Chore-Time Fan Guide For Tunnel and Other Applications

Similar documents
and SHUTTERS Made to Work. Built to Last.

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Greater temperature control

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

A. Codes and Standards that are Standard at the University:

Cages for Laying Hens. Our Experience. Your Success. Count on Chore-Time for experience, reliability, performance and confidence.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Direct Fired Heater Model AD Specification

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

CROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M)

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

AGRI-AIDE Ventilation Equipment. AGRI-AIDE Ventilation Key to Unlocking...

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Brooders. Better Brooding for Your Chicks... Since 1924

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

1.1 This section applies to air handling units for HVAC Systems.

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

Fans: Features and Analysis

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

GENERAL OBSERVATIONS FROM THE PHES EVALUATIONS TO DATE AVERAGE ANNUAL PROPANE USE

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Control Strategies and Considerations for Livestock and Other Farm Buildings

Panel Fan Series Operators Manual (Galvanized and Polymer)

Screw Compressors SM SERIES. Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig

VERTICAL FAN COIL UNITS

Ventilation. The idea behind our climate systems is efficiency and advanced simplicity.

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

Selecting the Correct Fan

SECTION (15833) - HVAC POWER VENTILATORS

Construction, Insulation, and Ventilation of Game Bird Facilities 1

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Plenum Fans. Model HPA. Direct Drive

User Manual Box Exhaust Fan Series (Belt Drive)

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

Evaporator EM-1. Features. V.1. Ceiling Mount Evaporators

Broiler Feeding System

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Breeder Pan Feeder. Pullet Feeder. Male Feeder

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

Chilled Water DOAS Fan Powered Terminal Units

What is a Closed circuit Cooling Tower (CCT)?

EVALUATION OF SWINE FACILITIES VENTILATION

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

POWERFUL CUSTOMIZED SOLUTIONS UNMATCHED QUALITY

Select an agricultural ventilation fan for the

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Modular Supply Make-Up Air Unit

Direct Gas-Fired Make-Up Air

Screw Compressors AS SERIES. Capacities from: 59 to 124 cfm Pressures from: 80 to 217 psig

The Advantages of Choosing Centrifugal Fans

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

SECTION AIR HANDLING UNIT

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS

TURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive)

Positive Pressure Filtered Swine Facilities

AcoustiFlo Fans: Retrofit Solutions and Beyond

Progressive Cavity Sewer Systems

EHH SERIES DRAW THROUGH FAN COILS CFM

SECTION AIR DUCT ACCESSORIES

How about Savings in Time, Money, Energy and Longer Life?

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

fans & heaters SIMPLE, ROBUST AND RELIABLE

Bulletin FH05 FUME EXHAUST

Double Skin Air Handling Units

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

Ventilate Your Swine Nursery Building

Multistage Centrifugal Blowers

Evaluation Report 509

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Day after day, Season after season, Generation after generation.

Product catalogue. Solutions for the Dairy segment

SELECTING A MOTOR MOTORS

Cumberland Heating Systems

Smart Comfort Solutions HIGH VELOCITY DRUM FANS

Series 5000 Industrial Modular Cooling Tower. Series 5000 Cooling Tower. engineering Data

Panel Fan Series Operators Manual (Galvanized and Polymer)

Fan Selection. and Energy Savings

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

Transcription:

Chore-Time Fan Guide For Tunnel and Other Applications Chore-Time s Fiberglass and Galvanized Fans Provide Efficiency and Performance Diameters available through 54 Inches (137.2 cm) Chore-Time s TURBO Fiberglass Fans feature a sturdy, reinforced-fiberglass housing with heavy cast-aluminum blade and corrosion-resistant components. Chore-Time s Galvanized Fans provide a great combination of performance and value. sm

Chore-Time Ventilation Fans When you grow with Chore-Time, you get the ventilation products you need to keep your birds healthy and productive. Chore-Time s Fans are put through rigorous testing at our on-site wind tunnel and rated by BESS Labs for performance. Whether you move more air with Chore-Time s HYFLO shutter (available on fans up to 54 inches/137.2 cm) or replace minimum ventilation sm fans with Chore-Time s efficient variable speed fans, you can optimize your air moving efficiency with the latest innovations from Chore-Time. Choose from these top-performing models: TURBO Fiberglass Tunnel Fans CHORE-TIME Galvanized Tunnel Fans 54-Inch Outside-Mount Galvanized Tunnel Fans HYFLO Shutters for Tunnel Fans Energy-Efficient Variable Speed Fans Box, Panel and Basket Fans For Supplemental Air Circulation TURBO Fiberglass Tunnel Fans Available in 52- and 48-inch Models (132.1- and 121.9-cm) Sturdy, corrosion-resistant fiberglass housing with heavy cast-aluminum blade, aluminum motor mounts and corrosion-resistant components. Motors are selected for each fan model to optimize its performance efficiency. Extensive motor testing is completed in our on-site wind tunnel under various operating conditions. PATENT PENDING Add Chore-Time's HYFLO Shutter for even greater efficiency. One-piece, impact-resistant, polyethylene cone. Automatic belt tensioner uses arm and pulley arrangement to provide consistent belt tension. Heavy-duty, cast iron, air-handler type bearings are selfaligning, pre-lubricated, and include a zerk fitting, as well as being shielded from moisture and dust. Fans are shipped fully assembled including shutter doors. At installation, simply attach fan to house sidewall, add one-piece cone, and snap grill in place. Unit installs flush on inside of house. Users may choose black or white for housing interior and cone. Housing exterior is white. Backed by Chore-Time s generous extended warranty including limited lifetime coverage for housing and blade, three years on shutter and cone, and two years on motor and bearings. (See Chore-Time s full written warranty for complete warranty details.) 2

Chore-Time Galvanized Tunnel Fans Available in 54-, 52- and 48-inch Models (137.2-, 132.1- and 121.9-cm) Factory-assembled using rugged, galvanized steel panels with screw fasteners and a galvanized steel blade. Chore-Time specifically selects the motor for each fan model to optimize its performance efficiency. Motors are then extensively tested in our on-site wind tunnel under various operating conditions. Automatic belt tensioning system uses an idler arm and pulley to maintain constant optimum belt tension on the fan s easy-to-change belt. Heavy-duty, cast iron, air-handler type bearings are self-aligning, pre-lubricated, and include a zerk fitting, as well as being shielded from moisture and dust. Chore-Time s HYFLO Shutter improves fan performance by minimizing obstructions during fan operation. 54-Inch (137.2-cm) Outside-Mount Galvanized Tunnel Fans Designed for more airflow or fewer fans with faster, more convenient installation Get More Airflow and Easy Installation with Retrofit Applications Easily replace older, inefficient 48-inch fans and get 30-35% more airflow. For replacement applications, mount to rough openings from most existing 48-inch through 54-inch fans. No need to reframe sidewalls or update wiring before installation in many cases. Fewer Fans for New Construction Mounts to the outside of the framed opening, using same sidewall opening as a 52-inch fan. Can be installed on 5-foot (1.5-m) centers. Tighter seal limits light and air leakage. Quieter operation. Chore-Time's 54-inch Fan can be mounted using existing 48-inch (shown in red) or 52-inch (shown in blue) framing. This eliminates the need to reframe sidewalls for retrofit applications. 3

Chore-Time s high-capacity 52-inch (132.1-cm) diameter TURBO Fan with HYFLO Shutter delivers more air with fewer fans 29,700 CFM at 0.05 inches of static pressure in independent wind tunnel tests. HYFLO Shutters for Tunnel Fans Available for Chore-Time s Fiberglass and Galvanized Fans Chore-Time s HYFLO Shutter improves fan performance by minimizing obstructions during fan operation. Delivers up to 10% more air than traditional shutters. 75% less opportunity for air to leak through compared to a traditional louver shutter. Does not suffer the typical 12-15% loss of efficiency and air speed typical of dirty louver-style shutters, so air speed is maintained over time. The HYFLO Shutter consists of only two moving parts for greater reliability and easier cleaning. (Patent Pending) Cable attachment allows HYFLO Doors to float left or right together for maximum efficiency. Shutter s unique springs draw the doors closed when fan is not in operation. HYFLO Shutter doors are pushed open as air is exhausted when fan operates. Variable Speed Fans Can Replace Minimum Ventilation Fans Chore-Time s 52" Galvanized Fan with HYFLO Shutter at 58% Typical 36-Inch Minimum Ventilation Fan 10,400 CFM 10,000 CFM 30.1 CFM/Watt 17 CFM/Watt Running tunnel fans at reduced capacity using Chore-Time s Variable Frequency Drive can save significant energy compared to running small fans continuously. 4

Variable Speed Fans Chore-Time 54-, 52- and 48-Inch Fans* with HYFLO Shutters *Variable speed option available for certain galvanized and fiberglass fan models. The Energy-Efficient Way to Smooth House Temperature and Airflow Changes Have you ever noticed excessive fan cycling? Have your young birds experienced chilling or increased mortality from excess airflow? Are you concerned about energy efficiency on your small minimum ventilation fans? Chore-Time s variable speed fan option offers a solution to these problems and an improved environment for your birds. Features and Benefits Improve the environment for your birds by using Chore-Time s Variable Speed Fan to smooth the house s airflow and temperature curves. Gain efficiency with impressive CFM/watt during ramp up and ramp down periods. Reduce framing costs for new construction or retrofitting by adding a Variable Speed Kit to a tunnel fan instead of installing a small fan. Inexpensively add variable speed capability to existing houses by converting existing tunnel fans to variable speed. Get Better Temperature Control and Energy Savings with Chore-Time s Variable Speed Fans Control Setting Fan Performance at.05 Static Pressure 58% (35 Hz) 10,400 CFM 30.1 CFM/Watt 67% (40 Hz) 14,100 CFM 29.1 CFM/Watt Airflow CFM with & without Variable Speed Fan Airflow (CFM) House without variable speed fan House Temperature ( F) House with variable speed fan Using Chore-Time's Variable Speed Fans smooths airflow and temperature efficiently and creates a better bird environment. Chore-Time s Variable Speed Fans Smooth the Airflow and Temperature in the House 1. Using your CHORE-TRONICS 2 Control and a Variable Frequency Drive, the fan equipped with variable speed capability comes on briefly at 100% to open the shutter, then drops back to the minimum speed setting. 2. The fan gradually accelerates to 100% (based on house temperature) until the first tunnel fan comes on. It then drops back to the minimum speed setting again and begins ramping up as the house temperature increases. This process can be repeated until all tunnel fans are on. 3. By increasing (and decreasing) its airflow gradually, Chore-Time s Variable Speed Fan helps smooth out both airflow and temperature during the period before and after full tunnel operation. Chore-Tronics 2 Control Chore-Time Variable Frequency Drive 83% (50 Hz) 21,400 CFM 27.6 CFM/Watt 100% (60 Hz) 26,100 CFM 21.9 CFM/Watt Example features Chore-Time's 52-Inch Galvanized Fan with HYFLO Shutter, Part No. 49519-42. Contact Chore-Time for performance data for additional fan models. Bess Labs Test No. 08283 5

Air Circulating Fans, s and Fan Accessories Air Circulating Basket Fan Mixes air for more even house temperatures. 1/10-horsepower direct drive motor. Sealed ball bearings. Automatic thermal overload protection. Polyvinyl-coated heavy-duty guard for superior corrosion resistance. L -shaped ceiling mount bracket provided with fan. 20-Inch (508-mm) Diameter Basket Fan with Ceiling Mount Bracket Basket Fan Specifications Chart Part No. Diameter Motor Electricity 51702 20 inches (508 mm) 1/10 HP 1725 RPM 115/230V 1 Phase Box and Panel Fans Box fans are available in 24-, 36- and 48-inch diameters with metal framing in direct-drive. Wood framing is available for the 24- and 36- inch fans. Belt-drive is available for the 36- and 48-inch fans. Shutters Cone Covers HELP SEAL OUT DRAFTS during cold weather with optional cone covers made of vinyl-coated, ultravioletresistant fabric. Available in 53- or 64-inch (134 or 162 cm) outside diameters. Chore-Time s Shutters come in an aerodynamic belled style frame for greater efficiency as well as in a flat frame model for flush mounting. Available in white or gray. s flexible edge helps seal the fan s opening when fan is at rest. Corrosion-proof vinyl construction with a rigid vinyl frame and fiberglass rod hinges for the louvers. s are easy to replace and have a smooth, easy-care finish for low maintenance. Panel fans are available without framing in 36- and 48-inch diameters in belt- or direct-drive. Chore-Time s 36-inch Direct-Drive Box Fans deliver 10,980 CFM and 16.4 CFM/Watt at 0.00 static pressure. Flexible louver edge helps seal the fan s opening. Belled shutter has a curved, aerodynamic frame. 6

Fan Selection and Maintenance Recommendations The materials from which today s poultry house equipment is made have not changed, but the poultry house environment has. Proper equipment selection and maintenance has never been more important. Poultry houses tend to have more moisture, ammonia and chemicals than in years past. Houses are more air tight. Rising fuel costs lead to underventilation. Advanced litter treatments permit more dampness and ammonia on floors. Without curtains, all moisture must be removed by power ventilation. Using tunnel fans to exhaust air from the brood chamber introduces hot humid air in the grow-out area. Increased amounts of ammonia exhausted through fans can cause extensive damage. During cool weather, the combination of hot humid air and cold surfaces can lead to condensation. Condensation on galvanized metal can result in corrosion and serious damage. The problem of corrosive chemicals in the house is compounded if chemicals are allowed to come into contact with wet equipment. Best Practices for Bird Health and Equipment Life Reduce Moisture in the House Follow minimum ventilation standards based on birds age. Maintain relative humidity in the house below 70%. Limit the Effects of Corrosive Elements Maintain fans properly. Remove surface dust and dirt from fans between flocks. When cleaning fans, don t leave standing water on metal surfaces. Avoid direct contact of chemicals with equipment. Choose Fans Wisely Consider whether the fan is made of heavyduty, corrosion-resistant materials. Evaluate the warranty and the company behind it. Contrast the fan s performance and energy usage with its cost and life expectancy. Fan Selection Comparison Chore-Time Fans 52-Inch Fiberglass 52-Inch Galvanized 54-Inch Galvanized CFM Better Good Best CFM/Watt Better Good Best Life Expectancy Best Good Good Warranty Best Good Good Price Higher Lowest Lower 7

Tunnel Fan Specifications (60 Hz 1 Phase) Fans are arranged in descending order by fan capacity at 0.10 static pressure. Chore-Time recommends considering both capacity (CFM) and performance (CFM/Watt) when selecting a fan..05 Static Pressure.10 Static Pressure Air Flow Bess Labs Size Mat. Style Shutter Drive Type Fan P/N CFM CFM/Watt CFM CFM/Watt Ratio Test No. 54 inch 137.2 cm G C HYFLO BD High-Cap. 52157-21 30,800 22.0 28,900 19.4 0.80 09080 132.1 cm F C HYFLO BD High-Cap. 49740-21 29,700 20.5 27,700 18.3 0.79 04312 132.1 cm G C HYFLO BD High-Cap. 49519-21 29,100 20.0 27,300 18.0 0.78 05188 132.1 cm G SW-C Bell BD High-Cap. 48319-215 27,800 18.7 26,300 17.1 0.80 05197 54 inch 137.2 cm G C HYFLO BD Energy-Eff. 52157-22 27,700 25.3 25,800 22.0 0.78 09081 121.9 cm F C Bell BD High-Cap. 47898-4825 26,400 18.0 25,000 16.3 0.83 02473 132.1 cm F C HYFLO BD Energy-Eff. 49740-22 27,000 23.5 24,900 20.8 0.73 04334 132.1 cm G C HYFLO BD Energy-Eff. 49519-22 26,400 23.6 24,500 20.8 0.76 05186 132.1 cm G SW-C Bell BD Energy-Eff. 48319-225 24,900 21.6 23,300 19.4 0.78 05198 121.9 cm G SW-C Bell BD High-Cap. 48318-215 24,400 20.3 22,900 18.0 0.77 04323 121.9 cm G C HYFLO BD High-Cap. 49515-21 24,600 20.8 22,700 18.0 0.76 04327 121.9 cm F C Bell BD Energy-Eff. 38264-4825 23,600 21.2 22,100 19.0 0.74 04332 121.9 cm G C HYFLO BD Energy-Eff. 49515-22 21,100 24.4 19,600 21.3 0.77 04326 121.9 cm G SWC Bell BD Energy-Eff. 48318-225 20,700 23.2 19,200 20.2 0.75 04321 Other Exhaust Fan Specifications (60 Hz 1 Phase) Fans are arranged in descending order by fan capacity at 0.10 static pressure. Chore-Time recommends considering both capacity (CFM) and performance (CFM/Watt) when selecting a fan..05 Static Pressure.10 Static Pressure Air Flow Bess Labs Size Mat. Style Shutter Drive Fan P/N CFM CFM/Watt CFM CFM/Watt Ratio Test No. 36 in / 91.4 cm F C Flat BD 38589-3622 11,960 19.0 11,190 17.0 0.79 96199 36 in / 91.4 cm G SW-C Flat BD 46130-3622 11,030 17.8 10,200 15.5 0.75 00174 36 in / 91.4 cm F C Flat DD 38265-3622 10,970 18.6 10,200 16.8 0.73 96159 36 in / 91.4 cm G SW-C Flat DD 44860-3622 10,210 17.9 9,460 15.9 0.75 99217 36 in / 91.4 cm G C HYFLO DD 50372-22 9,880 21.5 9,160 18.9 0.76 06241 24 in / 61.0 cm F C Flat DD 40452-2422 5,990 16.2 5,550 15.0 0.73 98012 KEY: Mat.=Material; G=Galvanized; F=Fiberglass; C=Cone; SW-C=Slantwall Cone; BD=Belt-Drive; DD=Direct-Drive A variable frequency drive option is available for the following 3-phase fan models: 52-inch fiberglass energyefficient and high-capacity fans; 48-inch fiberglass energy-efficient fan with special motor; and 54-inch and 52-inch galvanized energy-efficient fans. This is a sampling of the many fan sizes, models and configurations that Chore-Time offers. Additional electrical specifications also available. Contact your certified TRUE RED distributor for details on any fans not shown here. Feeding Drinking Controls Ventilation Heating Nests Feed Storage Find your certified TRUE RED distributor in our on-line distributor finder. www.choretimepoultry.com Chore-Time Poultry Production Systems Chore-Time Brock International Divisions of CTB, Inc. Phone: 574.658.4101 or +1.574.658.9323 (International) E-mail: poultry@choretime.com or world@ctbworld.com CT-2298/0911