The First 100+ Terms

Similar documents
Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

R-407A R-448A R-449A

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Chapter 2. Alternatives to HCFCs and their Characteristics

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Pressure Enthalpy Charts

Energy Use in Refrigeration Systems

RSES Technical Institute Training Manual 1 70 hours, 70 NATE CEHs, 7.2 CEUs

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Use this Construction/HVAC Glossary to answer the questions below.

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

Refrigeration Systems and Accessories

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Refrigeration Technology in Building Services Engineering

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Chapter 9. Refrigeration and Liquefaction

Positively Innovative R32 R32. Instructions for Use and Handling

Refrigeration Manual. Part 1 - Fundamentals of Refrigeration

How to deal with ...R410A MITSUBISHI ELECTRIC R32 R125 R410A AIRCONDITIO NING

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

(Refer Slide Time: 00:00:40 min)

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

R-404A Alternative with Low Compressor Discharge Temperature

March 10, 2016 San Joaquin Valley RETA Meeting

Solstice 452A (R-452A) Reduced GWP and Discharge Temperature for Transport Refrigeration, Plug-Ins and Condensing Units

The Essentials Of Working With R-410A

Purpose of Refrigeration

SIR C.R.REDDY COLLEGE OF ENGINEERING, ELURU DEPARTMENT OF MECHANICAL ENGINEERING ETD-II. Model Short Answer Questions And Answers

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Refrigerant changeover guidelines

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Scroll Chillers Transition from HCFC-22 to HFCs

Compendium DES July 2016, CARN

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Refrigerant Glide and Effect on Performances Declaration

CHAPTER 1 INTRODUCTION

Understanding Applications for Alternate Refrigerants. Ron Bonear Emerson Climate Technologies

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

CHAPTER 1 INTRODUCTION

Seminar 34 Refrigerants Today, Tomorrow, and Beyond

Material Safety Data Sheet SECTION 1: PRODUCT AND COMPANY IDENTIFICATION SECTION 2: INGREDIENTS SECTION 3: HAZARDS IDENTIFICATION

The Refrigeration Cycle

MECHANICAL ENGINEERING THERMAL AND FLUID SYSTEMS STUDY PROBLEMS

APPLICATION & SERVICE GUIDE

The Refrigeration Cycle

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK

USING THE P-T CARD AS A SERVICE TOOL

Thermo-physical properties found on most psychrometric charts

COMPARATIVE PROPERTIES AND EFFICIENCY OF R-421A FOR RETROFIT USE TO REPLACE R-22

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

2. CURRICULUM. Sl. No.

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

Worldwide Marine and Offshore Services A GUIDE TO RS REFRIGERANTS FROM STAR INTERNATIONAL. Second Edition

System Considerations for Refrigerant Blends with Temperature Glide

Commercial CO2 Refrigeration Systems. Guide for Subcritical and Transcritical CO2 Applications

Refrigeration and Air-Conditioning

REFRIGERANT CHANGEOVER

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

UNIT - 3 Refrigeration and Air - Conditioning

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

EMERGENCY PHONE: or (651) (24 hours)

Specifications for Fluorocarbon Refrigerants

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Brazed Plate Heat Exchanger for CO Applications

Chapter 10. Refrigeration and Heat Pump Systems

Thermodynamics II Chapter 5 Refrigeration

DIRA S.L. (Desenvolupament, Investigació i Recerca Aplicada S.L.)

HVAC Fundamentals & Refrigeration Cycle

HEATING, AIR CONDITIONING AND REFRIGERATION TECHNOLOGY COURSE SYLLABUS

EMERGENCY PHONE: or (651) (24 hours)

Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units

Cooling Fundamentals

Development of centrifugal chiller and heat pump using low GWP refrigerant

Appendix A. Glossary of Common Terms

Low Global Warming Refrigerants For Commercial Refrigeration Systems

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES

ISSN Vol.08,Issue.21, November-2016, Pages:

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 10 SYSTEM CHARGING

Commercial Refrigeration

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

UEE11 Electrotechnology. Training Package. UEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerants SAMPLE.

EMERGENCY PHONE: or (651) (24 hours) Ingredient C.A.S. No. % by Wt POLYPROPYLENE

Short Questions with Answers APPLIED THERMODYNAMICS(5 TH MECHANICAL) Chapter No-1

Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants

ANALYSIS OF LGWP ALTERNATIVES FOR SMALL REFRIGERATION (PLUGIN) APPLICATIONS

AMERICAN TRAINCO. CALL ( TRAIN) AMERICAN TRAINCO. Formerly Offered Through Martin Learning, Inc.

B. A. T. Basic Appliance Training

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

Hygrometry. The art or science of humidity observation

Transcription:

A collection of short pointed topical papers. September 2007 Whether it s Air Conditioning or Refrigeration by: Garth Denison Senior Application Engineer If you are viewing a copy, but would like to receive the monthly Cold W.A.R. directly, e-mail ColdWarSVD@parker.com to join our mailing list. The Sporlan Division of Parker Hannifin assumes no obligation or liability for any advice furnished or for any results obtained with respect to this information. All such advice is given and accepted at users risk. This disclosure of information herein is not a license to operate under, or a recommendation to infringe any patent of Sporlan Division of Parker Hannifin or others. 64 Registered trademark of Sporlan Division of Parker Hannifin, Washington, MO 63090 USA Copyright 2003 by Sporlan Division of Parker Hannifin, Washington, MO 63090 USA This document may be copied and distributed for educational purposes only. Cold W.A.R. Issue 064

Cold W.A.R. Issue 64 - Page 2 Accumulator: a device installed just before a compressor in the suction line that is used to separate vapor refrigerant from liquid refrigerant and lubricant. Adiabatic: describes a process such as compression of a refrigerant vapor without removing or adding heat. AEL: (Allowable Exposure Limit) recommended maximum human exposure to a substance. Alkylbenzene: synthetic chemical structure made from propylene and benzene. Aniline: a colorless, oily, benzene derivate used to make rubber, resins and varnishes. ANSI: American National Standards Institute Approach: the temperature difference between the leaving media and the leaving cooling source. ARI: Air conditioning Refrigeration Institute ASC: (Auxiliary Side Connector) a fitting used in conjunction with a distributor to allow Hot Gas into the evaporator or Liquid refrigerant out of the evaporator. ASHRAE: American Society of Heating, Refrigeration and Air conditioning Engineers. Azeotropic: a blend containing two or more refrigerants containing one common boiling point. Barometer: an instrument for measuring atmospheric pressure. Binary: a compound consisting of two single component refrigerants. Blend: a mixture consisting of two or more single compounds. Boyle s Law: states that for a fixed amount of gas kept at a fixed temperature, pressure and volume are inversely proportional. BTU: (British Thermal Unit) the heat required to raise or lower the temperature of one pound of water one Fahrenheit degree. Bubble Point: the point where the working fluid is 100% saturated liquid. BP: (Burst Pressure) minimum acceptable pressure which a refrigerant storage vessel can withstand without rupturing. Calorimeter: an apparatus for measuring the quantity of heat generated by friction, combustion or chemical change. Carnot Cycle: ideal thermodynamic cycle representing the maximum efficiency attainable from any heat engine. Carboxylic Acid: mild organic acid, family of fatty acids, a precursor in POE lubricants. Check Valve: a valve that only allows flow of refrigerant in one direction. CSA: Canadian Standards Association Chart: a sheet representing data in graph or tabular form. Compressor: a component in a refrigeration system that compresses refrigerant vapor to a higher pressure and temperature while consuming power to do so. Condenser: a component in a refrigeration system where refrigerant is condensed from a vapor to liquid and heat is rejected to the surroundings. COP: (Coefficient Of Performance) the measure of the refrigeration system s efficiency. Defined as the heat removed divided by the work to operate the system.

Cold W.A.R. Issue 64 - Page 3 Critical Point: highest point of the Ph curve, only single phase condition can exist above this point. It is the defining point between a gas and a vapor. Crystallization: the process of forming crystals, a change of state from a liquid to a solid. CST: (Critical Solution Temperature) saturated limit, can hold no more. Dalton s law: vapor pressure exerted on the walls of a container by a mixture of gases equals the sum of the individual vapor pressures of all gases in the mixture. De-gassing: the process of removing gas. Example, removing refrigerant from lubricant. Delta T ( T): the temperature difference between two points in the same media. Density: the mass of a substance divided by the volume that substance occupies. De-superheater: a device that removes sensible super heat from either the suction or discharge vapor. Dew Point: the point where the working fluid is 100% saturated vapor. Dielectric Strength: a measure of electrical insulating properties. Diagram: outline designed to explain or demonstrate how something works or clarify the relationship between the parts of a whole. Dihydrogen Monoxide: water, H 2 O. Discharge Line: a refrigerant line that carries superheated, high pressure refrigerant vapor from the compressor to the condenser. Distributor: a device that feeds two phase refrigerant evenly to each tube of a DX evaporator. DX: Direct Expansion evaporator where the refrigerant is in the tubes. Dynamic: ongoing, continuous. EER: (Energy Efficiency Ratio) the refrigeration effect in Btu s per hour per power input in watts. EWT: Entering Water Temperature Enthalpy (h): a thermodynamic property which defines the total useful energy in a substance. Entropy (S): a thermodynamic property which is a measure of energy which is no longer available to perform useful work. Esterification: ester is the name for a combined acid and alcohol. Exothermic Process: a process in which heat is liberated by chemical reaction. Ferrography: the study of wear particles in lubricants. Flash Point: the point where oil will give off flammable vapors when heated. Flocculent: flaky, waxy forms lumps or masses in lubricants. Fluoroproduct: a refrigerant composed of carbon and a fluoridated product, example R-22. Fractionation: a change in composition of a blend by preferential evaporation of the more volatile component or condensation of the less volatile component. GWP: Global Warming Potential of a specific substance as compared to CO 2.

Cold W.A.R. Issue 64 - Page 4 Hydrolysis: decomposition of a chemical compound by reaction with water. Hygroscopic: the ability to attract and retain moisture. Isobars: lines of constant pressure found on a Ph diagram. Isotherms: lines of constant temperature found of a Ph diagram. Latent Heat: heat that occurs with a change of state but no change in temperature. Only found in the two phase region of a substance. Lorenz Cycle: more applicable to interpretation, recognizes changes in temperature and pressure. MTD: Mean Temperature Difference is the average temperature difference of a temperature transfer process. Miscibility: the ability to mix. Mollier Diagram: the European version of the U.S. Psychometric chart. Naphthenic: refined crude oil forming a ring of carbons in its backbone. Neutralizer: a stabilizer that is added to an acid to make the acid inactive. ODP: Ozone Depleting Potential of a specific substance. Paraffinic: refined crude oil forming a straight chain carbons in its backbone. Peristalsis: wavelike movement to propel onward. Ph Diagram: a graphic representation of a specific refrigerants thermodynamic properties. Physical Properties: density, viscosity, boiling point, critical temperature, critical pressure, specific heat, thermal conductivity, ODP, GWP and flammability. Pipe: a fluid conduit that is measured by its inside diameter (ID). Polar In Nature: have an uneven electron balance along the backbone of the molecule. Poly Functional Alcohol: an alcohol / glycol, that is one of the precursor in POE lubricant. PPM: Parts Per Million Pressure (P): application of a continuous force by a fluid. Expressed in absolute units. Promatics: third category of mineral based lubricants, naphthenic and paraffinic most common. Psychometric: the study of the properties and measurements of air. Quality: the percent relationship between liquid and vapor present in a two phase region. Refined Product: manufactured from a natural composite compound, example mineral lubricant manufactured from crude oil. Refractive Index: the ratio of velocity of light in sample of lubricant to the velocity of light in a vacuum. Refractometer: an instrument that measures the bending of light from a straight line. Saturated Liquid: aka Bubble point, the point where the working fluid is 100% saturated liquid. Saturated Vapor: aka Dew Point, the point where the working fluid is 100% saturated vapor.

Cold W.A.R. Issue 64 - Page 5 SCT: Saturated Condensing Temperature SEER: Seasonal Energy Efficiency Ratio Sensible Heat (T): heat that can be measured by a thermometer. Single Phase: working fluid is either a liquid, a vapor or a gas. Solubility: the ability to dissolve. SST: Saturated Suction Temperature Sub-cooled: removal of sensible heat below a fluids saturated liquid point. Sublimation: changing directly form a solid to a gas without becoming a liquid. Specific Gravity: compares the density of oil with that of water, both liquids at 60ºF (15ºC). Superheat: addition of sensible heat above a fluids saturated vapor point. Synthetic: man made, always having consistent composition. TAN: Total Acid Number, milligrams of potassium hydroxide to neutralize a gram of oil. TD: Temperature Difference is the temperature difference between two points of different medias. Ternary: a compound consisting of three single component refrigerants. TEV: Thermostatic Expansion Valve TEWI: Total Equivalent Warming Index Thermodynamic Properties: temperature, volume, pressure, enthalpy and entropy. TIR: Total Indicated Reading Toxicity: the ability of a refrigerant to be harmful or lethal due to acute or chronic exposure by contact, inhalation or ingestion. Tribology: the study of friction and wear. Triple Point: working fluid exist in three states, they are solid, liquid and vapor in equilibrium. Tubing: a fluid conduit that is measured by its outside diameter (OD). TWA: Time Waited Average, when exposed to working fluids like refrigerants. Two Phase: working fluid is in two states, specifically liquid and vapor. UL: Underwriters Laboratory Vapor: a substance in a fluid state that can be condensed into a liquid. Viscosity: consistency or thickness of a fluid expressed in terms of resistance to flow. WC: (Water Capacity) the amount of water a refrigerant container can hold at 60ºF or 15ºC. Weir: a device used to control the behavior of fluid flow. Zeotropic: a blend containing two or more refrigerants without having a common boiling point.