USER MANUAL. REVOLVE F20 (Repeat Cycle and Light Combo Timer ) AutopilotControllers.com APE2200

Similar documents
USER MANUAL. PEDESTAL FAN (16 Inch)

Hades 2. Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual. Notes: 1 Square = Foot/Feet

DDAC-1 deluxe digital atmosphere controller

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

saturn 5 Digital Environmental Controller with CO 2 Timer Instruction Manual Notes: 1 Square = Foot/Feet

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217


Operating Instructions

EOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

5) Do not start or stop the unit by inserting or pulling out the power plug.

saturn 5 Digital Environmental Controller with CO 2 Timer Instruction Manual Notes: 1 Square = Foot/Feet

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Operation Manual. An investment of a small amount of time to review this manual will ensure proper performance of your Coal-Trol Digital system.

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

7-Day. Digital Thermostat. residential. & 2-cool

Multiple use Digital Thermometer With 7 Day Memory

9,000 BTU Portable Air Conditioner PE1-09R-30. Model No. PE I-O9R Soleus Air International

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

Notes: 1 Square = 1 Foot

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Instruction Manual CHHC-1

Utopian Portable A/C

Spa Control System OWNER S MANUAL

FPO OWNER S MANUAL. Climate Comfort Anyplace Imaginable

ELECTRIC STOVE HEATER Models: FS2213B

ELECTRIC FLAT PANEL FIREPLACE HEATER

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION

Auto Opening with Pressure Readout 15 x15 & 16 x20 Heat Transfer Machines

Wall Hanging Mode. Pedestal Mode

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

12,000 BTU Evaporative Portable Air Conditioner

13500 BTU RV Air Conditioner Installation and Operating Instructions

Free your inner control freak.

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER

HEATER. Instruction Leaflet WITH ADVANCED TOUCHSCREEN CONTROL. pure indoor living MODEL: BCH9222-CN

OPTIONAL SLIT TUBING RECOMMENDED (AVAILABLE AT MOST HARDWARE STORES) Violet Grey. +12v Dash Lighting (See Lighting Mode)

ion Genesis Pump Controller

3M Overhead Ionizing Blower 991A

RK / RK Methane Detector Operator s Manual

Please Keep This Manual For Future Reference REV.01

User Guide AutoSealer 1001

5+2 Day. up to HEAT COOL

Programmable 5-2 Day Digital Thermostat

AIRTAP SERIES REGISTER BOOSTER FAN SYSTEM USER MANUAL

InstructIon Manual KrEs EQuIPMEnt stands

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

5+2 DAY PROGRAMMABLE DIGITAL THERMOSTAT

Portable Air Conditioner

failure is not an option

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

ELECTRIC FIREPLACE OWNER S MANUAL

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

OWNER S MANUAL

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Automatic Air-Operated Large Format Press

MGC Dock User s Manual

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

GA3650TB Blower Accessory

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

OZX-300ST Ozone Generator

OWNER'S MANUAL T0140. Contents Page #

EVAPORATIVE COOLER W

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

ARUBA SUN SERIES - LIGHTING SYSTEM USER MANUAL

Quest Power Electric Heat EHS 62 Pro

Instruction Manual EVC-2

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

Models WM1-06E-01 WM1-08E-01 WM1-10E-01 WM1-12E-01 WM1-12E2-01. Electronic Window Air Conditioner Operating Instructions V ,400 BTU 8,500 BTU

Instruction Manual. MODEL: FD1603 POWER SUPPLY: VAC, 60Hz or VAC, 50Hz POWER CONSUMPTION: 250W

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER (USA)

Environmental Monitoring SmartSlot Card

Model No. SG-PAC-10E2 Reference No. KY ,000 BTU Portable Air Conditioner Operating Instructions

Users Manual. Air Velocity Meter

Operator s Manual. The Quietek

FLCH4R Garage and Utility Electric Heater

CABINET INFRARED HEATER

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

User s Manual & Operating Instructions

INSTALLATION AND OPERATION INSTRUCTIONS

ELECTRIC FIREPLACE HEATER MODEL EF-BLT09 OWNER S MANUAL

IMPORTANT SAFETY INFORMATION:

Infrared quartz heater

Transcription:

USER MANUAL REVOLVE F20 (Repeat Cycle and Light Combo Timer ) APE2200 AutopilotControllers.com

AutopilotControllers.com 2

TABLE OF CONTENTS OVERVIEW 4 PARTS LIST - (WHAT S IN THE BOX) 5 LED DISPLAY & CONTROL SURFACE 6 OPERATING INSTRUCTIONS 7 LIGHT ON/OFF SETTING 7 RECYCLE TIMER SETTING 7 MAXIMUM TEMPERATURE SETTING 7 RECYCLE OUTPUT 7 NIGHT OUTPUT 7 MOUNTING INSTRUCTIONS 8 SECURE UNIT TO A WALL 8 SECURE UNIT TO A GROW TENT 8 GENERAL WARNINGS 9 SPECIFICATIONS 10 WARRANTY 12 3

OVERVIEW Thank you for purchasing the Autopilot REVOLVE F20 (APE2200) Repeat Cycle and Light Combo Timer. It controls lighting schedules and timed cycling functions in your grow area day and night with highly-reliable digital accuracy. The REVOLVE F20 has simultaneous dual timer functions, a 24- hour time clock for lighting, and a precise cycle timer for pumps, CO2 injection, exhaust fans, intake fans, etc. that allows you to dial in programming down to the second. REVOLVE F20 has four outlets. One outlet is equipped with a cycle timer designed to control a pump or any other cycling device; two outlets control daytime devices such as lights and light movers; and one outlet controls a nighttime device such as a heater, dehumidifier, or exhaust fan. These outlets feature heavy protective covers that prevent atmospheric moisture from entering the device through any unused outlets. The controller also features a high temperature shutdown function that detects unsafe high temperatures in the grow room and turns off the HID lights in the event of a ventilation failure. Additionally, the REVOLVE F20 has hot-start prevention to ensure proper cool down of lights before the device attempts to re-fire your valuable lamps. It also comes equipped with rubber feet on the back of the unit for added protection when mounted and optional U-brackets for tent mounting. NOTE: After turning on the power to the unit, it can take up to 5 minutes for the sensor to calibrate. NOTE: This controller has a 14.5A maximum load. For higher amperage devices such as A/C units, it is recommended to use a power expander. 8' (2.5 m) minimum TOOLS NEEDED (FOR OPTIONAL MOUNTING) Phillips Screwdriver 4

PARTS LIST - (WHAT S IN THE BOX) A - Controller Unit B - Sensor Unit C - Sensor Cord D - Power Cord E - Mounting Hardware(for walls) F - Mounting Hardware (for grow tents) E F A B D C 5

LED DISPLAY & CONTROL SURFACE (Turn light ON/OFF setting) (LIGHT 1 OUTPUT) (LIGHT 2 OUTPUT) (TEMP setting) (RECYCLE TIMER SETTING) (RECYCLE OUTPUT) (NIGHT OUTPUT) (POWER INPUT) (ON/OFF BREAKER) FUNCTION KNOBS Click knob, turn to set, press again to confirm (STATUS) Press both knobs for 3 seconds, set clock 6

LIGHT ON/OFF SETTING OPERATING INSTRUCTIONS NOTE: The unit s clock uses 24-hour military time format and not a.m./p.m. LIGHT ON TIME: Click the LIGHT ON TIME knob and turn to set your desired on time point, e.g. turn light on at 06:00 (6:00 a.m.). Click the LIGHT ON TIME knob again to save the setting. LIGHT OFF TIME: Set light off time the same way, using the LIGHT OFF TIME knob. Click the LIGHT OFF TIME knob again to save the setting. SET CLOCK: Press both knobs simultaneously and hold for 3 seconds to set the 24 hour time clock, press both knobs to save the setting. After the clock has been set, the internal battery will maintain the correct time even if there is an interruption of power. RECYCLE TIMER SETTING ON TIME: Click the ON TIME knob and turn to set. Set the hour setting first, then press again to set minutes, and finally seconds. Save the setting by pressing again. OFF TIME: Set off time by the same process, using the OFF TIME knob. NOTE: The display will count down by second in the last minute. TEST/OVERRIDE RECYCLE TIMER FUNCTION: This function can be used to quickly test the programmed cycle timer setting, or override the programmed cycle times. To test the programmed On Time cycle, press and hold the On Time knob for 3 seconds. To test the Off Time cycle, press and hold the Off Time knob for 3 seconds. MAXIMUM TEMPERATURE SETTING Click the MAX TEMP knob to set max temperature. Click the TEMP UNIT knob to choose Fahrenheit or Celsius. HIGH TEMPERATURE SHUTOFF This feature will shut off the supplemental lighting if the temperature in the growing area goes above the user-set maximum temperature setting. This will protect plants from excessive heat in the event of a ventilation failure or unusually high heat loads. For example, if the max temperature set point is 90 F/32 C, in the event the grow room temperature reaches this point, the light will be shut off. In the meantime, the top display (LIGHT) will count down a 15-minute lamp re-fire interval, and the middle display (TEMP C/ F) will flash the temperature repeatedly. When the room temperature goes down to 88 F/31 C (2 F/1 C less than the user-set max temp), and the 15-minute countdown has finished, the light will be re-fired. The 15-minute lamp re-fire interval is adjustable from 3 to 15 minutes by pressing the LIGHT OFF TIME knob for 3 seconds to enter the setting. To cancel the countdown, press and hold the LIGHT ON TIME knob, and watch as the controller fast forwards the re-fire countdown to zero. RECYCLE OUTPUT DAY mode: The outlet is only energized while the LIGHT ON mode is activated. 24 HOURS mode: The outlet is energized during day and night (during lights-on and lights-off). The setting should be entered from day/night mode. NIGHT mode: The outlet is energized only while the LIGHT OFF mode is activated. NIGHT OUTPUT This outlet is energized at all times when the LIGHT OFF mode is activated, and so any night device plugged into it such as a dehumidifier or fan will be continuously active during the lights-off period. 7

SECURE UNIT TO A WALL MOUNTING INSTRUCTIONS Secure the controller to the wall using the included mounting clips and screws. SECURE UNIT TO A GROW TENT Secure the controller to one of the grow tent s vertical support rods with the included U-bolt brackets. 1. Install on the inside of grow tent. 2. Install on the outside of grow tent (note that this method requires puncturing four holes 1 2 through the grow tent wall to allow the threaded ends of the U-bolts to emerge through the grow tent s fabric wall). 8

GENERAL WARNINGS 1. Save the instructions. These safety and operating instructions must be kept in a safe place for future reference. 2. Heed all warnings. All warnings on this product and in the instructions must be observed closely. 3. Follow all instructions. All operating instructions must be followed. 4. If the instructions as provided by the manufacturer are not followed, damage to the product itself may result. 5. Install your controller at least eight feet away from any devices that produce large amounts of electronic noise, such as electronic ballasts or ozone generators. 8' (2.5 m) minimum 6. Do not exceed the maximum power rating (120V/14.5A in) and do not plug in a device/devices requiring more than the max output current (14.5A). 7. Insert only NEMA 1-15P and NEMA 5-15P plugs into the receptacle on this device. Do not insert any other type of plug into it. 8. Do not use this controller near water. It is neither waterproof nor shockproof. 9. Do not use the device near any heat source. 10. This product is a Safety Class I Controller. Its main plug should only be inserted into power outlets that are properly grounded. SULFUR VAPORIZER WARNING If a sulfur vaporizer is used, first remove the remote sensor unit from the affected area or turn the controller off and cover the remote sensor probe with a protective plastic bag. Remove the bag before turning the power back on. Failure to protect the sensor while using a sulfur vaporizer will result in damage to its infrared component and will void the warranty. 9

SPECIFICATIONS Max amperage 14.5A @ 120VAC 60 Hz Power cord length 6.5' (2 m) Sensor cord length 15' (4.5 m) Lighting timer 24-hour timeclock Light re-fire setting 3-15 minutes Max temp setting Adjustable 85-115 F (30-46 C) Temperature accuracy ±2 F/1 C Recycling ON timer range 1 second to 24 hours Recycling OFF timer range 1 second to 24 hours Timer mode DAY/NIGHT/24 hours Weight 3.5 lbs (1.6 kg) Dimensions 8.0 x 3.3 x 7.5 (202 x 85 x 191 mm) Altitude Up to 6500' (2000 m) Operating Temperature 32 F to 122 F Maximum relative humidity 80% Pollution degree 2 IP degree IP 20 Indoor Use Only 10

11

WARRANTY LIMITED WARRANTY Hydrofarm warrants the APE2200 to be free from defects in materials and workmanship. The warranty term is for 2 years beginning on the date of purchase. Misuse, abuse, or failure to follow instructions is not covered under this warranty. Hydrofarm s warranty liability extends only to the replacement cost of the product. Hydrofarm will not be liable for any consequential, indirect, or incidental damages of any kind, including lost revenues, lost profits, or other losses in connection with the product. Some states do not allow limitation on how long an implied warranty lasts or the exclusion of incidental or consequential damages, so the above limitations or exclusions may not apply to you. Hydrofarm will, at our discretion, repair or replace the APE2200 covered under this warranty if it is returned to the original place of purchase. To request warranty service, please return the APE2200, with original sales receipt and original packaging, to your place of purchase. The purchase date is based on your original sales receipt. precise climate control Thank you for choosing Autopilot by Hydrofarm. For further information about Autopilot products, videos, and technical information, please visit AutopilotControllers.com ADDITIONAL LANGUAGES OF THESE INSTRUCTIONS CAN BE FOUND AT Hydrofarm.com Get Connected with the Hydrofarm Community: Like us on Facebook, follow us on Twitter, and check out Hydrofarmtv on YouTube and Instagram! APE2200 Instructions revised - January 8, 2018 11:26 AM Hydrofarm.com