Certain Uncertainty - Demonstrating safety in fire engineering design and the need for safety targets.

Similar documents
IAEA SAFETY STANDARDS

Fire Safety Design when Normal Limits Don t Apply

Are we using the wrong design fires for tall building fire strategies, in light of recent full height fires?

COMPARISON OF NFPA AND ISO APPROACHES FOR EVALUATING SEPARATION DISTANCES

Fire protection of emergency electrical devices: effect on the level of risk a case study of a rail tunnel

PRELIMINARY ANALYSIS OF THE NUMBER OF OCCUPANTS, FIRE GROWTH, DETECTION TIMES AND PRE-MOVEMENT TIMES FOR PROBABILISTIC RISK ASSESSMENT

RISK-ORIENTED FIRE ENGINEERING APPROACH IN HONG KONG FOR THE NEXT GENERATION

How design fires can be used in fire hazard analysis

PRIMATECH WHITE PAPER CHANGES IN THE SECOND EDITION OF IEC 61511: A PROCESS SAFETY PERSPECTIVE

ISO INTERNATIONAL STANDARD. Fire safety engineering General principles. Ingénierie de la sécurité incendie Principes généraux

Functional Safety: the Next Edition of IEC 61511

Effectiveness of sprinklers in residential premises:

Fire Severity for Structural Design

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

SIL DETERMINATION AND PROBLEMS WITH THE APPLICATION OF LOPA

Fire Resistance - Implications for regulations and standards of the September 11th terrorist attacks on the world trade centre Tom Lennon, FRS, BRE

Fire Engineering in High Rise 15 November 2013

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

Y. ORMIERES. Fire risk analysis method for nuclear installations

and SUMMARY current building code provisions, and alternative

Comparative Evaluation Method for Fire Safety Design of Large Storage Spaces

26 June 2001 GUIDELINES ON ALTERNATIVE DESIGN AND ARRANGEMENTS FOR FIRE SAFETY

The Role of Engineering Judgement in Fire and Gas (F&G) Mapping

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE

This document is a preview generated by EVS

Assessment of the Probabilities that Staff and/or Patients Will Detect Fires in Hospitals

National Fire Protection Association 1 Batterymarch Park Quincy, MA USA

2015 Functional Safety Training & Workshops

Establishing the Risk Basis of Building Size Limits

Prescription of qualifications. ARB Criteria at Part 2

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

USER APPROVAL OF SAFETY INSTRUMENTED SYSTEM DEVICES

The SIL Concept in the process industry International standards IEC 61508/ 61511

FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY ABSTRACT

a high level of operational reliability), and the designer (in performing probabilistic-based

New developments in Nordic countries in fire safety engineering guidance

The Macro Quallty Assurance System for Fire Safety Engineering

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ROLE OF THE FIRE PROTECTION ENGINEER IN THE CONSTRUCTION DESIGN PROCESS

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ENGINEER AND THE TECHNICIAN DESIGNING FIRE PROTECTION SYSTEMS.

Wayside horn noise investigation

New requirements for IEC best practice compliance

Advantages and Disadvantages of Fire Modelling

Assessment of the Safety Integrity of Electrical Protection Systems in the Petrochemical Industry

Experiments to Validate the NRCC Smoke Movement Model for Fire Risk-Cost Assessment

The Current (2017) State of the Art for Air Leakage in Ductwork

ANALYSIS OF HUMAN FACTORS FOR PROCESS SAFETY: APPLICATION OF LOPA-HF TO A FIRED FURNACE. Paul Baybutt Primatech Inc. and

Official Plan Review: Draft Built Form Policies

Writtle University College Policy & Principles for Sustainable Development

CDOIF. Chemical and Downstream Oil Industries Forum. Guideline Leak Detection. Guideline Leak Detection v0.6 Page 1 of 25

Design Occupant Groups Concept Applied to Fire Safety Engineering Human Behaviour Studies

SELF PRESERVATION SOCIETY By Jim Creak

Transitioning to ISO 9001:2008. Profession Development for ASQ Chapter 309 Tanzco Management Consulting, LLC

IEC an aid to COMAH and Safety Case Regulations compliance

Fire Risks of Loviisa NPP During Shutdown States

A HOLISTIC APPROACH TO FIRE RISK MANAGEMENT FOR BUILDINGS IN THE UK

Risk-informed Airport Fire Engineering Solutions for Operational Continuity

EPSRC Research Project: Real Fires for the Safe Design of Tall Buildings

ECONOMIC JUSTIFICATION FOR SPRINKLER SYSTEMS

INTERNATIONAL STANDARD

A Priori Modelling of Fire Test One

INTERNATIONAL STANDARD

Impact of Supervisory Gas Pressure on Dry Pipe Sprinkler System Water Delivery Time. Steve Wolin Director, Development and Compliance

Fire Resistance Proficiency Testing of Gypsum/Steel-Stud Wall Assemblies. William L. Grosshandler 1

A DESCRIPTION OF THE PROBABILISTIC AND DETERMINISTIC MODELLING USED IN FIRECAM

Fire and Gas Detection and Mitigation Systems

Sustainable Urban Drainage Systems (SuDS): Design and Implementation

IEC61511 Standard Overview

Practicalities and Limitations of Coupling FDS with Evacuation Software

Advisory Brief to Prince George City Council On the Matter of Bylaw 8727, 2013, Fire Protection and Emergency Response Bylaw

Failure Modes, Effects and Diagnostic Analysis

Optimum Room Acoustic ComfortTM (RACTM) can be achieved by using a selection of appropriate acoustic descriptors

OFFICIAL. OFFICIAL Page 1 of 10. HALES Evaporator C. Reduction in MOP reservation held on Evaporator C & reallocation to Evaporator A & B

COST-EFFECTIVE FIRE-SAFETY RETROFITS FOR CANADIAN GOVERNMENT OFFICE BUILDINGS

(Non-legislative acts) REGULATIONS

Estimating the Level of Free Riders in the Refrigerator Buy-Back Program

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY

6 th Pipeline Technology Conference 2011

Fire Safety within the Kaipara District Plan Change 2 update and Summary of Proposed new Approach

Edinburgh Research Explorer

Saving resources by going evaporative: how evaporative cooling technologies and water cooled chillers can significantly reduce energy

Emerging Technology Program

GAS DETECTOR LOCATION. Ø.Strøm and J.R. Bakke, GexCon AS, Norway

ALTERNATIVE DESIGN AND ARRANGEMENTS FOR FIRE SAFETY

Accounting for Sprinkler Effectiveness in Performance Based Design of Steel Buildings for Fire

Beyond Compliance Auditing: Drill til you find the pain points and release the pressure!

Managing technical risks

The Singapore Fire safety Engineering Guidelines (SFEG)

Adam Monaghan BSc (Hons) CEng MIFireE

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

Modelling Concepts for the Risk-cost Assessment Model FIRECAMTM and its Application to a Canadian Government Office Building

To: All SAAS Accredited Certification Bodies Subject: Clarification to Emergency and Health & Safety Requirements in the SA8000 Standard

Franz Evegren. Robust brandriskbedömning ur ett IMO-perspektiv

FIRE PROBABILISTIC SAFETY ASSESSMENT FOR KUDANKULAM NPP IN INDIA. G.Tokmachev. Atomenergoproekt, Bakuninskaya 7, Moscow, Russia

Dangerous Assumptions

Interim Advice Note 76 / 06 ASSESSMENT PART 1 AIMS AND OBJECTIVES OF ENVIRONMENTAL ASSESSMENT. Contents

BUSINESS PLAN CEN/TC 58 SAFETY AND CONTROL DEVICES FOR BURNERS AND APPLIANCES BURNING GASEOUS OR LIQUID FUELS EXECUTIVE SUMMARY

Evolving Fire Safety towards holistic Safety A Proposal. Lance Rütimann Senior Manager Industry Affairs, Siemens Switzerland Ltd.

Practical problems of applying performance-based structural fire engineering in building design

Official Journal of the European Union. (Non-legislative acts) REGULATIONS

Transcription:

Certain Uncertainty - Demonstrating safety in fire engineering design and the need for safety targets. Danny Hopkin 1, Ruben Van Coile 2 & David Lange 3 Introduction In his 2008 IAFSS plenary, Andy Buchannan 1 provided a timely reminder that fire safety designs are ultimately limited by the crudest idealisation made in the process of arriving at solutions. The suggestion was made in reference to structural design for fire safety, where often highly sophisticated tools and methods were deployed to investigate structural response when subject to comparably primitive idealisations of fire conditions. However, the need for a consistency of crudeness isn t limited to the interface between the structural & fire engineering disciplines. In developing fire safety designs, engineers endeavour to propose solutions that are cognisant of project goals and are delivered within often competing constraints 2. The most fundamental of these goals is ensuring that an adequate level of safety is achieved. Defining what is adequate under differing circumstances is not straightforward. The ability to articulate and quantify this most fundamental goal is often the crudest facet of the fire safety design process 3. Convention in performance-based fire safety design By tradition, performance based fire safety design is deterministic. The adequacy of a proposed design is demonstrated via an evaluation of performance under one or more assumed scenarios and through benchmarking against pre-determined safety objectives. The likelihood of the scenarios is not explicitly considered. Where uncertainty exists about the development of a scenario, assumptions are made (e.g. where the fire is, its severity, its evolution with time, the rates at which species are produced, etc.). When the design passes all performance criteria for a given objective, the achievement of adequate safety is assumed and the design is accepted. This assumption is often valid and is premised on fundamental safety foundations. Safety Foundations The safety foundations are the justifications upon which the safety of the design relies. For traditional deterministic fire safety design, the following two safety foundations are identified by the authors: 1. Collective experience of the profession Common and longstanding application in designs, where there are no observations of unacceptable performance in multiple fire events, is indicative of meeting the fire safety goals. 2. Large level of conservativeness The assumptions assoicated with the investigated scenarios are conservative, demonstrating acceptable performance with respect to these scenarios is sufficient to demonstrate the overall adequate performance. The first safety foundation recognizes that continued trial and error, combined with public outcry at unacceptable failures, has resulted in the adequacy of design assumptions being accepted by precedent 4. The second safety foundation requires that the large level of conservativeness is obvious and thus requires that the physics of the fire and the basis of the performance criteria are well 1 Olsson Fire & Risk Danny.Hopkin@OlssonFire.com 2 University of Edinburgh - Ruben.VanCoile@ed.ac.uk 3 Research Institutes of Sweden - David.Lange@ri.se

understood. In the end, the second safety foundation is thus again based on the common experience of the profession. The above is conceptually visualized in the left-hand side of Figure 1 below, introducing the safe-design triangle in analogy to the well-known fire triangle. Only when the safedesign triangle is founded on a solid safety foundation of collective experience of the profession, can safe design be assumed. Reliance on the collective experience of the profession can, however, only hold when there are ample example cases to learn from (i.e. a sufficient number of fire events), which guide the profession towards adequate safety levels. Consequently, the justification of adequate safety through experience by definition does not hold for exceptional structures, for (very) low probability events, or for innovative building designs and/or materials 5. This implies that the safety foundation of the safedesign triangle is weak, or missing entirely, and thus adequate safety cannot be assumed. In order to provide a basis for the safe design triangle, an alternative safety foundation must be found. This is an explicit evaluation of the safety level, resulting in the right-hand side of Figure 1, indicating a necessity to explicitly demonstrate adequate safety. Figure 1 (left) assumed basis of safe design, (right) demonstrated basis of safe design where experience is not an adequate basis Explicitly demonstrating safety Demonstrating safety requires taking into account the uncertainties associated with the design problem. For example, if a sprinkler system is installed then the reliability of the sprinkler system must be taken into account to correctly identify the range of possible consequences (see the probability tree in Figure 2). Evaluating the safety level and demonstrating safety necessitates that the designer take into account the probabilities of different scenarios and the uncertainty associated with input variables. Consequently, the safety verification should then necessarily be based on a Probabilistic Risk Analysis (PRA) a departure from the currently widely adopted deterministic approach to performance based design. This makes PRA not a methodology for future fire safety engineering 6, but rather the methodology that the fire safety community has neglected for too long as it is a necessary methodology to provide a safety foundation for uncommon fire safety designs.

Figure 2 Concept probability tree The consequence of fire occurrence are dependent on sprinkler operation. Assuming operation / no operation misses important aspects of the range of consequences. In the UK, guidance on the application of PRA is given in PD7974-7:2003 7, which is currently under revision. In its most standard form, PRA considers the entire range of possible consequences C and the associated probabilities P. This combination defines the risk of the design. Acceptability of the design is then determined through absolute or comparative acceptance criteria, or by application of the As Low As Reasonably Practicable (ALARP) principle (Figure 3). Figure 3 Illustrative fn curve Societal acceptance criterion for a disaster: Relationship between consequence severity (event severity) and the frequency of event (event likelihood)

Most designs will need to demonstrate that they meet the ALARP criterion. Defining ALARP is, however, difficult as it requires a balancing of whole-life investments with uncertain safety benefits. This balancing of costs and benefits can be done explicitly by applying cost-benefit analysis (CBA, or Lifetime Cost Optimisation), but the valuation of uncertain future costs and benefits quickly becomes particularly challenging. In structural engineering this challenge is regularly avoided by directly introducing safety targets 8. These safety targets specify the maximum probability of failure considered acceptable for a structural element and have been calibrated through CBA based on generalized cost assumptions (and on the premise of meeting the tolerability threshold). Thus, the target safety levels applied in structural engineering (i.e. those found in the Joint Council on Structural Safety (JCSS) probabilistic model code 9 ) ensure that an adequate safety level is obtained, while implicitly taking into account the costs and benefits of safety investments. The lack of clearly defined & accepted safety targets in fire safety engineering means that currently a full CBA is required to demonstrate that a design meets ALARP. This, however, can be seen as onerous by fire safety engineers, particularly given that the PRA process is not convention, and perpetuates the sometimes unjustified reliance on traditional experience based safety foundations. Conclusion and call to action At a minimum, the role of the engineer is to achieve a design which delivers adequate safety levels. The regulatory environment in which many fire engineers work perpetuates the reliance on either the collective experience of the profession, or a large level of conservatism, to be able to conclude that a design is safe. However, without sufficient probing of the safety level there is a risk of failing to meet safety obligations, particularly when extrapolating a precedent premised safety foundation to include exceptional structures. Fire engineers have the tools, and frequently exercise them; to conduct analyses of solutions based on various design values and an almost endless variety of scenarios. The capability exists to determine additional performance criteria bespoke to any project through dialogue with all involved stakeholders: developers, regulators and end-users. However, to date as a community there has been little explicit consideration of the safety level as required to demonstrate a safe design. This means that the foundation of the safe design remains assumed as opposed to evaluated. The fire safety profession has often relied in the past on so-called magic numbers and golden rules 10 entrenched in standards and against which the adequacy of alternative solutions are often gauged. The field has progressed now to the point that the tools and techniques available can be applied to explicitly determine the safety levels achieved. The next step is to address the foundation of safe design and to explicitly probe the safety level which is appropriate for a given case. A concerted effort by the fire safety community to address uncertainties and to determine target safety levels as is done in, for example, structural engineering, therefore, has the potential to significantly improve the process of demonstrating adequate safety for exceptional designs and new applications. In the absence of this, the foundation on which a performance based solution is accepted is just another crude golden rule, based on precedent.

References 1 Buchanan, A. (2008). The Challenges of Predicting Structural Performance in Fires. Fire Safety Science 9: 79-90. doi:10.3801/iafss.fss.9-79. 2 A. Law, J. Stern-Gottfried, N. Butterworth. (2015). A risk based framework for time equivalence and fire resistance. Fire Technol, 51 (4), pp. 771-784, 10.1007/s10694-014-0410-9 3 Hopkin, D., Ballantyne, A., O Loughlin, E., McColl, B., 2016. Design goals fire resistance demands for tall residential buildings. Proceedings of Interflam 2016. 4 Spinardi, G., Bisby, L., Torero, J. (2017). A Review of Sociological Issues in Fire Safety Regulation. Fire Technology, 53, 1011-1037 5 Croce, P.A., Grosshandler, W.L., Bukowski, R.W., Gritzo, L.A. (2008). The International FORUM of Fire Research Directors. A position paper on performance-based design for fire code applications. Fire Safety Journal, 43, 234-236. 6 Hadjisophocleous, G.V., Benichou, N. (1999). Performance criteria used in fire safety design. Automation in Construction, 8, 489-501. 7 BSI. (2003). PD 7974-7:2003, Application of fire safety engineering principles to the design of buildings Part 7: Probabilistic risk assessment. British Standard 8 ISO 2394:2015, General principles on reliability of structures. International Standard. 9 JCSS. (2001). Probabilistic Model Code, Joint Committee of Structural Safety, JCSS-OSTL/DIA/VROU -10-11- 2000. 10 Law, M., Beever, P. (1994). Magic Numbers and Golden Rules. International Association for Fire Safety Science - Proceedings Of The Fourth International Symposium, pp. 79-84.