cooperative Fort Hill Pickens City Septic System Fund a reasonable grounds maintenance program. Evaluate HVAC and roofing systems in the 2032 timeframe. Evaluate artificial athletic surfaces 2022 Setup and fund facility painting schedule.

CHASTAIN ROAD ELEMENTARY SCHOOL 940 CHASTAIN RD. LIBERTY, SC 2965 Grades: K-5 93,160 sf Number of Classrooms 37 Maximum Capacity 777 Recommended Capacity 699 Current Enrollment 564 Current % of recommended capacity 81% Property is 87.47 acer parcel #4086-00-33-9768 Property is 52.32 acres pervious Original facility constructed in the 2012 HVAC units are water source heat pumps installed in 2012. Facility emergency power generation, 2012 Caterpillar diesel with 40 kw capacity. Fire Alarm system is manufactured by Notifier and was installed in 2012. The facility has a full fire sprinkler system. Modified bitumen built up roof installed 2012 Facility energy consumption: 34.64 kbtu s per sq. ft. @ $103,033 per year Blue Ridge Cooperative Fort Hill Southside Rural District Pickens County Evaluate HVAC and roofing systems in the 2032 timeframe. Setup and fund facility painting schedule.

LIBERTY ELEMENTARY SCHOOL 251 NORTH HILLCREST ST. LIBERTY, SC 29657 Grades: K-5 73,887 sf Number of Classrooms 38 Maximum Capacity 798 Recommended Capacity 718 Current Enrollment 512 Current % of recommended capacity 71% Property is 14.93 acer parcel #4087-08-89-6743 Property is 10.52 acres pervious Original facility constructed in the 1960 s A classroom wing addition was completed in 1996 along with the installation of a water source heat pump HVAC systems. Facility has no emergency power generation capabilities. Fire Alarm system is manufactured by Notifier installed in 2012. The facility has no fire sprinkler system. Roofing has been done in 3 sections and all are modified bitumen. The addition was installed 1996, the original section was reroofed in 2007 and the office/media and cafeteria were re-roofed in 2004. Facility energy consumption: 35.66 kbtu s per sq. ft. @ $72,843 per year Duke Energy Fort Hill Liberty & Liberty & Liberty City Cooling tower is in bad condition. HVAC system is approaching useful life expectancy. 1996 wing roof approaching useful life expectancy. Plans should be made for funding HVAC and roofing needs.

LIBERTY MIDDLE SCHOOL 125 FALCON LN. LIBERTY, SC 29657 Grades: 6-8 104,848 sf Number of Classrooms 35 Maximum Capacity 735 Recommended Capacity 662 Current Enrollment 543 Current % of recommended capacity 82% Property is 34.98 acer parcel #4087-07-69-2037 Property is 15.74 acres pervious Original facility constructed in the 1985 A classroom wing addition was completed in 1996. The HVAC system is water source heat pumps that were installed in 2004. Facility emergency power generation, 2013 Caterpillar diesel with 80 kw capacity. Fire Alarm system is manufactured by Notifier installed it 2013. The facility has a full fire sprinkler system. Original bldg. was re-roofed in 2005 with modified bitumen. The 1996 additions were re-roofed in 2014 and are also built-up bitumen. Facility energy consumption: 32.71 kbtu s per sq. ft. @ $84,155 per year Duke Energy Fort Hill Liberty & Liberty & Liberty City HVAC units for the gym have reached the end of useful life. Replace Gym HVAC units as soon as possible, Failure imminent. Evaluate HVAC and roofing systems in the 2023 timeframe.

LIBERTY HIGH SCHOOL 124 RED DEVIL DR. LIBERTY, SC 29657 Grades: 9-12 179,057 sf Number of Classrooms 39 Maximum Capacity 819 Recommended Capacity 819 Current Enrollment 752 Current % of recommended capacity 92% Property is 110.67 acer parcel #4087-00-61-9509 Property is 59.31 acres pervious Facility was constructed in the 2011. The HVAC system is a 4 pipe system with vav s/electric reheat. Main Facility emergency power generation, 2011 Kohler diesel with 350 kw capacity. Stadium emergency power generation, 2011 Kohler diesel with 30 kw capacity. Fire Alarm system is manufactured by Notifier and was installed in 2011. The facility has a full fire sprinkler system. Roof is built up and installed in 2011. Facility energy consumption: 40.85 kbtu s per sq. ft. @ $168,529. Sports Facilities $23,245 per year. Total $191,774 per year Duke Energy Fort Hill Southside District Liberty & Artificial track surface is having issues. Fund a reasonable grounds maintenance program. Evaluate HVAC and roofing systems in the 2031 timeframe. Evaluate artificial athletic surfaces 2021 Setup and fund facility painting schedule.

PICKENS COUNTY CAREER & TECHNOLOGY CENTER 990 CHASTAIN RD. LIBERTY, SC 29657 Industrial Education 151,584 sf Number of Classrooms 37 Maximum Capacity Recommended Capacity Current Enrollment Current % recommended capacity Property is a shared parcel with Chastain Rd. Elem Original facility constructed in the 2011. HVAC Systems are a combination of 2 pipe hydronic heat/dx cooling and gas/electric rooftop packaged units installed in 2011. Facility emergency power generation, 2012 Kohler diesel with 125 kw capacity. Fire Alarm system is manufactured by Notifier and was installed in 2011. The facility has a full fire sprinkler system. Modified bitumen built up roof installed 2011. Facility energy consumption: 31.88 kbtu s per sq. ft. @ $130,941 per year Blue Ridge Cooperative Fort Hill Southside Rural District Pickens County Fund a reasonable grounds maintenance program. Evaluate HVAC and roofing systems in the 2031 timeframe.

NORTHSIDE CENTER 106 GLAZNER ST. EASLEY, SC 29640 Adult Learning Facility Number of Classrooms Maximum Capacity Recommended Capacity Current Enrollment Current % recommended capacity 11,676 sf Property is 1.45 acer parcel #5019-12-95-8424 Property is 0.43 acres pervious Original facility constructed in the 1920 s HVAC system is 2 gas/electric packaged units installed in 2000. Facility has no emergency power generation capabilities. Fire Alarm system is manufactured by First Alert was installed in 2005. It does not meet code. The facility has no fire sprinkler system. The roof is architectural shingle installed in 2014. Facility energy consumption: 68.11 kbtu s per sq. ft. @ $21,524 per year Fort Hill Facility is not up to ADA, Fire or Energy code. Facility has no insulation. HVAC requires replacement in the next few years. Windows and lighting require replacement. Facility has no insulation. Insulation should be installed. Paved parking is needed. Upgrade to LED lighting fixtures

B. J. SKELTON CENTER 1400 GRIFFIN MILL RD. EASLEY, SC 29640 Transportation/Student Nutrition Support Facility Number of Classrooms Maximum Capacity Recommended Capacity Current Enrollment Current % recommended capacity 25,000sf Property is shared parcel with Central Services Original facility constructed in the 1978 HVAC units are a combination. Heat pumps installed in 2006 and Gas/electric packaged units installed in 2012. Facility does not have emergency power generation capabilities. Fire Alarm system is manufactured by Fire Lite and was installed in 2012. The facility has no fire sprinkler system. Roof is built-up installed in 2012. Blue Ridge Cooperative Fort Hill Bethlehem-Roanoke District Septic system Replace fencing.

CENTRAL SERVICE OFFICE 1348 GRIFFIN MILL RD. EASLEY, SC 29640 District Administration Facility 16,210sf including portable office space. Number of Classrooms Maximum Capacity Recommended Capacity Current Enrollment Current % recommended capacity Property is 112.0 acer parcel #4099-08-88-7452 Property is 89.6 acres pervious Original facility constructed in 1973 HVAC units are gas/electric packaged rooftop units installed in 1999. Facility does not have emergency power generation capabilities. There is no Fire Alarm system in this facility. The facility has no fire sprinkler system. Roof is built-up installed in 2 phases. North section in 1998 and south section in 2010. Blue Ridge Cooperative Fort Hill Bethlehem-Roanoke District Septic system HVAC system has reached the end of useful life. Paving is deteriorating. Additional parking is needed. Facility needs renovation for ascetics and code issues. Funding for HVAC replacement should be planned. Replace section of roofing in finance wing.

DISTRICT OPERATIONS COMPLEX 415 ANN ST. PICKENS, SC, 29671 District Operational Support Facilities Number of Classrooms Maximum Capacity Recommended Capacity Current Enrollment Current % recommended capacity 30,108 sf Property is 4.00 acer parcel #4181-11-66-7677 Property is 0.20 acres pervious Facilities several surplus SCDOT buildings dating back to the 1920 s. HVAC system are a variety. Facility emergency power generation capabilities in Office/AITS building only. There is no Fire Alarm system. The facility has no fire sprinkler system. The roof systems are metal and shingle. Metal roofing was installed in 1998 shingles were installed in 2014. Duke Energy Fort Hill Pickens City Pickens City Pickens City Aging on site underground fuel storage tanks. Road construction beginning in spring of 2016. Loosing parking to road construction.

EASLEY BUS PORT/OFFICE 105 STEWART DR. EASLEY, SC 29640 Transportation Office Number of Classrooms Maximum Capacity Recommended Capacity Current Enrollment Current % recommended capacity 1,536 sf Property is 3.46 acer parcel #5029-15-53-9719 Property is 0.17 acres pervious Facilities consist of 2 portable office units. HVAC system is air to air heat pumps. Facility has no emergency power generation capabilities. There is no Fire Alarm system. The facility has no fire sprinkler system. The roof is shingle installed in 1998. not on site

PICKENS BUS PORT/OFFICE 688 PUMPKINTOWN HWY. PICKENS, SC, 29671 Transportation Office Number of Classrooms Maximum Capacity Recommended Capacity Current Enrollment Current % recommended capacity 1,536 sf Property is 4.00 acer parcel #4191-06-29-6367 Property is 0.21 acres pervious Facilities consist of 2 portable office units. HVAC system is air to air heat pumps. Facility has no emergency power generation capabilities. There is no Fire Alarm system. The facility has no fire sprinkler system. The roof is shingle installed in 1998 and metal. Duke Energy not on site Pickens City Pickens City Pickens City Bus parking areas are in poor condition and require repaving. Bus parking area need to be fenced. Replace old metal portable. Repave as soon as possible. Fence bus lot. Evaluate the portables.

LIBERTY-DANIEL PORT/OFFICE 1037 JOHNSON RD. CENTRAL, SC 29630 Transportation Office Number of Classrooms Maximum Capacity Recommended Capacity Current Enrollment Current % recommended capacity 1,536 sf Property is 5.30 acer parcel #4066-00-99-7037 Property is 0.27 acres pervious Facilities consist of 2 portable office units. HVAC system is air to air heat pumps. Facility has no emergency power generation capabilities. There is no Fire Alarm system. The facility has no fire sprinkler system. The roof is shingle installed in 1998. Duke Energy not on site Easley-Central District Septic System Bus parking area needs to be fenced. Fence the bus lot.

DISTRICT INSIDE STORAGE CENTER 467 SPARKS LN. PICKENS, SC, 29671 Surplus Property Number of Classrooms Maximum Capacity Recommended Capacity Current Enrollment Current % recommended capacity 93,861 sf Property is 37 acer parcel #4181-08-99-1865 Property is 11.92 acres pervious Original facility constructed in the 1960 s. The science wing was added in 1983. HVAC system is not functional. Facility has no emergency power generation capacity. Fire Alarm is manufactured by Simplex and was installed in 1985. it is not operational. The Facility has no fire sprinkler system. Roofing system is a built-up. Facility is utilized as the Districts storage facility. Duke Energy Fort Hill Pickens City Pickens City Pickens City

OTHER DISTRICT OWNED PROPERTIES 304 West D Ave. Easley, SC 29640 2.24 Acre parcel # 5019-11-65-4675 Property is currently leased to Head Start of Easley. Lease to expire 5/30/2022 714 West Main St. Central, SC 29630 0.58 acre parcel #4065-10-35-5503 Property is currently leased to Central Community Center. Lease expires??/??/20?? 201 South D St. Easley, SC 29640 1.89 acre parcel #5019-15-63-8014 Currently leased to City of Easley Lease to expire 5/30/2022 McAlister Rd. Easley, SC 29640 0.42 acre parcel #5028-07-78-2244 Currently surplus and for sale.