Installation Instructions Exhaust Fan With Light

Similar documents
Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

INSTALLATION MANUAL AND USER GUIDE

INSTALLATION MANUAL AND USER GUIDE

INSTALLATION INSTRUCTIONS

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

INSTALLATION INSTRUCTIONS

HUMIDITY SENSING BATH FAN

VENTILATION FAN / LED LIGHT

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

VENTILATION FAN WITH LIGHT AND HEATER

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

e Bath Fan with Light User s Guide

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

breeze easytm model # F100-1W

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Please Read and Save These Instructions Safety Information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

e Heater/Exhaust Fan/Light User s Guide

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

VENTILATION FAN WITH BLUETOOTH SPEAKER

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

Use, Care, and Installation Guide

CONTENTS WIRING DIAGRAM

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

Owner and Maintenance Guide Models Equipped with K250 Blower

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

Bathroom Exhaust Fan/Fluorescent Light Combination

Bathroom Exhaust Fan/Fluorescent Light Combination

Insulated Ventilators. Operating Instructions & Parts Manual

READ AND SAVE THESE INSTRUCTIONS

Installation. Professional Built-in Hoods

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

READ AND SAVE THESE INSTRUCTIONS

Pro Ventilation Hood Liners

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

Installation Instructions Preference Wall Mount Range Hood

APPUZO RANGE HOOD INSTALLATION

UNDER CABINET RANGE HOOD

High Power Range Hood

Operating and Installation Instructions

Bathroom Exhaust Fan

Owner and Maintenance Guide for M Line Range Hoods with M600/M1200 Blowers

Use, Care, and Installation Guide

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the


INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Humidity and Thermostat control box for Attic Fan

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

Integrated Ventilation System

Installation Instructions Remote Blowers

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

Use, Care, and Installation Guide

Easy installation in both new construction and retrofit

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

PLEASE READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

PRO VENTILATION HOOD USE AND CARE GUIDE CLEANING, MAINTENANCE, AND MORE

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

Imperial. Read Before Starting Installation!

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Easy installation in both new construction and retrofit

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

Barcelona Collection. Use and handling instructions Mode d emploi et d entretien Instrucciones de uso y mantenimiento

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Installation Instructions

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

CLEANING & MAINTENANCE For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild d

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

PA 500/1100V Ultra Quiet Ventilation Fan

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

Use and Care & Installation Guide

Use, Care, and Installation Guide

Garage Ventilation Installation Instructions

Transcription:

Installation Instructions Exhaust Fan With Light MODEL 299651/BPT14-24AL READ AND SAVE THESE INSTRUCTIONS. Please read these instructions carefully before attempting to install, operate or service the ventilating fan. Failure to comply with instructions could result in personal injury and /or property damage. Please retain this booklet for future reference. TABLE OF CONTENTS Please read prior to installing this fan... 1 Mounting accessories... 2 Description... 3 Wiring diagram... 4 Specifications... 4 Unpacking... 4 General safety information & warnings... 4-5 Installation I (Joist Mounting)... 5 Installation II (In Existing Construction)... 6 Maintenance... 6-1 -

PLEASE READ PRIOR TO INSTALLING THIS FAN This line of ventilating fans employs state of the art technology providing a number of unique features that lead to improved in-door air quality. These features need to be fully understood prior to installation to realize the benefits the fans offers. Outstanding Energy Savings: This fan meets or exceeds the minimum ENERGY STAR requirements. MOUNTING ACCESSORIES MODEL 299651/BPT14-24AL Part name Appearance Quantity Decorative pan with light kit 1 Bulbs (GU 24 13W) 2 (Sold separately) Long screw 8 Screw I 4 Suspension Bracket I 2 Suspension Bracket II 2-2 -

DESCRIPTION This ventilating fan model uses a low noise fan driven motor. The motor is designed and manufactured to have an extended service life and operates very efficiently. There is a thermal cut-off for safety. DIMENSIONS No. Part Name No. Part Name 1 Finial 8 Connect screw 2 Glass shade 9 Gu24 bulbs 3 Socket 10 Support bracket 4 Grille 11 Fan body 5 Junction box cover 12 Blower wheel 6 Damper 13 Motor 7 Outlet - 3 -

WIRING DIAGRAM SPECIFICATIONS Model No. Air direction V HZ DUCT diameter (inches) Noise (sone) Power consumption (w) Speed (rmp) Air deliver at 0.1 WG (cfm) Weight (LB) 299651 / BPT14-24AL 110CFM 120 60 4 1.0 31 1120 110CFM 14.8 UNPACKING Unpack and carefully remove unit from carton. Refer to the Mounting Accessories list to verify that all parts are present. GENERAL SAFETY INFORMATION & WARNINGS 1. Electric Service supply must be 120V 60HZ. 2. Follow all local safety and electrical codes as well as NEC (National Electrical Code) and the OSHA (Occupational Safety and Health Act). 3. This unit must be properly grounded. 4. Always disconnect the power supply prior to servicing the fan, motor or junction box. 5. Do not bend or kink the power wires. 6. Do not install where the air temperature will exceed 40 C (104 F). 7. This ventilating fan is approved for use over a bathtub or shower when installed in a GFCI protected circuit. 8. Do not use to exhaust hazardous or explosive vapors. 9. Do not install in a cooking area. 10. Use this unit in the manner intended by the manufacturer. If you have any questions please call the manufacturer. Customer service number located on last page. 11. Installation work must be carried out by qualified person(s) in accordance to all local and safety codes including the rulers for fire-rated construction. 12. Sufficient air supply is required for proper combustion and the exhausting of gases through the chimney (flue) of fuel burning equipment to prevent back drafting. See the standards of NFPA (National Fire Protection Association) and ASHRAE (American Society for Heating Refrigeration and Air Conditioning Engineers) and the local building code authorities. 13. Exercise care to not damage existing wiring when cutting or drilling into walls or ceilings. - 4 -

14. Fans should always be vented to the exterior. 15. Do not use this fan with any solid state control device. 16. If this ventilating fan is installed over a tub or shower, it must be marked as approved for the application. 17. Prior to service or cleaning this unit, shut off power supply at the panel and lock to prevent the power from being turned on. If the panel cannot be locked clearly mark the panel with a warning tag not to turn on the power. 18. Do not install in a ceiling with insulation greater than R40. 19. Ductwork should be installed in a straight line with minimum bends. 20. Duct work size must be a minimum of the discharge and should not be reduced. 21. For UL:the fan is intended to be mounted at least 2.1m(7.0feet)above the floor. WARNING: Turn off electricity at breaker box before beginning installation. INSTALLATION I (JOIST MOUNTING) 1. Insert the suspension bracket into the fan body and adaptor (select the suspension bracket as shown below). (Fig.1) 2. Install the suspension bracket to joists by using long screws (M4x30). (Fig.2) 3. Refer to wring diagram on page 4. Using wire nuts, connect house power wires to ventilating fan wires: black to black; white to white; green to green. Replace the junction box cover. (Fig.3) Fig. 1 CAUTION: Mount junction box cover carefully so lead wires are not pinched. 4. Install a circular duct and secure it with duct tape or clamps. 5. Mount grille to fan body and install the 2 GU 24, 13W bulbs. (Fig.4) 6. Mount glass shade to grille by using connect screw and finial. (Fig.5) 7. Turn on electricity at breaker box after finishing installation. Fig. 2 Fig. 4 Fig. 3 Fig. 5-5 -

INSTALLATION II (IN EXISTING CONSTRUCTION) 1. Installation in existing construction. Installation the fan body in an existing building requires an accessible area (attic or crawl space) above the planned installation location or existing ducting and wring. (1) To install the fan body, follow the procedures described in installation I. Take the following precautions before installation. CAUTION: Check area above planning installation location to be sure that: 1. Duct work can be done and that are is sufficient for proper ventilation. 2. Wiring can be ran to the planned location. 3. No wiring or other obstructions shall interfere with installation. (2) Inspect duct work and wiring before proceeding with installation. (3) Plan suitable location for fan body. (next to ceiling joist) (4) Before installation, provide inspection and maintenance access at a location that will not interfere with installation work shown in installation I. (5) First, remove ceiling section. (6) Install fan body. (7) Continue from step 3-7 of installation I (page 5) to complete the installation work. 2. Installation from accessible area above fan location. (1) Inspect duct work and wiring before proceeding with installation. (2) Remove ceiling section. (3) Install fan body. (4) Continue from step 3-7 of installation I (page 5) to complete the installation work. MAINTENANCE ELECTRICAL WARNING Disconnect power supply before servicing. See General Safety (Page 4-5) in this manual before proceeding. Routine maintenance should be done at least once a year. Fig. 6 Fig. 7 CAUTION Never use benzene, thinner and any other such chemicals for cleaning the fan. Do not allow water to enter the motor. Do not immerse resin parts in water over 140 degrees Fahrenheit. 1. Unscrew finial to remove the glass shade. (Fig.6) 2. Wash and clean the glass shade in a sink and dry with a cloth. (Fig.7) 3. Remove dust and dirt from the fan housing with a vacuum cleaner. (Fig.8) 4. Dampen cloth with dish detergent and wipe the fan housing. Wipe dry with a cloth. (Fig.9) 5. Replace the glass shade. Fig. 8 Fig. 9-6 -