XET-20 Series 20 Amp Emergency Lighting Control Device

Similar documents
HIGH BAY APPLICATIONS

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

SERVICE BY QUALIFIED PERSONNEL ONLY

diode led 12VDC OMNIDRIVE 2 ELECTRONIC SPECIFICATION SHEET 12VDC OVERVIEW FEATURES DIMMABLE DRIVER

MODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATION ! IMPORTANT SAFEGUARDS!

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Installation Instructions

SECTION. Occupancy Sensors & Lighting Control Products

LED RETROFIT CONVERSION KITS

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

ESRB and ESRN Installation & Safety Instructions

LED ECO PANEL.

Phase-Adaptive Power Module

WARRANTY LED ECO PANEL.

Emergency Lighting. Product Guide LED. The right source for the. right light

Product Bulletin for Decora Rocker Slide Controls

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

LED RETROFIT CONVERSION KITS

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Versatile wall switch sensors maximize payback and simplify code compliance

Unison Echo Room Controller

Applied Lighting Controls

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

AddressPro Digital Dimming Technical Product Information

miniz Quick Start Guide

Obstruction Lighting Controller Manual

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Emergency TLED Lighting Retrofit 101. December 6 th 2017

Honeywell ENERGY SAVINGS KIT

USER MANUAL INSTALLATION GUIDE FOR: 2X2: MLFP22DS4035 MLFP22DS4041 MLFP22DS4050

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

THINTEK G2 PANEL.

THINTEK G2 PANEL.

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

HBEAM 1.25 PRE-DESIGNED HB1.25 PRE-DESIGNED STRAIGHT SECTIONS (2FT - 8FT)

S5JB Quick Setup Guide. Refer to the instructions on the following pages for complete details on the steps outlined below.

CDL8 LED Architectural

False Ceiling HF Sensors

DIAGNOSTIC GUIDE LESS DRY TEST

AlphaTECH LED STRIP LIGHT

Related Sections: TBD. Effective Date: January 1, 2016

BALLAST SOURCE EB- Electronic ballast BALLAST QUANTITY. 1-(1) 4-light ballast LAMP SPECIFICATIONS SPECIFICATIONS

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

Catalog Number. Notes

Vive PowPak Fixture Controls

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

LED Control Solutions

Honeywell Durafit LED Retrofit Kit

For more information, please visit 3-form.com or call

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

Stellar Panelboard Dimming Systems

Application Note #106 Revision D June Emergency Lighting. Overview


TROFFER RETROFIT KIT (TRK)

IP65 High Bay Dual Sense Sensor

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

NYC Approved Product Series

Tri-level Control Sensor

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

Product Specifications Warning Light Control Cabinet

ARCHITECTURAL DIMMING PANEL - MAIN/SECONDARY

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

Bdl60u Fluorescent Emergency Ballast

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

600 Watt Dimmer Install Guide

SDL4 LED Strip Diffused Lens

BAS SDL8' LED Strip Diffused Lens

Installation Instructions

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

Dimensions (111mm) (111mm) 3 (76mm)

Nightfall. led emergency egress lighting

STATUS ALARM HISTORY ALARM RESET

1 General Description

East Central College

LED RETROFIT SOLUTIONS

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

APPENDIX E LIGHTING CONTROL DATA

IP65 High Bay Dual Sense Sensor

National Grid Small Business Program Rebate Manual

SPECIFICATIONS Compliance & Regulatory Approvals DIMMER MODELS TRIM PLATES (SOLD SEPARATELY) SYSTEM DIAGRAM. Input. Output. Environmental Requirements

WIRING GUIDE. Form rev.1. Certified to CSA C22-2 No.24 Conforms to UL Standard 873

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

Transcription:

XET-20 Series 20 Amp Emergency Lighting Control Device The Exitronix XET-20 Emergency Lighting Control Device allows the use of auxiliary generator or inverter power on switched fixtures in power failure situations. The XET-20 senses the loss of normal AC power and bypasses local control devices such as switches, on/off occupancy sensors, or timers, providing emergency power to the fixtures regardless of the control setting. The XET-20 allows for operation of the load at full light output until normal power is restored or for as long as the generator or inverter supply is available. The XET-20 will work in conjunction with any fixture on the designated 20 Amp circuit per the rated specifications. Allowing for the use of switched fixtures with a generator or inverter supply eliminates the need for night lights and promotes increased energy savings. Dimming relay model available to accommodate dualzone dimming (Ref XET-20-DR spec). TECHICAL SPECIFICATIOS Input Voltage: 120/277V, 50/60Hz Maximum Load Ratings: LED driver: 8A @120VAC, 50/60Hz per EMA 410 8A @277VAC, 50/60Hz per EMA 410 Ballast: 20A @ 120/277VAC, 50/60Hz Incandescent: 10A @ 120VAC, 50/60Hz In-rush Current Rating: 221A for 1.25ms @ 120VAC 370A for 1.25ms @ 277VAC Emergency Operation: The XET-20 will operate in conjunction with any lighting load as noted in the specifications in the designated 20 Amp circuit for the duration of the auxiliary supply Weight: 1.0 lbs Operating Temperatures: -20 C to 55 C (-4 F to 131 F) Model: Accessories: Job ame: Date: Type: FEATURES alvanized steel housing LED indicators for determining functional readiness and operation modes Rated for LED loads of up to 8 Amps continuous as per EMA 410 Simplified junction box installation with 10" leads Suitable for use in plenum and damp location applications Jumper loop for connection to alarm, security panel, or other remote trigger device Dual-Zone dimmer bypass model also available (Reference XET-20- DR specification sheet) LOADS OPERATED Allows operation of switched fixtures from the generator or inverter supply PRODUCT ADVATAES Allows operation of switched or dimmed fixtures on an auxiliary generator or inverter supply Promotes energy savings by eliminating the need for multiple always-on fixtures Full light output COFORMACE TO CODES & STADARDS Meets or exceeds all EC, IBC, and Life Safety code emergency lighting requirements UL and CUL 924 Listed for Damp Locations UL 2043 Plenum Rated WARRATY The Exitronix XET-20 is warranted for five years from date of shipment. The warranty does not cover physical damage, abuse or instances of uncontrollable natural forces. See the full Exitronix warranty document for detailed information. Ordering Information SKU Description UL Part umber XET-20 Emergency transfer switch, 20 Amps switching current ETS-20

WIRI DIARAM XET-20 FOR UL 1008 SWITCH EAR CIRCUIT SESOR SESOR COTROL DEVICE SESOR BLUE - REMOTE DEVICE JUMPER (OPTIOAL) OUTPUT EM IPUT EM IPUT COTROL DEVICE (Wall Switch, Timer, Occupancy Sensor) OLY COECT WITH A REMOTE DEVICE SUCH AS A FIRE ALARM OR SECURITY AD Typical Application During presence of normal power, the XET-20 senses the setting of the O/OFF control device through the red wire (Control Device Sensor) and operates the ormal/em mode accordingly. When normal power is lost, the XET-20 allows operation of the ormal/em load at full output from the auxiliary supply, regardless of control device status. FOR XET-20 with Dimmer Controls FOR UL 1008 SWITCH EAR CIRCUIT Dimmer SESOR SESOR COTROL DEVICE SESOR BLUE - REMOTE DEVICE JUMPER (OPTIOAL) OUTPUT EM IPUT EM IPUT Dimmer OLY COECT WITH A REMOTE DEVICE SUCH AS A FIRE ALARM OR SECURITY AD ormal/em Dimmer Control The XET-20 can be used with dimming applications by adding a second dimmer device to the designated EM circuit. In this scenario, both the EM circuit and XET-20 power output are connected to the load. The red Control Device Sensor of the XET-20 remains disconnected and there is no power output from the XET-20 unless normal AC power is lost. If emergency power is activated, the XET-20 will then route power around the dimmer on the EM circuit. FOR DIMESIOS 4.6 0.5 5.6 Specifications are subject to change without notice. Installation must be performed in accordance with Barron Lighting roup installation instructions. 10800309 REV-2 03/18 800.533.3948 www.barronltg.com

XET-20-DR Series 20 Amp Emergency Lighting Control Device with Dimming Relay The Exitronix XET-20-DR Emergency Lighting Control Device allows the use of auxiliary generator or inverter power on switched fixtures in power failure situations. The XET-20-DR senses the loss of normal AC power and bypasses local control devices such as switches or dimmers, providing emergency power to the fixtures regardless of the control setting. The XET-20-DR allows for operation of the load at full light output until normal power is restored or for as long as the generator or inverter supply is available. The XET-20-DR will work in conjunction with any fixture on the designated 20 Amp circuit per the rated specifications. Allowing for the use of switched fixtures with a generator or inverter supply eliminates the need for night lights and promotes increased energy savings. The dimming relay leads accommodate two 0-10 Volt dimming zone controls, providing full light output in both zones during emergency mode regardless of dimmer setting. Model: Accessories: Job ame: Date: Type: TECHICAL SPECIFICATIOS Input Voltage: 120/277VAC, 50/60Hz Maximum Load Ratings LED driver: 8A @120VAC, 50/60Hz per EMA 410 8A @277VAC, 50/60Hz per EMA 410 Ballast: 20A @ 120/277VAC, 50/60Hz Incandescent: 10A @ 120VAC, 50/60Hz In-rush Current Rating: 221A for 1.25ms @120VAC 370A for 12.5ms @ 277VAC Emergency Operation: The XET-20-DR will operate in conjunction with any lighting load as noted in the specifications in the designated 20 Amp circuit for the duration of the auxiliary supply Contact Rating: 1A @30VDC 1A @ 277VAC Weight: 1.0 lbs Operating Temperatures: -20 C to 55 C (-4 F to 131 F) FEATURES alvanized steel housing LED indicators for determining functional readiness and operation modes. Rated for LED loads of up to 8 Amps power as per EMA 410 standards Accommodates dual zone 0-10V dimming Simplified junction box installation with 10" leads Suitable for use in plenum and damp location applications Jumper loop for connection to alarm, security panel, or other remote trigger device LOADS OPERATED Allows operation of switched fixtures in dual dimming zones from the generator or inverter supply PRODUCT ADVATAES Allows operation of switched or dimmed fixtures on an auxiliary generator or inverter supply Promotes energy savings by eliminating the need for multiple always-on fixtures Full light output Dimming relay leads allows for dual zone dimming controls COFORMACE TO CODES & STADARDS Meets or exceeds all EC, IBC, and Life Safety code emergency lighting requirements UL and CUL 924 Listed for Damp Locations UL 2043 Plenum Rated WARRATY The Exitronix XET-20-DR is warranted for five years from date of shipment. The warranty does not cover physical damage, abuse or instances of uncontrollable natural forces. See the full Exitronix warranty document for detailed information. Ordering Information SKU Description UL Part umber XET-20-DR Emergency transfer switch with dimming relay, 20 Amps switching current ETS-20-DR

WIRI DIARAM The XET-20-DR provides two sets of dimming relays for use with dual Zone dimming (such as an auditorium that would demand full brightness on a platform and a dimmed zone over the audience). The XET-20-DR allows for two-wire dimming of zones that would be comprised of both normal and EM fixtures. In the event of a power loss, any dimmed emergency fixtures in either zone will switch to the emergency supply and come on at full brightness. OLY RAY VIOLET FOR ZOE 1 VIOLET LIE MASTER DIMMER COTROL RAY COTROL DEVICE BLUE - REMOTE DEVICE JUMPER (OPTIOAL) CUT BLUE JUMPER TO COECT WITH REMOTE DEVICE (OPTIOAL) XET-20-DR SESOR SESOR COTROL DEVICE SESOR BROW/WHITE (LY OPE 1) BROW (COMMO 1) BROW/BLACK (LY CLOSED 1) ORAE/WHITE (LY OPE 2) ORAE (COMMO 2) ORAE/BLACK (LY CLOSED 2) ZOE 2 LEADS DUPLICATE ZOE 1 COECTIOS FOR ZOE 2 DEVICE. OUTPUT EM IPUT EM IPUT UL 1008 SWITCH EAR CIRCUIT ZOE 1 AD VIOLET RAY FOR DIMESIOS 4.6 5.6 Specifications are subject to change without notice. Installation must be performed in accordance with Barron Lighting roup installation instructions. 10800307 REV-2 03/18 800.533.3948 www.barronltg.com

XET-3 Series 3 Amp Emergency Lighting Control Device The Exitronix XET-3 Emergency Lighting Control Device allows local switch control of designated emergency luminaires when emergency power is provided by a generator or inverter. The XET-3 senses the loss of normal AC power and bypasses the local switch device allowing emergency power directly to the fixture regardless of switch position. The XET-3 is rated for any lamp load up to 3 Amps continuous power including LED loads per EMA 410 standards. The XET-3 is an ideal solution for achieving increased energy savings in accordance with most energy efficiency standards by eliminating the need to operate the designated emergency fixtures 24/7 when emergency power is sourced from a generator or inverter. Dimming ballasts require one XET-3 for each hot lead. Model: Accessories: Job ame: Date: Type: TECHICAL SPECIFICATIOS Input Voltage: 120/277VAC, 60Hz Input Current: 250mA Maximum Switching Voltage: 3 Amps @ 120/277VAC Circuit Protection: 3A on Control Input 3A on eutral and 120/277VAC Outputs In-rush Current Rating: 144A for.89ms @ 120VAC 258A for.98ms @ 277VAC Emergency Operation: The XET-3 allows operation of any lamp type in the designated fixture for the duration of the auxiliary supply Initial Illumination: The XET-3 allows operation of the designated load at full light output Weight: 1.0 lbs Operating Temperatures: 0 C to 50 C (32 F to 122 F) FEATURES alvanized steel housing Optional 24" flex conduit available (XET-3-FC) Rated for LED loads up to 3 Amps continuous as per EMA 410 Dual Voltage 120/277VAC, 60Hz Rated for use in plenum and damp location applications LOADS OPERATED Allows full light output operation of any LED, fluorescent, or incandescent switched fixture from the generator or inverter supply up to 3 Amps continuous. PRODUCT ADVATAES Regain local switch control of your designated emergency fixtures powered from a generator or inverter Promotes energy savings by eliminating the need for always-on fixtures Full light output COFORMACE TO CODES & STADARDS Meets or exceeds all EC, IBC, and life safety code emergency lighting requirements UL 924 Listed for Damp Locations WARRATY The Exitronix XET-3 is warranted for five years from date of shipment. The warranty does not cover physical damage, abuse or instances of uncontrollable natural forces. See the full Exitronix warranty document for detailed information. Ordering Information SKU Description UL Part umber XET-3 Emergency transfer switch, 3 Amps switching current ETS XET-3-FC Emergency transfer switch with 24" flex conduit, 3 Amps switching current ETS-R

WIRI DIARAM TYPICAL BALLAST/EERATOR APPLICATIO WHITE BLU/WHT ( COMMO) BLUE ( LIE) OR (277V) BLK (120V) COTROL DEVICE RED ( LIE) RED/WHT ( COMMO) XET-3 COTROL DEVICE WHT/BLK BLK/OR 120/277 VDC AC DRIVER / BALLAST /WHITE RED LED IDICATOR (OPTIOAL) SESE SELECT PROPER VOLTAE LEAD. CAP UUSED LEAD. TYPICAL DIMMI BALLAST/EERATOR APPLICATIO WHITE WHITE BLU/WHT ( COMMO) BLUE ( LIE) BLUE ( LIE) OR (277V) RED 3 WIRE DIMMI COTROL BLK BLK (120V) OR (277V) BLK (120V) RED ( LIE) RED ( LIE) RED/WHT ( COMMO) /WHITE RED LED IDICATOR (OPTIOAL) WHT/BLK XET-3 COTROL DEVICE BLK/OR BLACK BLACK AC DRIVER / BALLAST XET-3 COTROL DEVICE BLK/OR WHT/BLK RED/WHT /WHT BLU/WHITE 2 SESE. SELECT PROPER VOLTAE LEADS. CAP UUSED LEADS. COECT THE PROPER VOLTAE LEADS BEFORE DIMMER COTROL O THE LIE. 2 CAP UUSED LEADS. DIMESIOS 8.0 1.2 1.2 MOUTI CETER 7.5 FLEX (EXT-3 OLY) 24 Specifications are subject to change without notice. Installation must be performed in accordance with Barron Lighting roup installation instructions. 10800308 REV-2 03/18 800.533.3948 www.barronltg.com