4TM SERIES COMPRESSOR CONTROL Motor Protector Refrigeration Compressors

Similar documents
3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

SB/ESB SERIES THERMAL PROTECTORS

RP SERIES THERMAL PROTECTORS

5BT SERIES -65 F to 400 F, SPDT, Welded, Hermetically Sealed ½

4344 SERIES HERMETIC SEALED THERMOSTATS

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

SN5446A, 47A, 48, SN54LS47, LS48, LS49 SN7446A, 47A, 48, SN74LS47, LS48, LS49 BCD-TO-SEVEN-SEGMENT DECODERS/DRIVERS

D6T. Contactless measurement creating energy-efficient and comfortable living spaces. MEMS Thermal Sensors

MICRO SWITCH V15W Series Watertight Miniature Switches

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 4. Datasheet

V-Basic Standard V15 Series

Owner's Manual. Voltage Converter. Reverse. 110V to 220V STEP UP. For International Power Connectivity Converts U.S. 110V to Foreign 220V

Duct Mount. Installation Instructions

1NT SERIES Fixed Temperature Thermostats

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Wireless Panel-Mount Monitor

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 3. Datasheet

Apex MediTech ALC109 ALARM SYSTEM

Linear Current Sensors

Thermostat Catalog 2004

Open-area Smoke Imaging Detector. Engineering Specification

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Model Number Structure

Bimetal Disc Thermostat. Product Information and Application Notes

M52 3-Phase INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

ProAir CR43 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

M7100 Pressure Transducer

ion Genesis Pump Controller

GENESIS AIR CONDITIONERS

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

* Consult factory on conditions for approval acceptability

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

HFX Fiber Optic Component 50 Mbps, 650 nm LED

HIH-5030/5031 Series Low Voltage Humidity Sensors

Intrinsically Safe Transmitters, Option Code 2n

FreezGard. Self-regulating crankcase heater. Product Overview

INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

STEVAL-ISV020V1. Evaluation board for SPV1050 ULP energy harvester and battery charger buck-boost configuration. Description. Features.

KILOVAC K1K High-Voltage Contactor

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Environmental Monitoring SmartSlot Card

FSS-SMT Series. Low Profile Force Sensor

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

50TM TFF COMBINATION HEATING/COOLING UNITS


ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

Thermostat Catalog 2004

MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

n/a SN74LS47N BCD TO 7 SEG DECOCDER (RC)

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Switches & Sensors FOR VALVES & ACTUATORS

ProAir CR29 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Model 4001 Series Single Channel Controller

Incutrol/2 Regulator

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

Products :: Circuit Protection :: Thermal Circuit Breakers

50TM COMBINATION HEATING/COOLING UNITS

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

ProAir CR23 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

36T. Bimetal Disc Controls & Limits. Introduction

Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Designer & Application Notes. Securtiy Termination. belfuse.com/cinch

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Hazardgard. Product Profile. Engineered to perform in the harshest environments. Hazardous Location Room Air Conditioners

Installation and Operations Manual

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

PolySwitch TS600 Overcurrent Protection Devices

MICRO SWITCH GLL Series

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

onlinecomponents.com

Carwin COMPRESSOR SELECTION PROGRAM

HIH-4602-L Series Humidity Sensors

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Scale 0: 10 k Scale 50: 10 k (see note 2)

I/O ZONE 560/583 AND OPERATION MANUAL

THERMAL MANAGEMENT SOLUTIONS

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

MODEL 834M1 ACCELEROMETER

MICRO SWITCH E6/V6 Series

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Thermostat KPU. Data sheet

DOE and EPA Impacts to Commercial Refrigeration

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

AE R4 July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors

Transcription:

4TM SERIES COMPRESSOR CONTROL Motor Protector Refrigeration Compressors Product Overview Plug-on thermal motor protector for compressors Protects compressors for refrigerators, freezers, dehumidifiers, water coolers, vending machines, and similar refrigeration applications Compatible with PTCR starters and electromechanical relays Product designed and manufactured in an enviroment of Total Quality Control Applicable to compressors manufactured around the world Conforms with worldwide certification agency standards Benefits Cost Quality Performance The 4TM s plug-on feature and our fully automated manufacturing module provide 4TM customers with lower total installed cost. Sensata has designed quality into the 4TM product and process to meet a quality standard based on Statistical Process Control techniques. The basic function of the 4TM is to protect the motor in a refrigeration compressor from overheating, resulting from locked rotor or running overload conditions. The 4TM provides this protection by sensing the current and temperature of the motor. The fundamental actuation principle incorporates a noncurrent carrying snap-acting disc, which is located above the heater element. (REFER TO BACK PAGE FOR REFERENCE DRAWINGS). In addition to radiant heat generated from the heater, compressor shell, and ambient, the disc senses the heat from the metal pin carrying line current through the hermetic terminals. When the disc snaps, it actuates the spring arm located above the disc, opening the contact circuit which shuts off the compressor motor. The operating parameters of the 4TM are not affected by contact wear because the contacts are not part of the resistance circuit and are not part of the temperature calibration mechanism. The design features of the 4TM performance and reliability are the following: The variability to increase offtimes allows for matching and compatibility with PTCR starters Repeatability of trip time and ultimate trip Reduced temperature drift over life cycles Resistance to physical and thermal shock Page 1

Contact Capacity (Cycle Life Guidelines) The 4TM is designed to achieve a minimum of 10,000 cycles as defined by a Weibull analysis of test results. End of useful design life is defined as open or permanently closed circuit, and a change in open temperature of greater than ±5 C or a change in reset temperature of ±9 C from the device s original value. Test conditions are: Contact ZZ YY Max Current 32 Amps 20 Amps Operating Voltage 120 240 Power Factor 65% 65% These guidelines are intended to direct users toward a proper selection of contact capacity for specific applications and judgment of acceptability of cycle rate on an application relative to their specific goals for cycle life reliability. It presumes that the heater capacity has not been exceeded, and only published combinations of open and reset temperatures are used. Estimates of life of a given 4TM rating, in combination with a given compressor, may be obtained from a Sensata Technologies Sales/Marketing representative. It is incumbent upon the user to determine the reliability of the combination by actual locked rotor life test of the system. SPECIFICATIONS Notes on Code Heaters: Coiled heaters are preferred for PTCR-starter type applications because they provide longest off time; however, their ratio of first cycle trip time amps to ultimate trip amps is greater than flat heaters (approx. 4:1). The coiled heater series can cover a range of U.T.A. at 71 C from 0.7 amps to 5 amps. Flat heaters are preferred for relay type applications due to their narrower ratio of trip time current to ultimate trip current (approx. 3:1) flat heaters can cover a range of U.T.A. at 71 C from 0.9 amps to 8 amps. Temperatures: On the next page is a list of standard operating temperatures, and each has ±5 C tolerance on open temp and ±9 C tolerance on reset temperature. Consult your local Sensata Sales/ Marketing representative for special requirements. * Failure to properly apply the 4TM could result in actuation of the device when the compressor should be operating, or overheating of the motor during a Contact fault condition. Page 2

4TM Operating Temperatures Temperature Code Norminal Open Nominal Close JDB 100.0 52.0 KDB 105.0 52.0 KFB 105.0 61.0 LDB 110.0 52.0 LFB 110.0 61.0 MDB 115.0 52.0 MFB 115.0 61.0 MHB 115.0 69.0 NFB 120.0 61.0 NHB 120.0 69.0 PFB 125.0 61.0 PHB 125.0 69.0 REB 130.0 57.0 RFB 130.0 61.0 RHB 130.0 69.0 RLB 130.0 78.0 SFB 135.0 61.0 SHB 135.0 69.0 SLB 135.0 78.0 TFB 140.0 61.0 THB 140.0 69.0 TLB 140.0 78.0 UFB 145.0 61.0 UHB 145.0 69.0 ULB 145.0 78.0 VFB 150.0 61.0 VHB 150.0 69.0 VLB 150.0 78.0 VPB 150.0 87.0 WHB 155.0 69.0 WLB 155.0 78.0 WPB 155.0 87.0 XHB 160.0 69.0 XLB 160.0 78.0 XPB 160.0 87.0 Page 3

PARTS AND DIMENSIONS Dimensions in mm [See Conversion Chart Below] Page 4

ORDERING OPTIONS Example : 4TM 330 KFB YY-53 Basic Name for Thermal Protector 4TM WWW XXX YY ZZ Three Digit Heater Code Coil - 100 thru 499 Flat - 700 thru 899 Three Letter Code Designates Disc, Operating Temperatures, and Tolerance 1st Letter: Opening Temperature 2nd Letter: Closing Temperature 3rd Letter: Tolerance Denotes Contact Capacity 1st Letter Indicates Stationary Contact 2nd Letter indicates Movable Arm Contact Y - Low Capacity (Rated 20 AMP) Z - High Capacity ( Rated 32 AMP) External Terminations (Male Quick Connects) AGENCY APPROVALS & CERTIFICATIONS UL/Canadian-UL Component Recognition: File E15962 DEKRA/ENEC Compliance Certification # 2014531.15 CQC Certification: 09002034936 REACH Compliant RoHS Complaint Page 5 Sensata Technologies, Inc. ( Sensata ) data sheets are solely intended to assist designers ( Buyers ) who are developing systems that incorporate Sensata products (also referred to herein as components ). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED AS IS. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata s terms and conditions of sale supplied at SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev:05/08/18 CONTACT US Americas +1 (508) 236-2551 electrical-protection-sales@sensata. com Europe, Middle East & Africa +31 (74) 357 8156 info-sse@list.sensata.com Asia Pacific EP_Asia_Public@list.sensata.com China +86 (21) 2306 1651 Japan +81 (45) 277 7104 Korea +82 (53) 644 9685 India +91 (40) 4033 9611 Rest of Asia +65 (6478) 6860